Shri Saibaba Sansthan Trust Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Shri Saibaba Sansthan Trust - SAI Tender
Civil And Construction
Eprocure
Opening Date19 Sep 2024
Closing Date3 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 35,000Document Cost
₹ 590Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SAI_1086607_1Bid Award Id
ViewTender No
SSST/Construction/2024/141 /Toilet Block And ParkingTender Authority
Shri Saibaba Sansthan Trust ViewPurchaser Address
-Website
http://https://meity.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
375
-
-
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.
2500
-
-
TOILET BLOCK CIVIL WORK
-
-
-
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
47.57
-
-
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.
16.65
-
-
Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying /pumping, compacting, roughening them if special finishis to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc.complete.With fine aggregate (Crushed sand VSI Grade)
7.24
-
-
Filling in plinth and floors with contractors material/brought from outside and pproved
by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc.
complete
41.9
-
-
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
8.38
-
-
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite / gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
3.4
-
-
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
12.38
-
-
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/
granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade
5.64
-
-
Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement
and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade
0.2
-
-
Providing and fixing in position TMT-FE-500 bar reinforcement ofv arious diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc.as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
1.2
-
-
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
4.5
-
-
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Completee
11.9
-
-
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6mm diameter / two hoop iron strips 25mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc.complete.
40.16
-
-
Inrernal Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. completeCement Plaster
81.07
-
-
Providing neeru finish to plastered surface sin all positions including scaffolding and curing etc. complete.
53.88
-
-
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using water proofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.
103.74
-
-
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement
plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly
cleaning oil, grease, dirt and other foreign matter and sand papering as required etc.
complete.
53.88
-
-
Providing and applying plastic emulsion paint of approved quality,colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete.
53.88
-
-
Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
25.02
-
-
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. NOTE: ForItem One Number 15 to 18 prior approval of Superintending Engineer will be necessary
103.74
-
-
Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S.65241983 having 6mm dia bars 3 Nos.And strips @ 250 mm c/c and fixing in wall with 6Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm
60.6
-
-
Providing and fixing 30mm thick SOLID PANEL PVC INTERNAL DOOR SHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for stiles, top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat molded PVC channel of size 30x100mm forming stiles, and 5mm thick, 125mm wide PVC sheets for top rail, lock rail and bottom rail on eitherside, and 15mm (5mmx3) thick, 20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 10mm thick prelam PVC sheet to be fitted in the M.S .frame welded /sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on eitherside, andjoined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20 mm width is to be stuck on the interior side of the C Channel using PVC solvent cement adhesive.including stainless steel fixture sand fastening Complete as per direction of Engineer incharge,manufacturer's specification and drawing.
17.56
-
-
Providing and fixing collapsible steel gate in one/ two leaves with hotrolledv ertical channels of 18 x9 x3 mm minimum size, crossings of M.S.flats of size18x5mm Tor Esection for runner of minimum 40x6mm siz for flange, M.S. flat for top runner of minimum size 40x12 mm with roller wheels confirming to grade F.G.150 fitted with snap headed rivets of minimum size 6mm max.spacing of vertical channels be100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with holdfasts,stoppers,spaces,handles,locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983).
7.74
-
-
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One
Square Metre as per drawing including fixtures, necessary welding and painting with
one coats of anticorrosive paint and two coats of oil painting complete.
3.78
-
-
Providing waterproofing in W.C. and bath including brickbat coba in all position including providing and laying 12 mm bedding in cement mortor1:3on verg in concrete slab with water proofing compound @ 1 Kilogram /per bag of cement laying brickbat coba of required thickness in cm 1:5 with water proofing compound 1Kilogram / bag of cement grouting and finishing the to player with 20 mm thick brick bedding in cm mortor1:3 with waterproofing compound 1 Kilogram / per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guaranteeon requisite stamp paper including curing etc. complete.
4.82
-
-
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete
44.53
-
-
Providing and laying vitrified matt finish tiles having size 590 mm to 605mm x to 605 mm of 8 to10mm thickness and confirming IS.15622-2006 (GroupBla) of approved make, shade and pattern forfloorig required position fixed in1:4cement mortar including neat cement float, filling joints,curing and cleaning etc.complete.
27.15
-
-
Providing and laying Antiskid Ceramic tiles of approved quality of size30cmx30 cm and confirming to IS15622-2006(Group-BIIA) for antiskid flooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete.
