MBM University Tender
... More
The MBM University has issued a formal invitation for competitive bids for Under Ground Cabling For Improvement Of Electric Supply System In South Campus Of Mbm University, Jodhpur. in Jodhpur, Rajasthan, with an estimated contract value of Rs. 15,00,000. The bid opening date for this tender is 13-12-2024 and the last date for bid submission is 08-01-2025. Interested bidders for MBM University tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 30,000Document Cost
₹ 1,180Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MBMUJ_437196_1Bid Award Id
ViewTender No
MBMU/EAC/2024-25/2104 Dated 11.12.2024 (EAC/2024-25/38-41)Tender Authority
MBM University ViewPurchaser Address
-Website
http://eproc.rajasthan.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Plate Earthing as per IS:3043 with copper Earth plate of purity 95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe, including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
8
15144
121152
... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS: 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase KWH Meter
3530
1
3530
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I/IS:7098 PI of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6%, round/flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware/PVC pipe/open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 120.0 Sq.mm 3.5 core
160
904
144640
... More
SITC of 3/4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings, conforming to IS/IEC 60947 P-2:2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR, shunt trip, earth fault trip, door interlock, pad lock & rotary handle, including making connections etc. as required.OEM shall have submit NABL/CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection. 630 Amp, 50 kA
2
34513
69026
... More
Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/15-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet, degree of protection IP-31, front openable bus bar made out of Copper suitable for 100 amp. Capacity, bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer In charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.900 mm long, 4 strip
4
8518
34072
... More
Providing & Fixing of ISO certified company made off load change over switch four pole/two pole, 230/415 V, side handle operated conforming to IS:13947 P-III in sheet steel enclosure complete with connections with lugs, testing etc. as required in the following rating: All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. 400 A four pole
21870
1
21870
... More
Supplying and making end termination with heavy aluminium lugs (Pin / ring type) confirming to IS 8309-1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure "A" attached with this BSR. 120.0 sq.mm
40
26
1040
... More
SITC of 3/4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings, conforming to IS/IEC 60947 P-2:2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR, shunt trip, earth fault trip, door interlock, pad lock & rotary handle, including making connections etc. as required.OEM shall have submit NABL/CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 4 pole MCCB With Thermal Magnetic release. 250 Amp, 35 kA, adjustable O/L & adjustable S/C setting
6
19792
118752
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I/IS:7098 PI of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6%, round/flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware/PVC pipe/open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 95.0 Sq.mm 3.5 core
300
765
229500
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I/IS:7098 PI of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6%, round/flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware/PVC pipe/open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 70.0 Sq.mm 3.5 core
248
567
140616
... More
Supplying and making end termination with heavy aluminium lugs (Pin / ring type) confirming to IS 8309-1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure "A" attached with this BSR. 95.0 ssq.mm
80
19
1520
... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS: 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase Ammeter with Inbuilt Selector Switch
1689
1
1689
... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS: 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase Voltmeter with Inbuilt Selector Switch
1689
1
1689
... More
Supplying and making end termination with heavy aluminium lugs (Pin / ring type) confirming to IS 8309-1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure "A" attached with this BSR. 185.0 sq.mm
40
44
1760
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I/IS:7098 PI of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6%, round/flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware/PVC pipe/open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 50.0 Sq.mm 3.5 core
240
457
109680
... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS: 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Three phase KWH Meter Dual Source
3858
1
3858
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I/IS:7098 PI of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6%, round/flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware/PVC pipe/open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 185.0 Sq.mm 3.5 core
300
1415
424500
... More
Supplying and making end termination with heavy aluminium lugs (Pin / ring type) confirming to IS 8309-1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure "A" attached with this BSR. 50.0 Sq. mm
60
12
720
... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS: 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR. Frequency Meter
1172
1
1172
... More
Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/15-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet, degree of protection IP-31, front openable bus bar made out of Copper suitable for 200 amp. Capacity, bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 900 mm long, 4 strip-
11246
3
33738
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements