Public Health Engineering Department Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date30 Apr 2025
Closing Date12 Jun 2025
Tender Amount₹ 12,22,08,87,738 
Notes
Download

AI Insights

Work Experience Requirements
... View More
The bidder should have experience of works related to water supply schemes/projects during the last 7 years up to the date of submission of bids. The experience requirements include: - Execution and successful completion & commissioning of one of the following: - Three similar works each costing not less than 30% of the estimated cost of the bid. - Two similar works each costing not less than 40% of the estimated cost of the bid. - One similar work costing not less than 50% of the estimated cost of the bid. The estimated costs of the bid mentioned are: - 366.63 Cr. - 488.84 Cr. - 611.04 Cr. These costs correspond to the 30%, 40%, and 50% thresholds, respectively, implying that the bidder needs to have completed similar works with values such as: - Three works of at least 109.89 Cr. (30% of 366.63 Cr.), - Two works of at least 195.54 Cr. (40% of 488.84 Cr.), - One work of at least 305.52 Cr. (50% of 611.04 Cr.). The experience of project execution means an executed water supply scheme/project having at least 2 key components out of pipeline, pumping stations, RCC clear water reservoirs, and Over Head Service Reservoirs (OHSR).
Bid Capacity
... View More
The formula for Financial Capacity is: 1. [Net worth at the close of the proceeding financial year] less [ Net worth to be sponsored by bidder for the PPP projects undertaken by the bidders]. 2. In case where financial closure procedure is pending for any PPP package, Net worth to be sponsored by bidder will be considered as [the package cost] less [construction support by client/ authority]. The variables used in the formula are: - Net worth at the close of the proceeding financial year: This refers to the aggregate value of the paid-up share capital and all reserves created out of the profits and securities premium account, after deducting the aggregate value of the accumulated losses, deferred expenditure and miscellaneous expenditure not written off, as per the audited balance sheet. - Net worth to be sponsored by bidder for the PPP projects: This is the amount that the bidder needs to sponsor for the PPP projects undertaken by them. - Package cost: This refers to the total cost of the PPP package. - Construction support by client/ authority: This refers to the support provided by the client or authority for the construction of the project.

Costs

  • EMD

    ₹ 24,44,17,755
  • Document Cost

    ₹ 1,18,000
  • Tender Fee

    ₹ 2,500

Summary

Chambal Alwar Bharatpur Water Supply Project Package-iii Based On Hybrid Annuity Model (ham) Ace(p) Bharatpur Nit No. 06/2024-25

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1000 -4000 mm

5

787921

3939605

... More
toTO Ph Kankra*(kishangarh Bas)PH Kotkasim ENROUTEQ=172.16 lps H-7M, KW-30

2

417660

835320

... More
Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS

354

3333

1179882

... More
For Class-A loading

-

-

-

... More
200 mm dia

441345

1701

750727845

... More
PH KANHAWAS

300

5820

1746000

... More
Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
150 mm dia

6

136800

820800

... More
50 SQMM, 3 CORE

2100

426

894600

... More
Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0

-

-

-

... More
8 core, 2.5 sq. mm. armoured

9100

193

1756300

... More
125 mm dia NB( Thickness of pipe 4.8 mm & mass of tube 16.40 Kg/m)

1480

1603

2372440

... More
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3 & 4

-

-

-

... More
630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,

2

35376

70752

... More
200 mm dia RCC pipe

280

28900

8092000

... More
800 mm dia.

6

618656

3711936

... More
Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm

433

33500

14505500

... More
PH HUSEPUR

300

5820

1746000

... More
630/800 A Rating ,50 Ka

2

208919

417838

... More
Construction of RCC (Flat slab type) Rectangular partially underground Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase in side and out side. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.

-

-

-

... More
600 mm dia.

11

69331

762641

... More
80 mm dia

71

9137

648727

... More
300KL capacity

600000

22

13494000

... More
200 mm dia

38

37011

1406418

... More
PH AJARKA

300

5820

1746000

... More
1000 KL capacity

5000000

4

23600000

... More
toESR (O) SeedpurQ=22.22 lps H-67M, KW-30

2

417667

835334

... More
900 mm

16229

24381

395679249

... More
50 mm dia.

2352

426

1001952

... More
700 mm dia.

10

92761

927610

... More
Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm

46

89900

4135400

... More
Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed: All kinds of soil

134400

35

4704000

... More
M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).

122.51

3731

457094.14

... More
500 mm dia.

24

34191

820584

... More
Door Interlock

8

3384

27072

... More
400 mm dia

6

247397

1484382

... More
6 to 8 stage

52

15370

799240

... More
600 mm with Gear

7

263170

1842190

... More
450 mm

16397

7398

121305006

... More
800 mm dia RCC pipe

30

75300

2259000

... More
11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)

650

2094

1361100

... More
OD 323.9 mm dia and thickness 5.6 mm

10

5148

51480

... More
200 mm HW

55

22603

1243165

... More
Operation Counter

8

8354

66832

... More
180 mm dia

67958

1125

76452750

... More
150 mm dia

52

40162

2088424

... More
SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
300 mm dia (With Gear Operated)

16

52123

833968

... More
Upto 25mm dia

103

265

27295

... More
1000 mm dia.

10

183534

1835340

... More
Air valve chamber of size1.05m x1.4m x2.42m for air valve size of 150mm

14

58900

824600

... More
MANDHAN PH

300

5820

1746000

... More
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.0

-

-

-

... More
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m)Construction of inlet chamber, and valve chambers n) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
PH GOBRA

300

5820

1746000

... More
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works

5000

23

115000

... More
600 mm dia

6

368293

2209758

... More
75 mm dia

86895

186

16162470

... More
2000 A Rating ,50 kA

4

311624

1246496

... More
Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum

46

3098

142508

14

157854

2209956

... More
200 mm

110532

2554

282298728

... More
100KVA

24

261516

6276384

... More
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.

-

-

-

... More
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.

12240

5820

71236800

... More
100 mm dia.

1402

3666

5139732

... More
toESR (O) Shahjahanpur Q=29.39 lps H-44M, KW-30

2

285634

571268

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix

377

5678

2140606

... More
Up to 300 mm dia

2552

111

283272

... More
50 mm dia

2108

13499

28455892

... More
Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
95 SQMM, 3.5 CORE

800

784

627200

... More
2250 KL (Beelauthi)

2250000

4

10957500

... More
1750 Kl ( Peeplan)

1750000

5

9047500

... More
toESR (O) Nakachpur Q=19.97 lps H-72M, KW-30

2

417667

835334

... More
PH NITHAR

300

5820

1746000

... More
50/63 A rating

17

1419

24123

... More
5.5 KW (7.5 HP)

12

55225

662700

... More
toESR (P) Khohra KarmaliQ=20.75 lps H-87M, KW-37

2

417667

835334

5

475000

2375000

... More
toESR (O) KamalpuraQ=18.56 lps H-55M, KW-22

2

327316

654632

... More
150 mm dia.

974

5758

5608292

... More
300mm dia

12

788276

9459312

... More
From 3.3 KW to 7.5 KW DOL Starter Feeder with MCB,Main and Aux Contactor,O/L Relay,L/R Selector Switch,3 Indicating lamps,Start-Stop Push Button ,Control MCB (Size : 600 (W) x 400 (H) x 600 (D)

24

24083

577992

... More
Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost

-

-

-

... More
150 mm

9806

3249

31859694

... More
Class PN 1.6

-

-

-

... More
600 mm

19364

11563

223905932

... More
40 mm dia

280

13021

3645880

... More
Type VI ( 407.48 Sqm)

5

9863420

49317100

... More
80 mm thick.

