Department Of Power Tender

... More
The Department Of Power has issued a formal invitation for competitive bids for Construction Of 33 Kv Line From Sangsangnyu To Tobu And 33/11 Kv, 2.5 Mva Sub-station At Tobu Under Mon. in Kohima, Nagaland. The bid opening date for this tender is 14-03-2025 and the last date for bid submission is 25-03-2025. Interested bidders for Department Of Power tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.

Department Of Power Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Mar 2025
Closing Date25 Mar 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HT Power Cables

-

-

-

... More
Stay set 19 mm dia. 1.6 Mtr length with stay rod and bow plate

240

-

-

... More
POTENTIAL TRANSFORMER

-

-

-

... More
OVERHEAD CONDUCTOR

-

-

-

... More
PVC insulated AL armoured Power cables 2 xC, 25 sqmm

50

-

-

... More
Isolator suitable for a system voltage of 33 KV, rated current of 400 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITHOUT EARTH SWITCH

2

-

-

... More
GI Steel Tubular Pole SP 76 (33KV bay- 4 nos, 11KV bay 6 nos )

10

-

-

... More
Supply of 11kv, single pole, single phase,outdoor type with ratio 200-100/1A, 15 VA burden, class accuracy 0.5 Line CT for metering, The CTs will be complete with bimetallic terminal for connecting ACSR wires, whether proof secondary terminals,

9

-

-

... More
Control Room Auxiiaries

-

-

-

... More
33/11KV, 2.5 MVA Oil Type Transformer

1

-

-

... More
GI Stay wire 7/10 SWG weighing 43.4 kg per 100 mtr coil. 12 mtr per stay

1560

-

-

... More
33 KV ISOLATOR

-

-

-

... More
DISCHARGE ROD

-

-

-

... More
33KV SIDE EQUIPMENT

-

-

-

... More
40mm dia GI pipe

100

-

-

... More
33 kV Pin Insulator, complete with GI pin

252

-

-

... More
Supply of 10 C X 2.5 mm sq.

300

-

-

... More
25X3mm GI Strip

100

-

-

... More
24V, 65AH, Lead Acid type Battery Set at 10 Hr Discharge Rate consisting of 11 Nos., each of 2.2V Cell having float level indicators, terminal connectors along with suitable wooden rack, required quantity of acid, distilled water & all other accessories and connectors required for installation, testing & commissioning as per technical specifications.

1

-

-

... More
The isolator shall be suitable for a system voltage of 11 KV, rated current of 800 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITHOUT EARTH SWITCH

1

-

-

... More
11 KV Control & Relay Panels

-

-

-

... More
PVC Insulated CU unarmoured Power cables1C x 25 SQ.MM.

8

-

-

... More
A. Supply of Materials for Construction of 33 KV Line

-

-

-

... More
ACSR Mink 6/1/3.66 mm

37.2

-

-

... More
GI Nuts & Bolts 5/8" x 3" (16x200 mm)

120

-

-

... More
CURRENT TRANSFORMER (METERING AND PROTECTION)

-

-

-

... More
70 KM Ball & Socket (B&S) Type 11 kV Disc Insulator, complete

1116

-

-

... More
Indoor Relay and Control Panel (consisting of OC/EF numeric relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Feeders Incomer) Breakers

1

-

-

... More
B. Supply of Materials for Construction of 2.5 MVA Sub-Station

-

-

-

... More
Supply & fixing of Steel Fabricated items, additional requirement.

1.5

-

-

... More
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Differential relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - for Transformers HV Incomer Breakers

1

-

-

... More
Supply, of following Transformers

-

-

-

... More
Steel tubular pole SP 45 (Half-Galvanised)

144

-

-

... More
33KV, 400A, 3-ph, Gang switch (Rocking Type Air Break Isolator) along with support insulators operating mechanism, Base Channel down Pipe, terminal connectors and other accessories complete as per IS : 9921 (Pt. I to IV) or its latest amendment and TS Vol II - for 33/0.4KV Station Transformer

1

-

-

... More
Supply of discharge rod with clamp having screw type arrangment for fixing tightly on conductor(ASCR) for panther with boalt nut and saddle for earthwire. The operating rod fixed with clamp shall be made of telestone fiber glass tube suitable for 33/11 KV

2

-

-

... More
Control & Relay Panels

-

-

-

... More
3.5 Mtr length weighing 12.25 kg for disgonal member

1476

-

-

... More
Supply of 33 KV Termination Kit for 1 C X 400 mm sq. XLPE cable( for connecting 33kV Auto recloser to Power Transformer Primary and for Incomer 33KV feeder to Bus)

