Central Electronics Engineering Research Institute Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 78,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CSIR_227245_1Tender No
14/486/2024-CETender Authority
Central Electronics Engineering Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes
-
-
-
... More
Cement mortar 1:4 (1 cement : 4 coarse sand)
2
-
-
... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
-
-
-
... More
Cement mortar 1:4 (1 cement : 4 coarse sand)
5
-
-
... More
Providing and fixing aluminium body Cam Action Slide Channel Overhead hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment and 90 degree stop arrangement, of approved quality and make with necessary accessories and screws etc. complete.
8
-
-
... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
... More
Size 250x10 mm
10
-
-
... More
Size 100x10 mm
40
-
-
... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete
-
-
-
... More
Size 125 mm
40
-
-
... More
Providing and fixing bright SS finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of strainless steel 304 lever handles of approved quality and make with necessary screws etc. complete.
8
-
-
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
790
-
-
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
-
-
-
... More
Hot finished welded type tubes
180
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
-
-
-
... More
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
1020
-
-
... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
-
-
-
... More
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
380
-
-
... More
12 mm cement plaster of mix
-
-
-
... More
1:4 (1 cement: 4 coarse sand)
20
-
-
... More
15 mm cement plaster on rough side of single or half brick wall of mix:
-
-
-
... More
1:4 (1 cement: 4 coarse sand)
45
-
-
... More
Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.
-
-
-
... More
Ordinary cement finish using ordinary cement
10
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
... More
Two or more coats on new work
85
-
-
... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required and including water thinnable priming coat with cement primer, to achieve even shade & colour and scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
-
-
-
... More
Two or more coats
850
-
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade :
-
-
-
... More
Two or more coat applied @ 1.67 ltr/ 10 sqm over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat to achieve even shade & colour and scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete on existing cement paint surface/rough cast plastered surface
1150
-
-
... More
Providing and fixing bright finished hooks and eyes in aluminium , ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade and approved quality and make with necessary screws etc. complete
-
-
-
... More
Size 150 mm
40
-
-
... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within CEERI campus lead as per direction of Engineer - in - charge.
-
-
-
... More
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
5
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within CEERI campus lead and repair and finsh the jambs in proper way:
-
-
-
... More
Of area 3 sq. metres and below
11
-
-
... More
Of area beyond 3 sq. metres
3
-
-
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within CEERI campus as per direction of Engineer-In-Charge.
55
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
-
-
-
... More
For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
410
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing strainless steel hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
535
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
-
-
-
... More
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
40
-
-
... More
Providing and Fixing 0.50 mm thick PVDF (Poly Vinylidene fluouride) both side of aluminium thickness 3.00 mm overall thickness 4.00 mm on walls,in doors & ceiling with proper required haging system and having fire rating of 120 minutes and fixing with silicon tape/ adhessive material as required ,in opening shutters and fixed sections including cutting PVDF sheet as per required at site, preparing smooth surface and making holes/making good as required cutting hoisting and fixing aluminium members etc. complete as directed by Engineer-In-Charge
5
-
-
... More
Providing and applying one coat of cement based ready made wall putty (Birla care/ J.K. White/ or equivalent) including preparing the surface smooth by san papering etc as per directions of the Engineer-in-charge. Consumption of the putty shall be not less than 5 Kg per 10 Sqm. Preperation and application of the putty shall be strictly as per the manufacturers guidelines and as per the directions of the Engineer-in-Charge. The putty shall be applied only after cleaning the surface thoroughly. Required curing shall be done before application of both the coats shall also be sand papered with Amery paper no. 320 No. to make the surface smooth and even suitable for any kind of wall painting. The rate includes all operations and all the material and necessary scaffolding etc. Complete as per direction of Engineer-In-Charge.
850
-
-
... More
Providing and fixing homogeneous Polyvinyl chloride sheet / tile in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhesives of approved quality and manufacturer like Dunlop S-758, Fevicol SR 998 or equivalent including welding of joints if required and rolling with light wooden roller weighing about 5 kg., all complete as directed by Engineer-in-Charge, in approved colour and shade including removal of old pvc flooring if required & preparing the smooth surface etc. as per direction of Engineer - in - charge.
