The ADA has issued a formal invitation for competitive bids for the Ajmer Development Authority project, for Remaining Work Of Fouth Floor At New Collectrate Building, Ajmer. in Ajmer, Rajasthan, with an estimated contract value of Rs. 30,08,000. The bid opening date for this tender is 16-10-2026 and the last date for bid submission is 27-10-2026. Interested bidders for Ajmer Development Authority tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Ajmer Development Authority - ADA Tender - Rajasthan Tender

Opening Date16 Oct 2026
Closing Date27 Oct 2026
Tender Amount₹ 30,08,000 
Notes
Download

Costs

  • EMD

    ₹ 60,160
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 500

Description

Remaining Work Of Fouth Floor At New Collectrate Building, Ajmer.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Supply & fixing of square Faceplate for Flush/ Surface Mount Information Outlets Single/Dual or Quad Aperture with dust cover, material should be High-impact, flame retardant, thermoplastic, UL listed material, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge.

-

-

-

... More
Dual Aperture

230

97

22310

... More
Supply, Installation, Testing and Commissioning of Rack mounted 19" 1U, 24 Port loaded, CRS chassis, powder coated, sheet steel, High-impact, flame retardant, thermoplastic, UL Listed, Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required. All as per pre approved by Engineer in charge.

-

-

-

... More
Modular Patch Panel Loaded with Cat -6 1/0

3

7128

21384

... More
Supply, Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest amendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IECС 60603-7-51, EN 60603-7, IEEE 802.0an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.0af / IEEE 802.0at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP).

-

-

-

... More
Cat 6, U/UTP (Unscreened/Un-shielded Twisted Pair) Patch Cord

-

-

-

230

204

46920

... More
Supply, Installation, OTDR/OLTS Testing & Fusion Splicing of Fiber OM2 Multimode Pigtail (50/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single SC/LC/SN/CS type connector in acc., as per latest amendments of TIA/EIA 569 Standard Specification as per requirements complete in all respect.

12

1099

13188

... More
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OM2 multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/ screwable adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, grommets, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement. All as per pre approved by Engineer in charge.

-

-

-

... More
Multi Mode LIU 24 Ports

10

12621

126210

... More
Supply & Installation of IP-20 & IK-08, Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, Vertical Mounting Rail 1.6 MM with 'U' Marking, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware, 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastener etc as required.

-

-

-

... More
12 U Rack with Width 600 mm & Depth 400 mm + 100 mm

4

14263

57052

... More
Supplying, installation, Testing and commissioning of following capacity 24 port Non POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AС Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN:

10

90151

901510

... More
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. (For Each SM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class

-

-

-

... More
1G SFP Single Mode/Multi Mode

5

3562

17810

... More
Supply and Installation of unshielded/360-degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, according. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11, RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM, Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per preapproved by Engineer in charge.

-

-

-

... More
Cat 6, Un-shielded Information Outlet

460

287

132020

... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.

-

-

-

... More
On board

900

310

279000

... More
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required.

-

-

-

1200

32

38400

... More
Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.

-

-

-

... More
2 x 2.5 sq. mm. + 1x1.5sqmm

1213

90

109170

... More
Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required.

-

-

-

... More
1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )

30

1748

52440

... More
Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required.

-

-

-

... More
450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute

21

6177

129717

... More
Supply , Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB).

-

-

-

... More
Cooling capacity 5000-5300 Watt, ISEER not less then 4.6

2

46701

93402

... More
SITC of following capacity BIS certified 1Phase Input, 1Phase Output advance DSP controlled IGBT based rectifier Online UPS with Inbuilt Isolation Transformer having 0.99 Input power factor & 0.8 Output factor, Input voltage & frequency range of 180-300V on full load/ 110-300V on 50% load & 50 Hz +/- 5% and output voltage & frequency of 230V+/-1% & 50 +/- 0.1 Hz. Overall efficiency of upto 92% (without Transformer Loss), Overloading of 105 - 110% 30 mins, 111 - 130% 5 mins,131 - 150% 10 sec, THDv of < 3% for Linear & < 5% for Non linear load.UPS should have LED Panel with LCD display showing load level, Battery Voltage Level, Input & Output Voltage, Input & Output Frequency. UPS should have protection from Input High / Low;Over Load;Short Circuit; Over Temperature and give audible alarms on Battery Mode;Low Battery;Fault;Over Load & Bypass Mode. SMF Batteries of 12V VRLA for 30 mins with MS Rack and necessary cable for UPS to Batteries Installation. UPS should have valid Certification like Type III environmental declarations from third party renowned agency complying to ISO 14025, CE, ROHS,BIS,EN 62040-1, EN 62040-2, IEC 62040-3 Etc. as required.

-

-

-

... More
5KVA UPS with 4992 VAH Battery

2

218293

436586.12

... More
Supply and Installation of unshielded/360 degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/ 500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per pre approved by Engineer in charge.

-

-

-

... More
Cat 6, Un-sheilded Information Outlet

4

287

1148

... More
SITC of following diagonal size professional Display, 4k Resolution, Brightness(Typ.) 440 nit and above , Contrast Ratio-2000:1 and above, Viewing Angle(H/V)-178/178, Response Time(G-to-G) 8ms, Input: RGB- Analog D-SUB, Video- HDMI 2.0 (2), HDCP- HDCP 2.2, Audio- Stereo mini Jack, USB- Only F/W upgrade, Outputs: RGB- DP1.2(Loop- out), Audio- Stereo mini Jack, External Control- RS232C(in/out), RJ45, External Sensor Detachable type(IR Ambient). Operation Hour 24/7. mounting bracket etc. as required.

-

-

-

1

146708

146708



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.