16

-

-

... More
50X6mm Copper Strip

20

-

-

... More
Structure for 33KV and 11KV bay

-

-

-

... More
11 KV CURRENT TRANSFORMER (METERING AND DIFF PROTECTION)

-

-

-

... More
LIGHTNING ARRESTOR

-

-

-

... More
11 KV VCB

-

-

-

... More
80mm dia GI pipe

100

-

-

... More
PVC insulated AL armoured Power 3.5C X 95 SQ.MM

25

-

-

... More
Supply of 11kv, single pole, single phase,outdoor type with ratio 600-300A/1-1A, 15 VA burden,PS class accuracy 0.5 Neutral CT for protection. The CTs will be complete with bimetallic terminal for connecting ACSR wires, whe

1

-

-

... More
50X6mm GI Strip

100

-

-

... More
11 KV ISOLATOR

-

-

-

... More
Copper Control Cables

-

-

-

... More
33 kV SF6 circuit breaker, 3-Ph (out-door type ) complete

2

-

-

... More
Pole Double Clamp of G.I flat 50x6 mm

90

-

-

... More
Supply of outdoor, single pole Potential transformer with voltage ratio(33/√3 kV)/(110V/√3), output 100 VA burden with class accuracy 0.5. The PT should be complete with bimetallic connectors for connecting it to overhead conductor , whether proof second

3

-

-

... More
POTENTIAL TRANSFORMER

-

-

-

... More
33kv, single pole, single phase,outdoor type with ratio 200-100A/1-1A, 15 VA burden, class accuracy 0.5 Transformer CT for metering and TRF differential protection complete with bimetallic terminals, weather proof secondary terminals, including all accessories.

3

-

-

... More
Supply of 11 KV 3C X185 sq. mm. XLPE Al. (For DT)

50

-

-

... More
LT XLPE Unarmoured Copper Power Cable of following sizes, 1.1KV

-

-

-

... More
Supply of 33kv, single pole, single phase,outdoor type with ratio 400-200A/1-1A, 15 VA burden, class accuracy 0.5 Line CT for metering , The CTs will be complete with bimetallic terminal for connecting ACSR wires, wheather proof

3

-

-

... More
Supply of Copper Plate Earthing for Transformer Neutral (600x600x3.15)

6

-

-

... More
MS Single Clamp 5.5" (140 mm) dia (middle)

360

-

-

... More
Earthing & Lightning Protection

-

-

-

... More
Supply of 33 KV 1 x C 400 sqmm XLPE Al.(for connecting Power Transformer Primary and from Incomer 33KV feeder to Bus)

150

-

-

... More
LIGHTNING ARRESTOR

-

-

-

... More
Supply of Earthing Strip

-

-

-

... More
Danger plate for 33 kv

60

-

-

... More
33KV VCB

-

-

-

... More
24V DCDB as per TS & the Electrical Layout

1

-

-

... More
11KV SIDE EQUIPMENT

-

-

-

... More
LT XLPE Armoured Aluminium Power Cable of following sizes, 1.1KV

-

-

-

... More
Supply of outdoor, single pole Potential transformer with voltage ratio(11/√3 kV)/ (110V/√3), output 100 VA burden with class accuracy 0.5. The PT should be complete with bimetallic connectors for connecting it to overhead conduct0r

3

-

-

... More
Down conductor for Lightining spike (25x3mm GI Strip)

150

-

-

... More
PVC insulated AL armoured Power 3.5C X 120 SQ.MM

25

-

-

... More
Isolator suitable for a system voltage of 33 KV, rated current of 400 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type, pole mounted suitable for horizontal mounting with EARTH SWITCH

1

-

-

... More
2.5 Mtr length weighing 8.75 kg for horizontal member

1056

-

-

... More
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Differential relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Transformers LV incomer Breakers

1

-

-

... More
50X10mm GI Strip

100

-

-

... More
Indoor Control and Relay Panel (consisting of OC/EF numeric relay, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, Master trip relay, Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram, static TVM etc. The C/R Panel should be supplied with mandatory/recommended spares such as Control Switches, indicating lamps, HRC fuses etc. - For Outfoing Feeders and Bus Coupler Breakers.

2

-

-

... More
PVC insulated AL armoured Power 3½ xC, 35 sqmm

25

-

-

... More
Transistorised Battery Charger Set with full wave rectification, 1-ph, 200/240V, 50Hz Input Voltage for charging 24V, 65AH Battery along with required cable, connectors etc. for conection with 24 V 64AH Battery Set & 220V AC Source and 24V DCDB

1

-

-

... More
GI Nuts & Bolts 5/8" x 3" (16x75 mm)

180

-

-

... More
Hardware fittings for B&S Disc Insulator, complete

396

-

-

... More
33 KV Control & Relay Panels

-

-

-

... More
PVC Insulated CU unarmoured Power cables1C x 70 SQ.MM.

80

-

-

... More
75X6mm GI Strip

100

-

-

... More
Supply of CT & PT Jnc Box (12 way)

10

-

-

... More
GI Nuts & Bolts with washer ( Assorted sizes including through bolt)

150

-

-

... More
Supply & fixing of 33 KV Pin/Post Insulators with Pin

1

-

-

... More
415 Volt LTAC Panel as per specification with 250A TPN MCCB as incomer ,2x 100A MCCB,2x32A TP ,5x16A TP, 4x16A DP,1x32A DP MCB.

1

-

-

... More
9kV, 10 kA single pole, class 2, station type, heavy duty, Lightning Arrestor complete with suitable bimetallic connectors for ACSR wire connections, parallel groove clamps, weather proof secondary terminals, with-out counter, including all accessories.

9

-

-

... More
Termination Kit

-

-

-

... More
MS Single Clamp 4.5" (115 mm) dia (top)

24

-

-

... More
Supply of 12 C X 2.5 mm sq.

300

-

-

... More
33 KV Drop Out fuse of rated current 100 A/ 200 A/400A, complete with fuse carrier assembly, fuse base & tube and mounting arrangement as per IS:9385 (Part-I to III) as amended from time to time and tech spec Vol-II. For 33/0.4 KVStation Transformer

1

-

-

... More
PVC insulated AL armoured Power 3½ x C, 70 sqmm

25

-

-

... More
33/0.433KV, 25 KVA, oil type Station transformer

1

-

-

... More
GI Washers 5/8" x 3" (18 mm dia for 16 mm bolts)

48

-

-

... More
Supply of 3.0 mtr 40mm dia GI Pipe Earthing

30

-

-

... More
MS Channel 100x50x6 mm for X-arm, 27.6 kg per channel

3974.4

-

-

... More
Supply of 5 C X 2.5 mm sq.

300

-

-

... More
Isolator (3-phase) suitable for a system voltage of 11 KV, rated current of 800 A and fault withstand of 16 KA for 1 sec and shall be manual operated, single break type, triple pole, outdoor type,pole mounted suitable for horizontal mounting WITH EARTH SWITCH (for Line)

3

-

-

... More
Supplying and Fixing Disc Insulators (Polymer) 70 KN BS type

1

-

-

... More
INCOMING

-

-

-

... More
Supply of 11 KV 1 x C 300 sqmm XLPE Al.(for Connecting Secondary of Power Transformer to 11KV Bus to Outgoing Feeder)

200

-

-

... More
Supply of 11 KV Termination Kit for 1 C X 630 mm sq. XLPE cable ( for Connecting Secondary of Power Transformer to 11kV Incomer Auto Reclosers and for Autorecloser to outgoing feeder - 4 outgoing 11KV Feeders).

15

-

-

... More
Lightining spike

15

-

-

... More
Supply & fixing of 11 KV Pin/Post insulators with Pin

1

-

-

... More
Supply of 11 KV Termination Kit for 1 C X 185 mm sq. XLPE cable ( for DTs etc).

5

-

-

... More
Supply of 11kv, single pole, single phase,outdoor type with ratio 500-400A/5-5A, 15 VA burden,PS class accuracy 0.5 Transformer CT for metering and differnetial protection. The CTs will be complete with bimetallic terminal for connecting ACSR wires, whe

3

-

-

... More
Guard Bracket

540

-

-

... More
PANTHER ACSR Conductor

200

-

-

... More
11 KV VCB 3-ph, with Indoor Panel consisting of Vacuum Circuit breaker, CT, PT, Voltmeter, Ammeter, MW Meter, KwH meter, pf Meter, Frequency Meter, indication lamp, Breaker Control Switch, OC/EF Relays (numerical) , Master trip relay (numerical), Annunciation Windows with Annunciation Relays, Push-Button for Alarm Accept/Reset/Lamp Test, Mimic Diagram etc. & other components as per Technical Specifications. The breaker should be supplied with mandatory/recommended spares such as VI, Trip Coil , indicating lamps etc. ABB/SCHNEIDER/CROMPTON/TOSHIBA Make

3

-

-

... More
GI M.S Angle 50x50x6x5000 mm each weighing 22.5 Kg (Galvanised)

225

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.