380
-
-
... More
Repairs of reveals and jambs of doors and windows with cement mortar 1:3 (1 cement : 3 fine sand) including chiseling the damaged area and disposal of mulba in low laying area in CEERI Campus as per direction of Engineer-In-Charge.
65
-
-
... More
Repairs of cracks in walls by chiseling the cracked area upto 300 mm width as directed by the Engineer-in-Charge and filling with mortar in cement mortar 1:3 (1 Cement : 3 fine sand) before placing fibre glass mesh 150 mm wide of approved quality including disposal of mulba in low laying area in CEERI Campus etc as per direction of Engineer-In-Charge.
70
-
-
... More
Providing and fixing in position of 6 mm thick Tamper Proof, Water Proof clear Embossed Polycarbonate Sheets roof light sheets multi layers in specified locations and at all heights with necessary xylon coated self tapping / self drilling screws with EPDM washers at every ribs, etc., complete to match the profile of Aluminium zinc alloy coated high tensile steel roof sheets, as per instructions of Engineer-in- charge. The rate includes cost of poly carbonate sheets ,self tapping / self drilling screws with EPDM washer,silicone sealant at every ribs, and labour charges, all scaffolding charges, tools and plants and all other incidental charges etc. complete directions of Engineer-in-charge.
25
-
-
... More
PART 'B' ELECTRICAL WORK:- POINT WIRING Rewiring for light/fan/exhaust fan point with 1.5 sq. mm FR PVC insulated flexible copper conductor 1.1 KV grade and 1.5 sq .mm FR PVC insulated flexible earth copper conductor 1.1KV grade IS: 694 only of approved make (Group-1) in existing surface/recessed conduit pipe including dismantling of existing wiring, switchboard of any size with accessories/fittings etc. as required.
-
-
-
... More
Group C
10
-
-
... More
Labour charges of dismantling the ms conduit with wire safely, after dismantling cutting the wall on same place and recessed the same dismantled conduit with re laying the wire in this conduit making connection, finishing the wall etc as required
210
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
... More
Group C
25
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base, cover & blanking plate for modular switches in recess etc. as required. etc as required.
-
-
-
... More
1 or 2 Module (75mmX75mm)
38
-
-
... More
6 Module (200mmX75mm)
1
-
-
... More
8 Module (125mmX125mm)
3
-
-
... More
12 Module (200mmX150mm)
2
-
-
... More
Supplying & Fixing of 3Pin, 5Amp. Ceiling rose on juction box with provinding round phinolic sheet, including making connections etc. as required.
20
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.
-
-
-
... More
5/6 A switch
32
-
-
... More
3 pin 5/6 A socket outlet
4
-
-
... More
Telephone socket outlet RJ 11
4
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,after removing recessed existing board, disconnection making connections and testing etc. as required.
25
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100
-
-
... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
70
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
120
-
-
... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
180
-
-
... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
30
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
-
-
-
... More
3 x 2.5 sq. mm
30
-
-
... More
3 x 4 sq. mm
30
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
-
-
-
... More
2 x 1.5 sq. mm
20
-
-
... More
3 x 1.5 sq. mm
100
-
-
... More
4 x 1.5 sq. mm
50
-
-
... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
... More
2 Pair
110
-
-
... More
Supplying & Fixing of following sizes of steel conduit along with heavy duty accessories, junction box etc. in surface / recesse including painting in case of surface conduit, or cutting the wall, repair and making good the same as required.
-
-
-
... More
20 mm
110
-
-
... More
25 mm
50
-
-
... More
32 mm
25
-
-
... More
Supplying and drawing of 23 AWG UTP Data Cable (CAT 6) gigaspeed LAN Cable in the existing surface/ recessed Steel/ under floor trunking as required.
-
-
-
... More
1 run of cable
120
-
-
... More
P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts Simplex Faceplate with RJ-45, information outlet with shutter with colour coding on existing modular plate, including making connections testing etc. as required
8
-
-
... More
Supplying and fixing 6 amp 'C' Curve mini modular DP MCB on the existing modular plate including connections but excluding modular plate etc. as required.
24
-
-
... More
Supply of following sizes of BLDC energy saver ( 5 star rated) ceiling fan without regulator complete with double ball bearing, motor, blades, down rod, canopy, etc. complete as required.
