Baba Farid University Of Health Sciences Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Baba Farid University Of Health Sciences - BFUHS Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date5 Sep 2024
Closing Date18 Sep 2024
Tender Amount₹ 32,72,314 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 75,700
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 2,360

Summary

Extension Of Committee Hall Of Vc Office At Both Floors Of Senate Block Of Bfuhs, Fdk

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Extension of Committee Hall of VC Office at both floors of Senate Block of BFUHS, Fdk
Extension of Committee Hall of VC Office at both floors of Senate Block of BFUHS, Fdk
Financial bid for Extension of Committee Hall of VC Office at both floors of Senate Block of BFUHS, Fdk
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
For 90mm o/d pipes Elbow 90 Degree (Bend Plan)

2

120

241.7

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 1.5 sq.mm (Un-sheathed) 34.09 ii (18 + 30 % = Rs.23.40 + 5.35% = Rs.24.65)

185

24

4560.25

... More
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material

56.88

209

11927.74

... More
Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP, Anchor Anmol Heavy Duty BFUHS/UWD/2021/25524-30 Dt 20/12/2021

2

3501

7002

... More
Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (10 Core) 34.09 XIV a (173.00 + 30% = Rs.224.90 + 5.35% = Rs.236.93)

50

236

11846.5

... More
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications Heavy Gauge PVC Conduit Pipe 32mm dia.(On Surface) 34.12 III (59.00 + 40% = Rs.82.60 +5.35% = Rs.87.01)

70

87

6090.7

... More
20 mm thick cement plaster 1:5 on walls

169.97

263

44766.7

... More
Coupler

2

111

222.18

... More
Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect.

1

10585

10585.57

... More
Centring and shuttering for columns (Square or rectangular or polygonal in plain)

37.9

502

19045.51

... More
Moveable Portion

57.41

387

22257.28

... More
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.

49.32

7876

388489.2

... More
Re-barring ( Chemical Anchor) of 10mm dia bar, hole size 14mm, depth 100mm with 10 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) re-baring chemical complete in all respect

356

194

69384.4

... More
Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs RCBO Four Pole 63amp., Sensitivity 300mA 34.16 B XX (3886.00 + 15% = Rs.4468.90 + 5.35% = Rs.4707.98)

4

4707

18831.92

... More
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side

20.4

1209

24672.17

... More
Overall size 50sq.mm (3½ Core) Un-armoured (On-Surface) 34.10 C (xxiv) (217 + 25% = 271.25 +5.35% =RS 285.76 )

125

285

35720

... More
Extra rate for marble work at first floor

65.8

3

207.93

... More
Supply & erection of wiring light point 34.02 ii (579.00 + 25% =Rs.723.75 + 5.35 % = Rs.762.47)

32

762

24399.04

... More
HCI pipes

80.42

-2573

32

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions make approved by Engineer in Charge ,(Glazing and paneling to be paid for separately) Fixed portion

426.18

370

158040.33

... More
Providing and fixing commercial plywood 18mm thick

81.19

1315

106831.43

... More
Supply and erection of Ceiling Fan 1200mm (48") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High Speed Opel White, Anchor XL code14067 WH, Havell's Velocity HS BFUHS/UWD/2021/25524-30 Dt 20/12/2021

17

2201

37417

... More
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item)

16.44

128

2113.03

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure

34.12

7489

255539.01

... More
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling.

67.69

492

33346.12

... More
Supply and erection of sheet metal busbar chamber (factory fabricated ) duly powder coated on existing surface with required 4Nos. of tin plated copper busbar strips of suitable length and crosssectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site: Bus Bar Chamber 100amp., 415volts Overall Dimensions (455mm x 455mm x 150mm) nominal CSR 34.20 (v) 6339 + 20% = 7606.80 +5.35% = Rs 8013.76

1

8013

8013.76

... More
115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure

19.06

658

12546.82

... More
Extra rate for tile terracing at first floor

60.46

3

191.05

... More
Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge )including cutting, jointing, wastage, but excluding cost of lead jointing. (Type - B) 110mm o/d SWR UPVC pipe line laid complete

6.09

396

2412.61

... More
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete. ISI designation no I (Size of door up to 700mm)

5

1039

5199

... More
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.

