Public Works Department Tender

... More
The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Construction Of Taluka Court Building At Dhadgaon Dist.nandurbar (3 Courts) in Nandurbar, Maharashtra, with an estimated contract value of Rs. 16,83,46,795. The bid opening date for this tender is 08-05-2025 and the last date for bid submission is 14-05-2025. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date8 May 2025
Closing Date14 May 2025
Tender Amount₹ 16,83,46,795 
Notes
Download

Costs

  • EMD

    ₹ 8,38,000
  • Document Cost

    ₹ 3,540
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0 mtere.)

36.99

1

36.99

... More
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 metre to 3.0 metre)

186.91

1

186.91

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5metre To 3.0 metre)

186.91

1

186.91

... More
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0 mtere.)

373.78

1

373.78

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite / quartzite / gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

178.99

1

178.99

... More
Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)

207.08

1

207.08

... More
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263

431.27

1

431.27

... More
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.

353.28

1

353.28

... More
Providing and laying in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)

36

1

36

... More
Providing and laying in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)

1052.84

1

1052.84

... More
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)

16.27

1

16.27

... More
Providing and laying Cast in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor

179.3

1

179.3

... More
(B) First Floor

126.16

1

126.16

... More
(C) Second Floor

126.16

1

126.16

... More
(D) Third Floor

163.61

1

163.61

... More
Providing and casting in situ cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade

10.9

1

10.9

... More
Providing and casting in situ cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor

249.37

1

249.37

... More
(B) First Floor

114.57

1

114.57

... More
(C) Second Floor

114.64

1

114.64

... More
(D) Third Floor

106.14

1

106.14

... More
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor

1.98

1

1.98

... More
(B) First Floor

4.05

1

4.05

... More
(C) Second Floor

3.87

1

3.87

... More
(D) Third Floor

4.3

1

4.3

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade )

8.45

1

8.45

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor

155.77

1

155.77

... More
(B) First Floor

158.21

1

158.21

... More
(C) Second Floor

158.21

1

158.21

... More
(D) Third Floor

162.44

1

162.44

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft Impactor Grade)

16.69

1

16.69

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor

21.01

1

21.01

... More
(B) First Floor

14.02

1

14.02

... More
(C) Second Floor

14.13

1

14.13

... More
(D) Third Floor

14.13

1

14.13

... More
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor

8.24

1

8.24

... More
(B) First Floor

8.78

1

8.78

... More
(C) Second Floor

10.36

1

10.36

... More
(D) Third Floor

10.28

1

10.28

... More
Providing and fixing during laying in Reinforced Cement concrete Slab rectangular 2 millimetre thick Mild Steel sheet fan hook box of size 180 X 100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface (A) Ground Floor

26

1

26

... More
(B) First Floor

32

1

32

... More
(C) Second Floor

35

1

35

... More
(D) Third Floor

21

1

21

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor

6.98

1

6.98

... More
(D) Third Floor

6.16

1

6.16

... More
Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (A) Ground Floor

167.36

1

167.36

... More
(B) First Floor

45.35

1

45.35

... More
(C) Second Floor

45.56

1

45.56

... More
(D) Third Floor

49.9

1

49.9

... More
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (A) Ground Floor

1.2

1

1

... More
(B) First Floor

1.18

1

1

... More
(C) Second Floor

0.7

1

0.7

... More
(D) Third Floor

2.83

1

2.83

... More
Providing expansion joints in Reinforced Cement Concrete framed structure (interior column) with plain premoulded filler 25 millimeter thick including fixing Teak Wood battens on both faces and finishing as directed etc. Complete.

93.9

1

93.9

... More
Providing expansion joints in Reinforced Cement Concrete framed structure (exterior Columns) with plain premoulded filler 25 millimetre thick and 3 millimetre thick alluminium plate, hold fast, fixing Teak Wood battens on internal face, finishing etc. complete as directed.

33.71

1

33.71

... More
Providing expansion joints in Reinforced Cement Concrete framed structure (at floor level) with premoulded filler 25 millimeter thick and 3 millimeter thick aluminium plate as required, bitumen poured filler and fixing Teak Wood battens on rear faces etc. complete as directed.

11.52

1

11.52

... More
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.

24.68

1

24.68

... More
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225) millimetre in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete (A) Ground Floor

181.85

1

181.85

... More
(B) First Floor

389.41

1

389.41

... More
(C) Second Floor

372.39

1

372.39

... More
(D) Third Floor

402.26

1

402.26

... More
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100) millimetre in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out joints and watering compete (A) Ground Floor

69.14

1

69.14

... More
(B) First Floor

206.08

1

206.08

... More
(C) Second Floor

192.64

1

192.64

... More
(D) Third Floor

189.07

1

189.07

... More
Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete

62.6

1

62.6

... More
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. (A) Ground Floor

1631.56

1

1631.56

... More
(B) First Floor

3482

1

3482

... More
(C) Second Floor

3404.81

1

3404.81

... More
(D) Third Floor

3748.72

1

3748.72

... More
Providing waterproof plaster in Water Closet and bath 12 millimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kilogram per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge) (A) Ground Floor

308.42

1

308.42

... More
(B) First Floor

371.03

1

371.03

... More
(C) Second Floor

363.26

1

363.26

... More
(D) Third Floor

293.83

1

293.83

... More
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.

21.31

1

21.31

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (A) Ground Floor

3048.46

1

3048.46

... More
(B) First Floor

4685.01

1

4685.01

... More
(C) Second Floor

4620.67

1

4620.67

... More
(D) Third Floor

5016.01

1

5016.01

... More
Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete (A) Ground Floor

167.62

1

167.62

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (A) Ground Floor

1512.61

1

1512.61

... More
(B) First Floor

616.85

1

616.85

... More
(C) Second Floor

615.88

1

615.88

... More
(D) Third Floor

1050.47

1

1050.47

... More
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (A) Ground Floor

522.3

1

522.3

... More
(B) First Floor

411.24

1

411.24

... More
(C) Second Floor

410.59

1

410.59

... More
(D) Third Floor

700.32

1

700.32

... More
Providing and applying Texture plaster with finishing with Purlina / Rustic texture material ( with texture material of Asian / Renava / Nitco / Temtex or equivalent company make ) in 3 to 4 millimeter thickness on previously finished plastered surface including Plaster Groove 6 millimeter thickness or Tape Grooves 35 to 45 millimeter thickness or as required, in all position including preparing the surface scaffolding etc.complete. (A) Ground Floor

522.3

1

522.3

... More
(B) First Floor

411.24

1

411.24

... More
(C) Second Floor

410.59

1

410.59

... More
(D) Third Floor

700.32

1

700.32

... More
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete. (A) Ground Floor

167.62

1

167.62

... More
Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete. (A) Ground Floor

310

1

310

... More
(D) Third Floor

205.16

1

205.16

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete.

4557.95

1

4557.95

... More
Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.

5058.56

1

5058.56

... More
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete. (A) Ground Floor

333.89

1

333.89

... More
(B) First Floor

294.65

1

294.65

... More
(C) Second Floor

289.64

1

289.64

... More
(D) Third Floor

289.64

1

289.64

... More
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring (A) Ground Floor

183.21

1

183.21

... More
(B) First Floor

417.55

1

417.55

... More
(C) Second Floor

426.74

1

426.74

... More
(D) Third Floor

466.25

1

466.25

... More
Providing and laying vitrified matt fininsh tiles having size 900 mm x 900mm of 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring (B) First Floor

85.84

1

85.84

... More
(C) Second Floor

100.19

1

100.19

... More
(D) Third Floor

100.19

1

100.19

... More
Providing and laying chequered tiles of approved quality of size 30 centimetre x 30 centimetre for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.

189.69

1

189.69

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and confirming to Indian Standard 15622-2006 (Group-B HA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (A) Ground Floor

52.62

1

52.62

... More
(B) First Floor

58.71

1

58.71

... More
(C) Second Floor

66.58

1

66.58

... More
(D) Third Floor

66.02

1

66.02

... More
Providing and laying in situ cement concrete M30 with tremix treatment for 200 millimetre thickness for flooring with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen etc. complete. (A) Ground Floor

527.91

1

527.91

... More
Providing and laying vitrified matt finish tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting (A) Ground Floor

19.06

1

19.06

... More
(B) First Floor

38.52

1

38.52

... More
(C) Second Floor

34.79

1

34.79

... More
(D) Third Floor

36.54

1

36.54

... More
Providing and laying vitrified matt finish tiles having size 900 mm x 900 mm of 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting (B) First Floor

4.64

1

4.64

... More
(C) Second Floor

4.04

1

4.04

... More
(D) Third Floor

4.04

1

4.04

... More
Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre confirming to corresponding India Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. (A) Ground Floor

273.51

1

273.51

... More
(B) First Floor

336.79

1

336.79

... More
(C) Second Floor

317.02

1

317.02

... More
(D) Third Floor

320.53

1

320.53

... More
Providing and laying Polished Tandur Stone flooring 25 millimetre to 30 millimetre thick required width in plain/ diamond pattern on a bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. (A) Ground Floor

95.54

1

95.54

... More
Providing sills of required material 20 millimetre to 25 millimetre thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete, b) Granite (A) Ground Floor

2.98

1

2.98

... More
(B) First Floor

3.12

1

3.12

... More
(C) Second Floor

4.13

1

4.13

... More
(D) Third Floor

4.13

1

4.13

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. (A) Ground Floor

103.59

1

103.59

... More
(B) First Floor

166.62

1

166.62

... More
(C) Second Floor

164.94

1

164.94

... More
(D) Third Floor

160.77

1

160.77

... More
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (A) Ground Floor

72.51

1

72.51

... More
(B) First Floor

51.61

1

51.61

... More
(C) Second Floor

65.52

1

65.52

... More
(D) Third Floor

65.08

1

65.08

... More
Providing & fixing in position Stage flooring Made from 18millimetre plywood 1200 x 2400 & 18millimtre Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600millimetre centre to centre on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects. .including all materials labour,finishing etc complete (B) First Floor

26.85

1

26.85

... More
(C) Second Floor

26.85

1

26.85

... More
(D) Third Floor

26.85

1

26.85

... More
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (A) Ground Floor

3069.77

1

3069.77

... More
(B) First Floor

4685.01

1

4685.01

... More
(C) Second Floor

4620.67

1

4620.67

... More
(D) Third Floor

5016.01

1

5016.01

... More
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface, (excluding the primer coat)etc. complete. (A) Ground Floor

3044.46

1

3044.46

... More
(B) First Floor

4685.01

1

4685.01

... More
(C) Second Floor

4620.67

1

4620.67

... More
(D) Third Floor

5016.01

1

5016.01

... More
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface, (excluding the primer coat)etc. complete.

25.31

1

25.31

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kilogram per 15 Litre). plaster crack should be filled by Acrylic base Crack seal / Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. (A) Ground Floor

783.45

1

783.45

... More
(B) First Floor

616.85

1

616.85

... More
(C) Second Floor

615.88

1

615.88

... More
(D) Third Floor

1050.47

1

1050.47

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete.

729.16

1

729.16

... More
Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. (A) Ground Floor

522.3

1

522.3

... More
(B) First Floor

411.24

1

411.24

... More
(C) Second Floor

410.59

1

410.59

... More
(D) Third Floor

700.32

1

700.32

... More
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. (A) Ground Floor

22.5

1

22.5

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre X 40 millimetre X 5 millimetre with oil painting, etc. complete (A) Ground Floor

0.58

1

0.58

... More
(B) First Floor

0.96

1

0.96

... More
(C) Second Floor

1.01

1

1

... More
(D) Third Floor

0.93

1

0.93

... More
Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 millimetre thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 kilogram per Squaremetre is considered. (A) Ground Floor

5.4

1

5.4

... More
(B) First Floor

22.68

1

22.68

... More
(C) Second Floor

27

1

27

... More
(D) Third Floor

24.84

1

24.84

... More
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 millimetre thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 millimetre thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete. (A) Ground Floor

8.41

1

8.41

... More
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to Indian Standard 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre. (A) Ground Floor

5.1

1

5.1

... More
(D) Third Floor

34.2

1

34.2

... More
Providing and fixing solid core flush door shutter in double leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (B) First Floor

3.6

1

3.6

... More
(C) Second Floor

3.6

1

3.6

... More
(D) Third Floor

3.6

1

3.6

... More
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (A) Ground Floor

34.85

1

34.85

... More
(B) First Floor

68.37

1

68.37

... More
(C) Second Floor

65.58

1

65.58

... More
(D) Third Floor

67.59

1

67.59

... More
Providing and fixing mild Steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc. (A) Ground Floor

9

1

9

... More
Providing and fixing fiber glass reinforced polyster door shutter 35 millimetre thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. (A) Ground Floor

20.37

1

20.37

... More
(B) First Floor

13.44

1

13.44

... More
(C) Second Floor

26.88

1

26.88

... More
(D) Third Floor

28.56

1

28.56

... More
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 millimetre minimum size, crossings of Mild Steel flats of size 18 x 5 millimetre T or E section for runner of minimum 40 x 6 millimetre size for flange, Mild Steel flat for top runner of minimum size 40 x 12 millimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 millimetre max. spacing of vertical channels be 100 millimetre enclosed gate position and clear space of 150 millimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (Indian Standard 10521-1983). (A) Ground Floor

6

1

6

... More
(D) Third Floor

3.6

1

3.6

... More
Providing and fixing Indian Standard Institute marked double swing flush door shutters conforming to Indian Standard :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimetre thick including Indian Standard Institute marked Stainless Steel L- hinges with necessary screws Fittings and Fixtures per leaf Stainless steel kick plates on both sides of the door of 300 millimetre height Heavy Duty satin finish butt Stainless Steel Hinges (100 millimetre x 75 millimetre x 3 millimetre in size) - 4 numbers Stailess Steel finished lever handle with mortise lock- 1 no. Floor spring- 1 Number 100 millimetre x 100 millimetre safety glass at the specified location (A) Ground Floor

1.89

1

1.89

... More
(B) First Floor

1.89

1

1.89

... More
(C) Second Floor

1.89

1

1.89

... More
(D) Third Floor

1.89

1

1.89

... More
Providing and fixing Strong Room Door of specified size of GODREJ Make with Grill Gate, Godrej Air Ventilator (Heavy Duty), Godrej Air Exhaust Fan and Godrej V-Cage (Fan Cover) including conveying, loading, unloading etc. complete. (D) Third Floor

1

1

1

... More
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 X 38.10 X 0.90 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 X 31.75 X 1.30 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 X 31.75 X 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 X 18 X 1.10 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box (A) Ground Floor

48.6

1

48.6

... More
(B) First Floor

81

1

81

... More
(C) Second Floor

77.4

1

77.4

... More
(D) Third Floor

77.4

1

77.4

... More
Providing, supplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 millimetre thick Alluminium Composite Panel sheet material consisting of 3 millimetre thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 millimetre thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based olyvinylidene Flouride/Lumiflon based fluropolymer resin (having 70:30 ratio of Polyvinylidene Flouride and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the Alluminium Composite Panel shall not be less than 7.5 Killogram per Square Metre)

70

1

70

... More
Providing and fixing in position anodised (as per IS 1868/1982) Aluminium fixed staggered ( Z Type )Ventilator with aluminium rectangular pipe 63 mm x 38.10 mm x 1.22 mm at weight 0.650 Kg/Rmt, Aluminium angle of size 15 mm x 15 mm x 1 mm,aluminium channel of 9 mm sizes, S.S.mosquito net of 304 Grade,4 mm thick float glass per detailed drawing and as directed by Engineer in charge etc.complete. (A) Ground Floor

8.64

1

8.64

... More
(B) First Floor

12.96

1

12.96

... More
(C) Second Floor

9.72

1

9.72

... More
(D) Third Floor

10.8

1

10.8

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. (A) Ground Floor

12.24

1

12.24

... More
(B) First Floor

15.84

1

15.84

... More
(C) Second Floor

15.84

1

15.84

... More
(D) Third Floor

15.84

1

15.84

... More
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kilogram per square meter as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. (A) Ground Floor

78.38

1

78.38

... More
(B) First Floor

135.98

1

135.98

... More
(C) Second Floor

133.46

1

133.46

... More
(D) Third Floor

132.38

1

132.38

... More
Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 millimetre thick with 3 millimetre diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete.