-
-
-
... More
Size 1400 mm.
2
-
-
... More
Installation, testing and commissioning of ceiling fan, including wiring with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. complete as required.
2
-
-
... More
Supplying of recessed mounted 36 Watt full glow, slim energy efficient, Green Square 2'x2' LED lighting luminaires Type- RC380B LED42S-6500 G6 L60W60 PSU OD, Philips or equivalent make complete with hanging arrengment all accessories, metallic CRCA powder coated housing etc. complete as required.
40
-
-
... More
Installation, testing and commissioning of above LED tube light fittings complete with all accessories on surface of wall/ ceiling or suspended from ceiling including providing hanging arrengment , transperent/suitable connection wire/ 1.5Sq.mm FR PVC copper conductor etc. as required.
40
-
-
... More
Plate Earthing as per IS: 3043 with copper earth plate 600 x 600 x 3 mm thick by embodying 4 mtr below the ground lavel with alternate layers of salt and charcoal (95 kg. each) with 20 mm dia G.I. B class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete and testing of earth resistance as required.
3
-
-
... More
P/F 25mm x 5mm copper strip in 40mm dia G.I. Pipe from earth electrode. including connection with brass nut bolt spring washer excavation and refilling as rqd.
25
-
-
... More
Providing and fixing 25 mm X 5 mm copper strip on surface/wall with providing insulating support or with clamp for connections etc. as required.
45
-
-
... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
220
-
-
... More
Supply of XLPE insulated PVC sheathed 1.1 kv. Grade copper and Al. conductor armoured Cable IS: 7098 Part-1 of approved make.
-
-
-
... More
3.5 X 300 Sqmm Al. Cable
110
-
-
... More
4 X 16 Sqmm. Copper cable
40
-
-
... More
4 X 50 Sqmm Copper Cable
30
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on wall/ roof/ duct/ shaft including fixing by means of screws & rag bolts, suitable size MS U clamps complete as per specifications, repairing works etc as reqd. of following sizes of cables.
-
-
-
... More
upto 35 Sqmm.(clamped with 1mm thick saddle)
38
-
-
... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
30
-
-
... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
110
-
-
... More
Supply& making one end termination with heavy duty single compression brass gland SIBG type, aluminium/ copper lugs duly crimped with crimping tool, PVC tape etc. for following size of XLPE insulated & PVC sheathed aluminium/ copper cable of 1.1 KV grade as required.
-
-
-
... More
3½ X 300 Sqmm. Al Cable
2
-
-
... More
4 X 16 Sqmm. Copper cable
6
-
-
... More
4 X 50 Sqmm Al/Cu. Cable
2
-
-
... More
Supplying & fixing Following way, 415 volts, "C" curve, MCB suitable for inductive load of folloing pole with suitable size MCB box encloser complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Four Pole 63 amp with encloser
1
-
-
... More
Four Pole 32 amp with encloser
2
-
-
... More
P & F Recessed/ surface mounting vertical type heavy duty Double door type TPN-6 way sheet steel phosphatised powder painted Distribution Board with loose wire box incomer 1No. MCCB 4P-125A, 25KA and 15 Nos. SP AC MCB-32A 10KA ( 'C' breaking characteristic) and 1 No. TP 63 amp MCB for outgoing circuits, 125 Amp busbar, neutral link, earth bar & din rail etc conforming to IS; 13032, IS; 8623, BS; 5486 of approved make including making all the incoming/ outgoing connections, internal DB terminations with copper lugs, testing etc. as required.
1
-
-
... More
P & F Recessed/ surface mounting vertical type heavy duty Double door type TPN-6 way sheet steel phosphatised powder painted Distribution Board with loose wire box incomer 1No. MCCB 4P-125A, 25KA and 12 Nos. SP AC MCB-32A 10KA ( 'C' breaking characteristic) and 2 Nos. TP AC MCB-32A 10KA ( 'C' breaking characteristic) for outgoing circuits, 125 Amp busbar, neutral link, earth bar & din rail etc conforming to IS; 13032, IS; 8623, BS; 5486 of approved make including making all the incoming/ outgoing connections, internal DB terminations with copper lugs, testing etc. as required.
