MP State Livestock And Poultry Development Corporation Tender

... More
The MPLPDC has issued a formal invitation for competitive bids for the MP State Livestock And Poultry Development Corporation project, for 159/151/kiratpur, Itarsi/2021-22 in Hoshangabad, Madhya Pradesh, with an estimated contract value of Rs. 24,96,879. The bid opening date for this tender is 10-04-2021 and the last date for bid submission is 20-04-2021. Interested bidders for MP State Livestock And Poultry Development Corporation tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

MP State Livestock And Poultry Development Corporation - MPLPDC Tender

Works
Electrical and Electronics
Eprocure
Opening Date10 Apr 2021
Closing Date20 Apr 2021
Tender Amount₹ 24,96,879 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 50,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 295

Summary

159/151/kiratpur, Itarsi/2021-22

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Collection and spreading of metal dust, murum and 40mm graded hard metal in sub-station yard or as required as mentioned below -Metal dust (SOR I.No. 42.88.1)

4

-

897

... More
Supplying and fixing 33/11/0.4 KV enamel coated danger board size 200x250mm with clamp on existing HT/LT structure / poles.(SOR I.No. 42.68)

5

-

158

... More
With 3 metre pipe of 80mm outer dia., 40mm inner dia and 14mm terminal dia. In soft/hard rock/marshy soil with 50 kgs. (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.. (SOR I.No. 37.40.4)

10

-

20652

... More
Supply, installation, testing & commissioning of HT trivector energy meter, 3 phase 4 wire, 110 Volts, 5 Amp, accuracy class 0.5S with GSM (GPRS compatible) intelligent modem for consumer (store N forward type) suitable for required C.T. including uPVC box/sheet metal box with TTB duly tested from electricity board. (SOR I.No. 42.119)

1

-

19801

... More
Prima coat with aluminium paint, brushing complete with material and labour including preparation of surface SOR I.No 34.4.3

150

-

76

... More
Supplying and erection of 33kV Porcelain pin insulatorcomplete with long steel head G.I. pin, nut, washer etc. as required(SOR I.No. 42.45)

12

-

570

... More
Supply of shock instruction chart duly framed with glass, as reqd.(42.83)

2

-

300

... More
Supplying and laying 25mm X 5mm G.I. strip at 0.5 Metre below ground level as strip earth electrode including soldering etc. as required. (SOR I.No. 37.9)

200

-

83

... More
(SOR I.No.27.8.4.4)MCB FP 50Amp to 63 Amp 10kA rating

3

-

1348

... More
Supply of XLPE Insulated power cable (confirming IS-7098 Part-I ) 1100 Volt grade, 1 core /2 core /3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor 3½ CORE ARMOURED 300 Sq.mm (SOR I.No. 41.1.8.8)

24

-

1054

... More
capacitor panel: incoming 200 A SFU with hrc link indicating lamp for RYB indication with hrc protection microprocessor based APFC relay rmi-7 with didital pf indication voltage & current indication with ct bus bar set ofv suitable for 250 ampere al bus bar suported with epoxy insulator and insulated and pvc sleeves outgoing 2,3,5,10,15,25KVAR capacitor bank (1no.) compartment spares for future required up to 60 kvar capacitor bank feeders protected and future required up to60 kvar. with suitabke fuselinks & contractor type MNC32C( suitable for 25kvar) start stop push button on indication automanual selector switch with control fuse. discharge time(0-60 sec) circuit for capacitor bank in manual mode operated withaccesories. cabing shallbe flxible color coded cu cable of suitable size shall be used with proper terminations using lugs & sleeves for all the powe r & control connection through pvc channel & spiral where ever necessary double earthing strip shall be provided at both ends( SORI- NON SOR ITEM)

1

-

170000

... More
Supply, fabrication and erection of Angle/Chanel/Flat iron fitting for over head line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, Back/Support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification.(SOR I.No. 42.41)

1200

-

78

... More
Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per specification. (SOR I.No. 42.66)

5

-

116

... More
Supplying and drawing guard wire/earth wire/bearer wire 13mm2 (4mm. Dia) G.I. including stringing, binding at existing insulators or brackets, jointing, jumpering, connecting & cradle etc. as required and clearing of obstacles (if any) (SOR I.No. 42.8)

0.3

-

10519

... More
MCB SP 6Amp to 32Amp 10kA rating(SOR I.No.27.8.1.2)

3

-

136

... More
Supply & fixing fencing of chain link mesh 100 x 100 mm,12 SWG GI wire for for D.P. structure electric sub-stationincluding single post of angle iron size 50x50x5mm, 2.5 mtlong should be provided up to 2.00 mt. apart or as required.The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel,shall be erected between the post. The angle iron post shallbe erected in cement concrete 1:2:4 ( 20 mm graded metal )foundation, including excavation of pit and refilling the same. The fencing shall be provided with one entrance gateincluding locking arrangement as required as perspecification. The height of fencing shall be 2 mt. aboveground level. Fencing shall be painted with required shade. (SOR I.No. 42.74)

100

-

1296

... More
Murum (SOR I.No. 42.88.2)

4

-

629

... More
Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor.Armoured 12 core2.5 Sq. Mm.(SOR I.No 41.4.7.1)

25

-

295

... More
Laying of one number armoured / unarmoured cable 1.1.KV grade of size exceeding 120 sq. mm. but not exceeding 400 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, and sand cushioning protective covering and refilling the pit etc. as required.(SOR I.No. 41.17)

780

-

220

... More
Supplying installing, testing & commissioning of outdoor H.T., AB switch assembly set gang operated with brass contact parts, including required GI pipe operating rod, handle & locking arrangement on On-Off position conforming to IS complete with required material and installing on existing DP structure to complete the job as required as per specification.(Set of 3 nos.) 33 kV, 600A.(SOR I.No. 42.61.2 )

1

-

20289

... More
Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete150.00mm (SOR I.No. 41.12.1.10)

15

-

1745

... More
Supplying installing, testing & commissioning D.O. fuse assembly with brass part contact for 33 or 11/0.4 KV DP Structure set of 3 Nos. with fuse barrel i/c required fuse element & other materials as per specification on existing D.P. structure as required.33kV, (SOR I.No. 42.62.12)

1

-

13841

... More
Supply of support for overhead line RS joist /'H' Beam of I.S. standard including drilling of required hole etc. complete as required. H - Beam 152 x 152mm, Std weight 37.1 Kg / Mtr (SOR I.No. 42.2.6)

78

-

1882

... More
Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececification Digital Ampere Meter with CTs with selector switch (SOR I.No. 29.28.1)

2

-

1773

... More
Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with Micro- Processor release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2SMCCB 36kA current rating - 160Amp 3Pole µ-processor release, over load40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable MCCB 160A, 36kA, 3P(SOR I.No. 27.4.5)

2

-

8318

... More
MCCB 36kA current rating - 250Amp 3 Pole µ-processor release, over load 40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable MCCB 400A, 36kA, 3P(SOR I.No. 27.4.7)

1

-

10569

... More
MCCB 36kA current rating - 400Amp 3 Pole µ-processor release, over load 40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable MCCB 250A, 36kA, 3P(SOR I.No. 27.4.6)

2

-

14456

... More
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good.180mm(SOR I.No 41.14.6)

30

-

277

... More
MCCB 36kA current rating - 315Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 3 Pole MCCB 315A,36kA, 3P(SOR I.No. 27.2.8)

1

-

13857

... More
Supplying and erection of single piece non-linear resistorpolymer type lightning arrestor (Set of 3 Nos.) for 3 wire,33kV overhead lines/ sub-station with rated voltage of 27kV(rms) with a nominal discharge current rating of 10 KA andcomplete with galvanized clamping arrangement, G.I. bolts,nuts, washer etc. as required. (SOR I.No. 42.60)

1

-

33444

... More
Duly refilled 4 Kg ABC type duly refilled 4 Kg &ready to use (SORI-42.76.1)

2

-

2900

... More
4 buckets set with sand, self-supported M.S. stand i/c shed duly painted with red colour as per IS.(42.76.5)

1

-

3900

... More
Painting of poles Prima coat over new steel and other metallicsurface with red oxide zinc chromide paint complete with supply of material labour etc.including preparation of surface.SOR I.No 34.4.2

150

-

63

... More
Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececification LED lamp indicators (SOR I.No. 29.28.6)

8

-

182

... More
Supply of fiber D.O operating rod for 11/33KV tested (42.81)

2

-

2350

... More
Supplying & fixing of fire extinguisher/refills as per IS specificationDuly refilled 6 Kg ABC type duly refilled 6 Kg & ready touse(SORI-42.76.1)

2

-

3200

... More
Erection of RS Joist pole / 'H' Beam / steel tubular / steel rail pole of length exceeding 10 metres but not exceeding 13 metres in cement concrete M-10 (1 cement:3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required. (SOR I.No. 42.19)

6

-

4162

... More
Digital Volt Meter with selector switch & HRC fuse (SOR I.No. 29.28.2)

2

-

1909

... More
Laying of one number armoured / unarmoured power cable 1.1 KV grade of size exceeding 120 sq. mm but not exceeding 400 sq. mm. in the existing RCC Hume /Stone ware/G.I. Pipe/surface in existing trench as required.(SOR I.No. 41.23)

30

-

40

... More
Supplying and erection of a set of four 11KV porcelain disc insulators for 33KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts, washers etc. as required.(SOR I.No. 42.47)

3

-

1979

... More
Establishment of 100 KVA electrical connection at NKBC, Kiratpur, Itarsi

-

-

-

... More
Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any) 0.1 sq inch (100 Sq.mm Al. EQ. ) - (Dog) (SOR I.No. 42.5.4)

0.5

-

72079

... More
Supplying, fixing, testing & commissioning wall / floor mounted LT Panel primer coated with powder coated paint & provided with required gasket for dust / vermin proof withdegree of protection IP42 suitable for 415V 3 phase, 50 Hz,4 wire system fabricated out of CRCA sheet up to 2 mmthick (1.6 mm for doors) duly compartmentalized forincomer, bus section, outgoings, cable alleys & CT, PTAmpere Meter, Volt Meter, selector switches, Frequency Meter, phase indicating lamps, Energy Meter complete including cost of busbar supports, detachable cable glandplates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs , ACB, panel mountedChangeover switch / SFUs, etc. as required but excluding cost of bus bar strips, Ampere Meter, Volt Meter, Selector switch as per approved design & specification(SOR I.No. 29.27)

500

-

320

... More
Supply of XLPE Insulated power cable (confirming IS-7098 Part-I ) 1100 Volt grade, 1 core /2 core /3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor 3½ CORE ARMOURED 150Sq.mm (SOR I.No. 41.1.8.7)

780

-

547

... More
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-MCB TP For 40Amp 10kA rating(SOR I.No.27.8.4.3)

3

-

1318

... More
Supply, laying and fixing of G.I. earth coil of 4mm dia G.I. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification.(SOR I.No. 42.67)

7

-

229

... More
Supplying, installing, testing and commissioning of 33/0.4 K.V. 3 Phase 50 Cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side andstar on L.T. side, hand operated off load Tap changerswitch, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge drain valve with plug, temperature not exceeding 50ºC on load, temperature dial gauge, bucholz relay, oil conservator with drain plug, oil filling hole with plug, dehydrating silica gel breather on eyelevel, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable boxon LV side, first filling of oil up to desired level and transformer installing on existing structure with all required materials arrangements as required as per IS specification. Marked ISI & level 3 Copper wound 200KVA(SOR I.No. 42.70.2.2)

1

-

437728

... More
Supplying and erection of stay set complete with 19/20mm.dia 1.8 metre long stay rod, turn buckle, ancher plate of size 300mm x 300mm x 7.5mm, thimble, stay clamps, bow tightener, 7/4.00 dia G.I. stay wire etc. in cement concrete M-10 (1 Cement : 3 Coarse and : 6 granded stone aggregate 40mm nominal size) foundation including excavation and back refilling etc. as required.(SOR I.No. 42.25)

6

-

3372

... More
Supply of hand gloves 33KV tested(42.79)

2

-

830

... More
Supply of rubber mat 2 x 1.0Mtr, 1100V tested(42.77)

3

-

1400

... More
Designing and construction of Pedestal (Plinth) fortransformerof desired size including excavation in hard rock/soft rock, base concrete 1:4:8, 20mm thick and pedestal of RCC 1:2:4 including required tar steel reinforcement for required height as per IE Rules from base concrete including shuttering and finishing with 10mm thick plaster in cement mortor 1:3 curing & white washing etc. complete as per specifications.(SOR I.No. 42.87)

15

-

7495



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.