Public Works Department Tender
View complete overview of Mizoram PWD Tender
Costs
EMD
₹ 13,35,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Summary
Construction Of Rawlbuk To Lungtian Road
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MZPWD_90891_2Bid Award Id
ViewTender No
1/PMGSY/2020Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://pwd.mizoram.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Construction of earthen shoulder.
Construction of subgrade and earthen shoulder with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compavted to meet requirement of table 300.2 with lead upto 1000m as per technical specification clause 303.1.
6403.32
-
-
Earthwork in excavation for structures as per drawing and technical Specification Clause 305.1. including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and back filling in trenches with excavated suitable material.I. Ordinary soil (upto 3m depth)
420
-
-
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification clause 802, 803, 1202 & 1203.
I. PCC Grade M10.
Nominal Mix 1 : 3 : 6 (hand mixing).
10.8
-
-
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204.
II. Course rubble masonry (2nd sort).
(iii) in cement mortar 1 : 5.
164
-
-
Providing and laying filter media with granular crush aggregates as per specification to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind retaining wall to the full height compacted to firm condition complete as per drawing and technical specification clause 1204.3.8
91.2
-
-
Stone masonry in cement mortar 1:3 for parapet complete as per drawing and technical specifications Clauses 700 and 1208.4.
I. Random rubble masonry.
5.2
-
-
Plastering with cement mortar ( 1:4) 15mm thick on Brick/Stone works as per drawing and technical specification clauses 613.4 and 1204
50
-
-
Providing PCC M20 architectural coping on the top of retaining wall complete as per drawing and technical specification clause 615,710 and 1204.3.11.
10
-
-
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications clauses 702, 704, 1202 & 1203.
II. Coursed rubble masonry.
(ii) In 1 : 4 cement mortar.
186
-
-
Providing and laying parapet with pcc M15 as per drawing and technical specification clause 800 and 1208.4.
(i) Nominal mix 1:2.5:5(Hand Mixing)
270
-
-
Plastering with cement mortar (1:3) 15mm thick works as per drawing and technical specification clauses 613.4 and 1204
1404
-
-
Providing concrete for plain/reinforced concretein open foundation complete as per drawing and technical specification clause 802, 803, 1202 & 1203.
I. PCC grade M 10
Nominal Mix 1:3:6 (Hand Mixing)
4.15
-
-
Stone Masonry in cement mortar for substructure.
II Course rubble masonry (2nd Sort)
(i) in cement mortar 1:3.
24.2
-
-
Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC : 8 fixing in position including painting and printing, etc. as per drawing and Technical specification clause 1703.
i) 5th kilometre stone (precast)
3
-
-
Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC : 8 fixing in position including painting and printing, etc. as per drawing and Technical specification clause 1703.
ii) Ordinary kilometre stone (precast)
10
-
-
Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC : 8 fixing in position including painting and printing, etc. as per drawing and Technical specification clause 1703.
iii) 200m stone (precast)
46
-
-
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801.
(ii) 60cm equilateral Triangle
Speed limit
2
-
-
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801.
(ii) 60cm equilateral Triangle
Left Hand Curve
20
-
-
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801.
(ii) 60cm equilateral Triangle
Right Hand Curve
20
-
-
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801.
(ii) 60cm equilateral Triangle
Men at Work
2
-
-
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801.
(ii) 60cm equilateral Triangle
School
1
-
-
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801.
(ii) 60cm equilateral Triangle
Falling Rocks
2
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.
Destination Sign
1.62
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.
Place Identification Sign
0.75
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.
Advance Direction Sign
1.62
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.
Direction Sign
0.36
-
-
Providing and fixing as per Guidelines:
PMGSY Logo
7
-
-
Providing and fixing as per Guidelines:
Title Informatory Board
2
-
-
Providing and fixing as per Guidelines:
Citizen Informatory Board
1
-
-
AMC for 1st Year
14
-
-
AMC for 2nd Year
14
-
-
AMC for 3rd Year
14
-
-
AMC for 4th Year
14
-
-
AMC for 5th Year
14
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements