Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan Rajya Vidyut Prasaran Nigam Limited - RVPN Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date25 Mar 2025
Closing Date5 May 2025
Tender Amount₹ 24,89,834 
Notes
Download

Costs

  • EMD

    ₹ 49,797
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
i)In case electricity is made available by RRVPN without charges

70

11230

786100

... More
ii) 33 KV or 11 KV Marshelling Kiosk

7

192

1344

... More
(b) 4.0 sq. mm for any number of cores

1500

14

21000

... More
(ii) Hard rock (with blasting subject to permission or without blasting)

1000

59

59000

... More
Erection of Current Transformer / Potential Transformer / Capacitive voltage Transformer / Series Reactor / Residual Voltage Transformer /Neutral Current Transformer with clamps & connectors, on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc.,complete in all respects.

-

-

-

... More
b) With single Earth Blade

7

1364

9548

... More
(iii) 33 KV

18

317

5706

... More
(a) 19 sq. mm unarmoured control cables

540

44

23760

... More
Laying and termination of cable Control Cable i) Laying of P.V.C. insulated unarmoured/ armoured control cables of 1.1 KV grade with copper conductor in cable trench as per specification as required, including transportation of cable drums from site store to location, laying in cable trenches cutting to required length, placing them on cable racks/ cable trays/cable batten dressing including removing and re-fixing trench covers as required, making necessary connections, testing cable making on both the terminating ends, etc. as required for connections, testing cable making on both the terminating ends, etc. as required for all sizes from 2c x 2.5 sq. mm to20 c x 2.5 sq. mm,4 c x 4 sq. mmand 4 c x 6 sq. mm

-

-

-

... More
(i) 132 KV CT/PT/CVT

21

1415

29715

... More
JUMPERS of ACSR conductor(3 nos. Y-type) between bus to equipment or between equipment to equipment bus to bus, including transportation of conductor, disc Insulators and hardware from site stores to locations, cleaning and assembly of disc insulators as required along with fittingof suspension hardware and erection as required, cutting required length of conductor, making connections, fixing of spcers T-clamps as required,tighting of clamps/ connectors,dressing etc.for three phases. (Per Jumper Basis)

-

-

-

... More
ii) 132 KV

3

665

1995

... More
(c) 25 sq. mm unarmoured control cables

120

67

8040

... More
i) Any Conductor

425

111

47175

... More
STRINGING of Earth wire(size 7/3.15 min or 7/4.00 mm) including transportation of earthwire, tension hardwares, etc., from site store to locations, laying and cutting required length of earthwire, fitting of bolted type or compression type hardware as made available,stringing of earthwire between structure peaks with spacified sag and tension,jumpering and connection earth bonds,for single earth wire.

70

292

20440

... More
Laying of earthing risers of 50x6mm/50x10mm/50x12mm size M.S.Flat at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S.Flat from site store to locations,prepration of risers ,bending as per the requirement fixing on and welding /bolting to equipment/ structure and peaks of structures.laying in the trench, welding to the earth mesh of M.S. Rod as per drawing including welding of extra length of M.S. Flat if required application of bitumen compound and covering bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint for the type of soil prevalent at0.80 meter below top level of foundations (M.S, Rod of above sizes & M.S. Flat as required shall be made available by RVPN) a) In case electricity is made available by RVPN without charges.

-

-

-

... More
Erection of Post Insulators on already erected structures including transportation of P.I.'s., nuts & bolts, clamps & connectors, etc. from site store to locations, fabrication of base frame & assembly if required, fixing of clamps, etc.

-

-

-

... More
(ii) 132 KV

9

1422

12798

... More
Erection of 220 KV or 132 KV Circuit Breakers including transportation of equipment, structure members, nuts & bolts, clamps & connectors, etc. from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support columns/ poles, mechanism box /other accessories etc. on support structure as per manufacturer’s drawings, fitting of SF6 gas pipe line, fabrication of air/oil pipe line as required, electrical wiring from pole to control cubicle, fixing of terminal connectors, etc. but excluding commissioning of CB. ii)132 KV

4

15223

60892

... More
ERECTION OF STEEL STRUCTURE ERECTION OF SUB-STATION STEEL STRUCTURES columns, beams, lighting mast and equipment structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members,nuts & bolts, washers, etc. from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. ( Maximum height of structures up to 20 meters)

110

2321

255310

... More
Erection of Wave trap on already erected structure beam, includingtransportation of wave trap, disc insulators, hardware, clamps and connectors,etc. from site store to locations, cleaning & assembly of disc insulatorsalongwith fitting of suspension arrangement and erection, fixing of terminalconnectors, etc. ii) 132 KV

2

599

1198

... More
Erection of Isolators (Motorised/Non motorised) on already erected steel structure including transportation of base frame. P.I. 's. contacts. Mechanism-box, clamps & connectors, etc. from site store to locations. Minor fabrication as required, and fixing of terminal connectors etc, adjustment/alignment of isolator and its earth blade, if provided, for their smooth operation and final adjustment if required after jumpering including erection of PI. ii) 132 KV iii) 33 KV

-

-

-

... More
iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc.

6

632

3792

... More
i) 220 KV or 132 KV Marshelling Kiosk

6

374

2244

... More
Erection of 33 KV or 11 KV Circuit Breakers including transportation of equipment, structure members, nuts & bolts, clamps & connectors, etc. from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of poles, mechanism box, etc. on support structure as per manufacturer’s drawings, fitting of terminal connectors, etc. but excluding commissioning of CB. i) 33 KV or 11KV Outdoor Type ( VCB / SF 6 )

8

7404

59232

... More
ii) Fixing of power cables in position with single compression, heavy duty nickel plated brass cable glands as per IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plate, etc., including cost of cable gland if required, for each end of cable of size.

-

-

-

... More
ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS:12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates , etc. as required & including cost of cable glands for each cable gland of size

-

-

-

... More
ii) 110 Volt DC, 200 AH

1

1265

1265

... More
(ii) 33 KV CT/PT

27

532

14364

... More
iii)Termination of wires of cables with aluminium conductors using ISI marked tubular aluminium terminal ends as per IS: 8309 duly crimped with crimping tool, including making cable ends ready for crimping and providing insulation tape with colour code, dressing of wires, etc., including cost of terminal ends if required, for each end of cable (4 nos. per end) for the following size of cables.

-

-

-

... More
Laying of earth mesh with 25mm/28mm.dia. M.S.Rod at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and back filling of the same, transportation of M.S.Rod from site store to locations, welding of M.S. Rod to M.S. Rod along the length at crossing and with earth electrodes as per drawing application of bitumen compound an d covering bitumen impregnated tape on all welded joints for the type of soil prevalent at0.80 meter below top level of foundations (M.S, Rod of above sizes & M.S. Flat as required shall be made available by RVPN) a) In case electricity is made available by RVPN without charges.

-

-

-

... More
(ii) Hard rock (with blasting subject to permission or without blasting)

1500

54

81000

... More
ii) Any Double Conductor

4

1758

7032

... More
a) Without Earth Blade

11

2596

28556

... More
Placing /Driving of earth electrode of 25/28mm dia M.S.Rod of length 7.50 metres(approx.) to a depth of 8.00 metres from the top level of foundations, including drilling of 200mm dia earth pit having throughout bore of 200 mm dia to adepth of 8.00 meters from the top level of foundations in all types of rocks by DTH system and over burdan,including back filling of pit with Bentonite slurry (with cost of Bentonite slurry), including its preparation transportation of M.S.Rod and Bentonite from site store to locations, cutting of M.S. Rod to desired length, welding of earth electrode to earth mesh of M.S. Rod as per drawing application of bitumen compound and covering bitumen impregnated tape on all welded joints, (M.S, Rod of above sizes & M.S. Flat as required shall be made available by RVPN)

-

-

-

... More
(a) 2.5 sq. mm for any number of cores

2100

11

23100

... More
Erection of Battery Charger complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, etc.

-

-

-

... More
BATTERY SET Assembly, erection and commissioning of Lead Acid Battery Set including transportation of cell, battery stand, nuts & bolts etc from site store to battery room assembly of stand placing the cells on stand making their interconnection, initial charging, discharging and final charging as per procedure recommended by battery manufacturer. a). If electricity is available & arranged by RVPN without charges

-

-

-

... More
ii) Any Conductor

11

1165

12815

... More
ETC-33 KV XLPE CABLE 1CX630 MM AL

1500

100

150000

... More
(i) Any Soil, soft rock other than hard rock

4500

25

115650

... More
i) Transformers received oil filled

1

42089

42089

... More
ii) 110 Volt DC, 200 AH

1

24621

24621

... More
d) 3 ½ core × 300 sq. mm.

150

53

7950

... More
iv) L.T. Panel

1

1739

1739

... More
g.) 75/76mm for 3.5 core X 300sq.mm. with material

2

442

884

... More
Erection of Lightening Arrestor on already erected steel structures, including transportation of Lightening Arrestor, clamps & connectors, surge counter, etc. from site store to locations, fabricatioon of base frame, fixing of terminal connectors, surge counter, tighting of nuts & bolts complete in all respect.

-

-

-

... More
Erection of Sub-Station Equipments i) Erection of 33/0.4 KV or 11/0.4 KV Station transformer up to 500 KVA on existing masonary platform including transportation of transformer accessories from site store to location, erection of Horn Gap fuse set,jumpering from isolator to Horn Gap to transformer.

1

3967

3967

... More
Errection of Marshalling Kiosk / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respects including transportation to site store to location, palcing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc.

-

-

-

... More
iii) 33 KV

12

75

900

... More
ii) Duplex Panel

4

1265

5060

... More
Erection of 132 KV Class EHV Transformer (tank already placed on foundation with wheels), including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, main & OLTC conservators, radiators, equalizing pipe line, marshalling kiosk, etc. as per manufacturer's drawing, preparation of oil, oil filling, dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e.g., Buchholz relay, MOLG, OSR, etc. to marshalling kiosk, etc., but excluding testing & commissioning of transformer.a) if Electricity is made available by RVPN

-

-

-

... More
iii) Termination of wires of cables with copper conductor using copper terminal ends(pin or ring type as required of Dowell's or equivalent make as approved by the Engineer-In-Charge) duly crimped with crimping with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires, etc. as required including cost of terminal; ends for all wires for each cable at both ends for cables of the following sizes.

-

-

-

... More
(a) Unarmoured control cables

13150

5

65750

... More
a) Without Earth Blade

23

916

21068

... More
b) With single Earth Blade

2

3045

6090

... More
L.T. Power Cables i) Laying of P. V. C. insulated and P. V. C. sheathed armoured / unarmoured L. T. power cable of 1.1 KV grade with aluminium conductor as per IS: 1255 in ground / cable trench / wall / surface including transportation of cable drums from site store to locations and excavation of 30 cm. × 75 cm. size trenches, providing 25 mm thick under layer of sand & 2nd class brick covering & refilling earth in remaining portion, fixing as per approved / available spacing by means of M. S. U – clamps, etc. as per specification as required, including making necessary connections & testing, etc., as required, of the following sizes.

-

-

-

... More
(i) Any Soil, soft rock other than hard rock

3000

28

85200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.