0.54

1

0.54

... More
Providing & Fixing in position, Acoustical Panelling made from Gypsum plain 12 millimetre panels on, 50 x 50 millimetre Sal-wood frame of 600 x 600 centre to centre having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 millimetre thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete (B) First Floor

121.17

1

121.17

... More
(C) Second Floor

121.17

1

121.17

... More
(D) Third Floor

121.17

1

121.17

... More
PRIVIDING AND FIXING ACOUSTICAL FALSE CEILING WITH 0.7 NRC: Sierra Mineral Fibre Acoustical Suspended Ceiling System with 13mm thick Microlook Edge Tiles with 15mm face exposed grid. The tiles shall have smooth laminated salt pepper visual with Humidity Resistance (RH) of 95%, NRC 0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 28db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity λ = 0.037W/mK, Colour Global White, Fire Performance of class A2-s1, d0 according to EN 13501-1 with 13mm Microlook edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable. The tiles shall be classified as ISO 14644-1 cleanroom class 5. It shall be suitable for Green Building application, with Recycled content of 60%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between ―cross tee to cross tee and―cross tee to main beam‖. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications above) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners). (B) First Floor

100.19

1

100.19

... More
(C) Second Floor

100.19

1

100.19

... More
(D) Third Floor

100.19

1

100.19

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards, screwed / fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. (B) First Floor

46.69

1

46.69

... More
(C) Second Floor

46.69

1

46.69

... More
(D) Third Floor

46.69

1

46.69

... More
Providing and fixing bituminous pad 25 millimetre thick for expansion joints in retaining wall, compound wall etc. complete. (A) Ground Floor

10.53

1

10.53

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (A) Ground Floor

8.35

1

8.35

... More
Providing and fixing black kadappa stone shelves 25 millimetre thick machine polished, extending the polish upto 20 centimeter width on lowerside, rounding comers, laying in position jointing with bedding cement mortar 1:4 proportion curing etc complete. (A) Ground Floor

16.3

1

16.3

... More
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.

5748.66

1

5748.66

... More
Providing antitermite treatment around the periphery of the existing building as per Indian Standard 6313 (Part-Hi) by excavating trenches of 20 centimeter width and exposing the sides of columns and plinth beams upto a depth of 300 millimetre and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per Rmt and refilling the trenches etc. complete covering 2 years guarantee on bond paper.

162.88

1

162.88

... More
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO )

1081.97

1

1081.97

... More
Providing and Fixing Witness Box of size 1.20 Meter X 1.20 Meter, height 1.00 Meter. Top Hand Rail should be of Country Cut Teak Wood of Section 100 millimeter X 80 millimeter and decorative carved Baluster of section 80 millimeter X 80 millimeter as per detailed drawings, including french polishing, or as directed by the Engineer etc. complete.x (B) First Floor

2

1

2

... More
(C) Second Floor

2

1

2

... More
(D) Third Floor

2

1

2

... More
Providing and fixing Galvainsed Iron Pre coated trapezoidal Metallic coloured sheets of 0.50 millimetre thickness (26 Birmingham Wire Guage) of approved make for roofing without wind ties including fastening with galvanised iron screws and bolts and lead and bitumen washers as per drawing complete. Specification – As directed by Engineer-in-charge. (D) Third Floor

174.63

1

174.63

... More
Providing and fixing sky light in Reinforced Cement Concrete roof including frame made of Mild Steel angle 50 x 50 x 6 millimetre with hold fast, sheet glass 12 millimetre thick, Chicken mesh 24 gauge with all accessories and required fixtures and fastening fitting including painting etc. complete. (D) Third Floor

91.54

1

91.54

... More
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diametre and vertical pipe of 38 millimetre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use) (A) Ground Floor

37.29

1

37.29

... More
(B) First Floor

21.47

1

21.47

... More
(C) Second Floor

24.42

1

24.42

... More
(D) Third Floor

24.42

1

24.42

... More
Providing and fixing 900 millimetre high Stainless Steel 304 Grade Stainless steel railing with 40 millimetre diameter and 1.5 millimetre thick at top, 40 millimetre diameter and 1.5 millimetre thick vertical supports spaced at 1.5 metre center to center and 8 millimetre thick toughened glass including fabricating ,fixtures, errecting, necessary welding , grinding, finishing, buffing to stainless steel pipe etc. complete. (A) Ground Floor

23.93

1

23.93

... More
(B) First Floor

32.08

1

32.08

... More
(C) Second Floor

23.93

1

23.93

... More
(D) Third Floor

23.93

1

23.93

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre X 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rupees 500/- including ponding test etc. complete. (D) Third Floor

1082.9

1

1082.9

... More
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogram per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. (B) First Floor

18.1

1

18.1

... More
(C) Second Floor

18.1

1

18.1

... More
(D) Third Floor

17.94

1

17.94

... More
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 millimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 millimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 millimetre s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) (A) Ground Floor

11.12

1

11.12

... More
Providing & Fixing 12mm thick Toughned Glass Partition with rubber Gasket inlcluding fixtures & fastening etc. complete (B) First Floor

17.64

1

17.64

... More
Providing and laying in trenches 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

50

1

50

... More
Providing and laying in trenches 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

50

1

50

... More
Providing and laying in trenches 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

50

1

50

... More
Providing and laying in trenches 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

50

1

50

... More
Providing and laying in trenches 40millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

90

1

90

... More
Providing and fixing on walls/ceiling/floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor

80

1

80

... More
(B) First Floor

80

1

80

... More
(C) Second Floor

80

1

80

... More
(D) Third Floor

80

1

80

... More
Providing and fixing on walls/ceiling/floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor

80

1

80

... More
(B) First Floor

80

1

80

... More
(C) Second Floor

80

1

80

... More
(D) Third Floor

80

1

80

... More
Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor

80

1

80

... More
(B) First Floor

80

1

80

... More
(C) Second Floor

80

1

80

... More
(D) Third Floor

80

1

80

... More
Providing and fixing on walls/ceiling/floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor

80

1

80

... More
(B) First Floor

80

1

80

... More
(C) Second Floor

80

1

80

... More
(D) Third Floor

80

1

80

... More
Providing and fixing on walls/ceiling/floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor

80

1

80

... More
(B) First Floor

80

1

80

... More
(C) Second Floor

80

1

80

... More
(D) Third Floor

80

1

80

... More
Providing and fixing on walls/ ceiling/ floors, 80 millimetre diametreheavy grade having embossed as Indian Standard Instiute Mark galvanised iron pipes weight of 10.15 Kilogram per meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

4

1

4

... More
Providing and fixing on walls/ ceiling/ floors, 100 millimetre diametreheavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes weight of 14.74 Kilogram per meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

4

1

4

... More
Providing and making ISI Mark ferrule connection of 40mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.

1

1

1

... More
Providing, laying and fixing Poly Vinyl Chloride pipe of 110 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor

100

1

100

... More
(B) First Floor

100

1

100

... More
(C) Second Floor

100

1

100

... More
(D) Third Floor

100

1

100

... More
Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on CEment Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) (A) Ground Floor

43.5

1

43.5

... More
(B) First Floor

42

1

42

... More
(C) Second Floor

42

1

42

... More
(D) Third Floor

42

1

42

... More
Providing, laying and fixing Poly Vinyl Chloride pipe of 75 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor

100

1

100

... More
(B) First Floor

100

1

100

... More
(C) Second Floor

100

1

100

... More
(D) Third Floor

100

1

100

... More
Providing and fixing Chromium Plated 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Ground Floor

7

1

7

... More
(B) First Floor

8

1

8

... More
(C) Second Floor

8

1

8

... More
(D) Third Floor

8

1

8

... More
Providing and fixing Chromium Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Ground Floor

5

1

5

... More
(B) First Floor

9

1

9

... More
(C) Second Floor

9

1

9

... More
(D) Third Floor

9

1

9

... More
Providing and fixing screw down for 20 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. (A) Ground Floor

6

1

6

... More
(B) First Floor

6

1

6

... More
(C) Second Floor

6

1

6

... More
(D) Third Floor

6

1

6

... More
Providing and fixing 10 centimetre Poly Venyl Chloride nahani trap with grating etc. complete. (A) Ground Floor

15

1

15

... More
(B) First Floor

12

1

12

... More
(C) Second Floor

12

1

12

... More
(D) Third Floor

12

1

12

... More
Providing and fixing 25millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].

1

1

1

... More
Providing and fixing 1st class white glazed earthenware Orissa Type Water Closet Pan 580 millimetre diametre including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter Poly Vinyl Chloride flushing cistern with all necessary pipe connection etc. complete. (A) Ground Floor

5

1

5

... More
(B) First Floor

9

1

9

... More
(C) Second Floor

9

1

9

... More
(D) Third Floor

9

1

9

... More
Providing and fixing Wall Mounted European type white glazed earthenware water closet pan with Unplasticized Poly Vinol Chloride seat and lid with chromium plated brass hinges and rubber buffers including Unplasticized Poly Vinol Chloride and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 millimetre diametre Unplasticized Poly Vinol Chloride flush pipe with fittings and clamps, 20 millimetre diametre Unplasticized Poly Vinol Chloride overflow pipe ,mosquito proof couplings Galvanised Iron chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (A) Ground Floor

7

1

7

... More
(B) First Floor

8

1

8

... More
(C) Second Floor

8

1

8

... More
(D) Third Floor

8

1

8

... More
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32millimetre diameter Poly Vinyl chloride flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. (A) Ground Floor

2

1

2

... More
(B) First Floor

2

1

2

... More
(C) Second Floor

2

1

2

... More
(D) Third Floor

2

1

2

... More
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one no Stainless Steel 304 hinged rail 76 centimetre and three no Stainless Steel 304 of (Grab Bar) 60 centimetre all including cutting and making good the walls and floors wherever required ,seat cover, cistern and wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. (A) Ground Floor

1

1

1

... More
(B) First Floor

1

1

1

... More
(C) Second Floor

1

1

1

... More
(D) Third Floor

1

1

1

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 millimetre size with pillar cock, Chromium Plated Angular stop cock, long thread of approved make continental including Stainless Steel bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 millimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. (A) Ground Floor

10

1

10

... More
(B) First Floor

10

1

10

... More
(C) Second Floor

10

1

10

... More
(D) Third Floor

10

1

10

... More
Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete. (A) Ground Floor

10

1

10

... More
(B) First Floor

10

1

10

... More
(C) Second Floor

10

1

10

... More
(D) Third Floor

10

1

10

... More
Providing and fixing 450 millimetre X 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etc. complete. (A) Ground Floor

10

1

10

... More
(B) First Floor

10

1

10

... More
(C) Second Floor

10

1

10

... More
(D) Third Floor

10

1

10

... More
Providing and laying for 150 millimetre diametre salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.

100

1

100

... More
Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.

10

1

10

... More
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with Reinforced Cement Concrete Cover.

3

1

3

... More
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover.

5

1

5

... More
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges etc. complete . Both side polish (A) Ground Floor

1.8

1

1.8

... More
(B) First Floor

1.8

1

1.8

... More
(C) Second Floor

1.8

1

1.8

... More
(D) Third Floor

1.8

1

1.8

... More
Providing and fixing H.D.P container Sintex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (B) First Floor

8000

1

8000

... More
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick-bats.

2

1

2

... More
Providing and fixing Chromium Plated sink cock with raised J" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete." (A) Ground Floor

3

1

3

... More
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 millimeter thickness of having a strength of 400 Kilogram per Squaremetre of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including skirting joints and cleaning etc. complete. (using 100 percentage crushed sand)

100

1

100

... More
Providing and laying concrete pipes of Indian standard NP. class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.

80

1

80

... More
Providing , laying and fixing ,jointing Supreme Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.

80

1

80

... More
Providing and fixing reinforced cement concrete cover of size 90 centimetre X 45 centimetre with frame over inspection chamber etc. complete. Heavy duty (225 kilogram)

3

1

3

... More
Providing and fixing 90 centimetre X 60 centimetre Granite plate engraving 10cm. height letter, figures including painting the lefters / figures with approved colour and shade complete.

2

1

2

... More
Providing and fixing 45 centimetre wide mild steel ladder of 40millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diamtre mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder complete. (Anti Corossive Paint)

9

1

9

... More
Providing and fixing in position Unplasticized Poly Vinol Chloride ultra violet stabilized 110 millimetre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etc. complete (D) Third Floor

10

1

10

... More
Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter dia. 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.

1

1

1

... More
Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthing pits is not considered in this item

80

1

80

... More
Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 metre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on Mild Steel angle of size 35 x 35 x 3 millimetre frame with properly cross braced Mild Steel angles of size 35 millimetre x 35 millimetre x 3 millimetre duly painted including Two Mild Steel angle iron posts of size 65 millimetre x 65 millimetre x 6 millimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 centimetre x 60 centimetre x 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge

2

1

2

... More
Conveying unused materials obtained from excavation including all lifts and lead of over 1 Kilometre from the site of excavation to the site of deposition as directed.

841.06

1

841.06

... More
Providing and fixing mild steel grill gate with angle iron frame 65 millimetre x 65 millimetre x 10 millimetre with iron bars at 150 millimetre Center to Centre and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram per Squaremetre.

31.32

1

31.32

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.

188.33

1

188.33

... More
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.

18.6

1

18.6

... More
Spreading hard murum/ soft murum/ gravel or kankar for side width complete

18.6

1

18.6

... More
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.

186

1

186

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Intelligent Compactor with compaction analyzer and V-Sat attachment. to the required density. Grading I (Using Screening Type A (13.2) millimetre Aggregate)

94.16

1

94.16

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Intelligent Compactor with compaction analyzer and V-Sat attachment. to the required density. Grading II (Using Screening Type B (11.2 milimetre) Aggregate)

43.59

1

43.59

... More
Providing and constructing 75 millimetre thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 millimetre stone metal layers 100 percent crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 2 Kilogram per Square metre, spreading 12 millimetre size chips compacting with three wheel static roller having weight 8 to 10 Metric Tonne to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing Water Bound Macadam surface. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)

581.25

1

581.25

... More
Providing and applying tack coat on the prepared surface heating by flames in Boiler and spraying bitumen with sprayer on Granular surface treated with primer @ 2.75 kilogram per /10 Square Meter with Viscosity Grade-30 bulk Bitumen

581.25

1

581.25

... More
Open Graded Premix Surfacing- Providing and Laying Open Graded Carpet 20 millimetre thickness composed of 13.2 millimetre to 5.6 millimetre aggregates premixed with bituminous binder transported to site with Vessel Traffic Services , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with Supervisory Control and Data Acquisition, Paver and Vibratory roller ( Over MPM Surface) (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)

581.25

1

581.25

... More
Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of Viscosity Grade-30 grade preparing existing road surface, heating and applying bitumen @ 0.98 Kilogram per Square Metre. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 Metric TonneT. etc. complete.

852.5

1

852.5

... More
Executive's Table @ 1800 Length X 900 Depth X 750 Height : Providing & Fixing of Table @ 1800 Length X 900 Depth X 750 Height - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 millimetre thick Prelaminated particle board with Poly Vinyl chloride edge band as per drawing.

6

1

6

... More
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)

43.2

1

43.2

... More
Free Standing Table @ 1500Lx600Dx750HT : Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board

72

1

72

... More
Conference Table @ 3600Lx1400Dx750HT : Providing & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18millimetre Thick MDF top with Poly vinyl chloride Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4millimetre thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in Poly vinyl chloride Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 millimetre thick Prelaminated particle board with Poly vinyl chloride edge band. Access Flap:- For Wire manager 2 Numbers.

11

1

11

... More
12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 millimeter Prelaminated Particle board. All edges are covered by 2 millimeter. Thick. Poly Vinyl Chlorideedge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 millimeter Prelaminated Particle board. All edges are covered by 2 millimeter. Thk. Poly Vinyl Chloride edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18 millimeter both side prelaminated particle boards.All edges are covered by 0.8 millimeter PVC edge bands glued by hot melt glue applied by auto edge banding machine.

19

1

19

... More
Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery

294

1

294

... More
Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT.

12

1

12

... More
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.

30

1

30

... More
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (centimetre) Breadth (centimetre)): 100 (centimetre)Height (centimetre): 100 (centimetre) Weight (kilograms): 66 (kilograms) Seating Capacity: Five Seat

7

1

7

... More
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Height, with 4 adjustable shelves, Complete body & shutter made in 0.8 millimeter thick & Top in 2 millimeter thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.

83

1

83

... More
Tea Table 900 millimetre X 750 millimetre X 450 millimetre for Mild Steel ante chamber Providing And Fixing Of Tea Table 900 millimetre X 750 millimetre X 450 millimetre With 12 millimetre Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18 millimetre Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 millimetre Thick Veneer or 1 millimetre Thick Mica Etc.

2

1

2

... More
Making 150 millimetre diametre Bore in all types of Strata with head core including survey for fixing location of bore transporting of machinery and platform, providing laying fixing casing of 150 millimetre diametre Unplacticised Poly Vinyl Chloride Pipe (CS as per Indian Standard:12815) having outer diametre 165 and minimum thickness of 5.70 to 6.50 millimetre diametre along with grouting, checking capacity by flushing test etc. complete. Survey for Fixing Location

1

1

1

... More
Making Bore in all types of Strata

100

1

100

... More
Providing and Laying and fixing casing of 150 millimetre diametre Ultra Poly Vinyl Chloride pipe to withstand continous internal hydraulic pressure of 6 kilogram per square centimetre (Cross Section as per IS:12818-1992) having outer diametre 165.40 millimetre and minimum thickness 5.70 to 6.50 millimetre along with grouting.

50

1

50

... More
Checking Capacity by Flushing test

1

1

1

... More
Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 Killo Watt/5 Horse Power with 415 Volt, 50 c/s Alternating Current supply suitable for 150 millimeter diameter borewell suitable for 60 to 290 Liter Per Minute discharge at 112 to 12 meter head and discharge and delivery Pipe of Size-50 millimeter diameter with a necessary H type clamps as per specification No. WP-SMP

1

1

1

... More
Supplying and erecting flat flexible 3 core 2.5 square millimetre Polyvinyl chloride sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

50

1

50

... More
Supplying and erecting D.O.L Starter suitable for 415 Volt, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 Horse Power.

1

1

1

... More
Supplying amd erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 killogram capacity cartridge type conform to Indian Standard 2878 /15683 complete erected with necessary clamp made from 50 x 6 millimeter. Mild Steel flat with nut and bolts routed in wall complete.

4

1

4

... More
Supplying and erecting Minimum three and above star rated Centrifugal water pump (Monoblock), 415 Volt, three phase 50 cycles Alternating Current supply of 1.5 Killo Watt / 2 Horse Power with discharge 600/140 Litres per Minute (LPM) for head of 8/22 meter and 50 millimeter suction/ 40 millimeter delivery pipe on provided Cement Concrete foundation as per specification No. WP-CGP

1

1

1

... More
Directional signage : Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge.

50

1

50

... More
Rain Water Harvesting - Shallow Percolation Pit providing, constructing 2.0 metre deep shallow depth percolation pit comprising of 1.0 metre diametre precast Reinforced Cement Concrete rings, 300 millimetre thick side filling around outside of Reinforced Cement Concrete rings (annular space) with 40 millimetre size boulders including filling of percolation pit up to 0.5 metre depth (from bottom up) with 25-75 millimetre clean washed gravels followed by 0.5 metre depth of 10-25 millimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand/crushed sand Vertical Shaft Impact grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical Shaft Impact grade finely washed etc.) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Poly Vinyl Chloride rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge

4

1

4

... More
Electrical (B) Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit [1-2-2]

150

1

150

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No WG-MA/CON. [1-2-4]

100

1

100

... More
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]

2200

1

2200

... More
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No WG-MA/CON [1-2-8]

3850

1

3850

... More
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-9]

600

1

600

... More
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]

5600

1

5600

... More
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]

5600

1

5600

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]

3850

1

3850

... More
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]

3850

1

3850

... More
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]

2240

1

2240

... More
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]

2240

1

2240

... More
Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-10]

52

1

52

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]

161

1

161

... More
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]

156

1

156

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]

161

1

161

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]

170

1

170

... More
Supplying and erecting modular type telephone socket two gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-16]

12

1

12

... More
Supplying and erecting modular type computer Jack RJ45 with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-17]

97

1

97

... More
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]

196

1

196

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]

60

1

60

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]

223

1

223

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected. [1-6-32]

56

1

56

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 16 / 18 module duly erected. [1-6-33]

38

1

38

... More
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected. [1-6-43]

10

1

10

... More
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-19]

609

1

609

... More
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-20]

196

1

196

... More
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5]

199

1

199

... More
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2750 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-6]

12

1

12

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15]

15

1

15

... More
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]

309

1

309

... More
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. [2-3-13]

6

1

6

... More
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. [2-10-15]

52

1

52

... More
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]

196

1

196

... More
Supplying and fixing anchor type fastener fan hook with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. [2-11-2]

196

1

196

... More
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6]

196

1

196

... More
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-10]

10

1

10

... More
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. [3-2-26]

75

1

75

... More
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. [3-2-27]

75

1

75

... More
Supplying, installing, testing and commissioning of single phase 230V 50 Hz 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV [3-6-3]

3

1

3

... More
Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-3]

3

1

3

... More
Supplying and erecting 12V/150Ah tubular battery with battery terminal wire duly charged with 36 months warranty complete. [3-8-4]

6

1

6

... More
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-10]

24

1

24

... More
Supplying and erecting ON LOAD four pole automatic transfer switch 415V 200A 50 Hz with enclosure flexibility of neutral connection line and load reversibility changeover with phase barriers source separator terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV UV phase sequence changing single phasing and event logging connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . [5-1-12]

1

1

1

... More
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]

120

1

120

... More
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]

104

1

104

... More
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]

26

1

26

... More
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]

6

1

6

... More
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5]

4

1

4

... More
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 12 ways /36 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-6]

3

1

3

... More
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]

6

1

6

... More
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]

6

1

6

... More
Providing and erecting 4 Pole MCCB 415V 400A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [5-5-4]

1

1

1

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]

220

1

220

... More
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]

40

1

40

... More
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11]

12

1

12

... More
Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V aux. supply 90-300 V AC/DC flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage current frequency power factor kW kVA kVAR kWh kVAh kVARh phase angle interrupts THD complete with RS 485 communication protocol class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. [6-3-9]

1

1

1

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]

3

1

3

... More
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-28]

160

1

160

... More
Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]

2

1

2

... More
Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]

1

1

1

... More
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-16]

120

1

120

... More
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-28]

260

1

260

... More
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]

6

1

6

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]

42

1

42

... More
Electrical (C) Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]

2800

1

2800

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]

2100

1

2100

... More
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]

194

1

194

... More
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2]

97

1

97

... More
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18]

1

1

1

... More
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4]

4

1

4

... More
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16]

97

1

97

... More
Supplying, fixing, and configuring 24 ports POE switch in provided rack as per specification No. WG-NWC/ENS [1-11-3]

4

1

4

... More
Electical (D) Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]

12

1

12

... More
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]

12

1

12

... More
Supplying and erecting modular type 6 / 16A fuse unit duly erected on provided plate and box with wiring connections complete. [1-6-13]

12

1

12

... More
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-7]

60

1

60

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. [1-6-29]

12

1

12

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]

90

1

90

... More
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]

90

1

90

... More
Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF [2-10-16]

6

1

6

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15]

12

1

12

... More
Supplying and erecting 10-12W 230V integral type LED Lamp suitable for B-22 / E-27 base. [2-8-11]

6

1

6

... More
Supplying, erecting and marking DPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-6]

3

1

3

... More
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]

6

1

6

... More
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]

3

1

3

... More
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-7]

3

1

3

... More
Supplying, Erecting and Commissioning of 2 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-2]

3

1

3

... More
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]

3

1

3

... More
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-8]

210

1

210

... More
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-33]

210

1

210

... More
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]

9

1

9

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]

21

1

21

... More
SITC of Electric Traction Passenger Lift with · Rated capacity - 10 Passenger/680Kg · Floors - G+1 floor (2 Stops/2 Landings) · Travel - 3 to 4.2 mtrs · Location of Lift Machine - MR/MRL · Rated speed - 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of mm wide x mm deep x 2250mm high · Lift shaft available having clear size of mm wide x mm deep mm Pit depth mm Overhead. · Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with / without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open/close operation from COP etc. The system can record information for minimum 30 latest faults with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Domecamera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as T section adequate size guide rails for car & counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required & scaffolding for erecting guide rails providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. [17-1-13]

2

1

2

... More
SITC of Electric Traction Passenger Lift with · Rated capacity - 6 Passenger/408Kg · Floors - G+1 floor (2 Stops/2 Landings) · Travel - 3 to 4.2 mtrs · Location of Lift Machine - MR/MRL · Rated speed - 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000mm high · Clear Car size of mm wide x mm deep x 2250mm high · Lift shaft available having clear size of mm wide x mm deep mm Pit depth mm Overhead. · Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with / without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open/close operation from COP etc. The system can record information for minimum 30 latest faults with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Domecamera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as T section adequate size guide rails for car & counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required & scaffolding for erecting guide rails providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. [17-1-13]

1

1

1

... More
NOTE A2 FOR G+3 (2 ADDITIONAL FLOORS) For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel] this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking travelling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. complete for the safe functioning of lift installation. [17-1-13]

4

1

4

... More
NOTE A2 For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel] this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking travelling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. complete for the safe functioning of lift installation. [17-1-13]

2

1

2

... More
Electical (E) Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]

100

1

100

... More
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]

80

1

80

... More
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-33]

12

1

12

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36]

1

1

1

... More
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-10]

1350

1

1350

... More
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6]

100

1

100

... More
Supplying and erecting automatic control panel for 3 Ph 415 volt /centrifugal pump set up to 10 HP consisting of Star Delta starter having relay range 9-14 Amp S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc. [12-4-26]

1

1

1

... More
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet outlet overflow pipe inclusive of all tanks capacity up to 20000 litres. [4-8-7]

10000

1

10000

... More
Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP [13-3-1]

1

1

1

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-2]

6

1

6

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5]

12

1

12

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6]

54

1

54

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-7]

118

1

118

... More
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-19]

1

1

1

... More
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-20]

3

1

3

... More
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-21]

1

1

1

... More
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-23]

1

1

1

... More
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-25]

1

1

1

... More
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13]

2

1

2

... More
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4]

24

1

24

... More
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ [13-8-8]

12

1

12

... More
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FA/FMC [13-8-11]

1

1

1

... More
Supplying and erecting brass orifice plate having 6 mm. thickness 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP [13-8-17]

12

1

12

... More
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20]

12

1

12

... More
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories 16x2 Character LCD Display provision for zone wise contact and beep sound alarm suitable to operate on 120-220 V AC 0 - 49 Deg C 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP Rate For Two zone=Rs17839 ( Per Zone 25%=4459.75/-) Hence Total 6 Zone Addtional Hence (4459.75 X 6=26758.50/-) Total 8 Zone Reqired = 17839+26758.50= Rs 53517/- ) [13-9-14]

1

1

1

... More
Supplying, installing, testing and commissioning of optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD [13-9-3]

215

1

215

... More
Supplying, installing, testing and commissioning of manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP [13-9-7]

14

1

14

... More
Supplying, installing, testing and commissioning of hooters having high (100dB 1m) and low (94dB 1m) volume setting group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR [13-9-8]

14

1

14

... More
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1]

13

1

13

... More
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1]

1

1

1

... More
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13-11-2]

8

1

8

... More
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC [13-11-3]

2

1

2

... More
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11-4]

2

1

2

... More
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77]

12

1

12

... More
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]

811

1

811

... More
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14]

3

1

3

... More
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS [13-8-15]

1

1

1

... More
Supplying and erecting Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. Old DSR 21-22 (10-2-36)(13-15-1) [17-1-13]

17

1

17



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.