The RVPN has issued a formal invitation for competitive bids for the Rajasthan Rajya Vidyut Prasaran Nigam Limited project, for Construction Of 220 Kv Gss Dariba in Rajsamand, Rajasthan, with an estimated contract value of Rs. 28,94,007. The bid opening date for this tender is 16-04-2025 and the last date for bid submission is 10-05-2025. Interested bidders for Rajasthan Rajya Vidyut Prasaran Nigam Limited tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Rajasthan Rajya Vidyut Prasaran Nigam Limited - RVPN Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Apr 2025
Closing Date10 May 2025
Tender Amount₹ 28,94,007 
Notes
Download

Costs

  • EMD

    ₹ 58,000
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Summary

Construction Of 220 Kv Gss Dariba

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Work of Laying of Earth Mesh Earthing of Sub Station Structure and Equipment Erection of Steel Structure and equipment, Stringing of Bus Bar and Earth wires Jumpers Installation of Control panels cable laying and termination of cable at 220 KV GSS DARIBA
AS PER TENDER DOCUMENTS
AS PER TENDER DOCUMENT
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Placing of earth electrode of 25 /28 mm dia M.S. Rod of length 7.50 meters (approx.) to a depth of 8.00 meters from the top level of foundation including drilling of 200 mm dia earth pit having a throughout bore of 200 mm dia to a depth of 8.00 metres from the top level of the foundations in all types of rocks by DTH system and overburden including back filling of pit with Bentonite Slurry (with cost of Bentonite slurry) including its preparation transportation of M.S Rod and Bentonite from site store to location cutting of M.S Rod to desired length welding of earth electrode to earth mesh of M.s Rod as per drawing application of bitumen compound and covering with bitumen impregnated tape on all welded joints (M.S. Rod of above sizes & M.S Flat as required shall be made available by RVPN). (a) In Case electricity is made available by RVPN without Charges.

40

11230

449200

... More
Erection of Control & Relay Panels complete in all respects including transportation to site store to control room, palcing on foundation / cable trench as per layout,interconnection between Control & Relay panels and with existing panels and with with existing panels, fixing of side /top covers and doorsearthling to existing Earth strip in control room, connection of bus wiring to existing panel and between control and relay panels as required ii) Duplex Panel

6

1265

7590

... More
(e) 32 sq. mm unarmoured control cables

50

96

4800

... More
ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS:12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates , etc. as required & including cost of cable glands for each cable gland of size (a) 19 sq. mm unarmoured control cables

500

44

22000

... More
iv) LT Panel

1

1739

1739

... More
Errection of Marshalling Kiosk / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respects including transportation to site store to location,palcing on foundation / cable trench as per layout, preparing for grouting etc. i) 220 KV or 132 KV Marshelling Kiosk

8

374

2992

... More
c) With Double Earth Blade

2

5557

11114

... More
132 KV Erection of Wave trap on already erected structure beam, including transportation of wave trap, disc insulators, hardware, clamps and connectors, etc. from site store to locations, cleaning & assembly of disc insulators alongwith fitting of suspension arrangement and erection, fixing of terminal connectors for 132 kv........ i) 220 KV

4

807

3228

... More
iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc.

8

632

5056

... More
(b) Armoured control cables

250

6

1500

... More
(ii) Hard rock (with blasting subject to permission or without blasting)

2500

54

135000

... More
LAYING AND TERMINATION OF CABLES Control Cables i) Laying of P.V.C. insulated unarmoured/ armoured control cables of 1.1 KV grade with copper conductor in cable trench as per specification as required, including transportation of cable drums from site store to location, laying in cable trenches cutting to required length, placing them on cable racks/ cable trays/cable batten dressing including removing and re-fixing trench covers as required, making necessary connections, testing cable making on both the terminating ends, etc. as required for connections, testing cable making on both the terminating ends, etc. as required for all sizes from 2c x 2.5 sq. mm to20 c x 2.5 sq. mm,4 c x 4 sq. mmand 4 c x 6 sq. mm (a) Unarmoured control cables

30004

5

150020

... More
Painting Aluminium painting of new steel structures at the GSS including paint and painting brush, emery paper, cloth & solvent, etc. The surface shall be first rubbed free of dust or any other deposits on erected M. S. steel structures & beams. One coat of red oxide paint shall be applied after carrying out cleaning and allowed to dry. Thereafter two coats of Aluminium paint shall be applied. Each subsequent coat shall be applied only after the previous coat has dried. The paint used shall be out of the following recognized manufacturers only, namely, Asian / Nerolac / Berger / Johnson Nicholson / Dulux

250

35

8750

... More
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers ( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix! Design Mix.(The rates are as per PWD BSR 2014- Jaipur.)