42.81

5075

217280.44

... More
Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm

102.95

1436

147936.06

... More
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 34.23 C III (5576.00 + 40% = Rs.7806.40 + 5.35%= Rs.8224.04)

2

8224

16448.08

... More
Extra rate at first floor

57.76

10

608.79

... More
Supply & erection of wiring 16Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES 34.02 (VI) (363.00 + 25% =Rs.453.75 + 5.35% = Rs.478.02)

20

478

9560.4

... More
Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.

10.81

113

1229.96

... More
Extra for steel work done at first floor

24.66

13

337.84

... More
Terracing consiting of tiles 22.86x11.43 x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.

60.46

731

44223.47

... More
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)

36.68

221

8115.08

... More
Electrical Work Part (B) RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Supply & erection of Wiring fan point (With fan box) 34.02 I b (919.00 + 25% =Rs.1148.75 +5.35% = Rs.1210.20)

18

1210

21783.6

... More
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) 34.12 X (48.00 + 40% = Rs. 67.20 + 5.35% = Rs.70.79)

150

70

10618.5

... More
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm

2

1930

3860.02

... More
175mm i/d H.C.I. pipe

4.57

25

115.53

... More
Coupler

2

109

218.66

... More
Dismantling H.C.I Soil pipes including disposal as desired by the Engineer-in-Charge. 100mm i/d H.C.I. pipe

10.65

26

280.52

... More
Dismantling Reinforced Cement Concrete work

6.04

2321

14024.34

... More
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm

188.21

105

19827.92

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-chargeOverall size 10sq.mm (Un-sheathed) 34.09 (vi) (88 + 30% = 114.40 + 5.35% =Rs 120.52 )

20

120

2410.4

... More
Re-barring (Chemical anchor) of 25mm dia bar, hole size 32mm, depth 250mm with 100 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect.

16

1045

16721.12

... More
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth

10.72

6698

71805.13

... More
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB upto 125amp.) 34.17 XVI (7981.00 + 15% = Rs.9178.15 +5.35% = Rs.9669.18)

1

9669

9669.18

... More
Damp proof course 4 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded

7.19

377

2716.38

... More
Extra rate at first floor

17.14

190

3268.26

... More
Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipes Door Elbow 90 Degree (Door Bend)

2

198

396.18

... More
Providing and fixing ply wood, plain lining, butt jointed including PVC Plug placed at 45 cm to 65 cm centers complete with necessary nails (Frame work shall be payable extra) 6mm thick decorative ply wood teak faced on one side

116.34

987

114842.7

... More
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.

2

106

212.02

... More
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect

1

119

119.04

... More
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs MCB Single Pole 6-32amp. (10kA, Curve-C) 34.16 A ii (134.00 + 35 % = Rs.180.90 + 5.35% = Rs.190.57)

48

190

9147.36

... More
115mm thick brick wall in cement sand mortar 1:4 without reinforcement in foundations and plinth

1.03

643

663

... More
Dismantling asbestos cement celotax or other hard board ceiling or partition walls including supporting timber

40.28

46

1866.98

... More
Re-barring (Chemical Anchor) of 20mm dia bar, hole size 25mm, depth 200mm with 47 ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical complete in all respect.

48

666

32009.28

... More
Providing & Installing of copper pipe Indoor to outdoor unit for 3.5 ton cassatte unit 5/8, 3/8 including insulation complete in all respect as per satisfaction of Enginee

75

550

41250

... More
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc

115.51

560

64738.73

... More
Elbow 90 Degree (Bend Plan)

2

162

325.12

... More
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) 110mm o/d

10

101

1012.7

... More
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded inter connecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB upto 125amp.) 34.17 XVI (7981.00 + 15% = Rs.9178.15 +5.35% = Rs.9669.18)

2

9669

19338.36

... More
Re-barring ( Chemical Anchor) of 8mm dia bar, hole size 12mm, depth 100mm with 10ml injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) re-baring chemical complete in all respect

90

192

17351.1

... More
Extra rate for screed at first floor

56.88

3

179.74

... More
Providing and fixing glazing 5mm thick in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)

24.29

1090

26485.09

... More
P Trap/Floor Trap 110mm x 75mm

2

309

619.98

... More
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth

9.58

4931

47240.13

... More
Extra rate at first floor

30.09

10

317.15

... More
HVAC Work Providing & Installing & Erection of Ceiling mounted Cassatte type Air Conditioner 4 Ton, Gas R32, 4 Star, make Daikin/ Hitachi/ Carrier, 3 phase 415V 50 HZ, Cooling capacity 4200 complete in all respect as per satisfaction of Engineer in charge .

3

271700

815100

... More
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal

1

9002

9002.16

... More
Brick bats from burnt brick

15.85

-7489

472.5

... More
Udaipur Green Marble tile flooring with 15-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Slabs sizes above 0.50 sqm

131.6

1253

164982.97

... More
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 34.23 C III (5576.00 + 40% = Rs.7806.40 + 5.35%= Rs.8224.04)

1

8224

8224.04

... More
Extra rate at first floor

18.95

10

199.73

... More
Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavationEarthing with 25mm x 3mm Copper Tape (upto 8Metre in Length) 34.14 ii b (9906 + 40% = Rs.13868.40 + 5.35% = Rs.14610.35)

2

14610

29220.7

... More
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels

58.39

400

23375.27

... More
Providing polyster powder coating 50 micron any colour specified to aluminium section of various sizes including carriage of material from maket to workshop.

483.59

71

34644.39

... More
Cement concrete 1:5:10 with 40 mm gauge stone ballast using mechanical mixer

3.79

4141

15697.76

... More
Cleaning of building Rubbish from site to outside building premises lead 5 kms.

11.13

219

2440.59

... More
75mm i/d H.C.I. specials

2

27

54.78

... More
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 35 sq.mm (3½ Core) Un armoured (On Surface) 34.10 C (xxiii) ( 170 + 25% = Rs. 212.50 + 5.35% = Rs.223.86)

20

223

4477.2

... More
Civil Work Part (A) Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.

6.68

109

731.86

... More
Providing & Fixing in position mirror of superior glass Size 1500mm x600mm or any other required size (of approved quality) and of required shape and size with high quality polystyrene moulding frame of 40 to 50mm size (of approved quality and shade) with 4mm thick hardboard backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect

1

2360

2360.89

... More
Spirit polishing two coats including a coat of wood filler on wood work

123.49

161

19904.12

... More
Wiring 6Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES 34.02 (V) (282.00 + 25% Rs.352.50 + 5.35% = Rs.371.35)

20

371

7427

... More
Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.

66.33

589

39068.37

... More
Plastering on underside of ceiling 10mm thick cement plaster 1:4

150.68

184

27779.36

... More
Dismantling H.C.I specials including dismantalling of lead joints including cartage / disposal within 5 Km. 100mm i/d H.C.I. specials

3

34

104.31

... More
Extra rate at first floor

18.45

153

2837.79

... More
20 mm thick cement plaster 1:4 in two coat wark

20.68

277

5729.81

... More
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body. Size 600x600 mm

10.81

1104

11935

... More
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade

169.97

79

13429.33

... More
Recovery of Material Bricks

5325

-23962

4.5

... More
Supply & erection of Recess mounted white powder coated CRCA housing wth full window acrylic diffuser LED Panel 2'x2' 36w of make Crompton including cutting of ceiling , erection, connections and testing etc. of the same with petty material as required at site complete in all respects. ICCU Medicine BFUHS/UWD/2023/6302-09 Dt 11/05/2023

28

2725

76300

... More
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation

45.46

191

8716.5

... More
90mm o/d

8

85

685.6

... More
Dismantling brick work tile, masonry or tile lining In cement

31.7

718

22776.13

... More
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects

2

116

233.16

... More
90mm o/d SWR UPVC pipe lines laid complete

6.09

344

2099.16

... More
Supply & erection of High quality aluminium extruded with decorative end caps glazed 20 watt LED batten of Crompton including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer in-charge at site. BFUHS/UWD/2019/10622 Dt 27/05/2019

15

521

7815

... More
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.

4

142

568.88

... More
Re-barring (Chemical Anchor) per hole for 16mm dia bar, hole size 20mm, depth 160mm with injectable mortar epoxy adhesive (Hybrid urethane methacrylate adhesive) rebaring chemical 24 ML

32

459

14698.24

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 4 sq.mm (Un-sheathed) 34.09 iv (39 + 30 % = 50.70 + 5.35% = Rs.53.41)

370

53

19761.7

... More
Labour cost of Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm

62.88

245

15435.15

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge Overall size 6sq.mm (Un-sheathed 34.09 V (54 + 30% = Rs.70.20 +5.35% = Rs.73.95)

255

73

18857.25

... More
Providing and fixing in position the following PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated with 6 mm thick insulationas per specifications. 32 mm dia pipes

25

175

4375



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.