Airports Authority Of India Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Airports Authority Of India - AAI Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Apr 2025
Closing Soon2 May 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
0.8 mm sheet duct

50

-

-

... More
0.63 mm sheet duct

80

-

-

... More
INSULATION WORK Supply & Installation of Thermal Insulation on Duct using Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 Kg/m3 (Minimum), Thermal Conductivity as per ASTM / EN standard and with Factory Laminated Aluminium Foil of 60 microns using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete as per Specifications. 16mm thick Class O Nitrile Rubber Insulation with Alu Foil of 60 microns

180

-

-

... More
Supply, Installation and Testing of multiblade box type GSS construction of volume control damper, to be provided with suitable links and quadrants for control of volume of air

18

-

-

... More
Supply, Testing & charging of VRF system with Additional Eco-friendly Refrigerant Gas (Honeywell/Dupont)

850

-

-

... More
Supplying, fixing, testing and commissioning of Balancing Valve with built in measuring facility with CI body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 150 mm dia

2

-

-

... More
Providing & fixing of C.I double flange suction " Y" type strainer fabricated out of minimum 1.6 mm thick Stainless Steel sheet with 3 mm dia. perforation holes with stainless steel flange including nuts, bolts and 3 mm thick rubber insertion complete & tested to 16 Kg/Sq.cm pressure complete as required and as per tender specification. 65 mm dia

4

-

-

... More
Supply, Installation, testing and commissioning of Pressure independent type 2 way Balancing and modulating Control valves in a single Unit of Valve along with Digital thermostat & its connecting wiring. PN10 Rating. DN 15 to DN 32 in Brass Body Ext. Threaded, DN 40 & DN 50 in Cast Iron Body, Ext. Threaded DN 65 to DN 100 Cast Iron body, flanged connection Duly mounted with Modulating actuator IP42/54. Accordingly type suitable for 24V/230V AC. As per specifications of following sizes:

-

-

-

... More
125 mm

2

-

-

5

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly Valve (Mannual) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified., strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.

-

-

-

... More
250 mm dia

2

-

-

... More
150 mm dia

4

-

-

... More
125 mm dia

6

-

-

... More
100 mm dia

12

-

-

... More
65 mm dia

8

-

-

... More
Providing and fixing following size ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.

-

-

-

... More
50 mm nominal bore

10

-

-

... More
25 mm nominal bore

18

-

-

... More
Supply, Installation, testing and Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/harddrawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required :

-

-

-

... More
44.40 mm dia(OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

432

-

-

... More
31.60 mm dia(OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

98.5

-

-

... More
25.20 mm dia(OD) (Hard drawn) with tube thickness 1.20 mm with 19 mm thick insulation

432

-

-

... More
SITC of Powder coated extruded aluminium construction square / round shape supply air diffusers with removable core & anti smudge ring & volume control dampers as per approved drawings and specifications.

150

-

-

... More
SITC of Powder coated extruded aluminium construction. Square / round shape return air diffusers with removable core, antismudge ring & without volume control damper as per specifications.

150

-

-

... More
SITC of Powder coated extruded aluminium construction Linear Grilles with removable core as per approved drawings and specifications.

80

-

-

... More
INLINE FAN WITH SPEED REGULATOR Supply, Installation, Testing and Commissioning of Inline Fan with direct/belt driven motor, belt guard, motor mount & vibration isolation type mounting. Casing shall be of 14 gauge steel sheet with min. 20 mm thick motor mounting plate. Vanes shall be Aerodynamically designed for max.efficiency the casing shall be bonderized, primed & coated with enamel paint. Hub & blades will be of Aluminium, blades shall be Aerofoil section for max. efficiency. Max clearance between blade tip & fan housing shall be 5 mm. The blade shall be tested at speed of 25% above the design operation speed. Motor shall be IE3 415/220 + 10% volts, 50 cycles,3 phase with class F insulation. Max. speed of motor shall be 1500 RPM, complete as per specifications & drawings. Fan should be complete with fire retardant, water proof double flexible connection between fan & duct.

-

-

-

... More
Capacity: 900 CFM Minimum Static Presure : 20 mm Of wg

2

-

-

... More
Capacity: 1800 CFM Minimum Static Presure : 39 mm Of wg

2

-

-

... More
Installation, testing and commisioning of 11 TR treated fresh Air Unit (indoor + Outdoor) at ceiling with necessary arrangement of fixing work, etc. as required.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.