West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Telecommunication Services
Ireps
Opening Date18 Dec 2024
Closing Date15 Jan 2025
Tender Amount₹ 12,40,65,804.42 
Notes
Download

Costs

Summary

Supply, Installation, Testing And Commissioning Of Integrated Tunnel Communication Systems, Ofc/quad/leaky Cable

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 7/8" Leaky Radiating Cable Fire Retardant Low Smoking Zero Halogen (FRLSZH) rated as per Specification No. RDSO/SPN/TC/109/2023 Ver 1.0 with latest amendment/revision. INSPECTION by RITES

11

799120

8790320

... More
Supply of 1/2" RF Feeder Cable as per technical specification attached in Chapter - 2 of Part - II in tender document . INSPECTION BY CONSIGNEE

3

224760

674281.98

... More
Supply of N-Type Connectors for 1/2" RF Cable as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE

-

-

6

... More
Optical/CAT6 Patch cords with connectors as per OEM requirement- 10 Mtrs. INSPECTION BY CONSIGNEE

100

3609

360903

... More
Supply of N-Type Connectors for 7/8" Radiating cable as per OEM requirement or compatible with item No. 4 as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE

120

279

33562.8

... More
Supply of Stainless Steel Clamps for 7/8" Radiating Cable anchored using SS Bolts and 9 SS Anchor Fasteners (Stainless steel" shall be a Cr Ni-Mo alloy or Cr-Ni-Mo-Ti alloy, material No. 1.4404 or 1.4571 according to EN 10088 resp. 316 S 11 or 320 S 31 according BS) as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY RITES

4000

449

1798040

... More
Supply of Voice Recording equipment as per RDSO Specification No. RDSO/SPN/TC/038/2002 with latest Amendment/Revision . INSPECTION BY RITES

3

429632

1288898.64

... More
Supply of Nylon Clamps for 7/8" Radiating Cable using Stainless Steel Self-Anchoring Expansion Bolts as per technical specification attached in Chapter - 2 of Part - II in tender document . INSPECTION BY RITES

15000

349

5244300

... More
Supply of Jumper Cables 1 mtr in 1/2"SF Cable with N-N /DM NM terminations as per OEM of approved make as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE

100

1211

121167

... More
Supply of 2 way splitter for leaky cable connection/Adjustment as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY RITES

40

16842

673698

... More
Supply of 30 db coupler for coupling of Rf feeder cable as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE 15

20

16842

336849

... More
Supply of RF lighting and Surge Arrestor protection . INSPECTION BY CONSIGNEE

8

9623

76987.2

... More
Supply of Log-Periodic Antenna in VHF Frequency Band as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE

14

24972

349615

... More
10W Termination Load (PIM<=-150) for termination of leaky cable.as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE

10

3609

36090.3

... More
Supply of self support mast/Complete Triangular 11" or higher Lattice (Guyies) Mast 19 assembly along with mast mounting unit consists of: (a) Supply of Triangular 11" or higher Lattice (Guyies) Mast/ Self Supported Mast Assembly with sections of approx 03 mtr. each (b) MS pipes with IS certification of outer diameter of 1" or higher should be used. As per attached drawing. INSPECTION BY CONSIGNEE

300

1388

416409

... More
Supply of Armoured LSZH Cat 6A S/FTP Cable complete broadly conforming to RDSO standard RDSO/SPN/TC/65/2019 Rev.5 or latest. This item to be supplied with prior permission from Officer in charge as per the requirement at site. INSPECTION BY CONSIGNEE

-

-

20

... More
Supply of 3 core 2.5 Sq.mm multi strand copper conductor, of reputed make (Finolex/polycab/Havells or similar). This item to be supplied with prior permission from Officer in charge as per the requirement at site. INSPECTION BY CONSIGNEE

15000

53

808350

... More
Supply of Desktop Call Station, full IP based handset and microphone, functional keys as per technical specification attached in Chapter - 2 of Part - II in tender document etc all complete. INSPECTION BY RITES

4

134167

536669.92

... More
Supply of Emergency Audio & Video call station with two buttons rugged industrial grade suitable for tunnel applications as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY RITES

18

167400

3013200

... More
Supply of IP Horn Type PA Speaker, with mounting arrangement and all accessories etc all complete as per technical specifications attached in Chapter - 2 of Part - II in tender document. The material should be corrosion free. INSPECTION BY RITES 26

60

78722

4723367.4

... More
Supply of Amplifier 2400W ahuja LXA 2400 or equivalent . INSPECTION BY CONSIGNEE 27

3

36175

108526.95

... More
Supply of PA Amplifier INSPECTION BY CONSIGNEE

-

-

150557.8

... More
Supply of Thermal & Optical Bi-spectrum Network Bullet Camera (at tunnel faces) as per technical specification attached in Chapter - 2 of Part - II in tender document and compatible with VSS Network. INSPECTION BY RITES

8

262057

2096461.68

... More
Supply of Surge protection device (including all accessories) RJ45 POE-ODR (outdoor) 29 Suitable for use with surveillance cameras, access points, and other Ethernet-equipped device. The device should be suitable for outdoor use. Module- JMV/RJ45 POE-ODR or similar. INSPECTION BY CONSIGNEE

300

1770

531000

... More
Supply of covered 19'' Racks of size 2200 mm X 600 mm X 600 mm, Make: WQ/Vero President/Rittal/APC/Saraswat or similar or better, complete with all fittings including DC Fans (48 V) - 30 2 Nos, LED lights, seperator sheet/plate to keep testing equipments - 1 No and AC Power distribution panel (horizontal fitting) with power sockets and fuse/MCB protection (minimum 6 Nos of 230V- 15A/5A. combined) and other accessories. Rack should have compatibility with all equipment conforming to DIN 41494 or equivalent EIA/ISO/EN standard, Manufacturer must certify that products are compied with DIN41494 or equivalent EIA/IISO/EN/CEA/UL standards. INSPECTION BY CONSIGNEE.

6

50367

302204.64

... More
Supply of VRLA fully charged battery 48 V DC /300 AH (stackable) as per IRS:S- 93/96(A)(amd-1) or latest. INSPECTION by RITES

2

138997

277995.8

... More
Supply of SMPS based 48 V(2+1) FR/FC module,25 Amp single phase 230 V ,AC 32 operated battery charger for telecom use as per RDSO /SPN/TC/102-2013 (ver.0.0) with latest amendment ,in N+2 configuration i.e using 4 module of 12.5 Amp with automatic switching between the module suitable for one set.It shall be equipped with surge anf lighting protection of class B and C along with instruction and service manual. INSPECTION BY RITES

2

123007

246015.14

... More
Supply of switch board cable 0.5 mm/10 pair of Finolex/Bhansali / Delton make or Similar . INSPECTION BY CONSIGNEE 34

1525

55

84363

... More
Supply of Krone tool. INSPECTION BY CONSIGNEE

5

1043

5218.8

... More
Supply Specification No.RDSO/SPN/TC-37-2000(Ver.3) with latest Amendments as on the date of opening of& installation of Fiber Distribution management system as per RDSO tender (It includes the supply of 19" 12U rack with mounting arrangements. INSPECTION BY RITES

16

117396

1878341.44

... More
Supply, installation and programming of integrated Access Multiplexer 1U height,19" rack mountable with 4 DTE interface and one (V.21/V23) module supporting eight V21/V23 36 interface(2W/4W0,one talent port, one slot with low speed data interface RS -232, V24 of 8 port supporting baud rate as per technical specification in the annexure, one slot free, unit to support both AC/DC power supply, cable 50 pin SCSI connecters one number included, MROTEK Model MAPLE-4C or equivalent as per technical details Annexure " MAPLE". INSPECTION BY RITES

16

85674

1370792.64

... More
Supply of Ultra isolation transformer 230/230-1.5 KVA with MOVR protection on either side to provide "X" protection and supply of crow bar surge protection circuit for 48 V DC side to provide "y' protection. INSPECTION BY CONSIGNEE

6

18343

110060.94

... More
Supply and installation of class-B type lightening arrester for single phase supply along with class-c type surge arrester for single phase supply as per WC railway specification No WCR/SPN/Tele/08/01. INSPECTION BY CONSIGNEE

16

4624

73990.08

... More
Supply of permanently lubricated HDPE pipe 40/33mm dia. As per RDSO specifications 39 no. RDSO/SPN/TC/45/2013 with latest Amendment/Revision, suitable for armoured 24 fiber OFC cable with end cap, as required for the OFC system ( NOTE: At a time, the contractor will have to supply according to the requirement of the site with the approval of officer-in-charge). INSPECTION BY RITES 40

10

81733

817337.3

... More
End plug of HDPE pipe . INSPECTION BY CONSIGNEE 41

25

40

1004.25

... More
Plastic coupler for HDPE pipe . INSPECTION BY CONSIGNEE 42

40

54

2175.6

... More
Rotary duct cutter for HDPE pipe. INSPECTION BY CONSIGNEE 43

2

1613

3226.98

... More
Cable sealing plug for HDPE pipe. INSPECTION BY CONSIGNEE

40

54

2175.6

... More
Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring conforming to IS 14930 44 (part 2:2001), Non metallic, normal duty, pliable, without protection against chemical attack and fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia & 103.5 mm inner dia. INSPECTION BY CONSIGNEE

180

284

51139.8

... More
Supply of 100 mm GI pipe medium grade of IS specification No 1239 (pt-1) 2004 or 45 latest with sockets and fittings, nominal dia 100mm outside dia (Max 115.0mm, Min 113.1mm), Thickness (4.5mm), Mass plain end (12.2Kg/m), Mas Screwed and socketed (12.5 Kg/m), Tolerance in Thickness {(+) not limited, (-) 12.5 percent)} and Tolerance in Mass (+ 10 %, - 10%). INSPECTION BY RITES

1800

1207

2173806

... More
Supply of 24-fiber armoured optic fiber straight joint enclosure (SJC) complete with all accessories as per RDSO/SPN/TC/68/2007 with latest Amendments. INSPECTION BY CONSIGNEE

30

4997

149925

... More
Supply of office Table similar to model 'T-104' Godrej make-or similar. Dotted 47 embossed cable duct and perforated steel modesty panel on visitors side. All steel components are epoxy powder coated after seven tank corrosion treatment of surface with three drawer on both side. Godrej or similar. INSPECTION BY CONSIGNEE

4

15504

62017.52

... More
Supply of revolving chair similar to Godrej Greta 2.0 High Back . Make: Godrej or Similar. INSPECTION BY CONSIGNEE

4

14072

56291.8

... More
Steel Almirah of size 1980H x 915 W x 485 D with 4 adujstable panels making 5 49 shelves (without locker for office use). Almirah shall be made from CRCA steel sheet of 20 gauge ( for panel partition). Almirah shall be 100% epoxy powder coated Make Godrej or equivalent. INSPECTION BY CONSIGNEE

4

20145

80582.52

... More
Supply of VF tapping transformer as per IRS/TC/22/76 of impedance ratio -600:470 . INSPECTION BY CONSIGNEE

36

1578

56821.68

... More
Supply of One Quad V.F. 2-T Transformer joint assembly of VF Transformers /1120:470 as per IRS/TC/76/2000. INSPECTION BY CONSIGNEE

50

1986

99317

... More
Supply of 1 x 6 Sqmm (Red/Black/Green) multi strand copper power wire as per 52 IS:694:2010 or latest, 84 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. INSPECTION BY CONSIGNEE

7000

30

215740

... More
Supply of 6U, 19" covered Rack with (1) front side transparent door with lock 53 arrangement(2) cable organizer (3) provision of one no. of power supply (each consists of 6 Nos x 15A/15A multipin sockets with ON/OFF switch and fuse arrangement) strip HCL or Rittel or APW or President od D-Link or Similar) INSPECTION BY CONSIGNEE

30

5225

156750.3

... More
"Supply of IP 66 Cabinet for the installation of Emergency Audio call station with all required accessories, Certified by manufacturer as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE.

18

10250

184501.8

... More
Supply, Installation and Commissioning of 2x10 KVA On-line UPS at least 2 Hour 56 Backup in full load condition, connected in parallel redundant mode. Complete with all accessories as per specification attached. This also includes supply of two set MF batteries of suitable AH capacity, Rack, One set compatible MCBs, complete with cover & fixing materials, One Earth leakage circuit breaker arrangement. INSPECTION BY RITES

6

443263

2659583.76

... More
Supply of PVC conduit pipe 1" diameter or better( medium grade-1.4 mm thick minimum) of ISI marked of reputed brand. INSPECTION BY CONSIGNEE

9000

45

408600

... More
Supply of automatic fusion splicer fully automatic RTC microprocessor controlled ( ARC fusion type) splicer with VIDEO display, warm image processing, Heat oven, Fibre fixtures, battery 58 backup, high precision fibre cleaver, stripping tool and other compatible accessories of Fuzikura model No. FSM-50S or equivalent model of Fuzitsu or Siemens or latest along with sufficient no. of splice protection sleeves and bottle of isopropyl alcohol to be supplied for test splice. As per TEC specification No GR/OSM/01/03 APR 2005 with latest amendments in force at the time of tender opening. INSPECTION BY RITES

1

962095

962095.78

... More
Supply of Mini OTDR MTS-5100 suitable for 1310/1550 nm fibre with resolution of 60 59 cm dynamic range of 31/29 db or better with all accessories, USB drive with a flash ROM of minimum 1Gb, AC adaptor/Charger, Rechgeable battery, Manuals, Hard and Soft carrying case etc as per TEC specification No TEC/GR/TX/OTD 01/04 APR 2010 with latest amendments in force at the time of tender opening. INSPECTION BY CONSIGNEE

1

689856

689856.3

... More
Supply of remote service terminal (with Laser Printer) fully compatible with Tunnel Communications service terminal shall be for any location as per Chapter - 2 of Part - II in tender document. INSPECTION BY CONSIGNEE.

4

172546

690187.16

... More
Supply of office /visitor chair with seat padded with polyurethane foam visitor. These 61 chairs should be non revolving type and the arms of chair should have cover for suitable length. Make: Godrej or Similar. Model No. - PCH7003, For Government Office,Offices, Size: 55w X 61d X 80.5h X 44 Sh Cm INSPECTION BY CONSIGNEE

12

8334

100012.56

... More
Supply of maintenance free earth consisting as per RDSO specification Nos RDSO/SPN/197 ver.1 or latest. consisting of single earth pit which include supply of 35 mm/16mm/10mm multistrand single groove PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manfactures 62 recommendations and as per RDSO specification. (a) Copper bonded steel electrode of 3.0 meters long, 17 mm diameter with copper bonding thickness of minimum 250 microns and UL listed and marked :1 nos. (b) Earth enhancement compound of RDSO approval brand supplied in sealed bag of minimum 10 kg : 3 Nos. (c) Copper strip of 150 mm X 25 mm X 6 mm to terminate earth rod : 1 Nos. (d) Copper strip of 300 mm X 25 mm X 6 mm (MEEB) : 1 Nos. (e) Copper strip of 150 mm X 25 mm X 6 mm (MEEB) : 1 Nos. INSPECTION BY RITES

20

21510

430215

... More
Supply of fire extinguisgher 4.5 Kgs,Co2 gas ISI make with test certificate, make Minimax, VINTAX or Similar. INSPECTION BY CONSIGNEE

6

8524

51149.34

... More
Supply of PC WorkStation for Viewing, Monitoring and System Management [Detailed Specification in Technical Document].RDSO Spec No. RDSO/SPN/TC/65/2021, Rev 6.0 or latest. INSPECTION BY RITES

2

256244

512489.08

... More
Supply of 55" LED Full HD Large Format Display (Qty -4 Nos.) as per RDSO Spec No 65 RDSO/SPN/TC/65/2021, Rev 6.0 or latest with HDMI and DVI Ports complete with all accessories. It includes supply and installation of Matrix switch/Controller, Cables etc and LED wall Mount/ stand and all accessories required for installation as per technical specification attached in Chapter - 2 of Part - II in tender document. INSPECTION BY RITES

2

3301809

6603618.88

... More
Supply of Power Backup provision for Master unit & Optical Remote unit as per RDSO specification No.RDSO/SPN/TC/109/2023 Ver 1.0 with latest amendment. INSPECTION BY RITES

13

80839

1050915.84

... More
Supply & installation of 5 KVA On-Line UPS with isolation transformer suitable for single phase AC output, Floor Mounted Type with sealed maintenance free batteries complete one hour backup. INSPECTION BY CONSIGNEE

10

78734

787343.9

... More
"Supply of 8 port Layer 2 managed network switches. 8 ports PoE L-2 switch of 68 10/100/1000 MBPS with 2 nos.10/100/1000 Base-T/SFP port with supply of 02 nos.SFP module as per clause 13.0 of RDSO/SPN/TC/65/2021, Rev 6.0 or latest & as per clause 4.0 of RDSO/SPN/TC/83/2014, Rev 1.0, Amndt 1.0 or latest. INSPECTION BY RITES "

35

16971

594014.4

... More
Supply of Material,fabrication,and installation of frame & door for Horn, speaker,CCTV 69 camera,6U/9U rack & other safety equipment. Size 0.7 meters(L)x0.45 meters(W)x0.45 meters (H) (Side Angle thickness 0.3 mm, Mesh ( 0.1 m x 0.1 m), Mesh rod gauge 0.3 mm) or as per site requirement. INSPECTION BY CONSIGNEE

55

4320

237600

... More
Supply of Material, fabrication, and installation of frame & door for SOS Phone & other 70 safety equipment. Size 0.350 meters(L)x0.140 meters(W)x0.450 meters (H) (Side Angle thickness 0.3 mm, Mesh (0.1 m x 0.1 m) rod gauge 0.3 mm ) or as per site requirement. INSPECTION BY CONSIGNEE

18

2976

53568

... More
Supply of Material, fabrication, and installation of safety door for VHF Set Power supply 71 unit with dimensions of 2.87 meter in height, 1.99 meter in width and length 0.60 meter ( Side Angle thickness 0.5 mm (Inside Mesh (0.1 m x 0.1 m), (rod gauge 0.8 mm) or as per site requirement. INSPECTION BY CONSIGNEE

6

30000

180000

... More
Supply and installation of a covered rack for a UPS with dimensions of 1.0 meter in 72 height, 0.7 meter in length , 0.4 meter in depth to be placed inside the tunnel for VHF system ( Side Angle thickness 0.5 mm (Inside Mesh (0.1 m x 0.1 m), (rod gauge 0.8 mm) or as per site requirement. INSPECTION BY CONSIGNEE

29

9000

261000

... More
Installation, Configuration, testing, monitoring and Commissioning of Off-Air BDA/Main Base Radio Unit and linking with the Master unit for Re-broadcast. Also includes installation & configuration of NMS.

3

101588

304764.39

... More
Installation, Configuration, testing, monitoring and Commissioning of Remote Optical unit along with required accessories. Also includes installation & configuration of NMS.

10

60952

609528.8

... More
Laying of RF Cable with Labelling with descriptions of antenna, component and accessories.

3000

124

374580

... More
Laying of 7/8'' Leaky Radiating Cable and required accessories on tunnel wall along with required accessories, with contractors tools and labour etc complete.

11000

249

2747030

... More
Installation, Testing and commissioning of Desktop Call Station, full IP based handset and microphone, functional keys as per technical specification etc all complete.

4

33541

134167.48

... More
"Installation, Testing and commissioning of IP Horn Type PA Speaker, with mounting arrangement and all accessories etc all complete as per technical specifications. The material should be corrosion free.

-

-

6

... More
Installation, Testing and commissioning of IP 66 Cabinet for the installation of Emergency Audio call station.

18

1138

20500.2

... More
Installation, wiring and testing of battery sets and battery chargers for optic fibre circuits. This includes installation of AC and DC power supply distribution board with MCB's of suitable rating, wiring of external alarm contacts, Fixing arrangements for battery and charger in the equipment room with 25 sq.mm Multistrand single core Copper cable PVC insulated from Battery charger to Battery with suitable copper lugs crimped/soldered to it , 16 sq.mm Multistrand single core Copper cable PVC insulated from battery charger to power distribution panel in the rack with suitable 8 copper lugs crimped/soldered to it . Connection from Battery Charger body and battery+ve terminal to Earth terminal by 16 Sq.mm Multistrand single core Copper cable PVC insulated seperately with suitable copper lugs crimped/soldered to it and Extension of AC 230V power supply wiring through PVC pipe with 6 sqmm cu.wire for phase & neutral and 1 sqmm cu .wire for earth to the 19" rack ( Copper cables , 20A metal clad with MCB for AC supply to fix in the wall , conduits and other miscellaneous materials required for the work should be supplied by the contractor.(Inspection by Consignee). This work also includes transportation of materials from stores/supplied by Railways for installation.

6

16735

100413.42

... More
Laying of STP/OFC/Power Cable/Swich board(10 pair/ 20 pair/50 pair) Cables in 1" PVC 9 conduit/case caping and clamping on the wall/ Wall/Roof tops/ Shelters with suitable clamping and hose to be provided where ever bends/ curves (PVC conduit/ Case capping and other accessories to be supplied by the contractor).

1500

39

59490

... More
Integration, Testing and Final commissioning of equipments at each station for all the 10 equipments conforming with the approved system design including end to end testing for realization of optical fibre system. This also includes supply of all as made documents for the entire installations plus technical, maintenace and installation manuals for Tunnel Communication and VSS project.

2

169572

339145.22

... More
Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own 12 splicing machine and tools. Joint should be prepared in such a way that the top of the enclosure shall be at a depth of 1.2 Mtr. and the enclosure must be covered with sand. Acceptance Test procedure of WCR has to be followed for testing. Continuity of the OFC Armour should not be maintained.

10

12420

124205.2

... More
Transportation and installation of Fiber Management System and splicing, and termination (2 x 24) or (2 x 48) optic fiber cable of the both ends as per site requirements, complete with all required materials and accessories at contractors own cost.

15

2634

39514.5

... More
Writing work of cable termination details of 6-quad, OFC, PIJF and other cables & equipments details at OFC Room/Cable hut/VSS Control Rooms & Station Building and wherever necessary as per direction of Engineer in-charge.

8

1467

11740.16

... More
Construction on main hole of size 1mtr.dia and 600mm deep ferro cement joint box for 15 OFC Joints.The main hole shall have a thickness of 50 mm . and shall be as per drawing attached. (The top cover RCC Slab of the main hole should have a thickness of 75 mm) Drg. No.SK/DRM (S&T)/JBP/OFC/010 & 011.

5

8714

43572.85

... More
Supply, Fixing and Wiring of Cable Termination box for 26 conductors 0.5-0.9 sq mm 16 with screw type terminals consisting of the following parts complete of Phoenix Contact make or of Wago/Connectwell make. Fixing to be done as per instructions of Railway supervisor at site. Protection devices at Tunnel openings or other locations (supplied under this schedule) shall be provided on the terminals where jelly filled cable terminated. INSPECTED BY CONSIGNEE

14

4963

69490.54

... More
Laying of Power cable through one inch dia PVC conduit pipe/HDPE pipe. The rate include laying and installation/clamping charges of PVC pipe/HDPE pipe with protective arrangements in addition to laying of Power cables.

4500

36

164385

... More
Supply and installation/fixing of Wall Mountable RJ45 Socket and Face Plate with shutter and network module as per instructions of site engineer. INSPECTION BY CONSIGNEE

-

-

18

... More
Laying of STP/OFC/Power Cable/Swich board(10 pair/ 20 pair/50 pair) Cables in 1" PVC 19 conduit/case caping and clamping on the wall/ Wall/Roof tops/ Shelters with suitable clamping and hose to be provided where ever bends/ curves (PVC conduit/ Case capping and other accessories to be supplied by the contractor)

4500

27

123300

... More
Excavation of trench 1.20 mtr deep,300mm wide at the bottom along main line in all type of soil, including clearing of bushes, trees etc and refilling of the trench by excavated soil and 20 ramming after laying of the required quantity of cables as per instructions of Engineer at site. The work also includes excavation of trenches in the beds of culverts. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

12

92796

1113559.92

... More
Excavation of cable trench 300 mm wide at the bottom and 1.20 meter deep in hard soil mixed with boulders/ hard murum soil in rocky area including clearing of trees, bushes and 21 refilling of cable trench by excavated soil, murrum, boulders etc. Care should be taken while refilling the cable trench such that the murrum/ boulders etc does not damage the cable. Ramming after laying of cable (a) 24 Fiber OFC (b) 6-quad ( c) Jelly filled & power cable etc, Where desired dimensions could not be achieved, proportionate payment will be made as per instructions & approval of Engineer in-charge of the Railway at site.

2

158690

317381.12

... More
Excavation of cable trench 1.2 mtr deep, 300mm wide at the bottom across the track, 22 for track crossing and refilling after laying of DWC/GI and HDPE duct. The work shall be executed as per instructions of Rly. Engineer at site. Two Nos. of nylon ropes shall be drawn inside the DWC/GI and HDPE duct so laid for pulling of telecom/OFC cable as well as HDPE Duct by the Contractor.

100

253

25373

... More
Excavation of cable trench 300mm wide at the bottom and 1.20 meter deep at all type of road crossing/platform and ramming of the trench restortion of the surface to it origional condition after laying of OFC cable through DWC pipe.

520

268

139479.6

... More
Transportation and Laying of HDPE duct as per approved cable route plan in the 24 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

12

10208

122501.4

... More
Blowing and drawing of OFC through laid HDPE duct already provided in the excavated 25 trench as per approved cable route plan, taking due care while transporting and sealing both the ends after laying. The cable should be blown according to the technical conditions and the instructions of the site in-charge.

12

34896

418761.36

... More
Cutting of all types of Roads / platforms and digging of cable trench 450 mm wide at 26 the top 300 mm wide at the bottom and 1.65 meter deep at railway station area and ramming of trench and restoration of platform to it origional condition. This also includes laying of any No. of DWC/RCC/GI pipes, as per requirement. The work shall be done as per extant practice on WCR and instructions of Rly engineer at site. The pipe will be supplied by Rly.

300

268

80469

... More
Laying of 6 quad /jelly filled cable as per approved cable route plan in the excavated trench, taking due care while transporting and sealing both the ends after laying. The cable should be laid according to the technical conditions and the instructions of the site in-charge.

12

7723

92679

... More
Supply and laying of well burnt second class bricks of size 225mm x 100mm x 75mm approx. on laid cable in station area i.e. Outer/Home signal to outer/Home signal and yard and where ever necessary as per directive of Engineer in-charge.

27000

4

123390

... More
Fixing & laying of 100MM/80mm dia G.I. pipe (Supply of GI Pipe is covered separately 29 in Schedule "A") on parapet wall/ roof of culverts, including masonry work at both ends with contractors own material and bending of the pipe at the both ends etc. as per directive of Engineer in- charge. Perforation should be done before laying of GI pipes.

300

103

31119

... More
Fixing of GI pipe 100/80 mm dia to carry all the cable at the cabin,station,cable hut,and other building etc with contactors own material. GI pipe supplied by Rly.

200

71

14238

... More
Preparation of cable way 150 mm wide at the bottom and 300 mm deep in Rocky area / Tunnels (As a special case) and refilling the same after cable laying with concrete mixture at 31 proportional 1:3:6 and grouting the end at either side of the rocky portion using concrete mixture with contactors own material. Laying of cables is covered in seperate item (In the matter of protection of Telecom cables in Tunnels between CC ducts, the officer-in-charge will decide how to operate this item).

200

865

173074

... More
All work pertaining to Horizontal Directional Drilling (HDD) / Boring and trenchless 32 cabling. It includes supply, transportation and insertion of self lubricated HDPE Pipe in boring under the Track/Road/Platform/Tunnels/Circulating area by using different sizes of pipes depending on total no. of cables will be crossed. The depth of horizontal boring decided by officer in-charge as per site requirements.

150

2364

354613.5

... More
Supply, Installation, Engraving and Painting of cement concrete (a) cable route marker 33 @ 50 mtr distance, (b) Joint Marker for OFC (c) Joint Marker for 6 Quad as per drawing No. WCR/TELE/OFC/07/03. Sample to be approved by Engineer in-charge of the railways before supply, after the testing prescribed in the drawing.

200

924

184892

... More
Fixing and supply of screw type terminals for conductor size 0.5-0.9 sqmm in 19" 42 U euro rack and cable termination panel( to be supplied seperately under this schedule) by fixing hylum 34 strip of 10 mm thickness of suitable length and breath consisting of the following parts complete of phoenix contact make or wago/connectwell make.All fixing materials and hylum strips should be supplied by the contactor.Fixing to be done as per instructions of railway engineer at site, Each incoming and outcoming conductor of under ground jelly filled cable shall be provided with surge protection device.

6

4963

29781.66

... More
Installation of maintenance free earth. (a) Digging/Auguring/Boring of single earth pit of 100 mm to 125 mm dia to the depth of approximate 2.8 M. (b) Insertion of 3 Mtr electrode and penetrating it at least 0.2 mtr. By pushing gently with sledge hammer where the neutral soil is assumed. (c) Filling of earth pit with earth enhancement compound (EEC) in slurry form and back filling. (d) Carrying out exothermal weld connection on the copper tape of 150 x 25x 6 mm. (e) 35 Carrying out exothermal weld connection on the copper tape of 150 x 25x 6 mm on earth electrode for connecting two 35 sq.mm cable for redundancy. (f) The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which include graphite moulds, clamps, weld metal powder. (g) 300 mm x 300 mm x 300 mm (inside dimensions) concrete earth pit with a concrete lid approximately 50 mm thick with pulling hooks shall be provided to cover the pit. Back side of the cover will be painted in black and date of testing and average earth resistance value shall be written.

32

10930

349779.2

... More
Fabrication, Fixing , Grouting and cable termination of EC socket of EC socket assembly complete with termination of 6 quad & jelly filled cable with contactor own material.

12

4676

56115.36

... More
Installation, Testing & Commissioning of 6U Network Rack

30

1033

31004.4

... More
Providing brick masonary in the ratio of 1:6 cement and sand including plastering 20mm thick on each side with contractor own 2nd class bricks.

18

4123

74229.84

... More
Provision of cement concrete 1:3:6 with 25 mm graded stone aggregate and curing of the same as per above NOTE.The CC work is to be done at the location approved by engineer incharge.

98

3929

385051.8

... More
Laying of STP/OFC/Power Cable/Swich board(10 pair/ 20 pair/50 pair) Cables in 1" PVCconduit/case caping and clamping on the wall/ Wall/Roof tops/ Shelters with suitable clamping and hose to be provided where ever bends/ curves (PVC conduit/ Case capping and other accessories to be supplied by the contractor)

1500

39

59490

... More
Installation, commissioning including all necessary fittings, joints etc. of self-supporting 43 antenna Galvanized mast for VHF Simplex System with all accessories duly painted in Red & White alternate bands conforming to Fig. 2 of RDSO Spec. No. RDSO/SPN/TC/109/2023 Ver 1.0 or latest to establish tunnel communication in schedule A.

20

19278

385560.4

... More
Transportation, installation, testing and commissioning of Higher Lattice (Guyies) or Self Support Mast. The sections should be painted orange/red and white alternatively.

300

3094

928377

... More
Excavation of concrete foundation. All the material required are to be supplied by the contractor. This includes 1) Cement concrete foundation of size approx 1meter x 1meter x 1meter 45 shall be prepared for Lattice (guyies) mast. The exact size shall be decided on soil conditions. 2) Cement concrete foundation of size approx 2 meter x 2meter x 2meter shall be prepared for self supported mast. The exact size shall be decided on soil conditions. 3) The ratio of casting of cement concrete foundation shall be 1:3:6 all the work will be executed as per specification and advised by site engineer As per attached drawing. Qty. unit treated as Cu. Meter.

120

3404

408549.6

... More
Calibration, Testing and Installation of 55" LED Display as per specification enclosed (QTY-4 numbers). It includes all accessories required for installation as per specification enclosed.

2

825452

1650904.72

... More
Installation Testing and Commissioning of PC WorkStation for Viewing, Monitoring and System Management [Detailed Specification in Technical Document].RDSO Spec No. RDSO/SPN/TC/65/2021, Rev 6.0 or latest.

2

64061

128122.26



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.