Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

West Central Railway - WCR Tender

Works
Electrical Goods and Equipments
Machinery and Tools
Electrical and Electronics
Ireps
Opening Date22 Jan 2025
Closing Date24 Feb 2025
Tender Amount₹ 2,70,76,466.09 
Notes
Download

Costs

Summary

S&t Work In Connection With Construction Of Rob/lhs Jabalpur-niwar Section Of Jabalpur Division On West Central Railway (signalling Work).

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of end stop suitable for disconnect terminal block INSPECTION BY CONSIGNEE

3140

15

47822.2

... More
Supply of Earth Electrode assembly as per drawing no S&T/CON/KOTA/Earthing/01. INSPECTION BY CONSIGNEE

36

1330

47907

... More
Supply of Apparatus cases with miniature E Type Locks with keys. (E Type Locks & keys as per spec. No IRS: S-30/64 & Drg. No. WCR/DY.CSTE(Con)/KOTA/3 with latest amendments). Single case as per. INSPECTION BY CONSIGNEE

24

20278

486672.48

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg.Nos. SA - 23748 Alt. 4 and Spec.Nos. IRS-S-75/2006 with INSPECTION BY RDSO

1000

198

198020

... More
Supply of Non-deteriorating type low voltage cartridge fuse rate current 2 Amp / 4 Amp in equal proportion round head type as per specification Nos. IRS/S/78/92 with latest amendment. INSPECTION BY RDSO

1000

85

85730

... More
Supply of PVC indoor cable 1x24x1 mm dia having colour coding of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

-

-

9

... More
Supply of PVC insulated railway signalling indoor single core [ tinned jumper wire] 1X 0 . 6 mm dia as per RDSO spec. Nos. IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

5

2695

13477.3

... More
Supply of PVC insulated flexible wire 16/ 0.2 mm dia as per RDSO spec. Nos. IRS:S- 76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

21

7565

158878.65

... More
Supply of Jumper wire 1X1mm dia as per RDSO spec, IRS:S-76/89 with latest amendments of various colours INSPECTION BY CONSIGNEE

16

8166

130661.44

... More
Supply of flexible cable single core multistrand copper conductors, 1x6 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

5

77238

386193.55

... More
Supply of flexible cable single core multistrand copper conductors, 1x2.5 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY CONSIGNEE

5

20651

103256.15

... More
Supply of Cable route locator/tracer set suitable for Detecting underground armoured 15 optic fiber cable (OFC] and signalling cables with LCD Graphic. Display active/passive modes and depth range. 3m to 10m. Make- RD8200G or Rycom Pathfinder ST LOC10 GPS equivalent INSPECTION BY RITES

2

450192

900385.16

... More
Supply of Clamp meter digital type with AC/DC clamp, three & three forth digit (3&3/4 digit) Model Metravi 4673/Uni-T 211B/Stanley SCM 222 or equivalent or better. INSPECTION BY CONSIGNEE.

4

22507

90031.4

... More
Supply of digital multi meter digital type, three & three forth digit (3&3/4 digit) Make Stanlay SMM 606 or Equivalent. INSPECTION BY RITES

12

46203

554446.08

... More
Supply of Digital insulation and continuity tester as per technical specifications attached INSPECTION BY CONSIGNEE

4

8997

35990

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . INSPECTION BY CONSIGNEE

69

4397

303435.09

... More
Supply of Electrically operated lifting barrier assembly as per RDSO spec. no. RDSO/SPN/208/2012 (Ver 2.0) with Amendment-1 or latest. Each consisting of 2 nos. electrically operated lifting barriers, 2 Pedestals, 2Nos. of 8 contract circuit controller with limit switch, hand cranks,2 electric motors 110 VAC 0.5 HP without centrifugal switch, 2 G.I Octagonal booms as per RDSO Drawing RDSO/S-11600 in 4 section of 8 feet long each, with 2 stop boards, boom light boxes, 20 MS. counter weights & 2 nos. of boom support for resting boom & boom resting assembly along with Gate Control Panel, indication panel on sheet metal fabricated box with switches and buttons to operate the gate as per Spec except (a) motor current is max. 5 Amps. for 0.5 HP motor & motor confirms as per spec (b) Wago terminal to be used instead of Elmex or M-5 terminals. (c) Circuit Controller should have CAM operated Siemens or Similar limit switches instead of wiping type contacts. Crank handle arrangement will be as per Rly. Requirement. The movement of the boom over 85 degrees to be restricted mechanically. INSPECTION BY RDSO

2

408384

816769.52

... More
Supply of Tag Blocks 200 way with cover as per IRS: S- 77/2006 (Rev. 1) with latest amendment and Drg Nos.SA-24751. INSPECTION BY CONSIGNEE

60

1794

107667

... More
Supply of QNA1 (AC immunised relay), 8F-8B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23 INSPECTION BY RDSO

90

5041

453708.9

... More
Supply of Time Element Relay (Clock work type) AG timer of Siemens Make (Nos RSSK 30/0052) or functional equivalent with timer range up to 120 seconds. INSPECTION BY CONSIGNEE

8

10189

81517.6

... More
Supply of Relay Non-AC Immune, plug-in-type, DC Neutral Line 60V 4F/4B, 5F/3B, 6F/2B contacts, front and back contacts metal to metal, conforming to IRS: S 46 and firm's specification. The relay housing shall contain two miniature identical relays in mini group housing complete with base plate, Siemens make (RSSK 30/0011)/ ABB or functional equivalent As per site requirement. INSPECTION BY RDSO

120

10037

1204464

... More
Supply of Relay Plug In type two DC neutral line in mini group housing, complete with 25 base plate consisting of Top relay AC immunized & Bottom relay both AC immunized, each 60V, 5F/3B, contacts, front and back contacts metal to metal conforming to IRS: S46 and firms specification. Siemens make (RSSK 30/0078-1), ABB or functional equivalent As per site requirement INSPECTION BY RDSO

60

11923

715397.4

... More
Supply of Relay Plug In type, two DC neutral line, mechanically interlocked, in mini 26 group housing, complete with base plate each 60V, 4F/4B contacts, front and back contacts metal to metal conforming to IRS: S 46 and firms specification. Siemens make (RSSK 30/0012) ABB or functional equivalent As per site requirement INSPECTION BY RDSO

30

10600

318023.4

... More
Supply of lamp holder switches, two pin for location box make anchor or equivalent. INSPECTION BY CONSIGNEE

6

102

617.1

... More
Supply of PVC indoor cable 1x60x0.6 mm dia having colour coading of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

1.5

252814

379221.18

... More
Supply of PVC indoor cable 1x40x0.6 mm dia having colour coading of insulation of inner core shall be four colours viz. Yellow, White, Pink & Voilet and shall be confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO

1.5

184031

276047.21

... More
Supply of ARA Terminal Block made of PBT as per Drg No SA 23741 alt 3 & spec. No IRS S 75/2006 with latest amendments with disconnecting links. INSPECTION BY RDSO

1000

115

115750

... More
Supply of QNA1K (AC immunized relay), 6F-6B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS: S34 & IRS: S23. INSPECTION BY RDSO

30

3628

108855.3

... More
Supply of Relay Rack Assembly Complete With Scaffolding, Fixtures and accessories 32 including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket,11 Way Bus Bars with cover and mounting brackets, runway for cable/wires frame base assembly etc. Siemens type & as per extant practice on C.Rly. Typical part list as per Annexure and Rack arrangement as per Sketch no SK -727 and Rack plan as approved by Engineer incharge. INSPECTION BY CONSIGNEE

3

43454

130362.87

... More
Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance 35 measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 -49 : 1.5% Also measure current leakage up to 20A. No spines required for measurement. Model - CET 500 or equivalent / higher version make: Stanlay. INSPECTION BY RITES

4

89012

356049.32

... More
Supply of MEGGER : Analog-Digital insulation and continuity tester as per technical specifications attached INSPECTION BY CONSIGNEE

32

8761

280368

... More
Supply of basic material to construct Unit Maintenance Free Earth consisting as per RDSO Spec No. RDSO/ SPN/ 197/2008 (or with latest Amend) consisting of : a) Copper bonded steel 37 electrodes of 3.0 m long, 17.2 mm dia with copper bonding thickness of min 250 micron and UL listed and marked - 1 No. b) Earth Enhancement compound of approved brand supplied in sealed bags of min 10 Kgs - 3 Nos. c) Copper Strip of 150 x 25 x 6mm to terminate Earth Rod - 2 No. d) Copper Strip of 300 x 25 x 6mm (MEEB) - 1 No. Procurement should be done by RDSO approved source. INSPECTION BY CONSIGNEE.

12

18729

224758.56

... More
Soldering of tag block, fixing and wiring of G type fuse, bus bar wiring per tag block as per approved plan, extant practice of WCR & as per instruction of site engineer (Solder wire, resin core, etc. material will be supplied by contractor) Unit- Tag block

152

210

31939.76

... More
Detailed testing of wiring including continuity testing, functional testing, selection table and locking table testing with simulation panel including making panel through in the presence of Rly 06 officials. The item includes wiring of simulation panels as per standard practice. Erection and wiring of simulation panels shall be with contractors own materials. Signal lamps required for simulation panel will be supplied by contractor. The contractor shall hand over the system for railways testing and shall arrange technical man power, wireman and supervisor to facilitate this testing by railway. UNIT- PER station/IBS

6

105374

632247.84

... More
Design and supply of Detailed Signalling Circuits including panel diagram (if required) 07 in A3 size, Completion circuit shall be ploted in Autocad. The contractor shall initially supply 2 Sets ofcircuits duly signed by the circuit designer having substantial experience on design side for making such circuits , complete for approval of Railways. Railway will return one set of circuit to the contractor duly approved with alterations/ corrections, if any. The contractor shall incorporated Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 4 sets of final approved circuits (out of which one set shall be supplied in transparent polythene bags. Only two sheets of cicuits shall be placed in one polythene bag/cover each) shall be submitted to the Railways in case there are no further alteration suggested by Railways.

9

100064

900580.41

... More
Fixing of ARA /WAGO Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site.

6000

24

144240

... More
Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way 09 terminals block in the apparatus cases/point machine. This includes all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.

8500

153085

153085

... More
All work pertaining to Horizontal Dirctional Drilling (HDD)/Boring and trenchless cabling in normal soil by machine . It includes supply. transportation and insertion of self lubricated HDPE 10 Pipe and laying of cables in boring under the track road plateform circulating area using By using self lubricated HDPE Pipe of 120mm outer dia and 103.5mm inner dia in the bore . The depth of horizontal boring should be minimum 3 mtr, from rail flange road level lground level as per site requirement and as per instructions of Railway Engineer incharge. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63

2020

1928

3894580.2

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, 11 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

7.6

92718

704658.17

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

1.6

132451

211923.15

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

660

211

139873.8

... More
Cutting of all types of Roads prepratory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice

660

351

231660

... More
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractors own material.

2120

913

1937468

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.

68000

6

448120

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 17 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

46

10106

464885.66

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

-

-

18

... More
Transporting & Supply and installation of cable route indicator at interval of 50 mtrs. in trenches along the cable route as per specification. The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

130

1236

160719

... More
Excavation, casting and plastering (above ground level) of Apparatus case foundation with contractors own Metal Sheet frame, cement, anchor bolts and other materials. Single case as per Drg No JBP/S&T/C/084

30

14331

429950.4

... More
Erection of apparatus cases.This includes filling of location foundation with river bed sand and plastering on top of the sand. Single case

30

1637

49130.4

... More
Fabrication and fixing of phenolic board in location box by providing all fixtures as per 22 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Single case

30

2315

69454.8

... More
Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring 23 material. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 394 of 1990 or latest. Single case

30

2186

65608.8

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following 24 items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per WCR practice. Appratus case full size

30

663

19895.4

... More
Lettering numbering termination particulars, equipments names etc legibly and neatly inside location boxes. Single case.

30

402

12073.8

... More
Installation & fixing of earth electrode assembly including earth wire connected 26 through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing.

32

3925

125628.48

... More
Dismantling and releasing of Colour light signal, Location Box. Which includes dismantling of signal fittings complete & location box fitting complete. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of JBP Div as per consignee.

44

1175

51712.76

... More
Dismantling and releasing of lifting barriers and its fitting etc. This includes complete removal & transport of lifting barrier. All dismantelled materials to be transported and stacked in the store of SSE/Sig/M/JBP or any other store of WC railway as per consignee.

13

3050

39659.75

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete 29 with Casting of cement concrete foundation for pedestal and boom rest post, cabling power supply connection & wiring with complete outdoor work.The work shall be done as per approved plan, extant practice on W.C. Railway & the instructions of Rly. Engineer at site.Testing and commissioning is to be done by OEM Engineer.

3

13468

40404.39

... More
Installation of Track device of SSDAC/MSDAC (Double rail contact of digital Axle counter) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to location box /terminations, Fixing of deflector plates.(Double Walled 30 antirodent corrugated pipe made up of high density Polyethelene of required dia and all other accessories as per site requirement to be supplied by the firm).Casting of foundation for track side housing & erection of track side housing.Installation & Wiring & commissioniing of EJB, Reset box, track side electronic inside the track side housing including supply of wires and other accessories for complete instalation.

8

14423

115387.12

... More
Installation of powder coated Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars / relay frames for fixing of relay plug boards, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base 31 assembly etc. Siemens' type or equivalent & as per extant practice on W.C. Rly. Typical part list as per Annexure-H and Rack arrangement as per Sketch Nos Sk-727 and Rack plan as approved by Engineer incharge. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provided with PVC sleeve of proper size. Installation of Relay Rack Assembly including IDF pillars complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on W.C.Railway & the instructions of Rly. engineer at site.

3

1860

5580.69

... More
Termination of cable cores on ARA terminal/8-way/Wago/Phoenix terminals in the cable 32 termination rack. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

1200

12

14808

... More
Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating 33 panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian" make or similar enamel paints or similar paint only to be used). This includes supply and fixing of teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site. Unit-per relay room

3

7394

22182

... More
Preparation & submission of cable route plan of main & tail cables, cable corage plan, location particulars, CT rack particulars, meggering report, earth resistance particulars, traction bonding diagram and any other drawing / particular required in Auto CAD in minimum A3 size Each 34 sheet should have a block for signature of Railway Officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK column. One complete set of tracings and four sets of copies of complete above detailed particulars / drawings along with one CD to be supplied by the contractor in thick plastic folder. UNIT- PER station

4

26490

105963

... More
Excavation, casting and plastering (above ground level) of main signal foundation as 35 per Drg.No.WCR/S&T/SIG/01 with contractor's own materials including cement and galvanised anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc. for casting of foundation will have to be brought by the contractor at his own cost.

2

10131

20263.14

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker board , 36 protective screen, blanking of ladder (0.6mm MS sheet) if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross- arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.

2

3860

7721.6

... More
Termination of tail cable on main & auxiliary signal units and wiring with contractor 37 own material, fixing of LED signal units etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site.

2

1212

2424.98

... More
Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian 38 paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.Appratus case Half size

2

349

698.54

... More
Installation of maintenance free Single Earth Pit which includes the following:- a) Excavation/ Auguring/ Boring of single earth pit of 100 mm to 125 mm dia to the depth of approx. 2.8 meter. b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with 40 sledge hammer where the natural soil is assumed. c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 150x25x6mm. e) Carrying out exothermic weld connection on the copper tape of 150x25x6mm on Earth Electrode for connecting two 35 sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0.5 m and run the 02 (two) 35 sq mm earth conductor (procured against supply item) from Earth pit to MEEB. h) Routing and termination of 02 (two) 35 sq mm 300x25x6 mm MEEB, which is to be fixed inside the equipment room with 02 (two) insulation studs, with stainless steel Nuts & Bolts. i) 300 X 300 X 300 mm (inside dimension) concrete Earth pit with a concrete lid, approx 50 mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and average resistance value shall be written in white paint.

10

9116

91164.8

... More
Supply of Digital Axle Counter Single section type to cater for 4 detection points. Monitoring 3 track sections Suitable for working with straight and continuous track section on straight line and suitable for IBS application. This item shall include Supply of final track clearance relay as 01 well as reset relays for each section with accessories like detection points, track side electronics, deflector plates, housing for track side electronics etc. This should include supply of LV boxes and Reset Boxes at the adjacent stations as per requirement of IBS system. The Axle counter system should be as per RDSO specifications no. RDSO/SPN/177/2012 ver 3.0 with latest amendment and latest version. INSPECTION BY RDSO

3

1214393

3643180.29



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.