Indian Institute Of Technology Tender

... More
The IIT has issued a formal invitation for competitive bids for the Indian Institute Of Technology project, for Provision Of Ac Facility To Gf And Ff Of Campus Cafe In Iit Madras in Chennai, Tamil Nadu, with an estimated contract value of Rs. 64,03,000. The bid opening date for this tender is 15-10-2022 and the last date for bid submission is 27-10-2022. Interested bidders for Indian Institute Of Technology tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Indian Institute Of Technology - IIT Tender

Works
Electrical and Electronics
Eprocure
Opening Date15 Oct 2022
Closing Date27 Oct 2022
Tender Amount₹ 64,03,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation, testing and balancing of weather proof louvers with bird screen for fresh air / exhaust air as per specifications and approved drawings.

-

-

-

... More
Supply, installation, testing and commissioning of COOLING THERMOSTAT with Power / Control Cabling for various air handling units and fan coil units as described in specifications. The thermostat shall be proportionately type for modulating control valve with digital temperature indicator. Receiving at site the imported equipment, unloading, storing, handling hoisting, installing in position, effecting connections, anchoring, grouting testing and commissioning the equipment including supplying & installing all necessary indigenous accessories as required to complete the installation.

-

-

-

... More
Inlet and outlet connection of chilled water shall be on same side.

-

-

-

... More
COOLING THERMOSTAT :

-

-

-

... More
Supply and laying of 6 sq.mm single core copper FRLS unarmoured cables for equipments earthing including termination with copper lugs in both ends

270

-

-

... More
Supply and fixing of Acoustic lining of wall and ceiling of AHU rooms with 50mm thick density 32Kg/Cu.m resin bonded glass fibber insulation friction fixed in 610mm X 610mm frame work made of 25X50mm made out of 0.6mm thick G.I Sheet U shaped channel and covered with reinforced fibre glass tissue and finished with .80mm perforated aluminium sheet etc. Complete as per Specifications.

625

-

-

... More
BMS compatible Actuators with Control Panel & Wiring

4

-

-

... More
VOLUME CONTROL DAMPER :

-

-

-

... More
PIPES AND VALVES

-

-

-

1

-

-

... More
1.0mm thick GSS ducting (20G) – factory fabricated

90

-

-

... More
Proportional cooling thermostat at AHU.

2

-

-

... More
Thermal break profile at corners and at joints for double skin air handling units along with internal covings.

-

-

-

... More
All AHU's will be supplied with two sets of filters. One set will be for Pre commissioning & one original set of post commissioning Filters shall be EU-4

-

-

-

... More
10 mm thick

90

-

-

... More
Variable vertical inline Pump with Head of 15m and flow rate of 100 Cu. Per hour.

1

-

-

1

-

-

... More
100 NB

1

-

-

... More
Supply, Installation, Testing & commissioning of Single stage centrifugal coupled type pump set with axial suction port and radial discharge port, bronze impeller, mechanical seal, three phase TEFC squirrel cage motor with IP 55 protection, Class F insulation having a speed of 1450 rpm for chilled water circulation having the following duty conditions as per specifications along with vibration Isolators/rubber bellows /MS supports arrangements. Motor shall be suitable for VFD operation. (Vertical Inline pump with suction guide and other accessories). The pump shall be supplied with VFD drive with control panel as required. The accepted make shall be Amstrong/Xylem/Grunfos.

-

-

-

... More
Chilled water cooling coil shall be of copper tubes with aluminum fins and 6 rows deep suitable for chilled water operation.

-

-

-

... More
Capacity: 50.0 TR, Dehumidified Air: 20000 CFM, AHU with 65mm Static Pressure (Valve Sizes 65 MM)

1

-

-

... More
150 mm x 50mm Perforated type cable tray along with top cover

30

-

-

... More
285(W) x 285(H) x 1525(L) with effective air throw upto 2.5 mts.

2

-

-

... More
HVAC - ELECTRICAL WORKS

-

-

-

... More
Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, 4 way TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of TP/4P 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars as required . (Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
The air distribution system comprises with all supports like anchor fasteners and tie-rods, cradles, angle iron supports, bolts and nuts, 4mm thick self-adhesive neoprene rubber gasket, stiffeners, zinc chromate painted angle iron flanges, chipping and plastering of openings made for duct supports etc., filling the gap with fibre glass wool and with fire sealant complete as per specification. The rates quoted shall include turning vanes, straightening vanes, splitters, inspection doors probe, provisions for BAS sensors, inlets with test openings enclosures complete with locking caps, chain, gaskets, insulating plugs, and extension for insulated ductwork etc.

