Assam Rifles Tender

... More
The Assam Rifles has issued a formal invitation for competitive bids for Repair Maint Of Roof, Hard Standing And Chequered Tiles Of Qg, Bldg No. Dsp801 A, B And C At Bn Hq Of 43 Assam Rifles. in Wokha, Nagaland. The bid opening date for this tender is 29-08-2023 and the last date for bid submission is 07-09-2023. Interested bidders for Assam Rifles tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.

Assam Rifles Tender

Opening Date29 Aug 2023
Closing Date7 Sep 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Repair Maint Of Roof, Hard Standing And Chequered Tiles Of Qg, Bldg No. Dsp801 A, B And C At Bn Hq Of 43 Assam Rifles.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repair maint of roof, Hard standing and Chequered tiles of QG, Bldg No. DSP801 A, B and C at Bn HQ of 43 Assam Rifles
Repair maint of roof, Hard standing and Chequered tiles of QG, Bldg No. DSP801 A, B and C at Bn HQ of 43 Assam Rifles
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).

3.68

-

-

... More
Dismantling roofing including ridges, hips, valleys and gutters etc. and stacking the material within 50 metres lead of G.S. Sheet.

11.52

-

-

... More
Providing and fixing tiled false ceiling of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm with GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

43.5

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

98.01

-

-

... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.

104

-

-

... More
Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand).

57.29

-

-

... More
SCHEDULE ‘A’ PART - I (Repair of Building)

-

-

-

... More
Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specificationon on Old work (one or more coats) .

1960.28

-

-

... More
Providing and laying ceramic floor tiles of size 300x300mm ( thickness to be specified by the manufacturer) of approved make, in all colours and shades except white, Ivory, Grey laid on 20mm thick CM 1:4 (1cement :4 coarse sand), incl grouting the joints with white cement and matching pigments. etc. complete.

4.48

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.