MP Power Transmission Company Limited Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
MP Power Transmission Company Limited - MPPTCL Tender
Civil And Construction
Civil Works Others
Electrical and Electronics
Eprocure
Opening Date9 Jan 2024
Closing Date30 Jan 2024
Tender Amount₹ 13,20,000
Costs
EMD
₹ 26,400Document Cost
₹ 1,180Tender Fee
₹ 295
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MPPTC_325040_1Bid Award Id
ViewTender No
1673Tender Authority
MP Power Transmission Company Limited ViewPurchaser Address
-Website
http://https://mptenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Providing and installation of high mast lighting structure with construction of foundation etc. at MPPTCL Store Itarsi, Gwalior and Work Shop Sehore under EHT-C Circle Bhopal.
BOQ Items
3004929,5.16.6(SOR w.e.f 01.12.2020),Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification")Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786
2520
158508
62.9
3004924,5.16.1(SOR w.e.f 01.12.2020),Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification") : Mild steel and Medium Tensile steel bars.
330
19800
60
3004893,5.9.1(SOR w.e.f 01.12.2020),Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level
67
12770
190.6
3004894,5.9.2.1(SOR w.e.f 01.12.2020),Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel.
129.6
28382
219
3004884,5.1.1(SOR w.e.f 01.12.2020),Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete
36.2
209815
5796
3006147,13.2.2(SOR w.e.f 01.12.2020),15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 sand)
12
1776
148
3004792,2.24(SOR w.e.f 01.12.2020),Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6
432
72
3000102,4 NSOR,Supply , filling & compaction of Moorum with boulders / Copra with boulders below yard structure foundations in black cotton soil strata including cost of all material, labour, T&P, taxes, royalty, transportation, watering etc. complete as per direction of Engineer in charge.
6
2292
382
3004683,1.2.2 (SOR w.e.f 01.12.2020),Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre. Earth
3
200
66.78
3004602,1.1.2.1 (SOR w.e.f 01.12.2020),Transportation By Mechanical Transport including loading, unloading and stacking. Earth 1 km
3
418
139.47
3000114,16 NSOR,Labour only for fixing bolts of any length i/c weight of nuts & washers , etc. complete as per direction of Engineer in charge.
150
1200
8
1003694,NSOR,4 CORE 2.5 Sqmm aroured (MPPTCL SOR)
660
59532
90.2
2000100,Cable Laying 4Core x 2.5 Sqmm Armd,Laying of 4Core 2.5 Sq.mm Armoured CopperCable on racks/ cable trays/ angle support overhead racks conduits including dressing of cables with accessories for copper conductor & armoured control cables,multistand (MPPTCL SOR)
660
11880
18
2000086,Cable Termination 4Core x 2.5 Sqmm Armd,4Core x 2.5 Sq.mm.(Armoured) Cable terminations including fixing of cable glands, lugs etc. for each type of control/ power cables, including terminations at both ends. I.R. value between cores and I.R. value with respect to its armouring is to be verified. The continuity of all cores is also to be verified. Both work to be done before connecting cable to the terminal block. Making suitable hole in bottom/side plate of C&R panel, AC/DC Board, Marshaling box, CT/PT sec box and CB mechanism box for fixing cable glands in addition to cable gland holes already provided. The hole should be free from burrs. Fixing all cables in respective cable glands and refixing gland plate to its original place. All cable identification plate is to be provided on both ends of each cable. Stripping of outer insulation cover , armouring etc. of cable, fixing ferrules on each core at both ends. Stripping all cores to suitable length, making eye, crimping terminal lugs (as the case may be ) and fixing it to terminal block as per drawing followed by proper bending/ dressing of all cores.Cable Terminations at Both Ends for Cable (MPPTCL SOR)
12
2160
180
3010395,42.95 SOR PWD wef 01.12.2020 Electrical,"Providing and erection on existing foundation12.5 meter high mast lighting system suitable to install 6 No. 2 x 400 w M.H/S.V/LED flood light fitting and control gear with integral Power tool, weight 340 kg. comprising of 2 section of hot dipped galvanized materials as per BSEN ISO 1461 thickness 3 mm, dia 100mm & 360mm for top and bottom respectively, stress fitting arrangement on site with 350mm overlap dynamic loading to withstand max wind pressure as per -IS 875 part III, parameters for structural & foundation design must be taken from wind tunnel test. Lightning protection of GI single spike 800mm at top and at base inside compartment with double internal lock with adequate size of MCB erected on PVC board complete with base plate of 25mm thick 520mm dia. and foundation bolts having 4 nos. bolts of 24mm dia, 750mm long (EN8 grade), Anchor plate 445 PCD, including accessories viz..(1) Lantern carriage of 50 NB ERW class-B, MS pipe covered with PVC sleeve suitable to carry 250kg. load and upto 6 fittings symmetrically..(2) Trailing copper cable 5x2.5 sq.mm,.EPR insulated PCP sheathed..(3) Double drum/350kg winch having gear 53:1, oil bath (SAE90/140) arrangement..(4) 2 nos. stainless steel wire ropes 5mm dia (7/19) breaking load capacity 1450 kg.x 2..(5) Integral power tool 3-phase, 0.75 HP 2m/min single speed..(6) Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming MCB 32 A TPN switch, HRC fuses, single dial timer, suitable size of contactors for lighting and power tool, 2 nos. outgoing, reversing switch for motor..(7) Foundation drawing, test certificate and guarantee certificate shall be provided by manufacturer. (without fixture and lamp)"
6
750294
125049
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements