Panjab University Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Panjab University - PU Tender
Electrical and Electronics
Eprocure
Opening Date24 Jan 2025
Closing Date18 Feb 2025
Tender Amount₹ 27,21,046.05 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 55,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PU_84419_1Bid Award Id
ViewTender No
747STELECTTender Authority
Panjab University ViewPurchaser Address
-Website
http://https://puchd.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
3½ X 150 sq. mm (50mm) (DSR 9.1.26)
4
697
2788
... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required (DSR 14.16)
-
-
-
... More
120 mm dia (OD-120 mm & ID-103 mm nominal) (DSR 14.16.3)
50
368
18400
... More
Providing, Installing, Testing and Commissioning of 'Silent Type' Diesel Generating Set alongwith having Prime Power Rating of 125KVA, 415V at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50Hz, 3 phase system & for 0.85 Load Factor directly coupled to alternator mounted on a common base frame on existing foundation (the DG Set should comply with CPCB-IV+). The Engine should be of Turbo charged liquid cooled with radiator. The set should be complete with control panel fuel tank air cleaner blower fan fuel pump variable speed with Electronic governor fuel filter lube oil filter and pump, battery charger, 12/24V DC battery alongwith battery leads of compatible capacity & instrument panel comprising of switches with key, lube oil pressure gauge, water temperature gauge, battery charger, volt meter, safety control for low lube oil pressure over speed and high cooling water temperature with tripping etc. The Gen Set shall be provided with acoustic canopy as per technical specification. The set must be supplied completely assembled. The job includes making necessary connection of existing cables with lugs/ thimble upto control panel. The OEM should be authorized by principal company of manufacturer of Engine. The work is to be completed to the entire satisfaction of the EIC.
-
-
-
... More
Engine - Minimum 4 Cylinders minimum 154 BHP 4 stroke 1500RPM Liquid cooled engine with radiator of capacity taking 10% over load for one hour in any ten hours running & complete with fly wheel starter motor with following parts as under:-
-
-
-
... More
Radiator cooling systems
-
-
-
... More
Fly wheel to suite flexible/ rigid coupling
-
-
-
... More
Fly wheel housing complete with starter gearing and coupling
-
-
-
... More
Fuel hoses
-
-
-
... More
Electronic Governor with C.R.D.I
-
-
-
... More
Air cleaner with vaccum indicator
-
-
-
... More
Fuel and lubricant oil filter
-
-
-
... More
By pass filter
-
-
-
... More
Fuel pump
-
-
-
... More
Gear Driven water pump
-
-
-
... More
Lubricant oil pump
-
-
-
... More
Electric starter 12/24V DC
-
-
-
... More
Battery charging alternator with build in regulator
-
-
-
... More
Residential silencer
-
-
-
... More
Vibration damper
-
-
-
... More
Engine mounted anti vibration pads
-
-
-
... More
Flexible bellow for silencer
-
-
-
... More
Aletrnator- The Alternator shall be self-excited, self-regulated brushless and continously rated for 125KVA at 0.8 PF (lag) with IP23 protection, 50Hz, 3 phase 415V 50cycle 4 wire system and shall be provided with static excitation unit alternator insulation shall be class H suitable to withstand tropical conditions and shall generally comply with BS: 2613/5514 and IS 4722 including day fuel tank as required for 125KVA Diesel Generating set
-
-
-
... More
Other Features/ Protection on Engine Side
-
-
-
... More
Low loop oil pressure warning and shut down
-
-
-
... More
HWT Warning
-
-
-
... More
Low Coolant Temperature
-
-
-
... More
Low Coolant Level
-
-
-
... More
Fail to crank shut down
-
-
-
... More
Over crank shut down
-
-
-
... More
Over speed shut down
-
-
-
... More
Magnetic pickup failure shut down
-
-
-
... More
Emergency stop shut down
-
-
-
... More
Base Frame - Suitable base frame of Sturdy design made of MS/ banded channel as per OEM design with necessary re-enforcement to take the load of engine and alternator pre-drilled holes for permanent installation on pre-cast foundation with AVM (Anti-Vibration Mounting) pad including cost of the same. Make - TATA/ Jindal
-
-
-
... More
Fuel Tank - Daily service fuel tanks of 14 gauge having in built capacity as per OEM design with drain air vent inlet and outlet connection along with arrangement for fixing the same
-
-
-
... More
Battery - Battery of 12/24V suitable size (Maintenance free battery) of Exide/ Amaron/ Cummins Gen Power/ KOEL Green with battery lead for electrical starting
-
-
-
... More
Canopy - The Acoustic canopy should be powder coated weather proof enclosure (outdoor type) with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere, sound proof enclosure for installation of 125KVA DG set with following specification. The DG Set should meet the requirement of environmental latest CPCB-IV+ norms regarding emission and noise norms amended upto date. Sound proofing of the enclosure should be done with high quality fire retardant insulation material i.e. Rock wool/Glass wool/Mineral wool/ PU foam of appropriate thickness & density for sound absorption confirming to relevant IS to reduce the sound levels as per the latest CPCB Norms. Note - The D.G set canopy should be D.G set OEM Manufactured only. No Franchises/ Authorized Partner of any manufactured accepted)
