Chennai Metropolitan Water Supply And Sewerage Board Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender

Civil And Construction
Eprocure
Opening Date29 Apr 2023
Closing Date6 Jun 2023
Tender Amount₹ 80,00,00,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
For Third Year

1

-

-

... More
For Fourth Year

1

-

-

... More
For Fifth Year

1

-

-

... More
For Sixth Year

1

-

-

... More
For Seventh Year

1

-

-

... More
VARIABLE COST - Cost of chemical Consumption

-

-

-

... More
For First Year

40150000

-

-

... More
For Second Year

40150000

-

-

... More
For Third Year

40150000

-

-

... More
For Fourth Year

40150000

-

-

... More
For Fifth Year

40150000

-

-

... More
For Sixth Year

40150000

-

-

... More
For Seventh Year

40150000

-

-

... More
ASSET REPLACEMENT COST (For Seven Years) - Mechanical Major Spares

-

-

-

... More
Replacement of major spares such as rotor, stator, sealing plate, bearing plate for 5 Nos of Pressure exchanger

5

-

-

... More
Replacement of major spares of seawater intake vertical pumps & motors

2

-

-

... More
Replacement of major spares of Raw water vertical transfer pumps & motors

2

-

-

... More
Replacement of major spares of UF CEB water transfer pumps & motors

2

-

-

... More
Replacement of major spares High pressure pumps & motors

15

-

-

... More
Replacement of major spares of Booster pumps & motors

15

-

-

... More
Supply of 80TR water cooled scroll chiller , 20TR Compressor 4 Nos & Electrical panel & Shell & tube cooler 40 TR capacity 2 Nos, 20 TR condenser shell & tube water cooled 4 Nos with structural with powder coating. All safety device high and low pressure switch control freeze protection thermo static electrical safety device three phase over current relay, thermal relay compressor, motor and reverse phase protection relay complete with control panel with single phase prevention and interlocking with control wiring , electrical panel board with control panel

3

-

-

... More
Replacement of major spares of Cooling tower Fan

1

-

-

... More
Laser Alignment kit

1

-

-

... More
NaOCl Pipelines- CPVC (Chlorinated Poly Vinyl Chloride) Pipe (Higher pressure rating with higher pipe thickness)

1

-

-

... More
ASSET REPLACEMENT COST (For Seven Years) - Electrical Major Spares

-

-

-

... More
Reconditional Cost for Variable Frequency A.C Drive for 900 KW motors

15

-

-

... More
Heat Exchanager Tubes .

12

-

-

... More
Reconditional Cost for Variable Frequency A.C Drive for 55 KW motors

22

-

-

... More
Fencing for Switchyard & Co2 area - G I CHAIN LINK FENCING MESH: Zinc Coated Galvanised iron wire - 1 job (Approximately 600m)

1

-

-

... More
110V DC, 55 cells, 180 Ah(minimum) / 200 Ah Stationary plant type lead acid battery set with battery charger.

2

-

-

... More
Hitachi 8.5 tonne AC Package unit for VFD - Supply of Hitachi 8.5 tonne AC Package unit for VFD , condenser coil:950mmx1044mm No.of rows deep:3; Material of tube :3/8 OD Imported Inner Grooved copper pipe.; Material offins:36SWG Aluminum.

1

-

-

... More
Supply & Application of HVIC Silicon RTV High Voltage Insulation Coating work at 110KV Switchyard.

1

-

-

... More
Servo transformer for lighting - COOLED STABILIZER+SURGE PROTECTION DEVICE: With First Filling Of Oil. Rating:600KVA, 3PHASE,4wire Input Voltage:360-460VAC Output Voltage:400VAC+/-1% Cooling: OIL COOLED Wave Form distortion: NIL Effect of Load power: NIL Ambient:0-45 deg CMAX and 95%RH including installation and commissioning

1

-

-

... More
Replacement of all the CFL lights of the entire plant to LED

1

-

-

... More
110KV Switchyard Equipments 1)123 KV, 3 Phase, 1250A, 40 kA, SF 6 Circuit Breaker - 1Nos 2)96 kV (RMS), 10kA, Outdoor type Lightning arrester - 1Nos 3)123 kV, 1000/400/150/1-1-1-1A, outdoor structure mounted type Current Transformer- 1Nos 4)Single Phase 110/root 3/ 0.11/Ö3KV, 150VA, 275KV(RMS) / 650KVP, 2 secondary winding, Potential Transformer - 1Nos 5)Single Phase 110/root 3/ 0.11/Ö3KV, 150VA, 275KV(RMS) /650KVP, 3 secondary winding, Capacitive Voltage Transformer - 1Nos 6)123 KV, 3 Phase, 1250A, 40 kA, Double break Isolator with single & double earth switch – Each 1Nos 7)13.2kV, 1500 kVAR capacitor banks capacitors – 3Nos including freight charges

1

-

-

... More
Protection Relays 1)REL650 Line protection relay -1 No 2)RET650 Transformer protection relay – 1Nos 3)Synchronization Relay - 1Nos 4)REF615 Feeder protection relay - 1Nos

1

-

-

... More
Air circuit breakers (Chiller breaker- 1 No, MPDB breaker - 1 No, MLDB breaker - 1Nos) including freight charges

