Chennai Metropolitan Water Supply And Sewerage Board Tender

... More
The CMWSSB has issued a formal invitation for competitive bids for the Chennai Metropolitan Water Supply And Sewerage Board project, for Replacement Of Damaged Hdpe Water Main Pipes With Di Pipes At Astalakshmi Nagar (phase-ii) In Depot 147, Area Xi. in Chennai, Tamil Nadu, with an estimated contract value of Rs. 1,17,100. The bid opening date for this tender is 15-05-2025 and the last date for bid submission is 03-06-2025. Interested bidders for Chennai Metropolitan Water Supply And Sewerage Board tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender

Works
Pipe Line Project
Eprocure
Opening Date15 May 2025
Closing Date3 Jun 2025
Tender Amount₹ 1,17,100 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
a) 100mm dia DI pipe at 1.50m depth

3750

-

-

... More
b) 250mm dia DI pipe at 1.50m depth

665

-

-

... More
Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner frame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding, fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality, writing "METRO WATER" & work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the sites

8830

-

-

... More
Cutting of Pipe

-

-

-

... More
a) 100mm dia DI pipe at 1.50m depth

125

-

-

... More
b) 250mm dia DI pipe at 1.50m depth

23

-

-

... More
Conveying and fixing of specials

-

-

-

... More
100mm dia Tee

20

-

-

... More
100mm dia MJ Collar

20

-

-

... More
100mm dia 90 Degree Bend

20

-

-

... More
100mm dia Sluice Valve

8

-

-

... More
250mm dia Tee

5

-

-

... More
250mm dia MJ Collar

5

-

-

... More
250mm dia 90 Degree Bend

1

-

-

... More
250mm dia Sluice Valve

1

-

-

... More
Making Rubber joint

-

-

-

... More
a) 100mm dia DI pipe

682

-

-

... More
c) 250mm dia DI pipe

127

-

-

... More
Testing of M.S./C.I./P.V.C./D.I pipes with hydraulic testing equipment by filling with water(including cost of water @ Rs.60/KL) and testing to recommended pressure in convenient stetches and attending the bursts if any occured during the test, excluding the cost of pipes, including other incidental and operational charges, etc., complete for the following diametres of pipes.

-

-

-

... More
a) 100mm dia DI pipe

3750

-

-

... More
c) 250mm dia DI pipe

665

-

-

... More
Hire charges for diesel pumpset for 5HP

712

-

-

... More
Disjointing and refixing valves with tail pieces, etc., excluding excavation

-

-

-

... More
a) 100mm dia DI pipe

8

-

-

... More
c) 250mm dia DI pipe

1

-

-

... More
Construction of chamber for 100mm to 250mm dia. sluice valve including providing and fixing L.S. cover and frame of size 60 x 60cm

13

-

-

... More
Additional work of strom water crossing of DI water main pipes with 200mm dia PVC covering pipe including breaking and packing SWD concrete walls.

-

-

-

... More
a) 100mm dia DI pipe

17

-

-

... More
c) 250mm dia DI pipe

1

-

-

... More
Rectification of damaged house service sewer connections

-

-

-

... More
110mm dia U-PVC pipe

250

-

-

... More
110mm dia PVC Coupler

500

-

-

... More
Fitter (pipe laying/Bar bending ) II Class

55

-

-

... More
Boring and Tapping mains or Re-boring and Tapping main and fixing brass screw plugs or ferrules of sizes.

-

-

-

... More
15mm to 25mm (1/2” to 1”)

235

-

-

... More
32mm to 50mm (1 ¼” to 2”)

15

-

-

... More
Providing suitable dia non corrosive engineering plasticmouldedClampSaddlewithSS304threaded metal insertedfor tapping outlet suiting for ½”,3/4”&1”clear bore and with wide plastic strap(EngineeringPlastic)withSS304suitablebolts &nuts.Saddle to have sealing of Thermoplastic elastomeric (TPE) material around.

-

-

-

... More
20mm (1/2”)

235

-

-

... More
25mm (3/4”)

10

-

-

... More
32mm (1”)

5

-

-

... More
MDPE PE80 PN16 Blue pipe as per standards ISO4427and Tested as per BS6920 in WRC-NSF LTD, UK

-

-

-

... More
20mm (1/2”)

470

-

-

... More
25mm (3/4”)

20

-

-

... More
32mm (1”)

10

-

-

... More
Returning of old HDPE pipes to Stores of various size

-

-

-

... More
50MM OD TO 110MM OD

4

-

-

... More
200MM OD TO 315MM OD

25.88

-

-

... More
Additional work of strom water crossing for House Service water connection with 50mm dia PVC covering pipe including breaking and packing SWD concrete walls.

100

-

-

... More
SCENARIO- 2: TBM Available

-

-

-

... More
The Contractor must obtain the existing Static GCP points from CMWSSB which should be considered as the control point with known coordinates X, Y and Z. Survey consultant to ensure the closing error is within permissible limits (SoI Standards) while transferring the levels from the existing Static GCP points and the same to be presented as a report. The same process shall be adopted for random verification of positional accuracy of points established using the PBMs as base. As built survey for every sewage and water pipeline and other assets must be done using DGPS based RTK method by transferring the coordinates from the nearest Static GCP of CMWSSB. Where there are signal interruptions for the RTK method, Total Station can be used. The coordinates from the static GCP shall be transferred to the Total Station by RTK method and the co- ordinates of the assets can then be captured by Total Station. All the features, attributes of all the assets, utilities captured shall be Geo referenced as per standard Coordinate reference system (WGS 84 UTM Zone 44N). The final base map with assets and utilities shall be furnished in (.shp) format. The geo referenced assets and utilities along with the attributes (as specified by the GIS Wing, CMWSSB) shall be converted into proper geo database (FGDB / PGDB) with the attributes. One set Hard and Soft Copy of all the CMWSSB assets and utility has to be prepared category wise network wise in A0 Print for verification in a print scale of 1:1000 in A0 plot, with standard legends in international and NUIS standards and should be legible and three sets of final Hard Copy in A0 print.

-

-

-

... More
For the Underground / Surface Assets along the roads for the distance ranging from: (2 Km to 5 Km)

4.42

-

-

... More
For the Point Underground / Surface Assets along the roads

60

-

-

... More
Total excluding GST

1

100

100

... More
GST @18%

1

100

100



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.