-
-
-
... More
Outer Enclosure - The outer enlcosure is fabricated from CRCA 14/16 GMS Sheet powder coated paint. These sheets are first cleaned with a special chemical by giving anti rust grease and phosphate treatment
-
-
-
... More
Insulation - For sound alteraion a high quality insulation material is used on all five sides and the material is supported by MS/ AI perforated sheets
-
-
-
... More
Forced/ Natural Ventilation - The enclosure shall have natural ventilation/ forced ventilation system to maintain temperature as per manufacturer design
-
-
-
... More
Silencer - The enclosure is fitted with a special residential silencer to minimize back pressure on thee engine and to give max sound suppression of the exhaust gases
-
-
-
... More
The enclosure should be corrosion resistant wheather proof and suitable for outdoor installation. The enclosure can be placed on the RCC/PCC foundation without bolting the platform should have enough space to house panel, battery, fuel tank inside canopy
-
-
-
... More
Heavy duty sturdy steel base frame for placement of D.G set with AVM (Anti-Vibration Mounting) pads. The provision for air exhaust silencer for preventive leakage of sound. Maximum number of open-able door for access to virtually every part of DG set for complete maintenance. The acoustic material should be of suitable thickness and as per OEM design. The canopy should be manufactured by engine manufacturer/ OEM duly approved by ARAI (Automotive Research Association of lndia) CPCB for 75 dB(A) @ 1 Mtr. at 75% load under free field condition. The maximum permissible temperature rise above ambient shall be 5 degree Celsius to 7 degree Celsius inside canopy.
-
-
-
... More
The inside of enclosure should be provided with at least two nos. 20W LED tube light luminaire controlled by a 5A switch for adequate lighting during servicing etc. of the DG Set. The power supply to this luminaire should be from the load side of the AMF Panel so that it can remain energized under all conditions
-
-
-
... More
DG CONTROL PANEL WITH GENSET CONTROLLER:
-
-
-
... More
The Control Panel should be manufactured with 16/18 gauge CRCA sheet and is powder coated for a weather-proof and long lasting finish and consist of following
-
-
-
... More
Microprocessor based genset controller
-
-
-
... More
MCCB of 200A 4P 36KA, Ics= 100% of Icu
-
-
-
... More
Key switch
-
-
-
... More
Push Button (starter)
-
-
-
... More
LED: Battery Charging alternator fail indication
-
-
-
... More
Current Transformer
-
-
-
... More
Instrument fuses
-
-
-
... More
Indicating lamps for 'Load ON' and 'Set Running
-
-
-
... More
Bus bars with suitable capacity with incoming/
outgoing terminals
-
-
-
... More
The genset controller should have all the basic safeties and protections including the following features
-
-
-
... More
Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours
-
-
-
... More
AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. kwh, Total & per phase (kw & kVA), PF, Utility Voltage & Frequency
-
-
-
... More
Engine Protection: Low lube oil pressure, High/Low coolant temperature, Battery High/Low/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level
-
-
-
... More
AC Alternator Protection: Over/Under Voltage, Over/Under Frequency, Loss of AC sensing. Overspeed, Over Current, kW Overload
-
-
-
... More
Testing
-
-
-
... More
After completion of the installation work in all respects at site, the contractor shall offer the DG Set for testing
-
-
-
... More
DG set will be tested at site on load of unity power factor for the rated KW rating. During testing the D.G. set shall be operated for a period of 12 hours on the rated KW at DG set’s KW rating including one hour on 10% overload after continuous run of the 12 Hours. During testing all controls/ operations safeties will be checked and proper record will be maintained. Any defect/ abnormality noticed during testing shall be rectified. The testing will be declared successful only when no abnormality/ failure is noticed during the testing. For testing the cost of lubricating oil and HSD oil shall be borne by the firm
-
-
-
... More
Measurement of fuel oil consumption and lubricating oil consumption at 75% of full load
-
-
-
... More
Alternator efficiency at 75% & 100% load
-
-
-
... More
The measurement of noise level at 75% load
-
-
-
... More
Copies of all documents of routine and type test certificates of the equipment, carried out at the manufacturers premises shall be furnished to the EIC and consignee
-
-
-
... More
CPCB IV+ Certification
-
-
-
... More
Bidder should provide the certification of compliance with CPCB IV+ from any of the authorized agencies mentioned in CPCB IV+ notification i.e. Automotive Research Association of India, Pune (Maharashtra), International Center for Automotive Technology, Manesar (Haryana) and India Institute of Petroleum, Dehradun (Uttarakhand).
1
1770960
1770960
... More
Supply, Erection, Testing and Commissioning of Separate Outdoor type Heavy Gauge Sheet AMF panel suitable for 125 KVA Gen Set. The AMF panel is so designed that the Gen set starts automatically on complete failure of mains supply or fall of voltage and / or frequency below a preset value and takes over load. On restoration of mains supply the load ls automatically transferred back. On a three phase main supply. The set starts automatically on failure of one or more phases. The AMF panel should be cubical type construction and fabricated from Aluzinc coated CRCA SHEET -OUTER BODY/DOOR's-2MM & INTERNAL PARTITION /DOOR's/ CHANNELS-1.6/2MM) SUITABLE FOR OUTDOOR APPLICATION (DOUBLE DOOR TYPE) lP-54. The panel should be powder coated for a weather-proof and long lasting finish. The panel should be suitable for free standing floor mounting for outdoor installation. The panel should be provided rubber gaskets between all joints and opening to make it dust and vermin proof. Note - The A.M.F Panel should be OEM Manufactured only. No Franchises/ Authorized Partner of any manufactured accepted)
-
-
-
... More
2WAY 2POLE WITH OFF SELECTOR SWITCH (6A) - 1 No.
-
-
-
... More
2WAY 4POLE WITH OFF SELECTOR SWITCH (6A) - 1 No.
-
-
-
... More
BATTERY CHARGER (12V DC ,6A) - 1 No.
-
-
-
... More
SHUNT RELEASE , 240V AC.
-
-
-
... More
MCCB ,200A ,4 POLE , 36KA, TMD RELEASE with variable S/C and O/L (SPREADER+EXTENDED ROTARY HANDLE ) (Ics = 100% Icu). (FOR MAINS/DG Incoming) - 2 Nos.
-
-
-
... More
CONTACTOR (4P, 200A , AC-1 DUTY ) WITH 2NO+2NC - 2 Nos.
-
-
-
... More
CURRENT TRANSFORMER (200/5A) , CL-1.
-
-
-
... More
DIGITAL MULTIFUNCTION METER.
-
-
-
... More
EMERGENCY STOP WITH NO contact.
-
-
-
... More
LED INDICATOR (220V AC/12V DC).
-
-
-
... More
VOLTAGE MONITORING RELAY (UNDER/OVER VOLTAGE RELAY).
-
-
-
... More
OVER CURRENT & EARTH FAULT RELAY.
-
-
-
... More
ON LOAD CHANGE OVER SWITCH for BYPASS , 200A , 4POLE.
-
-
-
... More
MCB (SP,2A/6A/16A).
-
-
-
... More
PUSH BUTTON WITH NO/NC.
-
-
-
... More
BUS BAR- ALUMINIUM , (200A TPN) - Current density of Aluminium Busbar shall be 1mmx1mm=1 Amp.)
-
-
-
... More
WIRING COPPER -1.5 SQ.MM (AS REQUIRED).
1
190167
190167
... More
Supply, Installation, Testing and Commissioning of Factory fabricated indoor type U.P.S Input Panel fabriacated with 1.2mm Thick CRCA Steel Sheet (Wall Mounted Type Modular Enclosure) with all required accessories like locks, gasket, hinges, cable ties & all the other miscellaneous items. The panel shall be totally Modular Type having bolted structure (Partially Type Tested Assembly - PTTA) with IP42 degree of protection. The panel should be pre-treated with sand blasting treatment and duly painted with siemens grey powder coated paint complete in all respect to the entire satisfaction of the E.I.C. The panel should be got fabricated from authorized partners of Lauritz Knudsen (Core Metal Craft Ltd.) / ABB (EMCO Switchgear) / Schneider (N.G Energy Solution LLP)/ Siemens (ETE Electrogear Pvt. Ltd.) only.
-
-
-
... More
Incomer MCCB 160A 4P 36KA TMD Release with variable S/C and O/L Ics=100% of Icu - 1 No.
-
-
-
... More
Red, Yellow, Blue phase LED indicating lamp, Digital Ammeter, Voltmeter, VAF, PF Meter
-
-
-
... More
TPN Alumnium bus bar 200Amp (current density of Aluminium Busbar shall be 1mmx1mm=1 Amp.) Aluminium shall be Electric Grade E-91
-
-
-
... More
Outgoing MCCB 63A 4P 25KA, TMD Release with variable S/C and O/L Ics=100% of Icu= 2 Nos
-
-
-
... More
Outgoing MCB DP 63A 2P 10KA 'C' Curve = 8 Nos
-
-
-
... More
Space for MCCB 63A 4P - 1 No
-
-
-
... More
All connection /termination shall be solid. Approval of drawing is mandatory before manufacturing of panel without approval of drawing panel shall be rejected without information.
1
94574
94574
... More
Supply, Installation, Testing and Commissioning of Factory fabricated indoor type U.P.S Output Panel fabriacated with 1.2mm Thick CRCA Steel Sheet (Wall Mounted Type Modular Enclosure) with all required accessories like locks, gasket, hinges, cable ties & all the other miscellaneous items. The panel shall be totally Modular Type having bolted structure (Partially Type Tested Assembly - PTTA) with IP42 degree of protection. The panel should be pre-treated with sand blasting treatment and duly painted with siemens grey powder coated paint complete in all respect to the entire satisfaction of the E.I.C. The panel should be got fabricated from authorized partners of Lauritz Knudsen (Core Metal Craft Ltd.) / ABB (EMCO Switchgear) / Schneider (N.G Energy Solution LLP)/ Siemens (ETE Electrogear Pvt. Ltd.) only.
-
-
-
... More
Incomer MCB DP 63A 2P 10KA 'C' Curve - 2 Nos.
-
-
-
... More
Incomer MCB DP 32A 2P 10KA 'C' Curve - 8 Nos.
-
-
-
... More
Outgoing RCBO 25A 2P 10KA Sensitivity 30mA - 24 Nos.
-
-
-
... More
Space for MCBDP/RCBO 2P - 10 Nos
-
-
-
... More
All connection /termination shall be solid. Approval of drawing is mandatory before manufacturing of panel without approval of drawing panel shall be rejected without information.
1
143634
143634
... More
Supply and laying of XLPE insulated PVC inner sheathed aluminum conductor Armoured (4 CORE) cable of size 150 sqmm in existing D.W.C HDPE Pipe complete in all respect to the entire satisfaction of the Engineer-in-Charge.
189
1773
335097
... More
Supply and erection of XLPE insulated PVC inner sheathed copper conductor Armoured (10 core) Control cable of size 1.5 sqmm in existing D.W.C HDPE Pipe complete in all respect to the entire satisfaction of the Engineer-in-Charge.
60
520
31200
... More
Providing and fixing Exhaust pipe for extension of silencer for making the stack height as per norms of local pollution department for Silent DG 125KVA complete in all respect
-
-
-
... More
Supplying and fixing of 100mm dia MS Black pipe 'C' class (ISI marked) conforming to IS:1239 Part I cut to required lengths and welded with necessary bends, grinding including cost of transportation. The length of the exhaust pipe should be as per CPCB norms complete in all respect to the entire satisfaction of the EIC.
12
2250
27000
... More
Supplying and fixing of insulation of exhaust piping with mineral wool/ rockwool/ glasswool 50mm thick alongwith wiremesh and aluminium cladding of 22SWG on existing exhaust MS pipe of 100mm (4") dia complete as required at site to the entire satisfaction of the Engineer-in-charge.
12
1850
22200
... More
Providing & fixing MS steel support structure for the exhaust pipe by welding complete with all material such as M.S. Channel, M.S. Angle, M.S. Flat strip, Fastners etc. including painting complete in all respects.
-
-
-
... More
Providing and making of Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position In gratings, frames, guard bar, brackets and similar works and applying a priming coat of approved steel primer and two coats of approved syntheic enamel paint complete in all respect to the entire satisfaction of the EIC.
149
158
23542
... More
Foundation for D.G Set
-
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
-
-
-
... More
All kinds of soil
9
177
1597.5
... More
Supplying and filting in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
3
2123
6371.25
... More
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, D.G. set etc. including form work etc. as required.
6
7178
43072.5
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
... More
Thermo-Mechantcally Treated bars of grade Fe-500D or more.
250
107
26962.5
... More
Providing and laying in position reinforced cement concrele 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
8
8573
68587.2
... More
Providing 15 mm thick cement plaster of mix 1 :4 (1 cement : 4 fine sand) at all levels.
38
399
15179.1
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights:
-
-
-
... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
12
842
10110
... More
Total
-
-
-
... More
Buyback of Old & used D.G set 70KVA complete in all respect (Make - Kirlosker, Date of Manufacture - 06/02/2009, Engine No - 98827298)
1
200000
-200000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements