Public Health Engineering Department Tender

... More
The PHED has issued a formal invitation for competitive bids for the Public Health Engineering Department project, for Rejuvenation Of Existing Pump House In Adarsh Colony Including Pumping Machinary, Electric Work With Civil Work At Urban Water Supply Schemes Shahpura Under Sub Division Shahpura,jaipur in Jaipur, Rajasthan, with an estimated contract value of Rs. 29,92,000. The bid opening date for this tender is 08-10-2019 and the last date for bid submission is 17-10-2019. Interested bidders for Public Health Engineering Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Public Health Engineering Department - PHED Tender

Opening Date8 Oct 2019
Closing DateCancelled
Tender Amount₹ 29,92,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
B Class 50 mm dia. In 6 mtr. Length

350

180250

515

... More
Makinhg holes in stone masonary wall upto 450 mm x 450 mm size and making good in CM 1:6.

3

396

132

... More
Providing and fixing of cast iron Dismentling Joint as per PHED specfications including cost of rubber flange gaskit and nut bolts complete as required for following sizes.

-

-

-

... More
Long point (up to 10 mtr..)

2

884

442

... More
Supply and fixing of rubber mating for pump house

30

84930

2831

... More
Size : 80 mm dia DI Resilient Seated Sluice Valve

4

40144

10036

... More
Providing and fixing of cast iron doubleNon Returns valves IS 14846/2000 specfications ( ISI marked ) of PN-1 Rating including cost of rubber flange gaskit and nut bolts complete as required for following sizes. With out tail piece

-

-

-

... More
P & F Star rated double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.

-

-

-

... More
Size : 125 mm dia DI dual plate check valve

1

12794

12794

... More
M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).

30

120112

4003.75

... More
125 mm

2

7760

3880

... More
Providing & lowering in tubewell ISI marked of GI Pipe “B class ( IS:1239 make) threaded and doubled flanged(welded) on both ends and two number 25x3mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.

-

-

-

... More
Long point (up to 10 mtr..)

2

904

452

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) PVC casing capping & it's accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.

-

-

-

... More
Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall in :

-

-

-

... More
Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc.

30

5730

191

... More
Supply of electric control feeder pannel comprising rewirable type 3 nos.fuses MCB ,(Make-L&T,SIEMENS/gec/cgl/c&s/HAVELLS OR ANY OTHER MAKE APPROVED BY TECHNICAL COMMITTEE RWSSMB time to time phase preventor ,suitable starting as per specification. Phase indicator,lighting ,arrangement etc complete suitable for 3 phase pump set,the penal should have space for energy meter (supplied by JVVNL),a bakelite sheet for 12mm thich shall be provieded for instlation for energy meter. All these equipment shall be housed by penal box made out from 18 gauge MS Sheet with powder coating .Penal size should be specified as per pump house requirment.made of angel as per requirment duly bolted/screwed with enclosure box having 4 legs each legs length 18" and double door including in built locking system. The legs should be enbeded in M-15 cement concrete plateform.Size of CC Plate Form should be equal or bigger than the base size of panel having height of at least 200mm from ground lavel. The operation of panel board should be suitable for on 240 volts .AC Supply the panel should have opening of suitalbe size in front ofspace of energy meter with glass for meter reading.

30

195000

6500

... More
Size : 150 mm dia DI Resilient Seated Sluice Valve

3

59445

19815

... More
Size: 6.0 Sqm 2 Core

30

3930

131

... More
12 mm thick.

100

11800

118

... More
1200 mm Sweep 5 Star rated

2

3792

1896

... More
(b) 6.00 Sq.mm 3 core flat / Round

2200

448800

204

... More
Short point (up to 3 mtr.)

3

696

232

... More
Size : 150 mm dia DI dual plate check valve

1

15994

15994

... More
Providing and fixing of DI Soft sheated Gate Valve per specfications including cost of rubber flange gaskit and nut bolts complete as required for following sizes.

-

-

-

... More
Medium point (up to 6 mtr.)

1

332

332

... More
Cement Mortar 1:6 (1-Cement:6-Sand).

20

60260

3013

... More
Size: 16.0 Sqm 4 Core

100

19100

191

... More
Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc. complete in all respects.

100

23700

237

... More
Size : 80mm

4

8996

2249

... More
P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as approved make, if any of group-I

-

-

-

... More
Medium point (up to 6 mtr.)

2

652

326

... More
Size : 100 mm dia DI dual plate check valve

4

38388

9597

... More
P & F Fluorscent tube rod in existing fixtures as required, minimum 5 STAR rating

-

-

-

... More
28 Watts

2

280

140

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

104

7176

69

... More
Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) PVC casing capping & it's accessories, 18 SWG 175 mm x 100 mm x 60 mm M.S. box with earth terminal, 6 A switch, 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.

-

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings (IS 1239 mark) including trenching and refilling etc. (external work): Medium Duty Pipes 50 mm dia B class

10

3890

389

... More
Random Rubble stone masonary for superstructure above plinth level one storey height above 30 Cm. thick walls in :

-

-

-

... More
Size : 200 mm dia DI Resilient Seated Sluice Valve

2

64592

32296

-

-

-

... More
Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4, with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge

20

29960

1498

... More
Size : 100 mm dia DI Resilient Seated Sluice Valve

2

25476

12738

... More
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :

-

-

-

... More
1 X 28 Watts with EB

2

1822

911

... More
Providin fixing and commissionig of Led light of 100 watt

4

49876

12469

... More
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.

83

4980

60

... More
Supply , Instlation, testing and commissoning of Electromagnetic Bulk Flow Meters as per various pumps house requirment and as per specification

-

-

-

... More
4 core 10 mm2

100

9000

90

... More
On board

2

182

91

... More
Size :250mm

1

8364

8364

... More
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : With cement mortar 1 :4 ( 1 cement : 4 Fine sand)

100

17000

170

... More
Size : 125 mm dia DI Resilient Seated Sluice Valve

1

17511

17511

... More
Supply and Fixing of CI Foot Valve as per ISS and various pumps house requirement

-

-

-

... More
Providing and laying PVC insulated and PVC Sheathed calbe of 1.1 KV grade with aluminium conductor of IS 1554 categary -01 approved make of including excavation of 30 CM x75CM side trench as per IS 1255-15CM Thick under layer of sand II class brick covering ,reffling earth in the remaining poration makeing necessary connection including testing etc of required.

-

-

-

... More
(a) 4.00 Sq.mm 3 core flat / Round

2100

287700

137

... More
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:

-

-

-

... More
Size: 10.0 Sqm 4 Core

30

5190

173

... More
Providing and laying PVC insulated and PVC sheathed m cables of 1.1 KV grade with aluminum conductor of IS 1554 category-I and of approved make including excavation of 30 cm x 75 cm side trench as per IS-1255 15 cm thick under layer of sand II class brick covering, refilling earth in the remaining portion making necessary connection including testing etc. of required size (category-I) make as mentioned in specification. This includes all required Hardware material, termination end with suitable crimping lugs.

-

-

-

... More
Size : 80 mm dia DI dual plate check valve

4

31652

7913

... More
Long point (up to 10 mtr..)

2

830

415

... More
Cement Mortar 1:6 (1-Cement:6-Sand).

20

49160

2458

... More
Size : 250 mm dia DI Resilient Seated Sluice Valve

2

102164

51082

... More
Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish:

-

-

-

... More
Short point (up to 3 mtr.)

2

480

240

... More
Supply & instlating 100mm dia meter sealed diaphragm bourdon type pressure gauge glicerine field alongwith including all jointing material range 0-10 kg. As per specificatioin with seft cover

1

800

800

... More
Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering -All up to plinth level

-

-

-

... More
Providing Fixing of Flanged/ Plain ended MS specials Made from MS Sheet strips of relevent IS.specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes material , Labour, inside Laying , out side coating testing or commissioning along with pipeline as per tecnical specifiction and Direction of Engineering Incharge ( MS pipe specials upto 600 mm dia with minimum 5mm Thickness Sheet)

1010

120190

119

... More
Repair to brick masonary in cement sand mortar 1:6 with new brick.

50

12800

256

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

20

16100

805

... More
Short point (up to 3 mtr.)

2

388

194

... More
200 mm

1

119300

119300

... More
Colour washing of all shades to give an even shade including all scaffolding.New work (two or more coats) with a base coat of white washing with lime.

160

2000

12.5

... More
P & F box type fluorescent tube fitting fabricated from CRCA sheet and finished with powder coating / stove enamelled paint complete with accessories (Low Loss Copper Choke, starter, starter seat) / Electronic Choke with terminal block duly prewired with copper conductor including making connection, testing etc. as required. ( without tube)

-

-

-

... More
Size : 150mm

3

13662

4554

... More
Providing and laying PVC insulated and PVC Sheathed calbe of 1.1 KV grade with aluminium conductor of IS 1554 categary -01 approved make of including excavation of 30 CM x75CM side trench as per IS 1255-15CM Thick under layer of sand II class brick covering ,reffling earth in the remaining poration makeing necessary connection including testing etc of required.

-

-

-

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) PVC casing capping & it's accessories, round tiles, Moulded PVC Modular Box with , 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required.

-

-

-

... More
Providing,instlation,testing and commissioning of horizonatal spilt casing type centrifugal pump set with TEFC IP-55,415 volts squirel cage induction motor as per IS 325 with minium efficeincy 85% and speed not more than 1450RPM and pump manufacture and design as per IS: 6596 having following duty condition head with transportation,loading unloading and all prevailling taxes and suppled with base plate,foundation bolts,coupling etc on concrete foundation/RSJ with accurate levelling and proper alignment as per scope of works and techinal specification,This items include all the necessary civil works required to install the pump set inclusing removal of existing systems dismentalling of foundation .Test reports and performance curves for deliverirng ther required flow as designed head complete in all respect

30

374340

12478

... More
4 core 16 mm2

100

11000

110

... More
Size : 125mm

1

3477

3477

... More
Cement Mortar 1:4 (1-Cement:4-coarse sand).

20

86440

4322

... More
Size :200mm

2

12758

6379

... More
Providing and Fixing of cast iron specials (class-10) as per IS:5531-1988) specification as required.

200

12000

60

... More
Cement Mortar 1:6 (1-Cement:6-coarse sand).

30

108510

3617



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.