Manipur State Power Company Limited Tender
View complete overview of Manipur MSPDCL Tender
Manipur State Power Company Limited - MSPDCL Tender
Civil And Construction
Eprocure
Opening Date20 Nov 2018
Closing Date13 Dec 2018
Tender Amount₹ 15,27,47,000
Costs
EMD
₹ 10,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MSPDC_601_6Bid Award Id
ViewTender No
No.2/138(SAUBH-Turn Key)/2018-MSPDCL-TechTender Authority
Manipur State Power Company Limited ViewPurchaser Address
-Website
http://https://www.mspdcl.com
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Galvanised Clamp for Pole top Bracket
364
-
-
Galvanised Cross arm(75X40)mm
182
-
-
Galvanised Back clamp for X-arm
182
-
-
Galvanised 2.2m D.P. channel X-arm (75X40)mm
121
-
-
11 KV Disc. Composit/Polymer Insulator (Complete set i/c Tension clamps,Hardware)
727
-
-
11 KV Pin Composit/Polymer Insulator (Complete with Pin )
545
-
-
ACSR Conductor (Weasel)
95.45
-
-
11 KV AB Switch/G.O. Switch with Galvanised X-arm etc.
32
-
-
Stay Set complete with stay wire, base plate, stay rod etc.
455
-
-
Galvanised Stay Clamp
455
-
-
Galvanised Bracing for D.P.structure, 50X50X6mm M.S. Angle
121
-
-
Galvanised Clamp for D.P. Bracing
484
-
-
Galvanised Anti climbing device complete
424
-
-
Earthing set complete with G.I. wire
424
-
-
Guarding at crossing with G.I. wire
30.3
-
-
Nuts, Bolts, MS flat as support for item No. 3 jointing sleeves etc.@7.5Kg/km
227.25
-
-
Al. Binding wire, UPG clamps etc.
30.3
-
-
Sundries like pole painting Danger plate etc.
30.3
-
-
Installation of Distribution Transformer
-
-
-
Installation of New Distribution Transformer of 63 KVA (12 Nos)
-
-
-
9m Steel Tubular poles 410 SP-31
24
-
-
Galvanised Channel 100X50,@ 7.9 Kg/m 2.8X2 for supporting Transformer
12
-
-
Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm
12
-
-
Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2
12
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X2.8m for HG fuse unit & A.B. switch
24
-
-
Galvanised Clamp for transformer belting
24
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X0.5m for supporting H.G. fuse main channel X-arm
36
-
-
Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support.
12
-
-
Galvanised Clamp for transformer base channel for M.S. flat 50X8mm@3.1Kg/m 0.27mX2.
24
-
-
Galvanised Clamp for DB Box Cross arm
24
-
-
Galvanised Clamp for A.B. switch bracing 50X8mm @ 3.1Kg/m 0.23m X2 =0.46m.
96
-
-
Distribution transformer 63 KVA as per IS:1180(2014) level-II
12
-
-
A.B.Switch
12
-
-
Horn gap fuse unit/D.O. fuse, 3 -Ph
12
-
-
3 way D.B.box with complete accessories such as Cu. Bus-bar with Kit-Kat.
12
-
-
1.1KV grade, 3½ core 120 Sq.mm PVC insulated aluminium power cable
120
-
-
D.B.box Galvanised cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m
12
-
-
Sub-Station Earthing (set of 3 Earthing Pipe)
12
-
-
3 phase Tri-vector Energy meter comprising of IS 14697-1999 with Kiosk
12
-
-
Danger board.
12
-
-
11 KV lightening arrestor
36
-
-
Bolts,Nuts,clamps etc.@5kg/km
60
-
-
Sundries, Pole painting etc.
12
-
-
Installation of New Distribution Transformer of 25 KVA (20 Nos)
-
-
-
9m Steel Tubular poles 410 SP-31
40
-
-
Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for supporting Transformer
20
-
-
Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm
20
-
-
Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2
20
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X2.8m for HG fuse unit & A.B. switch
40
-
-
Galvanised Clamp for transformer belting
40
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X0.5m for supporting H.G. fuse main channel X-arm
60
-
-
Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support.
20
-
-
Galvanised Clamp for transformer base channel for M.S. flat 50X8mm@3.1Kg/m 0.27mX2.
40
-
-
Galvanised Clamp for DB Box Cross arm
40
-
-
Galvanised Clamp for A.B. switch bracing 50X8mm @ 3.1Kg/m 0.23m X2 =0.46m.
160
-
-
Distribution transformer 25 KVA as per IS:1180(2014) level-II
20
-
-
A.B.Switch
20
-
-
Horn gap fuse unit/D.O. fuse, 3 -Ph
20
-
-
3 way D.B.box with complete accessories such as Cu. Bus-bar with Kit-Kat.
20
-
-
1.1KV grade, 3½ core 95 Sq.mm PVC insulated aluminium power cable
200
-
-
D.B.box Galvanised cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m
20
-
-
Sub-Station Earthing (set of 3 Earthing Pipe)
20
-
-
3 phase Tri-vector Energy meter comprising of IS 14697-1999 with Kiosk
20
-
-
Danger board.
20
-
-
11 KV lightening arrestor
60
-
-
Bolts,Nuts,clamps etc.@5kg/km
100
-
-
Sundries, Pole painting etc.
20
-
-
Arial Bunched Cable
-
-
-
New LT Line Using 3 phase 4 wire with AB Cable (3x50+1x35)Sq.mm (86.38 Km.)
-
-
-
8.0 m S.T.P.(410:SP-14)
2160
-
-
M.S. cross arm (75X40) mm, 500 mm long
2160
-
-
Back clamp for cross arm
2160
-
-
Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
346
-
-
Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
1814
-
-
AB Cable (3x50+1x35)Sq.mm with insulated messenger/Neutral
86.38
-
-
Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)}
4319
-
-
Earthing set complete with G.I. wire.
691
-
-
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
1728
-
-
Stay set complete with stay wire and insulator clamp etc.
518
-
-
Bolts & Nuts with washer@7.5kg/km
647.85
-
-
Sundaries,Pole painting, Danger plate, Number Plate etc.
86.38
-
-
New LT Line Using 1 phase 2 wire with AB Cable (1X35+1x25)Sq.mm (59.65 Km.)
-
-
-
8.0 m S.T.P.(410:SP-14)
1312
-
-
M.S. cross arm (75X40) mm, 500 mm long
1312
-
-
Back clamp for cross arm
1312
-
-
Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
239
-
-
Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
1074
-
-
AB Cable (1x35+1x25)Sq.mm with insulated messenger/Neutral
59.65
-
-
Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)}
2983
-
-
Earthing set complete with G.I. wire.
358
-
-
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
1193
-
-
Stay set complete with stay wire and insulator clamp etc.
239
-
-
Bolts & Nuts with washer@7.5kg/km
447.38
-
-
Sundaries,Pole painting, Danger plate, Number Plate etc.
59.65
-
-