Mohanlal Sukhadia University Tender

... More
The MLSU has issued a formal invitation for competitive bids for the Mohanlal Sukhadia University project, for Maintenance Of Toilet On Urgent Work Based On Daily Basic Need At Mds Hostel M.l.s University, Udaipur in Udaipur, Rajasthan, with an estimated contract value of Rs. 13,60,000. The bid opening date for this tender is 24-05-2025 and the last date for bid submission is 29-05-2025. Interested bidders for Mohanlal Sukhadia University tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Mohanlal Sukhadia University - MLSU Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date24 May 2025
Closing Date29 May 2025
Tender Amount₹ 13,60,000 
Notes
Download

Costs

  • EMD

    ₹ 27,200
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Carriage of earth including loading,unloading etc Earth, Sand, Lime, Morrum manure or sludge lead for 5 km

75

125

-

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils

10

178

-

... More
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

2

3302

-

... More
Random rubble dry stone Kharanja under floor.

5

932

-

... More
P/L cement concrete for foundation in M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

3

4320

-

... More
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to code IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).

25

748

-

... More
Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :- (i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. (ii) Applying Epoxy primer on the exposed steel bars. (iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush. (iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day. (v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete. (vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect.

95

1568

-

... More
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).

5

2838

-

... More
Brick masonry in superstructure in c.m.1:6

2

4990

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS. 2645 over the RCC slab including cleaning the surface before treatment. (b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cement mortar 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:4 (1 cement :4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300x300xmm square (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm.

150

473

-

... More
Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25 mm thick

50

211

-

... More
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :35 mm thick .Decorative teak veneer both side

20

2505

-

... More
P & F Indian type white glazed vitreous china 1 st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm.

12

3080

-

... More
Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor. Double Syphonic European W.C. with mounted W.V.C. flushing cistern of 10 litre capacity complete with all necessary internal fittings with Hydraulic seat cover.

4

17839

-

... More
P & F grating of approved quality/make C.P. brass with frame (heavy) and superior quality size 125mm dia.

50

97

-

... More
P&F Toilet paper holder with rod of approved quality/make C.P. brass heavy & superior quality.

4

602

-

... More
Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge Bib Cock with long thread 15 mm nominal size

10

823

-

... More
(-do-) Long body Bib Cock 15 mm nominal size

20

1084

-

... More
P/F 15mm dia connection pipe of approved quality/make PVC pipe with C.P. brass nuts upto length 450mm.

15

101

-

... More
--do-- 600mm.

20

116

-

... More
P/F Inlet connection (Angle valves) superior quality, of approved make, for Wash basin, Gyser etc C.P. Inlet connection 15mm Brass (IS:8931 marked)

15

501

-

... More
P/F rigid PVC pipe (IS:4985 mark) class II (4 Kg./Cm2) approved quality/make incl. jointing the pipe with solvent cement rubber ring and lubricant 110 mm dia.

150

282

-

... More
Providing Laying & jointing glazed S.W. pipes grade `A` (IS;651 marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1, excavation & refilling of earth in all types of soil upto 1.2m depth, S.W. fittings, including testing of joints etc, complete. 230mm dia

100

639

-

... More
Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe) 100mm dia S.W. pipe

100

217

-

... More
P/F rigid PVC pipe fittings (IS:4985 mark) of approved quality/make incl. jointing the pipe with solvent cement rubber ring and lubricant Reducer 110x75 mm110mm

10

97

-

... More
---do--- Plain Tee 110mm

10

187

-

... More
---do--- Door Tee 110mm

15

213

-

... More
---do--- Bend 87.5, 110mm dia.

20

161

-

... More
(---do---) coupler (Socket) 110mm

20

108

-

... More
--do-- Multi floor trap 110mm dia.

20

266

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 20 mm nominal size

100

289

-

... More
(--do--)25mm nominal size

100

376

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).25mm nominal size

100

262

-

... More
(--do--)50mm nominal size

100

757

-

... More
Providing & fixing PVC storage tank (IS: 12701 marked indicating the BIS license No. ) of approved make with cover, 25mm dia. 1 mtr. long G.I. over flow pipe and 25 cm. long washout pipe with plug and socket including making connections etc. complete of approved design,1000 litres capacity.

4

7841

-

... More
Construction of Chamber in all types of soil 300mm thick masonry in C.M. 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick inside plaster in C.M. 1:6 finished with floating neat cement 50mm thick M-15 grade C.C. flooring earth work etc. complete as per design incl. disposal of surplus earth within a lead of 50 mtr. Inside size 600 x 450mm depth upto 0.5 M Cement cover with frame.

12

3299

-

... More
Construction of Manhole in all types of soil inner size 1.5x1.2 M with 450mm thick masonry in C.M. 1:6, 10 cm thick cement concrete 1:5:10 in foundation 20mm thick inside plaster in C.M. 1:6 finished with floating neat cement 50mm thick M-15 grade C.C. flooring making channels 80mm thick stone slab covering with 40mm thick stone M-15 grade C.C. flooring, Ferro cement cover with frame of 450mm dia earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. Lead as per desing depth upto 1.5 M.

4

20016

-

... More
Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 300 Cm. dia outside & 300 Cm. depth .

4

24135

-

... More
Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site.

100

286

-

... More
Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M- 15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.

4

59860

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.