Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

NLC Tamil Nadu Power Limited

Tamil Nadu

  • Opening Date

    03 Sep 2019

  • Closing Date

    18 Sep 2019

  • Tender Amount

    Refer document

  • EMD

    -

Reminder

Follow

Download
Are you Looking for Joint Venture Partners, Contractor Consortium, Back-to-Back Contractor, Project Financier?
We will help you to find the right match for FREE.
Summary

Purchase Of 1100v Grade, 3c X 35 Sqmm Aluminium, Xlpe Cable

Documents
Don't have sufficient eligibility, BG funds or resources?
We will help you to find the right match for FREE.
BOQ Items

No BOQs Available

Due Date of Cover-I Opening : 18/09/2019 15:00:00 hrs. IST (Check NTPL eproc website for any change in due date of opening.) Note : Quotation should be valid for 60 days from the date of opening. Gentlemen, We shall be glad to receive your lowest online offer submitted through http://eproc.ntplpower.com for the material mentioned below, subject to our terms and conditions. Any other mode of offer will be rejected. Please indicate the enquiry number in all future correspondence. Offer details of the participating bidders will be available online after the tender is opened. Sl No. Details UOM Quantity 1 Specification 92 061 0008 : 1100V grade, 3C x 35 Sqmm Aluminium, XLPE insulated, FRLS inner and outer sheathed Armoured Power Cable. Sl No. Technical Factor(s) 1 XLPE Power cable Stranded Aluminium Conductor ,XLPE insulated ,inner sheath of Extruded FRLS Type PVC (TYPE ST2),Single layer of Round Galvanised Steel wire Armoured and FRLS Type PVC(Type ST2)SHEATHED Overall,1100 Volts grade, conforming to IS :7098/Part.1 2 1100 V grade, power cable conforming to following requirement and in line with IS 7098 Part I, IS5831, IS-8130 IS-3975, ISI Marked. . 3 Cable identification will be provided by embossing the following on the outer sheath: a) Manufacturer's name or trade mark b) Voltage grade c) Year of manufacture d) Type of insulation e) Type of inner and outer sheath e.g.FRLS etc. f) ISI marks g) Nominal cross sectional area of the conductor & no of cores h) Sequential marking. i) Owner identification mark i.e. NTPL 5 Insulation - Extruded Cross Linked Polyethylene conforming to 7098 Part I. Inner sheath - Extruded FRLS PVC compound conforming to type ST2 of IS: 5831 for multicore cable. 6 Armour - Galvanised single round/ strip steel wire armour for twin and multicore cables. Non-magnetic hard drawn aluminium single round wire conforming to H4 grade for single core cables 7 Overall Sheath - Extruded FRLS PVC compound conforming to type ST2 of IS: 5831. FRLS :- Conforming to IS 10810 or relevant ASTMD/IEC/other international standards Metres 1200.0000 NLC TAMILNADU POWER LIMITED [A JV between NLC India Ltd(formerly Neyveli Lignite Corporation Ltd) &TANGEDCO and subsidiary of NLC India Ltd] Contracts & Purchase Division Office of Chief Executive Officer 2x500 MW Thermal Power Plant, Harbour Estate,Tuticorin-628004. Tamilnadu, India. Phone: 0461-2352844, 2352840 Fax: 0461-2352480 Email:ceo.ntpl@nlcindia.in, candp.ntpl@nlcindia.in /TENDER ENQUIRY NO :ENQ/NTPL/19-20/000262/C&P01(01) /DATE :03/09/2019 /Page - 1 YOUR OFFER SHOULD BE ON DOOR DELIVERY BASIS AT NTPL STORES TUTICORIN /Inspection Clause : Inspection at Tuticorin /Guarantee Requirement : General Guarantee for Warranty as per NTPL format Warranty Period: 12 months from the date of commissioning or 18 months from the date of receipt of material, whichever is earlier. Basis of Evaluation : Item-wise. Attachments : Terms and Conditions of Enquiry Registered Office: First Floor, No.08, Mayor Sathyamurthy Road, FSD,Egmore Complex of Food Corporation of India,Chetpet, Chennai-600 031. This Document has been digitally signed.Page 1 of 3 Sl No. Details UOM Quantity 8 Oxygen Index Part 58 of IS 10810/ASTMD 2863 77. FlameRetardance Test Part 61 for single cable and Part 62 for bunched cables. (AS per IEC 332 Part 3 CAT B and IEEE 383) Swedish Chimney SS 424 1475 F3. Smoke Density Test Part 63 of IS 10810/ASTMD 2843. Temperature Index Test Part 64 of IS 10810/ ASTMD2863. Test for rodent and termite repulsion property. 9 Halogen Acid Gas Evolution Part 59 of IS 10810/IEC 754 I 10 FlameRetardance Test Part 61 for single cable and Part 62 for bunched cables. (AS per IEC 332 Part 3 CAT B and IEEE 383) Swedish Chimney SS 424 1475 F3. 11 The cable shall be supplied in length of 600 metres with +/ -2.5% overall tolerance without any joint and sealed at the ends. The Payment will be restricted to the ordered quantity or the quantity supplied whichever is less. 12 Drum shall be Steel. D

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.