The AAI has issued a formal invitation for competitive bids for the Airports Authority Of India project, for Construction Of Sub Station And Ancillary Works For New Asr Collocated Mssr At Rhq Sr, Chennai Airport. Sh Provision Of 4 Nos. X 22 Tr Capacity Precision Air Conditioning And Split Type Air Conditioning Units And Its Associated Works Including Aicmc in Chennai, Tamil Nadu, with an estimated contract value of Rs. 1,32,08,365. The bid opening date for this tender is 28-05-2025 and the last date for bid submission is 19-06-2025. Interested bidders for Airports Authority Of India tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Airports Authority Of India - AAI Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 May 2025
Closing Date19 Jun 2025
Tender Amount₹ 1,32,08,365 
Notes
Download

Costs

Summary

Construction Of Sub Station And Ancillary Works For New Asr Collocated Mssr At Rhq Sr, Chennai Airport. Sh Provision Of 4 Nos. X 22 Tr Capacity Precision Air Conditioning And Split Type Air Conditioning Units And Its Associated Works Including Aicmc

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying & laying of condensate water drain pipe of ISI make PVC pipe having size of 40mm dia, 6kg/Cm² capacity along with 9 mm thick insulation for additional requirement for AC units i/c necessary clamps, screws, supports etc., complete etc. as required

100

-

-

... More
Supply and fixing of 19mm thick Class 'O' closed cell nitrile rubber insulation having density of 48 kg/cu.mtr in the wall and floor surface with suitable adhesive and preparing the surface free from dirt, dust for proper bonding of new insulation under the false flooring, etc. complete as reqd.

300

-

-

... More
Supply and fixing of Aluminium powder coated floor grills with control dampers as required

10

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

10

-

-

... More
SH-II : SITC of Unitary Air-Conditioners and Misc items

-

-

-

... More
Supply, Installation, Testing and Commissioning of 2.0 TR (nominal capacity), High wall mounted, Inverter Split type Air-conditioner with BEE star rating 5, consisting of non-ductable type indoor units (fan coil) with cord less remote control and one number out door unit comprising of compressor, cooling fan, copper condensing coil suitable for operation on single phase, 230 +/- 10% volts, 50 HZ, AC supply including installing the indoor (fan coil) unit and outdoor unit on wall on suitable stand, providing and fixing insulated copper piping (suction and discharge) and electrical connections with flexible copper cable of suitable size as per manufacturer's recommendations, between the indoor and outdoor units up to a length of 3 (three) meters, wrapping the insulated refrigerant line with white wrapping tape, providing drain piping (up to 3 meter length), drilling the hole on wall, making good the opening after installation including first charge of refrigerant etc. complete as required.

7

-

-

... More
Supply, Installation, Testing and Commissioning of 1.5 TR (nominal capacity), High wall mounted, Inverter Split type Air-conditioner with BEE star rating 5, consisting of non-ductable type indoor units (fan coil) with cord less remote control and one number out door unit comprising of compressor, cooling fan, copper condensing coil suitable for operation on single phase, 230 +/- 10% volts, 50 HZ, AC supply including installing the indoor (fan coil) unit and outdoor unit on wall on suitable stand, providing and fixing insulated copper piping (suction and discharge) and electrical connections with flexible copper cable of suitable size as per manufacturer's recommendations, between the indoor and outdoor units up to a length of 3 (three) meters, wrapping the insulated refrigerant line with white wrapping tape, providing drain piping (up to 3 meter length), drilling the hole on wall, making good the opening after installation including first charge of refrigerant etc. complete as required.

8

-

-

... More
Supply and Installation of Copper pipe for the following capacity Air conditioners including suction and delivery copper pipes with all accessories such as insulation, power & control cabling, etc., complete as required

-

-

-

... More
For 2 TR Split Air conditioner (beyond 3 meters per Split AC unit)

35

-

-

... More
For 1.5 TR Split Air conditioner (beyond 3 meters per Split AC unit)

40

-

-

... More
SITC of following capacity voltage stabilisers with copper wound coil having range of 170 to 270 voltage single phase, 50 Hz AC supply i/c necessary fixing arrangements, clamps, screws, metal clad top, connecting 3 core cable of 1 metre length, complete etc. as required.

-

-

-

... More
5 KVA stabilizer for 2 TR Spilt AC

7

-

-

... More
4 KVA stabilizer for 1.5 TR Spilt AC

8

-

-

... More
Supplying & laying of condensate water drain pipe of ISI make PVC pipe having size of 40mm dia, 6kg/Cm² capacity along with 9 mm thick insulation for additional requirement for AC units i/c necessary clamps, screws, supports etc., complete etc. as required

75

-

-

... More
SH: II -All Inclusive Comprehensive Maintenance Contract (AICMC) of 4 X 22 TR PAC

-

-

-

... More
All Inclusive Comprehensive Maintenance (AICMC) of 04 Nos. 22 TR Precision Air-Conditining (PAC) units as mentioned at Item No. 1.01 to 1.06 of SH:I installed in alternate MSSR Building equipment room including replacement of all Mechanical, Electrical, Eelctronic spares and consumables as and when required to keep the system 100% service condition, providing full support during breakdown & trouble shooting, programming, carrying out MONTHLY routine maintenance checks, preventive and breakdown maintenance etc. as required as per good engineering practices, recommendations of the respective Original Equipment Manufacturer (OEM) and as per the instructions of Engineer-In-Charge for maintaining the systems. This includes keeping the system in acceptable functional and serviceable state etc. as specified including cost of all spare parts and submission of monthly maintenance service records and Reporting etc., as required.

-

-

-

... More
First Year after Completion of 02 (Two) year DLP (Considered 4% of SITC Cost of item No. 1.01 to 1.06)

1

-

-

... More
Second Year after Completion of 02 (Two) year DLP (Considered Yearly 5% cumulative enhancement on 1st year AICMC Rate)

1

-

-

... More
Third Year after Completion of 02 (Two) year DLP (Considered Yearly 5% cumulative enhancement on 2nd year AICMC Rate)

1

-

-

... More
Fourth Year after Completion of 02 (Two) year DLP (Considered Yearly 5% cumulative enhancement on 3rd year AICMC Rate)

1

-

-

... More
Fifth Year after Completion of 02 (Two) year DLP (Considered Yearly 5% cumulative enhancement on 4th year AICMC Rate)

1

-

-

... More
Sixth Year after Completion of 02 (Two) years Defects Liability Period (DLP) (Considered Yearly 5% cumulative enhancement on 5th year AICMC Rate)

1

-

-

... More
Seventh Year after Completion of 02 (Two) years Defects Liability Period (DLP) (Considered Yearly 5% cumulative enhancement on 6th year AICMC Rate)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.