25

4378

109450

... More
ii) Hard rock (with blastina subiect to permission or without blastina)

5

932

4660

... More
JUMPERS of ACSR conductor(3 nos. Y-type) between bus to equipment or between equipment to equipment bus to bus, including transportation of conductor, disc Insulators andl hardware from site stores to locations, cleaning and assembly of disc insulators asrequired along with fitting of suspension hardware and erection as required, cuttingrequired length of conductor, making connections, fixing of spacers & spacer, T-Clamps as required tightening of clamps / connectors, dressing etc for three phase i) Any conductor

150

111

16650

... More
Laying or earthling risers of 50 x 6 mm /50 x 10 mm / 50 x 12 mm size M.S Flat at a depth of 0.80 meter from top level of foundation including excavation of trench of required depth and backfilling of the same transportation of M.s. Flat from site store to locations, preparation of risers bending as per requirement (after heating if necessary), fixing on and welding/ bolting to equipment structures and peaks of structures, laying in the trench, welding to the earth mesh of M.S rod as per drawing including welding of extra length of M.S Flat if required ,application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint for the type of soil prevalent at 0.80 meter below top level of foundations (M.S Rod of above sizes & M.S Flat as required shall be made available by RVPN). (i) Any Soil, soft rock other than hard rock

2000

28

56800

... More
Erection of Isolators on already erected steel structure including transportation of base frame. P.I. 's. contacts. Mechanism-box, clamps & connectors, etc. from site store to locations. Minor fabrication as required, and fixing of terminal connectors, etc. adjustment/alignment of isolator andits earth blade if provided for their smooth operation and final adjustmentif required after jumpering. a) Without Earth Blade

10

4400

44000

... More
iii) Termination of wires of cables with copper conductor using copper terminal ends(pin or ring type as required of Dowell's or equivalent make as approved by the Engineer-In-Charge) duly crimped with crimping with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires, etc. as required including cost (a) 2.5 sq. mm for any number of cores

2700

11

29700

... More
Erection of 220 KV Class EHV Transformer (Gas filled tank already placed on foundation with wheels), including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated pipe line, radiators, fans, pump, main & OLTC conservators, equalizing pipe line, marshalling kiosk, etc. as per manufacturer's drawing, preparation of oil, oil filling, dehydration of transformer along with cooler bank & diverter switch (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e.g., Buchholz relay, MOLG, OSR, Fans, Pumps, Bushing C'T's etc. to marshalling kiosk, etc., but excluding testing & comrnissioninq of transformer. a) if Electricity is made available by RVPN (without charges)

1

128596

128596

... More
Laying of earth mesh with 25 mm/28 mm dia M.s road at a depth of 0.80 meter from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S. Rods from site store to location, welding of M.S. Rod to M.S. rod along the length at crossings and with earth electrodes as per drawing application of bitumen compound and covering with bitumen impregnated tape on all welded joints for the types of soil prevalent at 0.80 meter below top level of foundation (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN). (a). In case electricity is made available by RVPN without charges (i) Any Soil, soft rock other than hard rock

4200

25

107940

... More
b) With Single Earth Blade

1

3045

3045

... More
(ii) Hard rock (with blasting subject to permission or without blasting)

1000

59

59000

... More
Erection of 220 KV or 132 KV Circuit breakers including transportation of equipment, structure members, nut bolts, clamps & connectors, accessories from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required...... ii) 132 KV

2

15223

30446

... More
ERECTION OF SUB STATION EQUIPMENTS Erection of Current Transformer / Potential Transformer / Capacitive voltage Transformer 1 Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps &connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc., complete in all respects. ii)132 KV CT/PT/CVT

9

1415

12735

... More
Placing / Driving of earth electrode of 25 / 28mm dia. M. S. Rod of length 3.30 meters (approx.) to a depth of 3.80 meters from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M. S. Rod from site store to locations, cutting of M. S. Rod to desired length, preparation of one end as spike if necessary, welding of earth electrode to earth mesh of M. S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints. for the type of soil prevalent at 3.80 metres below top level of foundations (M. S. Rod of above sizes & M. S. Flat as required shall be made available by RVPN). i) Any soil,soft rock other than hard rock