1

-

-

... More
L&T Protection Realy

1

-

-

... More
1 No : 55KW, 1440 RPM, ABB Make, 3 Phase AC Induction Motor Stator Rewinding charges

15

-

-

... More
Aluminium to Copper cable 3 core 50sqmm i) Supply of cable junction box of size 600(W)x600(H)x350(D) wall mounted ,made out of 1.6mm thick CR sheet, powder coated with RAL7032with 30x8mm copper busbars supported with insulators provided with top and bottom cable entries. ii) Supply of cable (2R*3.5C*50Sqmm Armoured copper cable) iii) RO Booster pump motor terminal block iv) Gland for motor power cable termination for 50sqmm v) 50 Sqmm Copper lugs vi) Transport charges

1

-

-

... More
RO Booster pump motor cable replacement - Aluminium to Copper cable 3 core 50sqmm

15

-

-

... More
ASSET REPLACEMENT COST (For Seven Years) - Instrumentation Major Spares

-

-

-

... More
Reconditioning of ABB 800xA controller

5

-

-

... More
ASSET REPLACEMENT COST (For Seven Years) - Major items

-

-

-

... More
Online monitoring analyser as per TNPCB norms (intake, reject, potable water outlet) - ON LINE Monitoring system for Effluents Out let COD, BOD, TSS & PH to DCS

1

-

-

... More
Online monitoring analyser as per TNPCB norms (intake, reject, potable water outlet)- TNPCB data link charges for ETP with Hardware and software by picking the data from DCS

1

-

-

... More
Incorporation of outfall Analyser to SCADA (cable, Power Cable, Canopy, Structural Frame support for transmitter and fixing, the Analog

1

-

-

... More
Windows 7 upgradation (DCS) - HMI upgradation (including PC hardware and n/w components) along with site support services for upgrade, project management and commissioning

1

-

-

... More
Laboratory Instruments

-

-

-

... More
TOC Analyzer for analyzing sea water sample

1

-

-

... More
Dump valve provision for RO SKIDS including 10" Butterfly valves, HDPE Pipe, SS316 L 250 mm pipe, SS316 L Flange for 250 mm pipe etc complete

1

-

-

... More
Painting (Twice in 7 years)

-

-

-

... More
Painting of Reject Water Tank

2

-

-

... More
Painting of Fire Water Tank

2

-

-

... More
Painting of RO Tank (2Nos)

2

-

-

... More
Painting of UF Tank (2Nos)

2

-

-

... More
Painting of civil structures- (2 times in 7 years)- Colour washing one coat ; white washing two coats & Distembering (oil bound) two coats for old works as per standard specifications

2

-

-

... More
Laying of Bituminous Road - Mixing, processing in portable hotmix plant and laying coated bituminous macadam to a consolidated thickness of 50mm using graded aggregate of 40mm IRC size BG metal 0.24m3 20mm IRC size BG metal 0.309 cu.m.10mmIRC BG metal 0.137m3 and bitumen of appropriate grade 36.60Kg/10sqm over prepared surface including consolidation by power roller; Providing tack coat with appropriate grade of bitumen using 5 kg per 10 sq.m. including melting applying over the WBM/ Metalled surface etc. Complete

13333.14

-

-

... More
Acid/Alkali chemical house floor repair work i) Supply Of Acid / Alkali Resistant BRICKS Of Size (230x115x75mm) Thick IS4860 Conforming class I; ii) Supply of One coat A.R.Bitumen Primer,6mm Thick A.R. Bitumen Mastic Flooring & Coating, 6mm thick CNSL Resin Mortar bedding and Joint filling, pointing with (6mmx75mm) Depth CNSL Resin Mortar including Chemical material etc.; iii) Labour Charges For One coat A.R. Bitumen Primer, 6mm Thick A.R. Bitumen Mastic Flooring & Coating, 6mm thick CNSL Resin Mortar bedding, and Tile Fixing, Joint filling, pointing with (6mmx75mm)Full Depth CNSL Resin Mortar ; iv) Supply Of Acid / Alkali Resistant PELICAN Tiles Of Size (100x200x20mm) Thick IS4457.; v)Supply of One coat A.R.Bitumen Primer,6mm Thick A.R. Bitumen Mastic Flooring & Coating, 6mm thick CNSL Resin Mortar bedding and Joint filling, pointing with (4mmx20mm) Depth CNSL Resin Mortar including Chemical material etc., vi) Labour Charges For One coat A.R. Bitumen Primer, 6mm Thick A.R. Bitumen Mastic Flooring & Coating, 6mm thick CNSL Resin Mortar bedding and Tile Fixing, Joint filling, pointing with (4mmx20mm)Full Depth CNSL Resin Mortar .

1

-

-

... More
Plastering on damaged area - Plastering with cement mortar 1:3 (Crushed stone sand (M-sand)) for 20mm thick including curing, etc., complete. Area - Raw water sump, Dirty water sump, Sea water sump including labour charges etc.,

1

-

-

... More
FRP Gratings - GI Grating to be replaced with FRP Gratings

1

-

-

... More
Provision of Shelter for Lamella Clarifier and Flocculator Structural Steel Columns, rafter fabrication; Structural Steel installation Roof sheet 1 Job (Approximately 65X35m)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.