Institute Of Minerals And Materials Technology Tender
... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Institute Of Minerals And Materials Technology - IMMT Tender
Civil And Construction
Building Construction
Eprocure
Opening Date20 Feb 2025
Closing Soon27 Feb 2025
Tender Amount₹ 72,66,626
Costs
EMD
₹ 1,45,333Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Renovation Of Both Side Of S. S. Bhattanagar Hall (civil And Electrical) At Csir-immt, Bhubaneswar
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CSIR_225619_2Tender No
22/2024-25/ESD(C)/IMMT/BBSRTender Authority
Institute Of Minerals And Materials Technology ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Renovation of both side of S. S. Bhattanagar Hall (Civil and Electrical) at CSIR-IMMT, Bhubaneswar
BOQ Items
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1.5
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
3.5
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
11
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floor s,roof,landing ,balconies and access platform
36
-
-
... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars
270
-
-
... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 7.5 average compressive strength in foundation and plinth in: :Cement mortar 1:6 (1 cement : 6 coarse sand)
2
-
-
... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 7.5 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:6 (1 cement : 6 Coarse sand)
21
-
-
... More
Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour lakha red Area of slab over 0.50 sqm
81
-
-
... More
Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid without cement mortar moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour lakha red Area of slab over 0.50 sqm
2.5
-
-
... More
Providing and fixing wooden moulded decorative beading of any shape etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood.50x50 mm (base and height)
144
-
-
... More
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coup er (where ever required) extruded profiles having minimum wall thickness of 1,70 mm for Series R1 and R2 profiles and 2,10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mi d steel section made of required shape & size as per CPWD Specification, uPVC extruded g azing beads, interlocks and Jn ine sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS
304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per JS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stain ess steelscrews etc.Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled withweather proof si icon sea ant over backer rod of approved size and quality, all comp ete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steelreinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.For Fixed windows/ventilators with mulion /transom.Using R2 Series with bframe (39mm &above )X(39mm &above )& mulion(39mm &above )X(60mm &above )(Height up to 1.20 Mtr)
(Wire mesh /glazing of plain/toughtened/laminated/double glass unit with /without high performance shall be paid separately)
27
-
-
... More
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coup er (where ever required) extruded profiles having minimum wall thickness of 1,70 mm for Series R1 and R2 profiles and 2,10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mi d steel section made of required shape & size as per CPWD Specification, uPVC extruded g azing beads, interlocks and Jn ine sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per JS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stain ess steelscrews etc.Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled withweather proof si icon sea ant over backer rod of approved size and quality, all comp ete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steelreinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Three track ,three pannels sliding window with two glazed & one wire mesh panels with aluminum chanel for roller track,wool pile,nylon rolles with SS 304 body.Using R3 series with frame (98mm &above )X(40mm &above )& both glazed and fly screen sash mulion(30mm &above )X(55mm &above ) with zink alloy powdwe coated handle on every glazed paneel along with multi point locking system.(Height up to 1.80 Mtr)
(Wire mesh /glazing of plain/toughtened/laminated/double glass unit with /without high performance shall be paid separately)
22.5
-
-
... More
Providing and fixing fly proof galvanized S.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm UPVC U beading
5.5
-
-
... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles polished finish of Size of Tile 600 x 1200 mm
288
-
-
... More
Providing and fixing polished glazed vitrified tiles (600X1200 mm) for wall conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades including rustic,satin,sugar finish/matt finish as approved by Eningeer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
50
-
-
... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg),including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x1200 mm
338
-
-
... More
Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. ( - )
338
-
-
... More
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/ mK.
160
-
-
... More
Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
192
-
-
... More
12 mm cement plaster of mix :1:6 (1 cement : 6 coarse sand)
135
-
-
... More
15 mm cement plaster on rough side of single or half brick wall of mix1:6 (1 cement : 6 coarse sand)
135
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
461
-
-
... More
Finishing walls with Acrylic Smooth exterior paint (Apex of Asian Paint) of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm) (Agency shall bring colour container at a time & make signature of official, before start the work and keep the container till final bill is passed)
187
-
-
... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
4
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
15
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres
13
-
-
... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
20
-
-
... More
Dismantling tile work in floors laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
159
-
-
... More
Dismantling aluminium partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
67
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
2
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External wall 25 mm dia nominal bore
20
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External wall 50mm dia nominal bore
40
-
-
... More
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings ,etc and all complete as per direction of Engineer in charge including 600 mm length SS Door handle, lock and stopper etc.
42
-
-
... More
Providing and fixing 12mm thick frameless toughened glass partitions (Fixed) of approved brand and manufacture, including providing and fixing top & bottom pivot and other fixing arrangement . for fixing required fittings ,etc and all complete as per direction of Engineer in charge .
18
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
370
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
49
-
-
... More
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
310
-
-
... More
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. Upto and including 12mm dia.
40
-
-
... More
Providing and fixing of thin rim table top basin of size 495X395X150 mm of Jaquar make make model-JDS-WHT-25909 1including all acessories etc.
2
-
-
... More
Providing and fixing of pillarbcock for wash basin of Jaquar make -model no-VGP-SSF-81021N 1including all acessories etc.
2
-
-
... More
Providing & fixing 8 mm thick Non -asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (high pressure steam cured ) as per IS 14862 with suitable fibre cement screw in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
74
-
-
... More
Providing and fixing of decorative glass film over 12 mm thick toughen glass partition of approved design as per direction of EIC.
60
-
-
... More
Providing & fixing 12mm thick Louvers/Flutted pannel of size-2450mmX175 mm of approved make and colour with Royal bond / Fevicol Nail free Ultra quick set adhesive over 8mm thick WPC board fixed on wall with necessary screq etc as per the direction of the EIC.
118
-
-
... More
Providing and fixing of decorative Excell wall coverings(Korean wall paper) over putty finished wall including necessary adhesive etc as per direction of EIC.
207
-
-
... More
Providing and fixing of Zebra roller blind with decorative cassette of VISTA make as per the direction of EIC.
49
-
-
... More
Providing and fixing of 4.00 mm charcoal wall panelling planks of size-2450mmX600mm over 8mm thick WPC board which shall be fixed over the pillar surface with necessary screw, nail free/quickset adhessive as per direction of EIC.
80
-
-
... More
Providing and fixing of golden corner angel (20mmX20 mm) with necessary ,silicon or anty suitable ashessive
176
-
-
... More
Providing and fixing of WPC jali (made up of 12 mm thick WPC board) over existing calcium silicate plain false ceiling as per approved pattern and design , to be cut through CNC cutting technique. 5 mm thick white acrylic sheet (edges chamfered) to be fixed on top of the jali for lighting purpose, which includes necessary adhessive screw and other hard wares if any etc all completeas per direction of the EIC (Payment shall be made as per the total area covered with WPC board)
14
-
-
... More
Providing and fixing of decorative MDF profile (made up of 25mm thick MDF board) of approved pattern suspended over false ceiling. The MDF profile shall be designed and cut through CNC cutting technique. The molded edges and surface of the profile shall be smooth finished with sand paper grinding and filled with wood filler. The profile shall be finished with three or more coats of matt finished satin paint of approved shade over two coat of wood primer .The profile shall be fixed on roof slab over the ceiling with required SS studd/string of approved dia and length as per direction of the EIC. (Payment shall be made as per the total covered area without over lapping)
