West Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Electrical Goods and Equipments
Machinery and Tools
Electrical and Electronics
Ireps
Opening Date7 Dec 2024
Closing Date9 Jan 2025
Tender Amount₹ 1,28,36,960.23 
Notes
Download

Costs

Summary

S&t Work In Connection With Construction Of Rob At Lc Nos.242, 292, 295 & 301 Of Jabalpur Division On West Central Railway (signalling Work).

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of end stop suitable for disconnect terminal block INSPECTION BY CONSIGNEE

1200

10

13128

... More
Supply of Earth Electrode assembly as per WCR Drawing no. S&T/Con/KOTA/Earthing/01. Inspection by Consignee

23

1238

28485.73

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg.Nos. SA - 23748 Alt. 4 and Spec.Nos. IRS-S-75/2006 with INSPECTION BY RDSO

350

186

65310

... More
Supply of Non-deteriorating type low voltage cartridge fuse rate current 2 Amp / 4 Amp in equal proportion round head type as per specification Nos. IRS/S/78/92 with latest amendment. INSPECTION BY RDSO

350

80

28273

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . INSPECTION BY CONSIGNEE

15

4092

61393.2

... More
Supply of basic material to construct Unit Maintenance Free Earth consisting as per RDSO Spec No. RDSO/ SPN/ 197/2008 (or with latest Amend) consisting of : a) Copper bonded steel electrodes of 3.0 m long, 17.2 mm dia with copper bonding thickness of min 250 micron and UL listed and marked - 1 No. b) Earth Enhancement compound of approved brand supplied in sealed bags of min 10 Kgs - 3 Nos. c) Copper Strip of 150 x 25 x 6mm to terminate Earth Rod - 2 No. d) Copper Strip of 300 x 25 x 6mm (MEEB) - 1 No. Procurement should be done by RDSO approved source. INSPECTION BY CONSIGNEE.

-

-

10

... More
Supply of Tag Blocks 200 way with cover as per IRS: S- 77/2006 (Rev. 1) with latest amendment and Drg Nos.SA-24751. INSPECTION BY CONSIGNEE

58

1671

96927.28

... More
Supply of QNA1 (AC immunised relay), 8F-8B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23 INSPECTION BY RDSO

100

4647

464779

... More
Supply of Time Element Relay (Clock work type) AG timer of Siemens Make (Nos RSSK 30/0052) or functional equivalent with timer range up to 120 seconds. INSPECTION BY CONSIGNEE

8

10189

81517.6

... More
Supply of Relay Non-AC Immune, plug-in-type, DC Neutral Line 60V 4F/4B, 5F/3B, 14 6F/2B contacts, front and back contacts metal to metal, conforming to IRS: S 46 and firm's specification. The relay housing shall contain two miniature identical relays in mini group housing complete with base plate, Siemens make (RSSK 30/0011)/ ABB or functional equivalent As per site requirement. INSPECTION BY RDSO

80

10037

802976

... More
Supply of Relay Plug In type two DC neutral line in mini group housing, complete with 15 base plate consisting of Top relay AC immunized & Bottom relay both AC immunized, each 60V, 5F/3B, contacts, front and back contacts metal to metal conforming to IRS: S46 and firms specification. Siemens make (RSSK 30/0078-1), ABB or functional equivalent As per site requirement INSPECTION BY RDSO

40

11923

476931.6

... More
Supply of Relay Plug In type, two DC neutral line, mechanically interlocked, in mini 16 group housing, complete with base plate each 60V, 4F/4B contacts, front and back contacts metal to metal conforming to IRS: S 46 and firms specification. Siemens make (RSSK 30/0012) ABB or functional equivalent As per site requirement INSPECTION BY RDSO

20

10600

212015.6

... More
Supply of Apparatus cases with miniature E Type Locks with keys. (E Type Locks & keys as per spec. No IRS: S-30/64 & RDSO Drg. No. SA 3376/M & SA 3377/M with latest amendments). FULL CASE as per Drg NoWS-8842 with latest alteration. INSPECTION BY CONSIGNEE

6

13324

79948.02

... More
Supply of lamp holder switches, two pin for location box make anchor or equivalent. INSPECTION BY CONSIGNEE

4

102

411.4

... More
Supply of PVC insulated railway signalling indoor single core [ tinned jumper wire] 1X 0 . 6 mm dia as per RDSO spec. Nos. IRS:S-76/89 with latest amendments of various colours. INSPECTION BY CONSIGNEE

4

2695

10781.84

... More
Supply of PVC insulated flexible wire 16/ 0.2 mm dia as per RDSO spec. Nos. IRS:S- 76/89 with latest amendments of various colours. INSPECTION BY CONSIGNEE

13

6509

84623.5

... More
Supply of PVC indoor cable 1x60x0.6 mm dia having colour coding of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

1

252814

252814.12

... More
Supply of PVC indoor cable 1x40x0.6 mm dia having colour coding of insulation of inner core shall be four colours viz. Yellow, White, Pink & Voilet and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

1

184031

184031.47

... More
Supply of PVC indoor cable 1x24x1 mm dia having colour coding of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

2

235594

471189.34

... More
Supply of flexible cable single core multistrand copper conductors, 1x6 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

2

77238

154477.42

... More
Supply of Jumper wire 1X1mm dia as per RDSO spec, IRS:S-76/89 with latest amendments of various colours. INSPECTION BY CONSIGNEE

4

8166

32665.36

... More
Supply of flexible cable single core multistrand copper conductors, 1x2.5 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

2

20651

41302.46

... More
Supply of ARA Terminal Block made of PBT as per Drg No SA 23741 alt 3 & spec. No IRS S 75/2006 with latest amendments with disconnecting links. INSPECTION BY RDSO

1200

69

83868

... More
Supply of QNA1K (AC immunised relay), 8F-8B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23. INSPECTION BY RDSO

20

3628

72570.2

... More
Supply of Relay Rack Assembly Complete With Scaffolding, Fixtures and accessories 29 including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket,11 Way Bus Bars with cover and mounting brackets, runway for cable/wires frame base assembly etc. Siemens type & as per extant practice on WC. Rly. Typical part list as per Annexure M and Rack plan as approved by Engineer in-charge. INSPECTION BY CONSIGNEE"

2

43454

86908.58

... More
Supply of Apparatus Case with miniature 'E' type locks with keys (1 key per 5 location 32 boxes) of ward Nos. 41 (E type lock & key as per spec. Nos IRS S 30 & RDSO Drg.Nos. SA 3376/M & 3377/M respectively with latest Amendment) on both the doors, duly painted with red oxide. HALF CASE as per Drg Nos WS- 8842/A with latest alteration. INSPECTION BY CONSIGNEE

2

12173

24346.1

... More
Supply of Main Signal Post 140 mm outer dia 4.5 Mtr Length as per spec No IRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE

3

6655

19967.49

... More
Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia. Medium class IS Specification IS:1239 Pt-1/1990). INSPECTION BY CONSIGNEE

2

2218

4436.48

... More
Supply of Cast Iron Main signal surface base 140mm as per spec Nos IRS S 10 and Drg 35 Nos 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5 Mtrs long as per RDSO Drg. Nos. SA-23156. & signal front staging complete assembly. INSPECTION BY CONSIGNEE 36

3

9742

29227.35

... More
Supply of Signal Nos. plates. as per Drg enclosed. INSPECTION BY CONSIGNEE

4

480

1923.4

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signaling 37 suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Ver. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/ 1997 or latest INSPECTION BY CONSIGNEE

1

26983

26983.06

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signalling 38 suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M (Adv.) and as per SPEC. No. RDSO/SPN/194/2006 Rev.2.0 or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/ 1997 or latest. INSPECTION BY CONSIGNEE

2

28267

56535.92

... More
Supply of Calling-on Unit suitable for LED signal as per RDSO Drg no 24351(Adv.) Alt1 complete along with itsbase & clamping arrangement. INSPECTION BY CONSIGNEE

1

2784

2784.45

... More
Supply of 2 Way Junction Type Route Indicators as per RDSO Nos.SA23401-6 as per IRS:S-66/84amndt-1 or latest. INSPECTION BY CONSIGNEE

1

34542

34542.57

... More
Supply of position light shunt signal Unit. as per RDSO Nos. SA23840. INSPECTION BY CONSIGNEE 42

1

7744

7744.23

... More
Supply of Offset Bracket 3-1/2" for shunt signal. INSPECTION BY CONSIGNEE

1

489

489.31

... More
Supply of Offset bracket 5 1/2" suitable for 140mm outer dia of main signal. INSPECTION BY CONSIGNEE

2

972

1945.58

... More
Supply of track lead junction boxes as per Drg. Nos. RST11509 made from fiber glass along with terminal blocks. The TLJB should be BLACK in colour. INSPECTION BY CONSIGNEE

12

856

10272.96

... More
Supply of B type choke to specn.Nos.IRS.S.65/83 with latest amendments. INSPECTION BY CONSIGNEE

2

2971

5943.5

... More
Supply of adjustable Track Feed Resistance, 30 ohms as per RDSO Drg. Nos. SA- 20161-66M/M with latest amendments (with Phenolic moulded base). INSPECTION BY CONSIGNEE

2

1051

2102.9

... More
Supply of Track feed battery chargers of 10A rating to Specn. Nos.IRS:S.89/93 with latest amendment. Charger shall be suitable for charging 80 AH battery. INSPECTION BY RDSO

2

1879

3758.14

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope 48 should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Reclaimed or recycled material should Not be used. INSPECTION BY CONSIGNEE

400

56

22548

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Consignee inspection under manufacturer certificate. INSPECTION BY CONSIGNEE

10

234

2340.2

... More
Supply of DWC pipe 120 mm outer dia 103.5 mm inner dia made of polyethylene in 6 mtrs. straight lengths along with one coupler for every 6 mtr.as per specn. Is14930 or latest anti rodent and flame retardant. Or as per site requirement. INSPECTION BY CONSIGNEE

300

326

97944

... More
Supply of GI Boom as per RDSO drg. no. S-11600in 4 sections of 8 feet, suitable for Global/Heidz Lifting Barriers. INSPECTION BY CONSIGNEE

12

8300

99601.8

... More
Supply of low maintenance Lead Acid Secondary Cells 2V/ 80 Amp Hr. as per spec. IRS 88/93 with latest amendments. INSPECTION BY RDSO

30

2059

61774.8

... More
Supply of DC-DC converter 24-40 V/5A or 12-40V/5A or 24-40/5A or 60-100 V/1A or 53 any other module required as per site requirement for IPS as per RDSO Spec.NO RDSO/SPN/165/2012 or latest amendment. Contractor will take approval before supply of this item.(with Input/ output connection) for IPS INSPECTION BY RDSO

40

17067

682697.6

... More
Supply of Desk type Electronic Magneto Telephone as per spec No IRS TC79/2000 or with latest Amendments. INSPECTED BY CONSIGNEE

40

3248

129953.6

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239PT. 1/2004 with sockets and fittings. INSPECTION BY CONSIGNEE

60

1203

72221.4

... More
Supply of Thermo Shrinkable Jointing Kit (TS4) as per spec.no. IRS TC.77/2012 (Rev3.0) amdT 3 or latest for joints for 6 Quad cable of 0.9 mm dia conductor jelley filled UG cable from RDSO approved firms. INSPECTION BY RDSO

8

3199

25593.84

... More
Supply of PLB-HDPE duct outer dia meter 40 mm & inner diameter 33 mm as per RDSO/SPN/TC/45/2013, Rev.2.0,Amendment 1-3, or latest with all accessories as described in RDSO specifications. INSPECTION BY CONSIGNEE

1

53849

53849.29

... More
Supply of 24F straight joint enclosure (SJC) complete with all accessories as per TEC Specification TEC/GR/TX/OJC-002/03/APR/2010 or latest of reputed make like Raychem, Birla VXL, 3M, shakti or similar. INSPECTION BY CONSIGNEE

4

3599

14396.76

... More
Supply of Digital Earth Tester 0.01 to 99 Ohms. In 5 ranges 4 terminals type with all facilities WACO, Make - Metravi ERT-1501 (rechargeable) or similar. INSPECTION BY CONSIGNEE

18

17982

323685.36

... More
Circuit wiring/ Jumpering as per diagram in the relay rack/IDF rack/tag block. This 01 include preparation of jumper sheet duly checked by firm's site supervisor& wire to wire testing as per wiring diagram. Any wrong jumper done by wire man will be consider & payment for wrong jumper will not be done by the railway. Jumper wire & other material will be supplied by contractor. UNITMENTIONED AS PER UNIT TO BEREAD AS PER JUMPER

3000

14

44490

... More
Soldering of tag block, fixing and wiring of G type fuse, bus bar wiring per tag block as per approved plan, extant practice of WCR & as per instruction of site engineer (Solder wire, resin core, etc. material will be supplied by contractor) Unit- Tag block

78

210

16390.14

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts. This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

4100

21

86346

... More
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way 05 terminals block in the apparatus cases/point machine. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.

3120

42744

42744

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trenchless cabling in normal soil by machine . It includes supply. transportation and insertion of self lubricated 06 HDPE Pipe and laying of cables in boring under the track road plateform circulating area using By using self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore . The depth of horizontal boring should be minimum 3 mtr, from rail flange road level lground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63

840

900

756000

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, 07 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

4.2

83581

351041.29

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

0.5

-

59699.74

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

240

191

45849.6

... More
Cutting of all types of Roads prepratory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice

240

316

75938.4

... More
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractors own material.

770

823

634356.8

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.

40000

5

237600

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 13 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

13

9110

118433.77

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

456

75

34332.24

... More
Transporting & Supply and installation of cable route indicator at interval of 50 mtrs. in trenches along the cable route as per specification. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

40

1236

49452

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084

10

12560

125601.4

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case

10

1435

14352.4

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 18 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case

10

2028

20289.8

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 19 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case

10

1916

19166.3

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 20 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Appratus case full size

10

663

6631.8

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Single case.

10

283

2830.9

... More
Installation & fixing of earth electrode assembly including earth wire connected 22 through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing.

23

3539

81397.23

... More
Dismantling and releasing of Colour light signal, Location Box. Which includes 23 dismantling of signal fittings complete & location box fitting complete. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of JBP Div as per consignee.

11

1175

12928.19

... More
Dismantling and releasing of lifting barriers and its fitting etc. This includes complete removal & transport of lifting barrier. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of WC railway as per consignee.

3

3050

9152.25

... More
Installation of maintenance free Single Earth Pit which includes the following:- a) Excavation/ Auguring/ Boring of single earth pit of 100 mm to 125 mm dia to the depth of approx. 2.8 meter. b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed. c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 150x25x6mm. e) Carrying out exothermic weld connection on the 26 copper tape of 150x25x6mm on Earth Electrode for connecting two 35 sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0.5 m and run the 02 (two) 35 sq mm earth conductor (procured against supply item) from Earth pit to MEEB. h) Routing and termination of 02 (two) 35 sq mm 300x25x6 mm MEEB, which is to be fixed inside the equipment room with 02 (two) insulation studs, with stainless steel Nuts & Bolts. i) 300 X 300 X 300 mm (inside dimension) concrete Earth pit with a concrete lid, approx 50 mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and average resistance value shall be written in white paint.

2

9116

18232.96

... More
Termination of cable cores on ARA terminal/8-way/Wago/Phoenix terminals in the cable 27 termination rack. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

2400

12

29616

... More
Installation of powder coated Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars / relay frames for fixing of relay plug boards, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens' type or equivalent & as per extant practice on W.C. Rly. Typical 28 part list as per Annexure-H and Rack arrangement as per Sketch Nos Sk-727 and Rack plan as approved by Engineer incharge. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provided with PVC sleeve of proper size. Installation of Relay Rack Assembly including IDF pillars complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on W.C.Railway & the instructions of Rly. engineer at site.

2

1860

3720.46

... More
Plugging of Q series relay, Metal to Metal relay/relay groups. Energisation of the system, making the panel through, functional test as per control table with contractor's own mock 29 panel, break test if applicable to be done in presence of Rly. Engineers. This will include wiring alterations required if any at that stage, preparation and submission of wire count detail register etc. The work shall be done as per extant practice on W.C.Rly & the instruction of Rly engineer at site. All type of resistances, capacitors etc required for commissioning have to be provided by the contractor free of cost. Unit-Per rack

4

2071

8284.44

... More
Detailed testing of wiring including continuity testing, functional testing, selection table and locking table testing with simulation panel including making panel through in the presence 30 of Rly officials. The item includes wiring of simulation panels as per standard practice. Erection and wiring of simulation panels shall be with contractors own materials. Signal lamps required for simulation panel will be supplied by contractor. The contractor shall hand over the system for railways testing and shall arrange technical man power, wireman and supervisor to facilitate this testing by railway. UNIT- PER relay room

5

105730

528652.4

... More
Lettering & Numbering of detail and description writing of particulars of terminations & 31 equipments on relay rack, relays, cable termination rack, battery & power equipment's, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian" make or similar enamel paints or similar paint only to be used). This includes supply and fixing of teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site. Unit-per relay room

5

7394

36970

... More
Preparation & submission of cable route plan of main & tail cables, cable corage plan, location particulars, CT rack particulars, meggering report, earth resistance particulars, traction bonding diagram and any other drawing / particular required in Auto CAD in minimum A3 size Each 32 sheet should have a block for signature of Railway Officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK column. One complete set of tracings and four sets of copies of complete above detailed particulars / drawings along with one CD to be supplied by the contractor in thick plastic folder. UNIT- PER station

3

26490

79472.25

... More
Excavation, casting and plastering (above ground level) of main signal foundation as 33 per Drg.No.WCR/S&T/SIG/01 with contractor's own materials including cement and galvanised anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc. for casting of foundation will have to be brought by the contractor at his own cost.

7

10131

70920.99

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker board 34 , protective screen, blanking of ladder (0.6mm MS sheet) if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross- arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

7

3860

27025.6

... More
Termination of tail cable on main & auxiliary signal units and wiring with contractor 35 own material, fixing of LED signal units etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

7

1212

8487.43

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 36 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Apparatus case Half size

8

349

2794.16

... More
Installation, testing and commissioning of lifting barrier, complete with Casting of 38 cement concrete foundation for pedestal and boom rest post, cabling power supply connection & wiring with complete outdoor work.The work shall be done as per approved plan, extant practice on W.C. Railway & the instructions of Rly. Engineer at site.

2

15350

30700.98

... More
Alteration, wiring & testing of Control cum Indication Panel, KLR boxex, group phones, test boards etc. in connection with realy interlocking at existing station. This includes laying and termination of cables if any from panel room to relay room in GI/HDPE pipe.

1

29337

29337.29

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Half case as per Drg No JBP/S&T/C/085

2

12196

24392.66

... More
Erection of apparatus cases. This includes filling of location foundation with river bed sand and plastering on top of the sand. Half Case.

2

1098

2196.1

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 42 Railway Drawing including fixing of PVC coated string rods at the back side for cable support withcontractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Half Case.

2

1828

3657.02

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 43 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Half case

2

1333

2666.4

... More
Erection, Fitting and Rail connection of Track Lead Junction Box with contractor's fixing material and jacketed wire rope including 7mm single groove galvanized channel pin for track lead connection including angle of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes 44 in rails for track lead connections as per instructions of Rly engineer at site. PVC jacketed galvanized steel wire ropes of 6mm dia (7 x 19 strands) sheathed with PVC of 2mm wall thickness & over all thickness of 10mm for connection between the TLJB and the rails are to be used and to be supplied by the contractor. PVC sheath should b made of type 6 compound as per IS 5831 of 1970. Double wire ropes are to be connected between each rail and TLJB.

12

1710

20523.84

... More
Provision of bonding with contractor's materials including 7mm single groove 45 galvanized channel pin. This will include drilling of 7.2 mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site GI wires of 4mm dia (8 SWG) are to be used for jumpers across fish plates which should be supplied by the contractor free of cost.

200

226

45252

... More
Cement concrete work in the ratio of 1:3:6 with contractors own material as per instructions of site engineer. Unit - Cu. Meter

1

4231

4231.48

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 47 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Apparatus case Half size

2

435

871.78

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 48 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Shunt signal post with signal unit, surface base as per W.C.Rly standard practice.

2

194

388.94

... More
Lettering numbering of signals, point machine, track lead junction boxes, block joint, appratas cases etc ( each item to be taken as one unit )

10

60

609.6

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Half case

2

160

320.88

... More
Shifting of Existing apparatus case with foundation by crane or by other means upto 2- 51 20 Mtr decided as per site engineer. (During shifting of location boxes signalling gears disconnection by railway representative). This includes all type of labours charges and filling of locations foundation with river bed sand & plastering on top of the sand.

1

6533

6533.06

... More
Installation of Thermo- shrinkable joining kits for making (a) straight through joints without transformers for 6 quad Jelly filledcable (b) Derivation joint without transformer for 6 quad 52 jelly filled cable, and (c) Straight Through joint without transformer for 10Pr/20Pr.PIJF cables after jointingthe cable through test such as insulation test, Continuity cable losses etc. to be carried out jointly with the Railway Engineer. If any defect or any damage observed during jointing, the contractor should be redo the joint free of cost.

8

1232

9863.92

... More
Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own 53 splicing machine and tools. Joint should be prepared in such a way that the top of the enclosure shall be at a depthof 1.2 Mtr. and the enclosure should be covered with soft soil than bricks. AcceptanceTest procedure of WCR has to be followed for testing.Continuity of the OFC Armour should not be maintained.

4

4935

19742.24

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing enclosed) & filling with river sand & termite chemical after jointing work is done.

4

6158

24633.12

... More
Blowing and drawing of OFC through already buried HDPE duct , taking due care while transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge.

-

-

55

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 56 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

1

6233

6233.79

... More
Fixing of GI pipes for crossing the culverts, stone bridges etc. and concreting the ends with brick masonry at both ends as per the instructions of Rly. Engineer at site with Contractor's 59 materials. The brick masonry at the ends shall be done with well-burnt bricks &cement mixture of 1:3 ratios. (Supply ofGI pipes is not covered in this item). 3 perforation of 0.6mm dia per meter shall be made on the GI pipe as per the instructions of Engineer at site. This includes fixing with contractors own MS Channel, clamps of proper size etc as per instructions of engineer at site

60

62

3722.4

... More
Supply of Digital Axle Counter Single section type to cater for 4 detection points. monitoring 3 track sections Suitable for working with straight and continuous track section on straight line and suitable for IBS application. This item shall include Supply of final track clearance relay as 01 well as resetrelays for each section with accessories like detection points. track side electronics. deflector plates housing for track side electronics etc. This should include supply of LV boxes and Reset Boxes at the adjacent stations as per requirement of IBS stem. The Axle counter system should be as per RDSO specifications no. RDSO/SPN 177/2003 with latest amendment and latest version for Digital Axle counters & Manufacture's Specification and approved by RDSO/cross approved by RDSO. INSPECTION BY RDSO

1

1214393

1214393.43

... More
Supply of High availability Digital Axel Counter single section System complete withdual sensor as per RDSO Specification No.RDSO/SPN/177/2012 with version 3 consistingof 1. Track side High availability Digital Axel Counter unit DACF 720P-2 Nos. 2. High Frequency Tx Coil and 02 Rx coil (AD-711) (Each set consistsof web mounting type 2Nos. TX coil & 02 No RXcoil) - 02 sets 3. VitalRelay Box Model VR -722-02 nos. duly wired with following relay. a. vital relay QN1K, 24 V6F-6B - 02 Nos. b. Reset relay QN1K, 24 V 6F-6B -02 Nos. c. PR relay QNN124 V 6F-6B (Dual) - 01Nos. 4 Clamp with deflector plates and Hardware - 04 nos. 5.Reset Box Model No. RB259A - 02 Nos. 6. Surge Voltage protection device mounted on DIN rail - 02Nos. INSPECTION BY RDSO

1

678163

678163.7



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.