231662.28

298

69035359.44

... More
PH Bhindoosi

300

5820

1746000

... More
50 KVAR

22

11057

243254

... More
160 KVA

56

326895

18306120

... More
Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in

-

-

-

... More
3 core 50/70/95 Sq.mm

448

4932

2209536

... More
toESR (O) CHOOHARPURQ=21.46 lps H-65M, KW-30

2

417667

835334

... More
1000 mm dia 14 mm thick casing pipe

150

135200

20280000

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.

-

-

-

... More
Making connection of G.I. distribution branch with G.I. main including all fitting.

-

-

-

... More
300 mm

73750

4221

311298750

... More
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity 99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
500 mm dia RCC pipe

400

44700

17880000

... More
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.

-

-

-

... More
Providing, Installation, Testing and Commissioning of Ultrasonic Flow Meter Insertion Type: Principle: Time of Flight / Type: Insertion / Protection : IP68 / Power Supply: 230 V AC / Output : 4-20 mA with HART / Accuracy: 2 - 3%

-

-

-

... More
Supply, installation, testing and commissioning of GSM /GPRS/ Cloud based data transmitter for Bulk Flowmeter (woltman Magnetic Pulse Output only ), Battery Powered -3VDC to12VDC , Model no- CT-DL-V1.0-100784, battery life 3-5 Years, Inbuild Memory fuction upto 2gb micro SD card supported to stroe the data in the absense of availabe mobile network, (1 no Data transmit in a day on cloud system), Encloser- ABS Protection-IP67/68, Operating tempreature -50-55 Deg. C. The VTC Inlet Flow Data shall be transmitt to the Respective MCC ROOM.

536

42000

22512000

... More
1600 KVA with % Impedance 6.25

4

3240357

12961428

... More
Red/yellow/Blue

2674

267

713958

... More
PH JORIYA

300

5820

1746000

... More
140 mm dia

171185

713

122054905

... More
toTO ESR JN-6ESR (EX) Bijorawas ENROUTEQ=15.83 lps H-117M, KW-37

2

492507

985014

... More
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
400 mm

26682

6269

167269458

... More
Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab. j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
600 mm dia

12

337993

4055916

... More
200mm dia

15

552018

8280270

2

361240

722480

... More
1626 mm dia/14.2 mm th

50

66099

3304950

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 102 No. DO 98 No. AI 22 No. AO 16 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (uto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 12 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot

8

1456362

11650896

... More
Bituminous courses

1289.4

416

536392.27

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils

2015

178

358670

... More
PH Maharajpura

300

5820

1746000

... More
100mm dia

4

368438

1473752

... More
Valve Chamber size 2.80X2.50X2.50 Valve size 1000 mm to 1200 mm

7

159610

1117270

... More
toESR (P) NeemliQ=50.6 lps H-98M, KW-110

2

1159730

2319460

... More
225 mm dia

809

1697

1372873

... More
Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.

-

-

-

... More
WBM Grading 1 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete.

-

-

-

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.

4966612.27

77

382429144.71

... More
Triple pole MCB (With B/C curve trippingCharacteristics), 6 A to 32 A rating

431

933

402123

... More
400 mm dia (With Gear Operated)

5

84260

421300

... More
100 mm dia

1077

11554

12443658

... More
1000 KL ( Husepur)

1000000

4

4980000

... More
PH SALEMPUR KHURD

300

5820

1746000

... More
Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminum, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC

193

7848

1514664

... More
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
500 mm with Gear

8

184884

1479072

... More
Hard rock(blasting prohibited) useful material 30%

257

551

141607

... More
Type V ( 381.5 Sqm)

10

8806160

88061600

... More
HDPE PE-100 PN-6

-

-

-

... More
toESR (O) HisamadaQ=20.73 lps H-106M, KW-45

2

574425

1148850

... More
Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.

-

-

-

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
400 mm dia

1

240346

240346

... More
PH KATARA

300

5820

1746000

... More
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.

-

-

-

... More
Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
Providing and laying Stranded/ Flexible Annealed Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (2 Pair * 0.75SQMM)

37500

118

4425000

... More
PH HARNAGAR

300

5820

1746000

... More
800 mm

1

695241

695241

... More
up to 6 KVAR

348

1858

646584

... More
toESR (O) HathauriQ=22.79 lps H-66M, KW-30

2

417667

835334

... More
toESR (E) JeendoliQ=24.22 lps H-59M, KW-30

2

327309

654618

... More
1200 mm dia.

1

203624

203624

... More
400 mm dia

6

165735

994410

... More
k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Providing, installation, testing and commissioning of Level Switch ( Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum

-

-

-

... More
toESR (O) RAMCHANDRAPURAQ=22.48 lps H-46M, KW-22

2

285634

571268

... More
Hard rock(blasting prohibited)

232836.18

782

182077894.73

... More
toTO ESR ESR (O) BijorawasESR (P) Untoli ENROUTEQ=18.44 lps H-130M, KW-55

2

672595

1345190

... More
400 mm dia

36

123339

4440204

... More
500 mm

134

14908

1997672

... More
Supply of dry manure including loading unloading,transportation & stacking at site

-

-

-

... More
800 mm dia (With Gear Operated)

6

334083

2004498

... More
Shunt Trip Release

8

2853

22824

... More
Gun-metal 50 mm nominal bore.

49

1464

71736

... More
800 mm dia.

18

119543

2151774

... More
400KL capacity

400000

19

7868000

... More
toTO ESR ESR (P) GunsarGLSR (E) Basni ENROUTEQ=19.33 lps H-115M, KW-45

2

574425

1148850

... More
200 mm dia

6

155060

930360

... More
350 mm with Gear

5

86838

434190

... More
Supply, installation, testing & Commissioning of Copper wound distribution Transformer of following rating and % Impedance, 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled losses as per IS 1180 part I 2014 (Fourth Revision) Level-1, with boltless core design including standard accessories like conservator with prismatic oil level gauge , silica gel breather, Bucholz relay, pressed steel radiator fins, Radiator Valve(above 800 Kva) Suitable size HT cable box, LT cable box with Busbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ), temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device, Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS :335-1953 , Epoxy primer and PU based paint as Top coat, Unidirectional rollers for rating upto 800 kva & bi- directionalabove 800 Kva rollers with locking arrangement etc. as required. The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including Temperature rise test in OEM's own lab shall be witnessed by Department engineer Physically. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)Following tests shall be carried out on each transformer at site by OEM enginer in presence of department authorised representative:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .

-

-

-

... More
150 SQMM, 3 CORE

150

1123

168450

... More
900 mm

1

780244

780244

... More
900 mm dia.

14

576157

8066198

... More
toESR (O) Lakhanpur Q=20.22 lps H-83M, KW-37

2

417667

835334

350

439

153650

... More
Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of Earth.

400

240

96000

... More
Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)} medium of following sizes at site of work.

-

-

-

... More
200 mm dia.

617

8564

5283988

... More
1000 A Rating ,50 kA

2

219447

438894

... More
All End Flanged

-

-

-

... More
Heavy Duty AL & CU Lugs, Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements.

29

50000

1450000

... More
50mm x 6mm G.I. ( Hot Dipped ) Strip

2800

416

1164800

... More
Carriage of Materials by mechanical transport including loading,unloading and stacking ::

-

-

-

... More
toESR (O) AkhaigarhQ=17.79 lps H-65M, KW-30

2

417660

835320

... More
Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
toESR (P) Gelpur Q=27.21 lps H-74M, KW-45

2

417667

835334

... More
Different varieties of climbers 900mm to 1500 mm

1000

144

144000

... More
Spreading of manure , good earth in required thickness (cost of manure and good earth to be separately )

1000

24

24000

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 15 M

-

-

-

... More
Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.

-

-

-

... More
Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Standard Size 600x800mm (75mm thick) for span 300 to 450mm

921.79

1583

1459200

... More
PH Giglana

300

5820

1746000

... More
160 mm dia

155894

897

139836918

... More
toESR (O) JalalpurQ=36.58 lps H-45M, KW-37

2

327309

654618

... More
Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.

8267.5

44

363770

... More
32 mm Dia.

452

761

343972

... More
1100 mm dia.

3

174040

522120.3

... More
180 x 180 x 91 mm

452

1535

693820

... More
Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.

448

8534

3823232

... More
EFM 450 mm

2

387167

774334

... More
800 mm dia.

6

118282

709692

... More
toTO Ph Hulmana Khurd*(Mandawar)Ph Ajarka*(Mandawar)Q=89.86 lps H-27M, KW-55

2

417667

835334

... More
OD 457 mm dia and thickness 6.3 mm

40

8200

328000

... More
250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,

76

20287

1541812

... More
Providing, Installation, Testing and Commissioning of Ultrasonic Level Transmitter : Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1%

-

-

-

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
200 mm dia

55

55019

3026045

... More
S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required.

-

-

-

... More
914 mm dia/8.0 mm th.

290

20932

6070280

... More
350mm dia

2

829368

1658736

... More
Outer dia 508 mm & thickness 5 mm

50

7263

363150

... More
Rates for RCC Partially Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC ZONE-2 & 3.

-

-

-

... More
Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Liquid Epoxy shall be NSF/WARS approved for drinking water and minimum thickness of lining shall be 406 microns.

51296.73

409

20980362.81

2

229712

459424

... More
Excavation work by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains not exceeding1.5 m in width or 10 sqm on plan including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting outthe excavated soil and disposal of surplus excavated soil asdirected with a lead in a 50 meter including stacking of useful material if available :

-

-

-

... More
500 mm

24423

8835

215777205

... More
700 mm dia (With Gear Operated)

3

234240

702720

... More
Horticulture Work

-

-

-

... More
toESR (O) Ajeet NagarQ=32.43 lps H-74M, KW-55

2

492515

985030

... More
OD 610 mm dia and thickness 8.8 mm

90

15279

1375110

... More
35 SQMM, 3 CORE

7500

326

2445000

... More
IPS/PH Majari Kalan

300

5820

1746000

... More
Mechanical Interlocking kit

52

7117

370084

... More
Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
toESR (O) BarauliQ=18.07 lps H-61M, KW-22

2

327316

654632

... More
PH HARSOLI

300

5820

1746000

... More
630 KVA with % Impedance 4.5

4

1966939

7867756

... More
toTO ESR ESR (O) Khohra PeepliESR (P) Boojaka ENROUTEQ=17.31 lps H-81M, KW-30

2

417660

835320

... More
300 mm

1690

5095

8610550

... More
250 mm dia

14

66241

927374

... More
Extensible 2 way RMU with 1 no. VCB & 1 No. Load Break Switch

112

392000

43904000

... More
Different varieties of shrubs 600mm to 900 mm

1000

160

160000

... More
EFM 500 mm

1

424286

424286

... More
Above 300mm and up to 600 mm diameter

4500

179

805500

... More
100 KL capacity

1800000

33

60084000

... More
2.2 KW (3.0 HP)

62

80307

4979034

... More
EFM 125 mm

189

126481

23904909

... More
Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto 100mm

827.5

29800

24659500

... More
Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase upto 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.

62

10009

620558

... More
PH SHRIYANI

300

5820

1746000

... More
700 KL (HUsaipuri)

700000

5

3654000

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m)

1125

4473

5032125

... More
Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.

452

8142

3680184

... More
Heavy Duty AL & CU Lugs, Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements.

27

35000

945000

... More
toTO ESR ESR (O) PurJN-16 ENROUTEQ=25.34 lps H-58M, KW-30

2

327309

654618

... More
10 KVAR

65

2334

151710

... More
Auxiliary + Trip alarm contact

104

1675

174200

... More
1100 mm dia.

3

1238640

3715920

... More
Type VII ( 692.72 Sqm)

1

13743840

13743840

... More
Ordinary rock

396689.81

365

144791780.65

... More
PH NIBHOR

300

5820

1746000

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.

-

-

-

... More
Providing, lowering, laying and jointing in trenches,  standard lengths  ISI marked Rigid PVC-O S/S Pipes (push on joints) as per IS-16647: 2017 (amended upto date) with EPDM Gasket seals on joints including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, laying of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
200 mm dia

1

59837

59837

... More
50 KL capacity

500000

39

19860000

... More
200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)

2925

2734

7996950

... More
800 KL (Manki)

800000

5

4128000

... More
PH Mundawar

300

5820

1746000

... More
PH KHOHRI KALAN

300

5820

1746000

... More
150 mm dia

949

19109

18134441

... More
350 mm

540

8826

4766040

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
300 mm dia

2

198850

397700

... More
toESR (O) BeejwaQ=14.77 lps H-77M, KW-22

2

327316

654632

... More
SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Folliwng items and accessories:- i Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. ii Lockable Mushroom head type push buuton with 2 NC Contact element. iii 2.5 Sqmm clipon type terminals as requried with 20% spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.

356

2000

712000

... More
Outer dia 323.9 mm & thickness 4.5 mm

880

4151

3652880

... More
Up to 300 mm Diameter

2500

158

395000

... More
110 mm dia

704692

874

615900808

... More
120 SQMM, 3.5 CORE

6950

969

6734550

... More
For Class-AA loading

-

-

-

... More
150 mm dia

226

139701

31572426

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Arches, arch ribs, domes, vaults, shells, folded plate, chimneys, shafts , roofs having slope more than 15º ,vertical and horizontal fins individually or forming box louvers, facias and eaves boards M20 grade Nominal Mix / Design Mix

16698.12

5561

92858217.52

... More
Provision for Dewatering

19

10000

190000

... More
toESR (O) Nangal TappaQ=16.1 lps H-77M, KW-30

2

417660

835320

... More
Providing and applying 100% Solids, Rigid, DTM Polyurethane lining to internal surface of M.S. Pipe as per AWWA C222 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Polyurethane Coating shall be NSF/WARS/SS-375 approved for drinking water and minimum thickness of lining shall be 500 microns.

62762.63

643

40356373.66

... More
450 mm dia

5

284669

1423345

... More
PH PEEPLANA

300

5820

1746000

... More
1422 mm dia/12.5 mm th

20

50883

1017660

... More
PH PALI

300

5820

1746000

... More
1250 KL (Naugaon)

1250000

6

7662500

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -

-

-

-

... More
200 mm dia

102485

1348

138149780

... More
toESR (O) VIJAYNAGARQ=15.53 lps H-76M, KW-30

2

417660

835320

... More
800 KL capacity

4000000

4

19760000

... More
Supplying and drawing PVC insulated & sheathed solid/ stranded copper conductor multi core control cable ISI marked (IS:1554) of 1.1 kV grade of approved make as per chapter E11,in existing surface or recessed conduit/ casing capping including making connections etc. as required.

-

-

-

... More
At Pump houses

1165412.8

57

66428529.6

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
400 mm dia.

6

30524

183144

... More
PH Fauladpur

300

5820

1746000

... More
Microswitch for Indication

8

2482

19856

22

119619

2631618

... More
1524 mm dia/14.2 mm th

150

61916

9287400

... More
250 mm dia

5

177836

889180

... More
600 mm dia.

5

385252

1926260

... More
150KL capacity

3150000

26

83191500

... More
2000 KL (Khori Kallan)

2000000

5

10160000

... More
450 mm with Gear

9

147665

1328985

... More
Type IV ( 212.9 Sqm)

28

5210970

145907160

... More
Sluice valve chamber of size1.26m x1.185m x1.82m for pipe size-from 200-to-300mm

266

43500

11571000

... More
500 mm dia (With Gear Operated)

6

126540

759240

... More
toESR (O) JHARKAIQ=21.5 lps H-60M, KW-30

2

285634

571268

... More
1750 Kl ( Mundawar)

1750000

5

9047500

... More
toTO ESR ESR (EX) Talwar ESR (O) Sherpur ENROUTEQ=12.02 lps H-145M, KW-37

2

492507

985014

... More
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.