13
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm (Finolex/ Poly-Cab/RR / KEI make or as approved by dept) ISI marked FRLS PVC insulated single core copper conductor cable in surface/ recessed PVC conduit medium class (Kinjal/ AKG /Polycab make make or as approved by dept) with modular type 5A switch, modular base & cover plate on suitable size modular type metal box (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept) make incorporated with Neutral & Earth link & earthing the point with 1.5 sq mm FRLS PVC insulated single core copper conductor cable etc as required. Group – C
109
-
-
... More
Supply and fixing 5/6 amps.modular type (1 module)switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
48
-
-
... More
Supply and fixing15/16 amps.modular type (1 module) switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
48
-
-
... More
Supply and fixing 5/6 amps.modular type socket (2 module) on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
48
-
-
... More
Supply and fixing 5 pin, 15/16 amps.modular (2 module) type socket on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
48
-
-
... More
Supply & fixing of modular type RJ-11 telephone socket in the existing modular box for telephone connection including connection etc as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
5
-
-
... More
Supply & fixing of modular type RJ-45 internet socket in the existing modular box for telephone connection including connection etc as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
20
-
-
... More
Supplying and fixing Modular stepped type electronic fan regulator, 2 module, 120W in the existing modular switch box including connection etc as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
11
-
-
... More
Supply and fixing of 1 or 2 module, modular base & cover plate on existing modular box etc. as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept).(colour of the modular face plate will be choosed as per site requirement & approved by the dept)
25
-
-
... More
Supply and fixing of 6 module, modular base & cover plate on existing modular box etc. as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept).(colour of the modular face plate will be choosed as per site requirement & approved by the dept)
48
-
-
... More
Supply and fixing of 1 or 2 module (75mm x 75mm) modular type metal box (GI) on surface or in recess etc. as required.
14
-
-
... More
Supply and fixing of 6 module (200mm x 75mm) modular type metal box (GI) on surface or in recess etc. as required.
30
-
-
... More
Supply and fixing extra down rod of 20cm length GI/MS pipe , 15mm dia (heavy gauge) including painting etc as required.
55
-
-
... More
Supplying and drawing of 2pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required
100
-
-
... More
Supplying and fixing of 20 mm dia PVC conduit in surface/recessed PVC conduit medium (Kinjal/ AKG /Polycab make make or as approved by dept) including cutting the wall & making good the same in case of recessed conduit etc. as required.
180
-
-
... More
Supplying and fixing of 25 mm dia PVC conduit in surface/recessed PVC conduit medium (AKG/Kinjal/Polycab or as approved by dept) including cutting the wall & making good the same in case of recessed conduit etc. as required.
80
-
-
... More
Supplying and drawing of UTP 4pair CAT-6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required
400
-
-
... More
Supply and fixing metal box of 200 mm x 300 mm x100 mm deep (For AC starter enclosure) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required.
10
-
-
... More
Supplying and drawing 2 x 1.5 sq mm of FRLS PVC (Finolex/ Poly-Cab/RR / KEI make or as approved by dept.) insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit/ PVC Trunking as required.
176
-
-
... More
Supplying and drawing 3 x 1.5 sq mm of FRLS PVC (Finolex/ Poly-Cab/RR / KEI make or as approved by dept.) insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit/ PVC Trunking as required.
160
-
-
... More
Supplying and drawing 3 x 4 sq mm of FRLS PVC (Finolex/ Poly-Cab/RR / KEI make or as approved by dept.) insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit/ PVC Trunking as required.
620
-
-
... More
Supplying and drawing 6 x 4 sq mm of FRLS PVC (Finolex/ Poly-Cab/RR / KEI make or as approved by dept.) insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit/ PVC Trunking as required.
60
-
-
... More
Supplying and drawing 6 x 10 sq mm of FRLS PVC (Finolex/ Poly-Cab/RR / KEI make or as approved by dept.) insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit/ PVC Trunking as required.
40
-
-
... More
Supplying and fixing of 4 (4+12)way, Double Door, three pole and neutral, sheet steel, MCB distribution board , 415 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make or as approved by dept.
4
-
-
... More
Supplying and fixing of single pole 6 to 32 amps rating, 240 volts MCB (C series) of Legrand/Hager/Siemens/ C &S make or as approved by dept in the existing MCB DB complete with connections, testing and commsissioning etc. as requried.
37
-
-
... More
Supplying and fixing of TPN 32 amps rating, 240 volts MCB (C series) of Legrand/Hager/Siemens/ C &S make or as approved by dept in the existing MCB DB complete with connections, testing and commsissioning etc. as requried.
3
-
-
... More
Supplying and fixing 63amp, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make or as approved by dept
4
-
-
... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (Legrand myrius /schneider clipsal/anchor woods make or as approved by dept)
7
-
-
... More
Providing and fixing 4 mm dia copper wire on surface or in recess along with existing cable for loop earthing etc as required.
120
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for 4 core x 10 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
1
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core x 35 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
2
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core x 50 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
2
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core x 70 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
9
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core x 95 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
2
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 core x 70 sq mm size in the existing masonry open duct as required.
10
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 core x 70 sq mm size, (clamped with 25 *3 ms flat clamp) on wall surface as required.
30
-
-
... More
Supplying & installation, testing and commissioning of smoke detector with builtin LED and mounting base complete with all connections etc as required.
34
-
-
... More
Supplying & installation, testing and commissioningmanual call box of ABS type in surface or recess etc. complete as required.
1
-
-
... More
Supplying & installation, testing and commissioning fire alarm sounder, mounted on ABS box etc. complete as required.
1
-
-
... More
Supplying, installation, testing & commissioning of fire alram control/selector panel suitable for 6 Zones complete with visual indications for fault condition, fire condition and all other standard facility as per IS 2189 with mimic diagram for all area / zone covered complete with all connection, interconnection etc as required.
1
-
-
... More
Supply & laying of 2 x 1.5 sqmm fire alarm armoured cable , 600/1000V rated with annealed copper conductor having XLPE insulation, stell wire armouring & FRLS outer sheath complete as required.
200
-
-
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Suitable for operation on Electronic regulator unit for speed control. (Havells / Crompton / Usha/ Orient or as approved by dept)
11
-
-
... More
Supplying, installation, testing and commissioning of outdoor floor mounted double door type , cubical compartmentalized electrical panel made out of 2 mm thickness of metallic sheet steel of tentative panel size 0.9mtr height, 1.5 mtr width & 0.3 mtr depth (or as approved), including supplying, installation & internal wiring of following mountings, to be mounted on civil concrete/brick pedastal (minimum 0.3 mtr height from ground level) complete as required, duly acid treated for derusting, primered and painted with powder coating of approved shade as per drawing approved by engineer in charge. a) Incommer :- One number 200 A, 36KA, FP MCCB with rotary handle, thermomagnetic release & terminal speaders SIEMENS / L & T / C & S/ Legrand make or as approved by dept.
b) Outgoing:-Two numbers 125 A, 36KA, FP MCCB with rotary handle, thermomagnetic release & terminal speaders SIEMENS / L & T / C & S/ Legrand make or as approved by dept.
c) Outgoing:- Four numbers 63 A, 36KA, FP MCCB with rotary handle, thermomagnetic release & terminal speaders SIEMENS / L & T / C & S/ Legrand make or as approved by dept.
d) One number bus-bar chamber comprising four strips (200 amp , 100% neutral ) copper bus-bar of suitable length mounted on insulator etc as required
1
-
-
... More
Supplying & fixing of PVC Trunking /duct System of size 100mm*50mm for cable management (Make- Legrand/ AKG / Maruti/precision make or as approved by dept) as required as per site requirement.
90
-
-
... More
Supplying & fixing of PVC Trunking /duct System of size 50mm*50mm for cable management (Make- Legrand/ AKG / Maruti/precision make or as approved by dept) as required as per site requirement.
100
-
-
... More
Supplying & testing of 400 mm sweep pedastal fan (metal body & metal Blade) with inbuilt regulator of (Havells / Crompton / Usha/ Orient make or as approved by dept.)
6
-
-
... More
Supplying & installation, testing and commissioning of prewired recessed mounting downlighter square LED fitting, 2ft x 2 ft of 3000lumen, 30watt (approx), more than 100lumen/watt (Philips /Passolite/ Klite or as approved by dept) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
48
-
-
... More
Supplying & installation, testing and commissioning of prewired LED fitting of size 4ft x 1 ft of 3000lumen, 30watt (approx), colour temp 3000-4000K (warm white), more than 100lumen/watt (Philips /Passolite/ Klite or as approved by dept) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
4
-
-
... More
Supplying & installation, testing and commissioning of prewired round LED fitting, of 2000lumen, 20watt (approx), more than 100lumen/watt (Philips /Passolite/ Klite or as approved by dept) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
14
-
-
... More
Supplying & installation, testing and commissioning of prewired recessed mounting downlighter round LED fitting, of 1000lumen, 10watt (approx), more than 100lumen/watt, colour temp 3000-4000K (warm white) (Philips /Passolite/ Klite or as approved by dept) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
58
-
-
... More
Supplying & installation, testing and commissioning of prewired slim batten led light of size 4ft, 20W (approx), 2000lumen, colour temp 3000-4000K (warm white) (Philips /Passolite/ Klite or as approved by dept) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
44
-
-
... More
Supplying & installation, testing and commissioning of prewired slim batten led light of size 2ft, 9W (approx), 900lumen, colour temp 3000-4000K (warm white) (Philips /Passolite/ Klite or as approved by dept) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
16
-
-
... More
Supplying & installation, testing and commissioning of starter for Air-conditioner, 3-phase DOL starter L&T /Siemens/ C &S make or as approved by dept, coil voltage-230 ,Volt 50HZ. & O/L range 9-14 Amps on existing M.S. Box, etc as required .
10
-
-
... More
Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex/ KEI/ RR Kable make or as approved by dept) armoured cable of 3.5 core x 70 sq mm size, Aluminium etc as required.
40
-
-
... More
Supplying & installation, testing and commissioning of 125amp, 415V, four pole manual change over switch in sheet steel enclosure etc as required. SIEMENS / L & T / C & S/ Legrand make or as approved by dept.
1
-
-
... More
Shifting of one wall mounted electrical panel (size: 1000 x 1100 x 250mm approx) from left side of bhatnagar hall and reinstallation of the same panel at a new location on the existing wall surface etc as required as per direction of engineer incharge.
1
-
-
... More
Dismantling of old electrical & network wiring (on left side of Bhatnagar hall of IMMT) and refixing the wiring in existing PVC trunking /PVC conduit etc as per direction of engineer incharge.
1
-
-
... More
Supply, installation, testing and commissioning of Split Air conditioner of 1.8 Ton (wall mounted), BEE 5 star rated, inverter model, Cooling capacity (at 100%): 5800 KW , environment friendly refrigerant, copper condenser alongwith upto 3mtr copper pipe, Hard PVC drain pipe, insulation wrapping tape & electrical cable required from indoor to outdoor unit, Heavy duty wall mounting stand for for installation of outdoor unit remote control with all accessories etc as required. Make:-Voltas, Daikin, Carrier, Hitachi, Mitshubushi, O-General, Blue star or as approved by dept.
6
-
-
... More
Supply, installation, testing and commissioning of 4.0 Ton Tower AC (split, floor mounted) , Cooling capacity (at 100%) : 12660 KW, 100% copper condenser, alongwith upto 3mtr copper pipe, Hard PVC drain pipe, insulation, wrapping tape & electrical cable required from indoor to outdoor unit, Heavy duty wall mounting stand for installation of outdoor unit with all accessories etc as required. Make:- Daikin, Voltas, Carrier, Hitachi, Mitshubushi, O-General, Blue star or as approved by dept.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%