1
-
-
... More
Supplying & fixing 25 amps rating, 240 volts, "C" curve, MCB suitable for inductive load of folloing pole with suitable size MCB box encloser complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Double Pole with encloser
14
-
-
... More
Supplying and fixing recessed mounted heavy duty double door ,4 Way three pole and neutral, MCB distribution board, 415 volts on surface / recess, complete with loose wire box, tinned copper bus bar,neutral links, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted, making internal DB terminations with copper lugs including all the existing incoming/ outgoing connections, earthing, testing, repair & making good the wall with matching colour distemper/ white wash etc. as required.(But without MCB/RCCB/Isolator)
1
-
-
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
63 Amp
1
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single Pole (10-32)
12
-
-
... More
Supply of free standing floor mounted dust and vermin proof, compartmentalised 1400 X 1600 X 400 mm cubical panel made out of CRCA sheet, required hardware, duly painted by powder coating with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate, 100x50x6mm M.S. base channel, hinged door with locking arrangement for equipment/ switchgear/ busbar chamber/ cable alley . Thickness of sheet shall not be less than 2.0mm of any compartment. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls compartments having bolted type doors with detachable extension type structure. S/F of following accessories and their inter connections with lugs, terminating all the outgoing and incoming supply terminals in cable alley fixed on SMC/DMC type insulators (as per requirement) with suitable size copper strip with heat shrinkable PVC sleeves/ wire, suitable size earth copper strip through out run at the bottom of the panel testing etc as required.Area of board should not less than 6.88 Sqmtr.(as per line diagram).INCOMER - a) 1No- quick make and quick break 4 Pole current limiting MCCB 320 Amp., 36KA adjustable O/L & adjustable S/C setting with Rotary handle Operating Mechanism, thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter changeability including making connections with lugs, spreaders etc. as required for incoming supply. BUSBARS.- b) 1Set-TPN copper bus bars of minimum 320 Amp capacity with heat shrinkable coloured sleeves including DMC / SMC bus bar supports at required intervals complete for cross section, size supports and their spacing etc. c) 1Set- 96mm square flush pattern digital type voltmeter (0-500V) with builtin selector switch & 2Amp. back up MCBs. d) 1Set- 96mm square flush pattern digital type Ammeter (0- 200Amp) with builtin selector switch & one set of 3 Nos. CT's of Ratio 300 /5A for each set, class - I accuracy and 15VA burden. e) 3Nos. Phase indication LED lamps with 2Amp back up MCBs. f) 1set TP&N suitable size Terminals to receive XLPE aluminium / copper cable of 1.1KV grade for incoming ckt.
-
-
-
... More
OUTGOING a) 3 No- quick make and quick break current limiting 4P MCCB 125Amp., 30KA adjustable O/L & fixed S/C setting with Rotary handle Operating Mechanism, thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter hangeability including making connections with lugs, spreaders etc. as required. b) 3 No- quick make and quick break current limiting 4P MCCB 160Amp., 30KA adjustable O/L & fixed S/C setting with Rotary handle Operating Mechanism, thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter hangeability including making connections with lugs, spreaders etc. as required. c) 1 No- quick make and quick break current limiting 4P MCCB 250 Amp., 30KA adjustable O/L & fixed S/C setting with Rotary handle Operating Mechanism, thermal Magnetic Release and conforming to IS:13947-2/ IEC 60947-2 with front face and centralized adjustable, line load inter changeability including making connections with lugs, spreaders etc. as required.e) 7 sets suitable size TP&N Terminals to receive XLPE aluminium / copper cable of 1.1KV grade for outgoing ckts.
1
-
-
... More
P & F surface mounting heavy duty G frame panel board TPN- 6way sheet steel phosphatised powder painted pre-wired MCCB type Distribution Panel Board 250 amp, enclosures Conforming to IS:8623, IEC:61439, out going 4P MCCBs with incomer 1No. 4P MCCB-250A, 25KA and 2 Nos. FP MCCB-125A, 16KA, 2 Nos. FP MCCB-63 amp and 2Nos. FP MCCB 100 amp for outgoing circuits, Cable Alley set for 6Way, DB Panel of I/C 250A, neutral link, earth bar complete with all accessories of approved make including making all the incoming/ outgoing connections, internal DB terminations with copper lugs, testing etc. as required.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%