-

-

-

... More
Supply and installation of following sizes/ratings of industrial range air curtains of high velocity with low noise aluminium impeller of forward curved SS blades,pre lubricated sealed ball bearing type,easily mountable, vibration free complete set to operate 230V,50 Hz power supply. The accepted make will be ALMONARD/AIRCON.

-

-

-

... More
Fire retardant flexible canvas connection and cushy foot mounting for fan

-

-

-

... More
80 NB pipe with 30mm thick PUF insulation

12

-

-

... More
65 NB

1

-

-

... More
Capacity: 44.0 TR, Dehumidified Air: 17600 CFM, AHU with 65mm Static Pressure (Valve Sizes 50 MM)

1

-

-

... More
Supply and erection of SS Glycerine filled Thermometers with copper separable well complete with guard mounted on water lines, etc.

2

-

-

... More
LOUVERS :

-

-

-

... More
Outgoings: 32 amps, 10 kA TP MCB, C Curve-3 Nos. & 6- 10 amps SP MCB- 3 Nos.

2

-

-

... More
0.8mm thick GSS ducting (22G) – factory fabricated

150

-

-

... More
Supply and erection of the following UPVC pipe with all joints, reducer, necessary elbows and tees, supporting arrangements, etc. Rate shall be inclusive of 19mm thick FM approved closed cell nitrile rubber insulation covering with fire resistant fibre cloth fabric as a resistant to Scratch & Mechanical Impact.

-

-

-

... More
3.5 core 35 sq.mm XLPE alu.conductor armoured cable

75

-

-

... More
65 NB pipe with 30mm thick PUF insulation

12

-

-

... More
Supply and installing of Thermal insulation, Material shall be processed FM approved Crosslinked polyolefin foam with factory applied reinforced aluminium foil. The material should be fibre free. The Thickness of the material shall be as follows.

-

-

-

... More
25 NB pipe with 30mm thick PUF insulation

3

-

-

... More
50mm Dia

20

-

-

... More
AHU frame shall be made of non corrosive extruded aluminum profile fitted together with polyamide corner pieces.

-

-

-

... More
80 NB

1

-

-

... More
Note: The colour shade for the air distribution equipments like ducts, diffusers, grilles, etc shall be approved by the Client / Architects before procurement and execution. The powder coating shall be 50 to 40 microns

-

-

-

... More
Supply, installation, testing and balancing of Air Distribution System consists of factory fabricated Rectangular duct Galvanized Iron sheet metal ducting (Zinc coating 120GSM) with TDF/TDC flanges

-

-

-

... More
0.8mm thick GSS ducting (22G) – factory fabricated

300

-

-

... More
Horizontal Floor Mounted AHU

-

-

-

... More
Return Air Grilles

-

-

-

... More
Design, Supply, installation, testing and commissioning of motorized Fire damper in supply air/return air/exhaust air streams. The damper shall be made out of 16G thick galvanized sheet steel frame and blades of 16G galvanized steel with air tight arrangement. The damper shall be provided with control panel, BMS compatible actuator of the motorized Damper shall have required torque to ON / OFF the actuator with 220 V / 24 V transformer duly encased and wired, combined smoke and heat sensor and transmitters, control / communication cables, etc. The control panel shall be suitable for receive/send signal from the Fire Alarm System and status shall be monitored thru BMS.

-

-

-

... More
Supply and Installation of the following Cable Trays / Accessories Prefabricated hot dip galvanized 1.6mm thick sheet perforated / Ladder type cable tray including all necessary curved bends-tees-reducers, coupler plates, fasteners etc.,for the following sizes. Inclusive necessary fixing arrangement etc.

-

-

-

... More
Incomer: 100 amps, 16 kA 4 pole MCCB- 1 No.

-

-

-

... More
100 NB

1

-

-

... More
AHU shall be with Wall mounted type VFD Starter Panels located in respective AHU Rooms. The panel enclosure shall be same as for MCCs. (The VFD Starter Panel shall consist of MCCB Auto Manual Switch, Luminous ON/OFF Push Buttons, Internal Wiring, Connectors for power & Control cables & Other panel accessories to make the panel complete.) Panel Should be compatible with BMS System. All internal wiring in the AHU should be as per Firenorms

-

-

-

... More
3 Core 10 Sq.mm XLPE Copper conductor armoured Cable

40

-

-

... More
Supply, erection, testing and commissioning of chilled water circulation pipes. Pipes will be of Mild Steel - Class C and insulation material shall be PUF. The insulation material shall be covered with 24G Aluminium cladding for outdoor application

-

-

-

... More
Supply and fixing of Acoustic insulation - Material shall be FM approved, open cell Nitrile Rubber foam. The density of the same shall be within 140-180 Kg/m3. The maximum surface temperature the material should withstand is 105º C and minimum temperature should be -20ºC. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7. The Thickness of the insulation material shall be as follows

-

-

-

... More
6 Core 1.5 Sq.mm PVC Copper conductor armoured Cable

40

-

-

... More
4 Core 10 Sq.mm PVC Copper conductor armoured Cable

40

-

-

... More
AIR DISTRIBUTION SYSTEM

-

-

-

... More
Supply, fabrication, erection, testing and commissioning of factory fabricated powder coated GI flat Oval ducts. The price shall include associated coupling, bends, transformation pieces, collars, turning vanes( if any), ' GRIPPLE' supports/hanging system. All the duct joints shall be sealed with silicon sealant. The joints shall be with least leak. No additional payment will be made for insulating couplings,joints etc., The quoted rate shall be inclusive of loading, transportation, unloding, shifting & conduciting the pressure test as per the techical spcification & drawing details.

-

-

-

... More
AHU shall be along with VFD & Electrical cable connection from panel consisting with stand alone controller to AHU shall be done by HVAC contractor.

-

-

-

1

-

-

... More
Supply and erection of ‘Y’ type strainer with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of matching flanges, additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
Flange type filters with extruded aluminum flanges along with quick filter fixing arrangement with SS 304 wing nuts.

-

-

-

... More
65 NB

1

-

-

... More
Supply and erection of Butterfly valves(PN 16) as per specification complete with end flanges / matching flanges, additional supports, fixing accessories, thermal insulation, etc. The valve shall be gear operated for 200NB and above.

-

-

-

... More
SUPPLY AIR GRILLES :

-

-

-

... More
Supply and erection of SS Glycerine filled Pressure gauges complete with ball valve, mounting well, fittings and copper tubing extension where required

4

-

-

... More
Vertical Inline pumps

-

-

-

... More
Unit shall be provided with flanges and low leakage extruded motorised aluminum volume control dampers with positive locking arrangement and percent opening gradations on supply side, return side, fresh air side and purge side in loose condition.

-

-

-

... More
Powder coated/Anodized extruded aluminium construction.

1

-

-

... More
Smoke & Fire Dampers.

8

-

-

... More
Supply and erection of 25 NB Automatic Air Vents along with ball valve

8

-

-

... More
AIR HANDLING UNITS

-

-

-

... More
Supply, Delivery, Installation, testing & commissioning of Floor mounted Air handling units in Re-circulatory configuration with 24G (0.64mm) pre-plasticised G.I. outer skin and 22G (0.8mm) plain G.I. inner skin with 40kg/m3 density Polyurethen Foam/PIR insulation having thickness 43±2mm in double skin construction as per air flow diagrams & specifications with following accessories. AHU cost will be inclusive of lifting & putting inplace.

-

-

-

... More
EARTHING

-

-

-

... More
360(W) x 365(H) x 2000(L) with effective air throw upto 3.5 mts.

6

-

-

... More
13mm thick

1200

-

-

... More
Supply, Installation, testing and commissioning of Flow Control Valve - Pressure independent type with Dynamic Balancing Cum 2 Way modulating valves (PN-20) for AHUs with actuator in a single Unit of Valve provided with spring return function. The valve shall be suitable for standalone operation. Valve shall be of PN16 Rating. The BMS compatible actuator shall be supplied by the valve manufacturer and capable of accepting 2-10VDC / 4- 20 mA electric signal and shall provide similar transduced feedback output signal to control system. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications. Rate shall be inclusive of stepdown transformer, digital thermostat (modulation type) suitable for the given actuator, required length of 2Cx1.5Sqmm shielded communication cable, end flanges/matching flanges, additional supports, fixing accessories, dismantling the existing valves, thermal insulation, etc

-

-

-

... More
AHU shall be with blower shall be DIDW Centrifugal fans low aerodynamic losses, silent operation & high efficiency with class IE3 suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply,

-

-

-

... More
AHU shall be supplied with Stand-alone operation controller with built in applications inclusive of sensors, sensor cables & DP transmitter complete with DDC controller, It Should be compatible with BMS System as per technical specification

-

-

-

... More
Drain pan in 16G SS 304 construction along with 25mm nitrile rubber insulation with smooth finish and slope should be provided to have zero retention of water in drain pan. The insulation shall be sandwiched between to sheets of SS 304.

-

-

-

... More
Supplying & fixing of opposed blade volume control dampers in supply air duct collars as per approved drawings and specifications. Damper shall be with 18G GSS body and blades shall be with aluminium airfoil construction.

12

-

-

... More
200 mm x 100mm Perforated type cable tray along with top cover

30

-

-

... More
AHU will be mounting on 25 mm neoprene rubber for anti vibration

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.