Airports Authority Of India Tender
... More
The AAI has issued a formal invitation for competitive bids for the Airports Authority Of India project, for Construction Of Additional Floors On Existing Radar Building. Subhead Sitc Including Aicmc in Bikaner, Rajasthan, with an estimated contract value of Rs. 69,43,879. The bid opening date for this tender is 20-05-2025 and the last date for bid submission is 12-06-2025. Interested bidders for Airports Authority Of India tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 1,45,031Document Cost
₹ 1,180Tender Fee
Refer Documents
Summary
Construction Of Additional Floors On Existing Radar Building. Subhead Sitc Including Aicmc
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_AAI_234581_1Tender No
AAI/Bikaner/E-E/VRV/VRF/2025Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Minimum 1.5 Tr HI-Wall Unit
18
100
-
... More
Minimum 2.0 Tr HI-Wall Unit
19
53
-
... More
Supply of Y/T Joints/ Headers/Refnets
20
10
-
... More
Installation, testing and commissioning of VRV/ VRF modular type air-conditioning ODU as per Item No. 1, complete with all accessories & sub assemblies fittings etc. including providing and fixing of suitable size MS Stand and top up of refrigerant gas at site, making electrical connections, jointing / connection of refrigerant pipes etc. complete for proper functioning of units complete as required and as per direction of EIC.
1
11
-
... More
Installation, Testing & Commissioning of VRV/VRF based HI-Wall type Indoor units complete with all accessories including insulation, pipe connections, electrical connection and SITC of suitable capacity Automatic Condensation Drain Pump with all accessories etc. complete for proper functioning of units as required.
-
-
-
... More
1.0 Tr HI-Wall Unit
7
10
-
... More
1.5 Tr HI-Wall Unit
18
22
-
... More
2.0 Tr HI-Wall Unit
19
-
-
... More
Refrigerant Copper Piping:
Supply, installation, testing of inter connecting of hard drawn heavy duty copper refrigerant pipe of following sizes suitable for R-410A refrigerant for SUB & connections of refrigerant pipes to units along with 19mm thick closed cell elastometric nitrile rubber / EPDM tubular insulation between each set of indoor & outdoor units with outer mechanical protection of aluminium cladding etc. complete as per specifications and all piping inside the room shall be properly supported with MS / GI / STUDS / CLAMPS / HANGERS etc. complete as required. The thickness of copper pipe shall be as per OEM Standards.
-
-
-
... More
41.3 mm O.D. with 1.62 mm tube thickness (insulation : 19 mm)
50
10
-
... More
34.9 mm O.D. with 1.62 mm tube thickness (insulation : 19 mm)
50
22
-
... More
31.8 mm O.D. with 1.62 mm tube thickness (insulation : 19 mm)
50
-
-
... More
28.6 mm O.D. with 1.2 mm tube thickness (insulation : 19 mm)
50
10
-
... More
22.2 mm O.D. with 1.2 mm tube thickness (insulation : 19 mm)
100
22
-
... More
19.1 mm O.D. with 1.2 mm tube thickness (insulation : 19 mm)
100
10
-
... More
15.9 mm O.D. with 1.2 mm tube thickness (insulation : 19 mm)
150
10
-
... More
12.7 mm O.D. with 1.2 mm tube thickness (insulation : 19 mm)
100
22
-
... More
9.5 mm O.D. with 1.2 mm tube thickness (insulation : 19 mm)
150
-
-
... More
6.35 mm O.D. with 1.2 mm tube thickness (insulation : 19 mm)
100
10
-
... More
ITC of Y/T Joints/ Headers/Refnets including connection, welding, insulation etc. complete as required.
20
10
-
... More
Drain Piping:
Supply, installation, testing and commissioning of Rigid UPVC Class - 3 (6 kg/cm2) piping confirming to IS 4985-2000 for drain line complete with fittings, supports as per specification and duly insulated with 6mm thick closed cell nitrile rubber insulation etc. complete as required.
-
-
-
... More
25 mm dia x 6 mm insulation
150
22
-
... More
32 mm dia x 6 mm insulation
100
-
-
... More
40 mm dia x 6 mm insulation
50
10
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25 mm
100
22
-
... More
Control & Transmission Wiring:
Supply and drawing of 2 x 1.0 Sq.mm PVC insulated, PVC sheathed and shielded copper conductor control cum transmission Cable between indoor and outdoor unit & outdoor units to central remotes controllers as required in the existing surface/recessed steel/ PVC conduit etc. complete as required.
100
22
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
200
-
-
... More
Supplying & installation of Outdoor type Cable termination / looping box with hinged lids of minimum size 300 x 315 x 214 made of thermoplastic polycarbonate having minimum IP65 protection along with clamp etc. complete as required. (Make Hansel or Equivalent).
4
10
-
... More
Supply of 3.5 CORE 35 sq.mm. XLPE insulated and PVC sheathed FRLS aluminium conductor armoured Power Cable of 1.1KV grade, confirming to IS 7098, Part-I 1988 with up to date amendments and confirming to technical specifications.
100
22
-
... More
Supply of 3.5 CORE 70 sq.mm. XLPE insulated and PVC sheathed FRLS aluminium conductor armoured Power Cable of 1.1KV grade, confirming to IS 7098, Part-I 1988 with up to date amendments and confirming to technical specifications.
100
22
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
3.5 X 35 sq. mm
8
-
-
... More
3.5 X 70 sq. mm
2
10
-
... More
Laying of PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on wall surface as required.
-
-
-
... More
Up to 35 Sq mm (Clamped with 1 mm thick saddle)
50
22
-
... More
Above 35 Sq mm an up to 95 Sq mm (Clamped with 25 X3 mm MS flat Clamp)
50
22
-
... More
Laying of PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on cable tray as required.
-
-
-
... More
Up to 35 Sq mm (Clamped with 1 mm thick saddle)
50
22
-
... More
Above 35 Sq mm an up to 95 Sq mm (Clamped with 25 X3 mm MS flat Clamp)
50
22
-
... More
SITC of outdoor type totally enclosed double door junction box having IP-55 protection, made out of 14 SWG CRCA sheet steel ,free standing, floor mounting with angle supports, dust and vermin proof, powder coated painting includes 4P aluminium bus bars of minimum 250 A capacity with heat shrinkable coloured sleeves i/c SMC/DMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 35 KA for 1 sec. Panel should have 200 Amp, 36 kA MCCB as Incomer and 04 nos. 4P, 63 amp MCB as outgoing, interconnected with bus bar with 10 sq.mm size copper leads suitable for operation on 3 Phase and neutral, 415V, 50 Hz AC supply system with 2 Nos. earth stud, etc. complete as required.
1
22
-
... More
Earthing with G.I. Earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2
22
-
... More
Providing and fixing 25mm X 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation & refilling etc. as required.
8
22
-
... More
Providing and fixing 25mm X 5mm G.I. strip on surface or in recess for connections etc. as required.
30
22
-
... More
All Inclusive Comprehensive Maintenance Contract (AICMC) for VRV / VRF modular type air-conditioning units at Bikaner Airport comprising of items installed as per SH-I and other associate components etc. after successful completion of Defect Liability Period of ONE year.
The scope includes:
a) Monthly preventive maintenance visits by qualified service engineers for checking entire system serviceability with submission of service report.
b) Attending unlimited breakdown calls/complaints (24×7) by deploying experienced engineers.
c) Periodical cleaning, checking and maintenance of all components as per manufacturer's standards and recommendations.
d) Replacement of all defective parts/components including compressors, PCBs, sensors, fan motors, copper piping, insulation etc. complete as required.
e) Checking & servicing of associated circuit wiring, controls and other accessories.
f) Emergency response time within 4 hours for critical issues.
h) Maintaining proper records of all maintenance activities.
i) Top-up/replacement of refrigerant gas (R-410A) as and when required.
-
-
-
... More
For 1st year after DLP Period (4.51% of SITC Cost)
1
-
-
... More
For 2nd Year after DLP Period (5% escalation on 1st Year AICMC Cost)
1
1
-
... More
For 3rd Year after DLP Period (5% escalation on 2nd Year AICMC Cost)
1
-
-
... More
For 4th Year after DLP Period (5% escalation on 3rd Year AICMC Cost)
1
1
-
... More
For 5th Year after DLP Period (5% escalation on 4th Year AICMC Cost)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%