-

-

-

... More
Kayasa PH

300

5820

1746000

... More
toTO ESR ESR (O) Gujarwas ESR (O) Jaguwas ENROUTEQ=15.67 lps H-63M, KW-22

2

327316

654632

... More
350 mm dia (With Gear Operated)

5

65006

325030

... More
250 mm dia.

6

15849

95094

... More
SITC of Ultrasonic Level Transmitter suitable for measuring water level in reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %, as per detailed Technical specification, scope of work and direction of Engineer in charge.

-

-

-

... More
200 mm dia

596

29396

17520016

... More
Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm

55

65300

3591500

... More
Surg Protuction

-

-

-

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
600 mm dia

23

243762

5606526

... More
450 mm dia

16

156591

2505456

... More
300 mm HW

6

45382

272292

... More
toESR (O) Kheri DevisinghQ=23.96 lps H-67M, KW-37

2

417667

835334

5

515000

2575000

... More
1250 KL (Gabra)

1250000

6

7662500

... More
Ordinary rock

1720.25

268

461027

... More
EFM 150 mm

207

139687

28915209

... More
Outer dia 406.4 mm & thickness 5 mm

200

5796

1159200

... More
1000 mm dia.

4

750935

3003740

... More
Sluice valve chamber of size1.39m x1.43m x2.185m for pipe size-from 350-to-450mm

13

52700

685100

... More
75 KL capacity-18 m staging

150000

32

4944900

... More
400 SQMM, 3.5 CORE

1991.44

2774

5524268

... More
HDPE PE-100 PN-6

-

-

-

... More
10 SQMM, 3 CORE

2200

183

402600

... More
PVC-O pipe Class 500 PN-16

-

-

-

... More
150 mm HW

234

13595

3181230

... More
250 mm dia

4

177684

710736

... More
Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete

-

-

-

... More
450 mm dia

5

214721

1073605

... More
Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as per Table 500-23, premixed with bituminous binder @ 14.60 kg/ 10sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required), including loading of material with F.E. loader, hot mixing of stone aggregate and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting smooth wheeled roller 8-10 tonne capacity and finishing to required level to achieve the desired density as per clause 511 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding cost of tack coat/ seal coat.

-

-

-

... More
EFM 250 mm

21

177439

3726219

... More
1016 mm dia/ 8.8 mm tk

80

25597

2047760

... More
450 mm dia

5

203807

1019035

... More
2032 mm dia/16.0 mm th

20

93155

1863100

... More
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix

464.5

5003

2323893.5

... More
Single Flange/ MJ Collar

-

-

-

... More
BARDOD PH

600

5820

3492000

... More
600 mm

80

19798

1583840

... More
Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer.

-

-

-

... More
Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67

368

23238

8551584

... More
2.2 KW (3.0 HP)

2

34070

68140

... More
toESR (O) AsleempurQ=18.41 lps H-57M, KW-22

2

327316

654632

... More
Construction of RCC pillar for following size of air valves including earthwork excavation, RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge.

-

-

-

... More
150 mm

10656

2384

25403904

... More
400 mm dia RCC pipe

30

34400

1032000

... More
PH PATHENA 1

300

5820

1746000

... More
toESR (O) Kakrali Q=20.76 lps H-75M, KW-30

2

417667

835334

... More
toTO ESR ESR (O) Mundiya KheraESR (O) Gadoj ENROUTEQ=24.51 lps H-154M, KW-75

2

858225

1716450

... More
toESR (O) Bagar MeoQ=16.89 lps H-69M, KW-30

2

417660

835320

... More
PH Dadarhera

300

5820

1746000

... More
25mm x 6mm G.I. ( Hot Dipped ) Strip

2000

201

402000

... More
Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

19113.28

4678

89411942.18

... More
Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of 98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document.

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work).

-

-

-

... More
800 mm dia.

24

444787

10674888

... More
PH SAMRAYA

300

5820

1746000

... More
12 to 14 stage

5

20115

100575

... More
Up to 300 mm Diameter

4500

151

679500

... More
1750 Kl ( Manjhi)

1750000

5

9047500

... More
Valve Chamber size 2.50X2.10 X2.10Valve size 800 mm to 900 mm

10

131870

1318700

... More
Spreaders for 400A, 4Pole MCCB

40

3179

127160

... More
Above 1.5 mtr and up to 3.0 mtr.

48600.12

20

972002.49

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. (2X5X90)

20640

121

2497440

... More
toESR (O) MAIQ=23.53 lps H-63M, KW-30

2

417667

835334

... More
Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating

228

1254

285912

... More
M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

220.25

3847

847301.75

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 62 No. DO 58 No. AI 14 No. AO 6 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot

34

1140082

38762788

... More
High Power LED Flood Light Minimum lumen output 10000 lm

224

4941

1106784

... More
Sluice valve chamber of size 1.13 m x0.85 m x1.325 m- for pipe size-up to 100 mm

63

36700

2312100

... More
400 mm with Gear

5

113457

567285

... More
150 mm dia RCC pipe

468

28500

13338000

... More
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6

-

-

-

... More
For Class-AA loading

-

-

-

... More
250KL capacity

1500000

22

34455000

... More
Add extra for trenches for every additional lift over item no 4.1

-

-

-

... More
C T Class 1, Ratio upto 150/5, Burden 5 VA

108

1244

134352

... More
11KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,Pre-cast covers ect.

12

250000

3000000

... More
Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

29858.93

757

22603210.01

... More
11.0 KW (15 HP)

52

83148

4323696

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
300 mm dia

3

194973

584919

... More
In Rock

-

-

-

... More
300 mm dia

2

76588

153176

... More
1400 mm dia.

1

1619280

1619280

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in-charge.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
toTO ESR ESR (O) Siwana ENROUTEQ=19.87 lps H-68M, KW-30

2

417667

835334

... More
Goat dungmanure.

400

1200

480000

... More
500 KL capacity

1500000

5

8160000

... More
KOTKASIM PH

300

5820

1746000

... More
150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)

4034

1933

7797722

... More
toESR (O) BUDHWARI KALANQ=36.51 lps H-46M, KW-37

2

285634

571268

... More
Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metr depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of OH tank and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.

56

16800

940800

... More
5500 KL ( Bardod)

5500000

3

21945000

... More
4 core, 1.5 sq. mm. armoured

13950

87

1213650

... More
813 mm dia/7.1 mm th.

220

16525

3635500

... More
Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia. ‘B’ class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance as required.

336

1961

658896

... More
toTO ESR ESR (O) BaghorGLSR(E) Ismailpur ENROUTEQ=21 lps H-74M, KW-30

2

417667

835334

... More
Gun-metal 25mm nominal bore.

103

529

54487

... More
toTO Ph Pehal*(Mandawar)Ph Jeendoli*(Mandawar)Q=78.3 lps H-52M, KW-90

2

858245

1716490

... More
IPS/PH THIKRIYA

300

5820

1746000

... More
250KL capacity

500000

21

10860000

... More
Providing and applying 3LPE (3 Layer Polyethylene) tape coating conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10 to external surface of M.S. Pipe comprising of a layer of fusion bonded epoxy (FBE), overlaid with PE adhesive with an outer layer of high density polyethylene including preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2. Minimum thickness of FBE shall be 250 microns including field joints coating at site complete as per technical specification and direction of Engineer-in-Charge. Minimum thickness of coating shall be 3.0 mm on weld seam as well as remaining surface.

64141.12

1227

78701153.16

... More
25 SQMM, 3 CORE

7450

250

1862500

... More
250 mm

2340

4011

9385740

... More
150 mm dia

226

21821

4931546

... More
toESR (O) BaiQ=32.23 lps H-75M, KW-55

2

492515

985030

... More
200 mm

6679

3037

20284123

... More
1000 mm dia 14 mm thick casing pipe

60

348800

20928000

... More
toESR (E) BACHHAMADIQ=25.09 lps H-48M, KW-30

2

285634

571268

... More
toPH NITHARQ=117.97 lps H-110M, KW-250

5

1906000

9530000

... More
For in-campus Valve Chambers

-

-

-

... More
700 KL capacity

1400000

5

7028000

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
toESR (O) NaghoriQ=21.5 lps H-66M, KW-30

2

242227

484454

... More
Type II ( 111.34 Sqm)

1

2765720

2765720

... More
Spreaders for 250A, 4 Pole MCCB

160

1580

252800

... More
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.

-

-

-

... More
150 mm dia.

226

11445

2586570

... More
Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm

459

40900

18773100

... More
EFM100 mm

129

113454

14635566

... More
3 core 4.0 Sq.mm

4354

189

822906

... More
Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.

4960.5

200

992100

... More
700 mm Dia 10 mm thick casing pipe .

50

33457

1672850

... More
1000 KL (Harsoli)

1000000

4

4980000

... More
250 KVA with Off -LTC (+5% to - 10% @ 2.5%)

8

438040

3504320

... More
Plunger Type Flow Control Valve

-

-

-

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.

-

-

-

... More
in rows 7.5 cm apart in either direction

4000

55

220000

... More
Outer dia 711 mm & thickness 6.3 mm

70

12822

897540

... More
Valve Chamber size 3.00X2.75X3.10 Valve size 1600 mm to 1800 mm

2

191950

383900

... More
Plain ended CI specials including tail piece, spigot end and socket end.

-

-

-

... More
PCC work - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

180

4320

777600

... More
80 mm dia

24

121297

2911128

... More
Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.

-

-

-

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) nterconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee

1175

6124

7195700

... More
EFM 80 mm

14

103636

1450904

... More
Providing and laying in position specified grade of cementconcrete for all RCC structural elements upto plinth levelincluding curing, compaction, finishing with rendering incement sand mortar 1:3 (1 cement: 3 coarse sand) and makinggood the joints and cost of plastizers( if required) excludingthe cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix

65789.24

4934

324604110.16

... More
For Grading II Material

900

1376

1238400

... More
500 mm Dia 8 mm thick casing pipe .

100

23569

2356900

... More
500 mm dia

1

299107

299107

... More
800 mm dia 12 mm thick casing pipe

50

100200

5010000

... More
50 KL capacity-18 m staging

50000

42

2105160

... More
Above 600 mm diameter

6000

235

1410000

... More
Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
800 mm

14486

19885

288054110

... More
Sluice valve chamber of size1.61m x1.75m x2.72m for pipe size-from 500-to-700mm

25

72600

1815000

... More
Discharge 161 to 180 LPS and head 20 to 30 M (Kishangarhbas)

2

858245

1716490

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
Different flowering plants 900mm to1500mm

1000

150

150000

... More
100 mm dia

62

23449

1453838

... More
Air valve chamber of size1m x1.1m x1.945m for air valve size of 100mm

62

45800

2839600

... More
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.

63325

72

4559400

... More
300 mm dia.

110

14024

1542640

... More
toESR (E) UNCH Q=24.82 lps H-61M, KW-30

2

417667

835334

... More
63 mm dia

8000

145

1160000

22

98135

2158970

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
1750 Kl ( Hasanpur Mafi)

1750000

5

9047500

... More
Construction of RCC platform for transfarmer near Pump house as per detail specification and GAD, Size 3.00 mtr. X 3.00 mtr. outer 1) Earth work 0.6o width and 0.60 mtr. Deep for 4 nos wall, 2) PCC in M-10 with 20 mm stone aggrigate, 3) Raft for wall- 0.45 mtr. width - 0.15 mtr. thick. 4) 0.15 Mtr. thick RCC wall upto 1.00 mtr. above from GL. 5) earth filling with compaction in side. 6) 0.15 mtr. thick PCC M-10 under floor and 7) 0.15 mtr. thick RCC M-20 flooring complet as per direction of EIC.

79

48661

3844219

... More
Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating

374

580

216920

... More
Above 1.5 mtr and up to 3.0 mtr.

13525.17

37

500431.47

... More
150mm x 50mm x 1.6mm

2575

692

1781900

... More
Provision for Cathodic protuction as per detail estimate

1

4453800

4453800

... More
Class PN 1.6, Manually Operated with Gear

-

-

-

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :

-

-

-

... More
Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).

-

-

-

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
200 mm dia

36

155351

5592636

... More
4.0 SQMM, 3 CORE

36605.15

126

4612249.03

... More
C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA

117

1613

188721

... More
Under voltage Release

8

4545

36360

... More
EFM 300 mm

7

219283

1534981

... More
C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA

279

1345

375255

... More
300 mm dia

9

62128

559152

... More
S & F of Star delta Starter with MCB,Main and Aux Contactor,O/L Relay, L/R Selector Switch,3 Indicating lamps,Start-Stop Push Button ,ontrol MCB with panel with all accessories with following rating : 18.5KW

104

13570

1411280

... More
Outer dia of pipe 457 mm and thickness 5 mm

100

6527

652700

... More
200 mm

864

4250

3672000

... More
80 mm dia

11

17236

189596

... More
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
OD 273 mm dia and thickness 5.0 mm

10

3870

38700

... More
50 KL capacity Dhakpuri (Tijara)

50000

8

430500

... More
100 mm HW

318

8649

2750382

... More
toTO ESR ESR (P) NibhorESR (O) Guwana ENROUTEQ=36.42 lps H-84M, KW-75

2

574432

1148864

68

109242

7428456

... More
Extended Rotary Handle

104

2781

289224

... More
3 core 95.0 Sq.mm

4050

1319

5341950

... More
SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.

-

-

-

... More
125 mm dia.

119

4792

570248

... More
PH HAMEEDPUR

300

5820

1746000

... More
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
toESR (E) KAWAI-2Q=34.55 lps H-79M, KW-55

2

492515

985030

... More
toESR (O) MILAKPUR TURKQ=39.3 lps H-67M, KW-55

2

492515

985030

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level.

104371.3

157

16386294.1

... More
250 mm

534

5733

3061422

... More
S & F of Star delta Starter with MCB,Main and Aux Contactor,O/L Relay, L/R Selector Switch,3 Indicating lamps,Start-Stop Push Button ,ontrol MCB with panel with all accessories with following rating : 11KW

58

12136

703888

... More
125 mm dia

193892

573

111100116

... More
Provision for surg protuction as per detail estimate

1

25000000

25000000

... More
400 Amp , 35 kA, adjustable O/L & adjustable S/C setting

22

24442

537724

... More
Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm. Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx.

-

-

-

... More
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :

-

-

-

... More
3.7 KW (5.0 HP)

6

43760

262560

... More
Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm

187

52300

9780100

... More
EFM 200 mm

80

141972

11357760

... More
7.5 KW (10 HP)

14

67514

945196

... More
toESR (E) SAINDOLIQ=29.07 lps H-54M, KW-37

2

417667

835334

... More
Ordinary or hard rock.

714

61

43554

... More
MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet)

5086.42

134

681580.14

... More
100 mm

100

1179

117900

... More
Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.

547

1243

679921

1219

11616

14159904

... More
450 mm dia.

15

28756

431340

... More
300mm x 50mm x 1.6mm

700

1079

755300

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 20 M

-

-

-

... More
11KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,Pre-cast covers ect.

15

200000

3000000

... More
Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
PH BAJHERA KALAN

300

5820

1746000

... More
toTO ESR ESR (O) MohammadpurESR (EX) Jainpurbas ENROUTEQ=24.17 lps H-91M, KW-45

2

285634

571268

... More
450mm dia

1

1208964

1208964

... More
Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.

-

-

-

... More
Providing, lowering, laying, aligning, fixing in position CI D/F short body pattern type butterfly valves having body, disc and end cover in graded cast iron generally conforming to (IS13095/1991amended up to date), synthetic rubber faced ring secured on disc by retaining ring with SS steel screw stub shaft of SS riding in Teflon bearing including C.C. foundation/ structural steel support, material, labour, testing along with pipe line and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work

-

-

-

... More
70 SQMM, 3.5 CORE

2200

625

1375000

... More
toESR (O) KatariyapuraQ=25.02 lps H-69M, KW-37

2

417667

835334

... More
GARHI PH

300

5820

1746000

... More
125 mm dia

226

17774

4016924

... More
Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coil including excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling, excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work.Excluding cost of pipe line. Note: Trenchless laying shall be done only for laying of pipe line (rising main) and road crossing of distribution pipe line under CC/BT roads.

4701.73

289

1358799.97

... More
800mm dia

1

4183868

4183868

... More
250 mm dia RCC pipe

240

29700

7128000

... More
toTO ESR JN-12 ENROUTEQ=14.81 lps H-144M, KW-45

2

574425

1148850

... More
VTC - Construction of village lavel transfer chamber and meter room, work including require earth work PCC 1:4:8 under floor & for foundation, walls of chmber constrected by RCC M-20, with Fiber reinforced Ferro cement drain cover (light duty). Construction of brick masonary meter room above GL, 23 cm thick Brick masonary walls over stone masonary foundation coverd by RCC roof, CC flooring, MS sheet door with lackin arrangments .

536

88110

47226960

... More
Air valve pillar for air valves size of 150mm dia

9

30400

273600

... More
MANKI PH

300

5820

1746000

... More
75 KL capacity

900000

31

27990000

... More
100 mm dia NB (Thickness of pipe 4.5 mm & mass of tube 12.50 Kg/m)

1021

1286

1313006

... More
400 KL capacity

1200000

6

7812000

... More
toESR (EX) JHIWANAQ=34.6 lps H-63M, KW-45

2

492515

985030

... More
1829 mm dia/14.2 mm th

100

74424

7442400

... More
Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank as per specification

-

-

-

... More
Vermi compost

400

250

100000

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil

1901872.33

200

380374466

... More
600 mm dia.

21

48304

1014384

... More
Above 300mm and up to 600 mm diameter

6500

168

1092000

... More
Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.

575.93

340

195814.5

... More
250 mm dia.

194

11729

2275426

... More
900 KL (Khanpur Mewan)

900000

5

4554000

... More
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- ( External Work ) Medium Duty Pipes

-

-

-

... More
700 mm

150

25541

3831150

... More
900 mm dia.

2

154893

309786

... More
toPh Nasopur*(ramgarh)Q=36.62 lps H-34M, KW-30

2

285634

571268

... More
200KL capacity

3800000

22

86336000

... More
200 mm

14

74101

1037414

... More
Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100 mm

20266

1670

33844220

... More
toTO ESR ESR (P) JHIRYANAESR (P) KIRWARI ENROUTEQ=21.34 lps H-61M, KW-30

2

417667

835334

... More
Manually Operated CI Sluice valve of Class PN-1.0

-

-

-

... More
With Bitumen VG-grade 30

6000

119

714000

... More
32mm x6mm G.I. ( Hot Dipped ) Strip

2000

251

502000

... More
125 A rating

24

6476

155424

... More
SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.

-

-

-

... More
300 mm Dia 8 mm thick casing pipe.

155

18353

2844715

... More
Provision for Construction of Half Set Chokidar Hut

52

892811

46426172

... More
300 mm dia RCC pipe

30

30600

918000

... More
Khilora PH

300

5820

1746000

... More
Nasopur PH

300

5820

1746000

... More
toGLSR (O) AgyaraQ=21.91 lps H-54M, KW-30

2

327309

654618

... More
18.5 KW (25.0 HP)

56

143629

8043224

... More
toESR (O) NangliQ=29.55 lps H-51M, KW-30

2

327309

654618

... More
250mm dia

14

645671

9039394

... More
700 mm

6410

15544

99637040

... More
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: 1:6 C. Mortar

552

4263

2353176

... More
toESR (O) BantkhaniQ=17.33 lps H-85M, KW-30

2

417660

835320

... More
3500 KL (Thikariya)

3500000

4

15400000

... More
7 Mtr., Poles with Octagonal Cross Section

452

13481

6093412

... More
toPH MaharajpuraQ=157.57 lps H-61M, KW-200

2

1556866

3113732

... More
600 mm Dia 10 mm thick casing pipe .

100

30211

3021100

... More
PH BHUSAWAR-I

300

5820

1746000

... More
1 KVA

57

52592

2997744

... More
Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.

-

-

-

... More
900 KL capacity

4500000

4

21645000

... More
1750KL Capacity

1750000

6

12110000

... More
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4

-

-

-

... More
Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Centrifugal Monoblock Pump set (Single Stage)

-

-

-

... More
toTO ESR ESR (O) PATALIYA ESR (O) JHARKA ENROUTEQ=36.9 lps H-57M, KW-45

2

417667

835334

... More
Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.

6000

33

202200

... More
300 mm dia.

2

19614

39228

... More
Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485

112

6429

720048

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3 core 50/70/95 Sq.mm

224

7217

1616608

... More
Supply & Planting of shady plants ( Neem. Peepal, Goolar, Jamun, Imli or other specified) along road side including the following activities:- (i) Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. (ii) Supply of plant at site of two years of age & height more than 1.50 Mtr. (iii) Supply of dry manure(Farm yard manure organic) (iv) Supply of Insecticides. (v) Digging of pits size 60x60x60 cms. Including removal of stones. Manuring application of insecticides & watering at least 1.5 Liter per plant after planting (vi) Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter above ground and 0.20 meterr below ground. Bottom two courses laid dry and top three couses in cement mortar 1:6 ( 1 Cement : 6 Sand) and the intermediate courseses being in dry honey comb masonry. As per design complete. (vii) Watering to plants (viii) Maintance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc & application of insecticiedes etc. & security. If the plant die during maintence contractor has to rplace same heingh plant at his own cost.

2000

1886

3772000

... More
80 mm HW

2

6301

12602

... More
200 KVA

10

411888

4118880

... More
450 mm dia (With Gear Operated)

3

101611

304833

... More
PH MILKIPURA

300

5820

1746000

... More
GSB Providing, laying, spreading and compacting of granular sub-base by providing close graded material (Table 400-1), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion.

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required

-

-

-

... More
150 mm

125523

2082

261338886

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100 mm dia

62

124743

7734066

... More
160 mm dia

428450

1480

634106000

... More
Electrolytic grade Aluminium bus bar 6010 grade

4112.5

556

2286550

... More
PH Khanpur Mewan

600

5820

3492000

... More
Providing, laying and jointing RCC NP4 jacking pipe (with steel pushing collar) with suitable leak proof joints (with using `12mm MDF sheets etc.) with compliance for maintaining slope as per design by trenchless method adopting Micro tunnelling method or any suitable mechanical technology below ground at all depth under running traffic condition including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipment’s for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects, including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructing thrust bed at designed level as directed by the Engineer, necessary de-watering and providing concrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackles required, construction of temporary works as per requirement complete in all respect (all depths) with all lead and lifts, as per specification and the direction of the Engineer. Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.

-

-

-

... More
Outer dia of pipe 813 mm and thickness 8 mm

7815

18599

145351185

... More
500 mm dia

18

196252

3532536

... More
PH Bheeteda

300

5820

1746000

... More
Providing, lowering, laying and jointing in trenches,  standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.

-

-

-

... More
PH PALPUR

300

5820

1746000

... More
700 mm dia

10

333978

3339780

... More
toTO ESR ESR (O) DhisESR (O) Ajmeripur ENROUTEQ=10.22 lps H-97M, KW-22

2

327316

654632

500

901

450500

... More
70SQMM, 3 CORE

1100

558

613800

... More
10 AMP

470

372

174840

... More
15 KVAR

18

3152

56736

... More
Outer dia of pipe 711 mm and thickness 8 mm

19748

16242

320747016

... More
80 mm dia

24

9458

226992

... More
Construction of Pump house of brick/ stone masonry of required size suitable for installation of maximum 4 no. Monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. Boosing PH in Distribution Dhakpuri (Tijara)

9

20251

182259

... More
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

19113.28

6162

117776055.52

... More
toESR (O) Chawandi KalanQ=26.69 lps H-39M, KW-22

2

242227

484454

... More
toESR (EX) Jairoli Q=23.1 lps H-50M, KW-30

2

285634

571268

... More
100 mm dia

62

12598

781076

... More
Providing and fixing of reinforced Ferro-Cement drain covers designed for 'A' class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc

-

-

-

... More
toTO ESR Neemrana (u)J-23 ENROUTEQ=213.48 lps H-68M, KW-315

5

1855336

9276680

... More
1000 KL (Sodawas)

1000000

4

4980000

... More
Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating .

506.01

1227

620874.27

... More
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix ( Encashing of Pipe in River/ thrust block))

675

5185

3499875

... More
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m)Construction of inlet chamber, and valve chambers n) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.

-

-

-

... More
100 mm dia.

62

8339

517018

... More
50mm x 6mm copper strip

2800

4223

11824400

... More
M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).

81

5018

406458

... More
2000 mm dia

4

3837600

15350400

... More
Air valve pillar for air valves size of 80mm dia

1228

19800

24314400

... More
300 SQMM, 3.5 CORE

4000

2165

8660000

... More
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)

63964.22

126

8059491.72

... More
SITC of Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, Instantaneous , earth fault (LSIG) with separate LED indication for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, provision of ZSI, Communication, Power metering module, Thermal memory , trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10000 upto 2000 A rating and 5,000 for 2500 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
PH BEELAUTH

300

5820

1746000

... More
Outer dia 610 mm & thickness 5.8 mm

130

10121

1315730

... More
toESR (EX) SarsainaQ=27.91 lps H-51M, KW-30

2

327309

654618

... More
Sluice valve chamber of size1.26m x1.185m x1.82m for pipe size-from 200-to-300mm

48

41700

2001600

... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
250 mm

97394

3307

322081958

... More
PH Karoli

300

5820

1746000

... More
100mm x 50mm x 1.6mm

2800

567

1587600

... More
Repair of Bituminous Road using GSB 15 cm thick, WBM 15 cm thick in two layers , 20 mm thick bitumin carpet and sand seal coat Complete as per specification and scope of work. ( based on PWD Raj 2022 BSR)

85430.9

610

52112849

... More
PH HASANPUR MAFI IPS+CPS

300

5820

1746000

... More
OD 1118 mm dia and thickness 8.8 mm

14886

28189

419621454

... More
SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect . The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 18 M

-

-

-

... More
Single arm overhang

452

1936

875072

... More
Measuring range 0.0 to 6.0 mtr

826

119106

98381556

... More
Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded/fused in single piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.

-

-

-

... More
Class PN 1.0

-

-

-

... More
Construction of RCC (Rectangular Type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -

-

-

-

... More
SITC of HT metering cubical panel as approved By DISCOMs fabricated out of 18 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX 6mm having provision for Following: (i)Provision for fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections, etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

56

32852

1839712

... More
Air valve chamber of size1.325m x1.7m x2.875m for air valve size of 200mm

41

81100

3325100

... More
315 KVA with Off -LTC (+5% to - 10% @ 2.5%)

6

635040

3810240

... More
PH Rambas

300

5820

1746000

... More
Uprooting weeds from the lawn plots and trenched area after 10 to 15 days of its flooding with including disposal of uprooted vegetation

8000

240

1920000

... More
1400 mm dia 20mm thick casing pipe

100

481600

48160000

... More
toTO ESR ESR (O) Antpura ENROUTEQ=11.84 lps H-132M, KW-30

2

417660

835320

... More
Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
toTO ESR ESR (P) BINOLIYAESR (O) Bhamoowas ENROUTEQ=21.83 lps H-59M, KW-30

2

327309

654618

744

680

505920

... More
300 mm

1124

7314

8220936

... More
1500KL Capacity

4500000

7

32940000

... More
Type III ( 150.6 Sqm)

13

3361960

43705480

... More
300 mm dia

85

74691

6348735

... More
400mm dia

3

1147092

3441276

... More
PH MANJHI

300

5820

1746000

... More
Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’

112

104718

11728416

... More
25 mm dia nominal bore Class-B

185

278

51430

... More
1500 KL (Chaparada)

1500000

5

8160000

... More
600 mm dia 12 mm thick casing pipe

150

66900

10035000

... More
Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum

193

3098

597914

... More
In all type of soils

-

-

-

... More
Supply, Testing & Commissioning of Horizontal Split casing centrifugal pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity, horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 3.3 K V ± 10%, rated speed 1450 RPM along with fabricated MS base frame, coupling, coupling guard, foundation bolts etc. as per relevant IS. M.O.C.: Impeller & Wearing Rings: CF8M, Casing: Cast Steel WCB , Shaft: SS 410, Shaft Sleeve: SS 410, Mechanical Seal (above 30 kW), Base Frame: MS.

-

-

-

... More
Air valve chamber of size0.9m x1m x1.695m for air valve size-from 50 mm-to-80mm

2165

39600

85734000

... More
Breaker Control Switch (TNC)

8

1322

10576

... More
Rigid for lengths from 3 - 10 Mtr.

57

61139

3484923

... More
Valve Chamber size 3.00X2.50 X2.80Valve size 1300 mm to 1500 mm

1

172160

172160

... More
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
PH Gujarwas

300

5820

1746000

... More
Add extra for trenches for every additional lift over item no 4.3

-

-

-

... More
80 mm dia

14

3149

44086

... More
1219 mm dia/10 mm th

10

34916

349160

... More
PH Pehal

300

5820

1746000

... More
toESR (O) ChhapurQ=24.39 lps H-57M, KW-30

2

327309

654618

... More
Providing & Fixing of Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
toESR (O) KHATNAWALIQ=25.64 lps H-69M, KW-37

2

417667

835334

... More
100 mm

176167

1464

257908488

... More
PH Jeendoli

300

5820

1746000

... More
24 CORE, 1.0 sq. mm.

11960.19

377

4508991.44

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.

-

-

-

... More
toTO ESR ESR (P) RampurESR (O) Baghana ENROUTEQ=20.5 lps H-58M, KW-30

2

327309

654618

... More
Manually Operated Resilient Seated Sluice Valves of Class PN 1.6

-

-

-

... More
4 CORE, 1.0 sq. mm.

37500

139

5212500

... More
1250 KL (Karoli)

1250000

6

7666250

... More
1000 KL (Rambas)

1000000

4

4980000

... More
Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -

-

-

-

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
Spreaders for 630A, 4 Pole MCCB

8

3513

28104

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

2

207482

414964

... More
450 mm

10

12686

126860

... More
350 mm dia.

22

18247

401434

... More
.Farm yard manure(organic)

400

720

288000

... More
Above 600 mm diameter

8500

219

1861500

... More
Providing and laying in position cement concrete includingcuring, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.

-

-

-

... More
Air valve pillar for air valves size of 200mm dia

52

36500

1898000

... More
Construction of RCC (Flat slab type) Rectangular Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase in side and out side. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.

