Rajasthan State Road Development And Construction Corporation Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan State Road Development And Construction Corporation Limited - RSRDC Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 May 2025
Closing Date27 May 2025
Tender Amount₹ 69,50,000 
Notes
Download

Costs

  • EMD

    ₹ 1,39,000
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 1,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
32 mm x 12 mm

202

64

-

... More
Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

0.00001

-

-

... More
10 A one way switch

200

55

-

... More
10 A bell push

50

110

-

... More
16 Amp. 2 Module switch With Led Indicator

60

147

-

... More
32 Amp. 2 Module switch With Led Indicator

60

369

-

... More
Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

0.00001

-

-

... More
6 A 3/5 pin shuttered socket

100

107

-

... More
6/16 A shuttered socket

50

176

-

... More
25 Amp. 2 Module Socket

100

228

-

... More
Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

0.00001

-

-

... More
1/2 Module

50

65

-

... More
3 Module

35

86

-

... More
4 Module

25

89

-

... More
6 Module

10

114

-

... More
8 Module

10

155

-

... More
10 Module

10

198

-

... More
12 Module

20

214

-

... More
Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

0.00001

-

-

... More
1-2 Module

50

86

-

... More
3 Module

35

120

-

... More
4/5 Module

35

140

-

... More
6 / 8 module

20

204

-

... More
10 / 12 module

15

286

-

... More
Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
Four pole 100/300 mA sensitivity

0.00001

-

-

... More
63 A rating

60

4296

-

... More
Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
4 pair

2000

33

-

... More
Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
5 step fan regulator 2 Module 360 dgree rotating

75

398

-

... More
Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
RJ-11 telephone jack single line

100

142

-

... More
T.V. coaxial socket

50

159

-

... More
Blanking plate

501

22

-

... More
Modular MCB 6 A to 32 A DP

100

461

-

... More
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

4500

49

-

... More
Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
Cat 6, Un-sheilded Information Outlet

100

398

-

... More
Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
Single Aperture

100

81

-

... More
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord

0.00001

-

-

... More
2 Mtr

350

290

-

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

80

580

-

... More
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

250

128

-

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
Single pole MCB (With B/C curve tripping Characteristics)

0.00001

-

-

... More
6 A to 32 A rating

800

187

-

... More
Four pole MCB (With B/C curve tripping Characteristics)

0.00001

-

-

... More
50/63 A rating

90

1745

-

... More
Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating  copper bus bar, neutral bars with shrouds,  earth bar , color coded interconnecting wire set  of suitable rating and din bar,masking sheet,  making internal DB  terminations with copper lugs, ferrules,  detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
6 Way(8+18)

17

9425

-

... More
8 Way(8+24)

16

10580

-

... More
12 Way(8+36)

17

13984

-

... More
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp.  insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set  of suitable rating and din bar,masking sheet,  making internal DB  terminations with copper lugs, Ferrules,  detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
Metal door (Three phase) IK-09 and IP-43 with Metal end box

0.00001

-

-

51

5980

-

... More
Labour charges for removing and refixing of Ceiling fan/ Exaust fan from site

501

67

-

... More
Fans with Removing & Refixing at Suitable Location

500

107

-

... More
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

500

135

-

... More
NON BSR

0.00001

-

-

... More
Supply, Installation, Testing & Comissioning of High Speed HDMI Cable 3Mtr; HEC Support, ARC, 3D, 4K@60Hz, HDMI Gold Plated 2xHDMI 19- pin male Connectors; flexible Double shielded, PVC jacket 28 AWG cable, Black; High-speed Ethernet, bi- directional networking at up to 100 Mbps; Up to 18 Gbps at 600 MHz bandwidth; Standards and Certifications: CL3, CM, UL 20276, ISO 9002; And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur .

25

7590

-

... More
Supply, , Installation, Testing & Comissioning of High Speed HDMI Cable 5Mtr; HEC Support, ARC, 3D, 4K@60Hz, HDMI Gold Plated 2xHDMI 19- pin male Connectors; flexible Double shielded, PVC jacket 28 AWG cable, Black; High-speed Ethernet, bi- directional networking at up to 100 Mbps; Up to 10.2 Gbps at 340 MHz bandwidth; Standards and Certifications: CL3, CM, UL 20276, ISO 9002; And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur .

25

9876

-

... More
S&F following sizes Flexible steel conduit Tube With saddles,Base Type clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

0.00001

-

-

300

122

-

250

156

-

200

214

-

... More
Supplying and drawing FRLS PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

... More
3x 1.5 sq.mm

12000

69

-

... More
2 x 2.5 sq. mm. + 1x1.5sqmm

5500

89

-

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

4000

134

-

... More
2 x 6.0 sq. mm. + 1 x 4.0 sq. mm.

2000

204

-

... More
1 x 6.0 sq.mm

400

78

-

... More
4 x 6.0 sq.mm

400

303

-

... More
1 x 10.0 sq.mm

300

149

-

... More
4 x 10.0 sq.mm

310

584

-

... More
S&F following sizes (dia.) of ISI marked virgin material HMS fire-retardant heavy-duty ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

0.00001

-

-

2000

44

-

6000

60

-

1000

92

-

421

187

-

... More
Removing and refixing of Audio Video Equipment , Accessories Of VC Setup, CCTV/EPABX or any other electromechanical systems. With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors and Registrar Office ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification.

25

7000

-

... More
Removing And refixing Airconditioner accessories like Indoor unit, OutDoor unit,VRV System, AHU System, FSU System, Duct System Grill With New Angle, Fastener Supply as Per NBC's Norms refrigerant piping , connecting cables , drain pipe etc. including shifting of dismentaled material to store complete as required. With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors and Registrar Office ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification.

25

6500

-

... More
Removing And refixing Fire Fighting Accessories Like M.S Pipe Sprinkler, Hydent complete as required. With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors and Registrar Office ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification.

25

6500

-

... More
Removing And refixing ,FireDetection Accessories , Fire Fighting Accessories Like Fire Detector , Armoured Cable, MS Pipe RI, Hooter, PA SystemRelated to Fire Protection complete as required. With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors and Registrar Office ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification.

25

4500

-

... More
Removing /removing and refixing of Electric Accessories Like Ceiling fan, Exaust fan, Wall Fan, Down light, Tubelight, 2x2 Panel Light, And Other Items Which Is not Included But Connetced At Site and Refixing With Good and Running Condition With Issue Safty Certificate as per requirement. With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors and Registrar Office ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification.

25

2500

-

... More
Dismentaling of Electric Accessories Like Ceiling Rose,Switch, Plug Point , MS Switch box, Switch Plate, Conduiting(PVC/MS),Wire Etc With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors and Registrar Office ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification.

25

1200

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.