20

273

5462

... More
Erection of Lightening Arrestor on already erected steel structures, including transportation of Lightening Arrestor, clamps & connectors, surge counter, etc. from site store to locations, fabricatioon of base frame, fixing of terminal connectors, surge counter, tightening of nuts&bolts etc. complete in all respect ii)132 KV

3

1422

4266

... More
Bus-Bar Work Stringing of 220 KV , 132 KV, 33 KV & 11 KV Bus B of ACSR Conductor, including transportation of conductor, disc insulator and tension hardware from site stores to location, laying and cutting requiredlengthof conductor cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available (compression machine shall be provided by RVPN on rent free basis) making up at one end stringing of conductors between the beams with specified sag and tension also equalizing sag and fitting spacers and spacer T-Clamps for twin conductor for three phases of conductors in each bus-section. i) Any Single Conductor

12

1165

13980

... More
Erection of Lightening Arrestor on already erected steel structures, including transportation of Lightening Arrestor, clamps & connectors, surge counter, etc. from site store to locations, fabricatioon of base frame, fixing of terminal connectors, surge counter, tightening of nuts&bolts etc. complete in all respect i) 220 KV

9

1996

17964

... More
a) Without Earth Blade

6

2596

15576

... More
b) With Single Earth Blade

2

4899

9798

... More
Erection of 220 KV or 132 KV Circuit breakers including transportation of equipment, structure members, nut bolts, clamps & connectors, accessories from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required....... i) 220 KV

4

19216

76864

... More
Bus-Bar Work Stringing of 220 KV , 132 KV, 33 KV & 11 KV Bus B of ACSR Conductor, including transportation of conductor, disc insulator and tension hardware from site stores to location, laying and cutting requiredlengthof conductor cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available (compression machine shall be provided by RVPN on rent free basis) making up at one end stringing of conductors between the beams with specified sag and tension also equalizing sag and fitting spacers and spacer T-Clamps for twin conductor for three phases of conductors in each bus-section. i) Any Double Conductor

12

1758

21096

... More
STRINGING of Earth wire(size 7/3.15 min or 7/4.00 mm) including transportation of earthwire, tension hardwares, etc., from site store to locations, laying and cutting required length of earthwire, fitting of bolted type or compression type hardware as made available (compressionmachine shall be provided by RVPN on rent free basis) making up at one end stringing of earth wire between structure peaks with specified sag and tension jumpering and connecting earth bonds for single earth wire.

70

292

20440

... More
Battery Set Assembly, erection and commissioning of Lead Acid Battery Set including transportation of cell, battery stand, nuts & bolts etc from site store to battery room assembly of stand placing the cells on stand making their interconnection, initial charging, discharging and final charging as per procedure recommended by battery manufacturer. i) 220 Volt DC, 400 AH

2

26285

52570

... More
Erection of Post Insulators on already erected structures including transportation of P.I.'s., nuts & bolts, clamps & connectors, etc. from site store to locations, fabrication of base frame & assembly if required, fixing of clamps, etc. ii) 132 KV

15

665

9975

... More
Erection of Post Insulators on already erected structures including transportation of P.I.'s., nuts & bolts, clamps & connectors, etc. from site store to locations, fabrication of base frame & assembly if required, fixing of clamps, etc. i)220 KV

36

883

31788

... More
ERECTION ON SUB-STATION STEEL STRUCTURES columns,beams,lighting mast and equipment, structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members, nuts & Bolts, washers etc. from site strore to location, their assembly placing on foundation fixing of template with foundation bolts as requires leveling and preparing for grouting as required but excluding grouting erection after grouting and tightening & punching nuts & bolts. (maximum height of structures up to 20 meters)

280

2321

649880

... More
f) Tendom

4

4899

19596

... More
iii) 48 Volt DC, 600/400/200 AH

2

1265

2530

... More
ERECTION OF SUB STATION EQUIPMENTS Erection of Current Transformer / Potential Transformer / Capacitive voltage Transformer 1 Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps &connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc., complete in all respects. i) 220 KV CT/PT/CVT

24

2529

60696

... More
(c) 25 sq. mm unarmoured control cables

200

67

13400



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.