-

-

-

... More
toTO ESR ESR (P) DhamookarESR (O) Padasala ENROUTEQ=31.22 lps H-43M, KW-30

2

327309

654618

... More
25 KVAR

17

3858

65586

... More
PH Sodawas

300

5820

1746000

... More
240 SQMM, 3 CORE

700

1776

1243200

... More
100 mm

4892

2259

11051028

... More
400 mm dia.

30

24715

741450

... More
PH HUSAIPUR

300

5820

1746000

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:

50000

81

4050000

... More
Building Rubbish Stone metal (Grit and ballast etc.) up to 1 KM

125000

80

10000000

... More
200KL capacity

600000

21

12996000

... More
1000 mm

7629

29327

223735683

... More
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20 mm th

4800

190

912000

... More
toESR (O) MahmadpuraQ=16.2 lps H-62M, KW-22

2

327316

654632

... More
400 mm Dia 8 mm thick casing pipe .

100

20972

2097200

... More
250 mm HW

23

35722

821606

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
90 mm dia

128120

264

33823680

... More
250 mm dia

162

48781

7902522

... More
8 core, 1.5 sq. mm. armoured

14050

136

1910800

... More
CHAPRADA PH

800

5820

4656000

24

133380

3201120

... More
toTO Ph Ichchhaka*(kishangarh Bas)Khairtal (u) ENROUTEQ=165.82 lps H-25M, KW-90

2

858245

1716490

... More
toESR (O) Samantpura Q=21.25 lps H-75M, KW-37

2

417667

835334

... More
toTO ESR ESR (O) FatiyabadESR (O) Gurgachka ENROUTEQ=18.68 lps H-61M, KW-22

2

327316

654632

... More
11KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,Pre-cast covers ect.

29

300000

8700000

... More
250 Amp , 25 kA, adjustable O/L & adjustable S/C setting,

4

17917

71668

... More
700 mm dia

1

451694

451694

... More
OD 219.1 mm dia and Thickness 4.5 mm

70

2789

195230

... More
Class PN 1.6, Motorised Operated

-

-

-

... More
600 mm dia 12 mm thick casing pipe

50

248800

12440000

... More
Providing and applying Spray applied, 100% Solids (Solvent free) Two Component PU ( Polyurethane) coating as per AWWA C222 Standard on external surface of M.S. Pipe including preparation of pipe outer surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2 including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Minimum dry film thickness of coating shall be 1000 micron

52588.96

852

44805798.11

... More
350 mm

27905

5140

143431700

4

183890

735560

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 30 No. DO 26 No. AI 6 No. AO 2 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot

9

647272

5825448

... More
Hard rock (requiring blasting) useful material 30%

270.75

444

120213

... More
150KL capacity

450000

24

11241000

... More
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.

3307

1780

5886460

... More
Manually Operated Butterfly Valve PN-1.0

-

-

-

... More
PH Hulmana Khurd

300

5820

1746000

... More
Granular courses

4386.35

296

1298359.6

... More
350 mm dia

39

93544

3648216

... More
100 KL capacity

200000

31

6348000

... More
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.

36209.71

64

2317421.44

... More
80 mm dia.

24

7259

174216

... More
Auxiliary Contact 4 NO + 4 NC

8

5642

45136

... More
toESR (P) Bhamraka Q=23.34 lps H-47M, KW-22

2

285634

571268

... More
1250 KL (Bhindoosi)

1250000

6

7662500

... More
PH BHOPUR

300

5820

1746000

... More
toESR (O) Sukhman HeriQ=26.35 lps H-49M, KW-30

2

285634

571268

... More
Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMB's. Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. (Protective coating/ lining if done that will be paid extra) Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.

-

-

-

... More
Class PN 1.6

-

-

-

... More
700 KL (Garhi)

700000

5

3654000

... More
Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)

3795

383

1453485

... More
200 mm dia.

38

12954

492252

... More
250 mm dia

4

55783

223132

... More
LED Street Light fixture with Minimum lumen output 8700 lm

452

5993

2708836

... More
toESR (P) KairQ=22.21 lps H-61M, KW-30

2

417667

835334

... More
Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm

18

32300

581400

... More
600 KL capacity

1800000

5

9252000

... More
Electromagnetic Flow Meter : Liner: Polyurethane or Hard Rubber /Electrode MOC: SS316L or CS /Housing : Die Cast Aluminium orCS / Power Supply: 90-230 V AC / Output: 4-20mA with HART /Sensor Cable : 10 mt / Flow Tube or Sensor housing protectionIP68 / Process Flange : SS316 / Display : 3 1/2 LCD Display /Cable Connection : 1/2"NPT /Accuracy : 0.5%

-

-

-

... More
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Removing & Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)

-

-

-

... More
0 - 5 Mtr.

57

74741

4260237

... More
toESR (O) DARBARPURQ=28.76 lps H-58M, KW-37

2

327309

654618

... More
Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
ICHCHHAKA PUMP HOUSE

300

5820

1746000

... More
Two or more coats on new work

5000

69

345000

... More
SITC of Intelligent Manageable Ethernet Switches providing 24 x 10/100/1000 Fast Ethernet ports- and 2 dual purpose uplink (provision for Copper / Fibre Giga connectivity) with LAN based Software. The LAN based S/W supports enhanced integrated security, including Network Admission Control (NAC), advanced quality of service (QoS), availability and scalable management to enable new converged applications

57

24776

1412232

... More
In all type of soils

-

-

-

... More
125 mm dia

121

17087

2067527

... More
Non luminous type

708

168

118944

... More
toESR (P) TharaQ=22.94 lps H-58M, KW-30

2

327309

654618

... More
Providing and fixing ISI mark (IS 9763: 2000 or amended up to date) PTMT bib cock 15 mm nominal bore, minimum weight 92 gms and length 100 mm as per technical specification, approved make and direction of Engineer in charge.

3307

196

648172

... More
800 KL (Katra)

800000

5

4128000

... More
600 mm dia (With Gear Operated)

4

171852

687408

... More
toESR (E) RONEEJA Q=36.73 lps H-62M, KW-45

2

492515

985030

... More
toESR (O) CHAWANDI KHURDQ=30.12 lps H-82M, KW-55

2

574432

1148864

... More
NAUGAWAN PH

400

5820

2328000

... More
EFM 400 mm

8

275303

2202424

... More
Crusher broken - Grade-III (53-22.4mm)

900

1915

1723500

... More
16 SQMM, 3 CORE

10400

198

2059200

... More
PH KANKRA

300

5820

1746000

... More
1400 mm dia 20mm thick casing pipe

150

210000

31500000

... More
toTO ESR ESR (O) Bheeteda ESR (O) Dawani ENROUTEQ=23.38 lps H-87M, KW-45

2

417667

835334

... More
110 mm dia

82528

442

36477376

... More
400 mm

112

10729

1201648

... More
EFM 600 mm

14

520970

7293580

... More
Quad-band GPRS/IOT/VPN/GSM/CLOUD 3G/4G/5G modem with Ethernet bridge/router/ serial server (RS232/485) interface.

57

60000

3420000

... More
250 KW Discharge 339 LPS , head 45 mtr. ( IPS Kishangarhbas to Neemrana line)

5

3428750

17143750

... More
400 KVA with Off -LTC (+5% to - 10% @ 2.5%)

2

763331

1526662

... More
125 mm HW

10

11173

111730

... More
1250KL Capacity

5000000

4

22700000

... More
15.0 KW (20.0 HP)

52

108825

5658900

... More
toESR (O) Nagla KhushaliramQ=25.93 lps H-77M, KW-45

2

417667

835334

... More
Class PN 1.0, Motorised Operated

-

-

-

... More
Columns, pillars, posts and struts etc.

2687.56

375

1007835



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.