8.64
-
-
Providing and laying vitrified mirror/glossy finish tiles having size 590 mm to 605mm x 590 mm to 605 mm of 8 to10 mm thickness and confirming to IS.15622-2006 (groupBla) of approved make, shade and pattern for dado and skirting in required position fixed in1:4 cement mortar including neat cement float, filling joints,curing and clearing etc.complet
104.59
-
-
Providing and laying machine cut machine Polished Kota stone flooring 25 mm to 30 mm thick and required width in plain/ diamond pattern on bed of 1:6C.M.including cement float,filling joints with neat cement slurry,curing,polishing and cleaning etc.complete.
6.6
-
-
Providing and constructing Brick Masonry Inspection Chamber 60cmx 45cm x90cm including 1:4:8 cement concrete foundation1:2:4 cement concrete channels half round G.S.W.pipes,Brick Masonry,plastering from inside and airtight C.I.cover of 75 Kilogram with lid and frame fixed in cement concrete
4
-
-
Providing and fixing hume pipe septic tank 900 mm diameter with vent pipe and cap including necessary (including excavation and laying)
1
-
-
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet,outlet over flow of all tank scapacity above 1000 to 20,000 litres
2000
-
-
Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the out side face of the wall (1:5:10) cement concrete bedding 15mm thick,10liter P.V.C.flushing cistern with all necessary pipe connection etc. complete.
4
-
-
Providing and fixing European type wall-hung white watercloset of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe upto out side face of wall, 100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete.
4
-
-
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap,chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete.
4
-
-
Providing and fixing coloured glazed earthen ware full stall type Urinal with P.V.C .flushing cistern of 5liters capacity with fitting, inlet pipes and stop tap brackets for fixing the cistern 32mm dia.P.V.C.flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection up to the outside face of the wall.
4
-
-
Providing and fixing White Glazed Earthenware Squatting plate (LadiesUrinal) with P.V.C. flushing cistern of 5liters capacity with fitting,inlet pipes and stop tap, brackets for fixing the cistern, 32mm dia.P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap,soil pipe connection upto the out side face of the wall
4
-
-
Providing and fixing 10 cm PVC nahani trap with grating etc. complete.
6
-
-
Providing and fixing on walls / ceiling /floor15mm dia.CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
17
-
-
Providing and fixing on walls / ceiling /floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
14
-
-
Providing and fixing on walls / ceiling /floor 40mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete.Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
12
-
-
Providing and fixing 75 mm dia stabiliser pipe /P.V.C. soilvent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions,slotted vent,clamps etc.complete
4
-
-
Providing,laying and fixing P.V.C.pipe of 110mm.dia.with fittings such as bends, tees, reducers, clamps,etc.including necessary excavation, trench filling etc.complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
15
-
-
Providing and laying concrete pipes of I.S.NP.class of 225 mm diameter in proper line, level and slope including necessary collars, excavation,laying,fixing with collars in cement mortar 1:1 and refilling the trench complete.
50
-
-
Providing and fixing C.P.BIB cock with wall flange of approved make including necessary sockets / union nut etc. complete.
16
-
-
Providing and fixing screw down for 40 mm dia. Wheeled stop tap of brass including necessary sockets / union nut complete
2
-
-
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete. (weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec. One Number: As directed by Engineer- in-charge.
10.97
-
-
Electrical Work
-
-
-
Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW
42
-
-
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
10
-
-
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW. (For Earth Wire)
10
-
-
Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places.as per specification no. WG-MA/BW.
20
-
-
Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places.as per specification no. WG-MA/BW. (For Earth Wire)
20
-
-
Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW
10
-
-
Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW. (For Earth Wire)
10
-
-
Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD20%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED.
18
-
-
Supplying and erecting BulkHead LED fitting Max. 10W with high transitivity diffuser with system lumens output of Min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50, IP66, IK09 rated including driver IP66, IK09 rated on provided PVC Block / wooden board with minimum 2 years warranty as per specification No. FG-IDF/LED.
12
-
-
Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC.
20
-
-
Supplying and erecting PVC insulated PVC round sheathed FR 1.5 sq.mm (30 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV
112
-
-
Supplying and erecting integrated LED street light fitting 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K,THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/SL.
16
-
-
Supplying, erecting & marking FP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
16
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
550
-
-
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
50
-
-
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete.
500
-
-
Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
16
-
-
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT
16
-
-
Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole).
16
-
-
Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP
16
-
-
Supply, installing, and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with Carbon based environment friendly back fill ground enhancing compound required to fill up the
1
-
-
Supplying and erecting annealed bare copper earth conductor of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.
2
-
-
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB.
4
-
-
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements