Works Department Tender

... More
The Works Department has issued a formal invitation for competitive bids for Design Manufacture Supply Installation Testing And Commissioning Of 1no Automatic 16 Passenger Streacher Type Lift G Plus 4 With Stainless Steel Car Cabin Finish With Ard System For New Medicine Department Of Scbmch Cuttack in Cuttack, Odisha, with an estimated contract value of Rs. 29,48,813. The bid opening date for this tender is 06-11-2026 and the last date for bid submission is 20-11-2026. Interested bidders for Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Works Department Tender - Orissa Tender

Opening Date6 Nov 2026
Closing Soon20 Nov 2026
Tender Amount₹ 29,48,813 
Notes
Download

Costs

Description

Design Manufacture Supply Installation Testing And Commissioning Of 1no Automatic 16 Passenger Streacher Type Lift G Plus 4 With Stainless Steel Car Cabin Finish With Ard System For New Medicine Department Of Scbmch Cuttack

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Supply and fixing of Multipurpose board having prov. Of 2Nos 6Amp plug with 6Amp switch on existing board (Modular) (Make-Legrand )

2

1340

2680

... More
Recessed Extra lead Sub-main wiring for light and fan point 2x1.5mm2 FR PVC insulated single core multistrand copper conductor of ISI Marked confirming to IS-694/1990 in 20mm dia nonmetalic heavy duty flexible conduct 1.6 sqmm thick along with 1x1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor / Finolex/Polycab) 2x1.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990

70

157

10990

... More
Recessed wiring to Sub-main in 2x2.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x1.5sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor / Finolex/Polycab) 2x2.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990

40

171

6840

... More
Recessed wiring to Sub-main in 2x6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x2.5sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge(Make of wire Finolex / Havells / Anchor / Finolex/Polycab) (Mainswtich/Busbar to MCB DB box) 2x6 sq mm+1x2.5 sqmm 1100 Volts confirming to IS 694/1990

20

219

4380

... More
Supply and fixing of SP 6-32 A rating 240 V "C" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand/siemens)

6

380

2280

... More
Supply and fixing of DP 6-32 A rating 240 /415V "C" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand/siemens)

1

1134

1134

... More
Supply and fixing of FP 63 A rating 240 /415V "C" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand/siemens)

2

3492

6984

... More
S/F of 4way TPN Double Door MCB Box on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand/siemens)

1

3422

3422

... More
S/F of copper plate earthing 600*600*3 mm with alll materials complete in all respect as per specification of SR 2011 and as per Direction of Engineer-in -Chage

2

18137

36274

... More
Supply and laying of 8 swg copper wire in recess/surface

80

148

11840

... More
S/F of 100 A cubical panel board made of 16 SWG C.R sheet with powder coated with provision of following items with fabrication erection testing & comissioning of total enclosed panel board of size not less than 28"x16"x7" with copper busbar of 100A, with 40 ka type 1+2 SPD 415V 4strip & internal connection & provision for termination of incomming & out going cable , earthing etc, complete with supply & fixing of following switch gears. technical specification:

1

18415

18415

... More
Supply and fixing of 4 pole MCCB 63-100A,Ics = 100% Icu, 25 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand/siemens)

1

11442

11442

... More
Supply of 35 sq. mm 3 1/2 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex/HPL)

145

415

60175

... More
LAYING OF CABLE UPTO 50mmsq. mm 3 ½ Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex/HPL)

140

81

11340

... More
S/F of 12 inch Heavy duty (Metalic Colour) Exahust Fan with wall cutting, S/F of proper size of hume pipe, concreating, plastaring, painting with all connection testing and commissioning complete in all respect as per direction of Engineer in charge Make:(Orient PSPO summer cool/Crompton High breeze/Almonard/Khaitan)

4

3318

13272

... More
Supply and fixing of Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) IEC 62053-21 complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : legrand ) (Make : Schneider (ACTI 9 ) /legrand/siemens)

1

3879

3879

... More
Supply and fixing of bulkhead 10 watt on wall ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Pansonic/ Great white/crompton/ wipro)

8

942

7536

... More
Supply and fixing of 20watt,CW/WW 6500K,1800 Lumen Alluminium led batten on wall ,making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Pansonic/ Great white/ LT/ wipro)

4

758

3032

... More
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.Materials with the IS specifications not valid now, we have consider new IS products rates, i.e. IS 15683.Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wal mounting bracket etc. complete, confirming to IS: 15683.

2

7710

15420

... More
Supply & Fixing of 2.0 TR high wall 5 satr inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years Manufacturer warranty on PCB & Compressor complete in all respect as per Direction of Engineer-in-Charge. (Make:O-General/Diakin/Mitsubishi)

2

67108

134216

... More
S/F of 5 KVA (130V – 280V) Voltage Stabilizer complete in all respect as per Direction of Engineer-in-Charge. (Make- V-GUARD / Microtek)

2

7067

14134

... More
S/F Copper cooling Piping with Insulation and Power Cable for 1.5/2 Ton Split AC complete in all respect as per Direction of Engineer-in-Charge.

10

1070

10700

... More
S/F of Nylon Netted Drain Pipe with C clamp complete in all respect as per Direction of Engineer-in-Charge.

10

225

2250

... More
S/F of Powder coated Wall Stand for outdoor unit with Anchor Fastener (For 1.5/2 Ton) complete in all respect as per Direction of Engineer-in-Charge.

2

2050

4100

... More
S/F of Timer panel Board

1

33294

33294



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.