Water Resources Department Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 4,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_WRDAS_105683_3Bid Award Id
ViewTender No
NIT No.2/18-19 of EE WRD JodhpurTender Authority
Water Resources Department ViewPurchaser Address
-Website
http://http://water.rajasthan.gov.in/wrd
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
12 Way
10
11715
1171.5
... More
GI pipe 2000 mm long, 80 / 40 mm, Terminal 12 mm GI Strip
8
78000
9750
... More
Triple pole MCB
-
-
-
... More
S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required.
-
-
-
... More
High frequency electronic ballast 18/36 watts for FTL
3
1725
575
... More
40 A to 63 A rating
1
1515
1515.8
... More
With Thermal Magnetic release
-
-
-
... More
S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required.
-
-
-
... More
Double pole MCB
-
-
-
... More
4 Way
1
2002
2002
... More
11 KV End Termination Kit Indoor type
-
-
-
... More
36/40 Watts
6
810
135
... More
3 core 120/150/185/225 Sq.mm
1
5000
5000
... More
11 KV Straight Through Joint Kit
-
-
-
... More
Medium point (up to 6 mtr.)
99
33462
338
... More
3 core 185.0 Sq.mm
15
18990
1266
... More
P & F vacuum pressure impregnated copper ballast suitable for HPMV / HPSV / Metal halide lamp luminaire as required.Gr-1
-
-
-
... More
3.5 core
305
91195
299
... More
For HPMV lamp
-
-
-
... More
Long point (up to 10 mtr..)
54
25596
474
... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.Gr-1
-
-
-
... More
Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
-
-
-
... More
P & F Fluorscent tube rod in existing fixtures as required,Gr-1
-
-
-
... More
P & F of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current , conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.
-
-
-
... More
SF of Current Transformer , with all necessary support in existing panel including connection etc. as required .
-
-
-
... More
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Gr-A1
-
-
-
... More
SITC of microprocessor based three phase sensing power factor correction relay having following sensing capacity secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, metering facility as required.
-
-
-
... More
P & F Ballast for existing FTL / CFL fixture as required. Gr-1
-
-
-
... More
Double door (Three phase)
-
-
-
... More
4 core
304.6
51782
170
... More
sensitivity up to 50 milli Amp
1
20648
20648
... More
Double door (single phase)
-
-
-
... More
50.0 Sq.mm
-
-
-
... More
6 A to 32 A rating
141
23420
166.1
... More
P & F Capacitors for power factor improvement in existing HPSV/ HPMV/ Metal halide lamp fixture as required.Gr-1
-
-
-
... More
250 Watt
5
7500
1500
... More
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.
-
-
-
... More
from 200 / 5 to 400/5 Ratio , 10 VA , class 1 accuracy
3
969
323
... More
6.0 Sq.mm
-
-
-
... More
25 mm
682
28644
42
... More
P & Laying XLPE insulated IS:7098/II/85 of Group1 and approved make H.T.cable for working voltage 11 K.V.Earthed direct in ground including excavation of 30cmx100cm size trench, 25cm layer of river sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size.Gr-1
-
-
-
... More
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , Painting etc. as required.Gr-1
200
16800
84
... More
Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's accessories, 18 SWG 175 mm x 100 mm x 60 mm M.S. box with earth terminal, 6 A switch, 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.Gr-1
-
-
-
... More
Four pole MCB
-
-
-
... More
Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes.
-
-
-
... More
3 core 120/150/185/225 Sq.mm
2
30000
15000
... More
Red/yellow/Green colour
30
4500
150
... More
33 mfd
5
2250
450
... More
12 to 14 stage
-
-
-
... More
With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating
-
-
-
... More
Short point (up to 3 mtr.)
54
11610
215
... More
up to 6 KVAR
2
2200
1100
... More
40 mm Dia.
4
2000
500
... More
P & F Normal / High Output High pressure sodium vapour/ Metal halide / Halogen lamp as required.Gr-1
-
-
-
... More
Triphosphor coated (minimum 5 star rating)
-
-
-
... More
HPSV Tubular lamp High Output
-
-
-
... More
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator)
10
27520
2752
... More
250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
2
37978
18989
... More
10.0 Sq.mm
-
-
-
... More
3.5 x 50.0 sq.mm
2
264
132
... More
On board
45
4050
90
... More
Electrolytic grade Aluminium bus bar
12
5040
420
... More
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.
-
-
-
... More
40 A 63 A rating
1
1137
1137.4
... More
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.
-
-
-
... More
3 core
700
93100
133
... More
250 Watt 33200 Lumens
5
2850
570
... More
P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Gr-A1
-
-
-
... More
up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
4
25364
6341
... More
Single pole MCB
-
-
-
... More
3 x 6.0 sq.mm
20
1180
59
... More
6 A to 32 A rating
10
4411
441.1
... More
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.
-
-
-
Evaluation Notes How It Works ?