Power Development And Non Renewable Energy Tender

... More
The Power Development And Non Renewable Energy has issued a formal invitation for competitive bids for Supply Installation Testing And Commissioning For Creation Of Distribution Substations in Leh, Ladakh, with an estimated contract value of Rs. 2,71,68,000. The bid opening date for this tender is 15-05-2025 and the last date for bid submission is 26-05-2025. Interested bidders for Power Development And Non Renewable Energy tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Power Development And Non Renewable Energy Tender

Works
Electrical Works
Eprocure
Opening Date15 May 2025
Closing Date26 May 2025
Tender Amount₹ 2,71,68,000 
Notes
Download

Costs

Summary

Supply Installation Testing And Commissioning For Creation Of Distribution Substations

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply Installation Testing and Commissioning for Creation of Distribution SubStations at various locations of Leh District Spituk Shey and Upper Section on full turnkey basis under SDP 2025 26
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

7

1

7

... More
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

1

1

1

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

14

1

14

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

14

1

14

... More
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs

616

1

616

... More
9 Mtr. Long Pole,ST-410 SP33)

28

1

28

... More
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

42

1

42

... More
GI Channel/Angle/Flat of sizes including clamps

4200

1

4200

... More
Galvinized Nuts and Bolts.

112

1

112

... More
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

42

1

42

... More
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm

42

1

42

... More
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions

5

1

5

... More
LT Distribution Box for 200 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (200KVA) and suitable MCCBs for outgoing circuits with terminal extensions

1

1

1

... More
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp (63/100/250KVA) and suitable MCCBs for outgoing circuits with terminal extensions

7

1

7

... More
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 100Amp and suitable MCCBs for outgoing circuits with terminal extensions

1

1

1

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

28

1

28

... More
Wedge Connectors/PG Clamps

84

1

84

... More
Danger Plates with Clamps

14

1

14

... More
GI Barbed Wire for Anti Climbing

234

1

234

... More
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole

28

1

28

... More
Painting of Poles Red Oxide

28

1

28

... More
Painting of Poles Aluminium Paint

28

1

28

... More
Sundry items like aluminium lugs, jumper binding Tape

14

1

14

... More
Transformer Fencing

9

1

9

... More
Installation/Testing/Commissioning Part)

-

-

-

... More
250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

5

1

5

... More
200 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

1

1

1

... More
100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

7

1

7

... More
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

1

1

1

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

14

1

14

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

14

1

14

... More
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs

616

1

616

... More
9 Mtr. Long Pole,ST-410 SP33)

28

1

28

... More
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

42

1

42

... More
GI Channel/Angle/Flat of sizes including clamps

4200

1

4200

... More
Galvinized Nuts and Bolts.

112

1

112

... More
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

42

1

42

... More
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm

42

1

42

... More
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions

5

1

5

... More
LT Distribution Box for 200 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (200KVA) and suitable MCCBs for outgoing circuits with terminal extensions

1

1

1

... More
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp (63/100/250KVA) and suitable MCCBs for outgoing circuits with terminal extensions

7

1

7

... More
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 100Amp and suitable MCCBs for outgoing circuits with terminal extensions

1

1

1

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

28

1

28

... More
Wedge Connectors/PG Clamps

84

1

84

... More
Danger Plates with Clamps

14

1

14

... More
GI Barbed Wire for Anti Climbing

234

1

234

... More
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole

28

1

28

... More
Painting of Poles Red Oxide

28

1

28

... More
Painting of Poles Aluminium Paint

28

1

28

... More
Sundry items like aluminium lugs, jumper binding Tape

14

1

14

... More
Transformer Fencing

9

1

9

... More
HT Line (Supply)

-

-

-

... More
11 Mtr. Long Pole( ST-410 SP56)

6

1

6

... More
9 Mtr. Long Pole( ST-410 SP33)

115

1

115

... More
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)

1605

1

1605

... More
30 mm² ACSR Conductor

17.95

1

17.95

... More
Supply of GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg

285

1

285

... More
GI Channel X-arm including clamps and Braces for DP (80Kg/DP)

730

1

730

... More
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

387

1

387

... More
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

84

1

84

... More
Galvinized Nuts and Bolts

121

1

121

... More
Danger Plates with Clamps

121

1

121

... More
Anti-Climbing Device with Clamps

121

1

121

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

121

1

121

... More
Red Oxide

121

1

121

... More
Aluminium Paint

121

1

121

... More
Cement bottoming 1:2:4 mix as per REC standards 0.6cum /pole

6

1

6

... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole

115

1

115

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

5

1

5

... More
11KV Link Set

6

1

6

... More
HT Line (Installation/Testing/Commissioning Part)

-

-

-

... More
11 Mtr. Long Pole( ST-410 SP56)

6

1

6

... More
9 Mtr. Long Pole( ST-410 SP33)

115

1

115

... More
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)

1605

1

1605

... More
30 mm² ACSR Conductor

17.95

1

17.95

... More
GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg

285

1

285

... More
GI Channel X-arm including clamps and Braces for DP (80Kg/DP)

730

1

730

... More
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

387

1

387

... More
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

84

1

84

... More
Galvinized Nuts and Bolts

121

1

121

... More
Danger Plates with Clamps

121

1

121

... More
Anti-Climbing Device with Clamps

121

1

121

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

121

1

121

... More
Red Oxide

121

1

121

... More
Aluminium Paint

121

1

121

... More
Cement bottoming 1:2:4 mix as per REC standards 0.6cum /pole

6

1

6

... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole

115

1

115

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

5

1

5

... More
11KV Link Set

6

1

6

... More
LT Line (Supply)

-

-

-

... More
8 Mtr. Long Pole( ST-410 SP15)

115

1

115

... More
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)

62

1

62

... More
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)

508

1

508

... More
30mm² ACSR Conductor

9

1

9

... More
50mm² ACSR Conductor

8

1

8

... More
16kN Polymer Shackle Insulators

434

1

434

... More
Galvinized Nuts and Bolts.

115

1

115

... More
Eye Hook with clamp set

26

1

26

... More
Suspension Clamp

26

1

26

... More
Tension Clamp

14

1

14

... More
50sqmm LT AB Cable (3x120+1x16+1x70sqmm) XLPE (1.1KV, 3+1C, AL)

2

1

2

... More
35sqmm 1-Core Cable, 1.1KV Grade XLPE unarmoured FRLS Type

180

1

180

... More
IPC Connectors

310

1

310

... More
SMDB Box

23

1

23

... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

115

1

115

... More
Red Oxide

115

1

115

... More
Aluminium Paint

115

1

115

... More
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole

115

1

115

... More
LT Line (Installation/Testing/Commissioning Part)

-

-

-

... More
8 Mtr. Long Pole( ST-410 SP15)

115

1

115

... More
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)

62

1

62

... More
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)

508

1

508

... More
30mm² ACSR Conductor

9

1

9

... More
50mm² ACSR Conductor

8

1

8

... More
16kN Polymer Shackle Insulators

434

1

434

... More
Galvinized Nuts and Bolts.

115

1

115

... More
Eye Hook with clamp set

26

1

26

... More
Suspension Clamp

26

1

26

... More
Tension Clamp

14

1

14

... More
50sqmm LT AB Cable (3x120+1x16+1x70sqmm) XLPE (1.1KV, 3+1C, AL)

2

1

2

... More
35sqmm 1-Core Cable, 1.1KV Grade XLPE unarmoured FRLS Type

180

1

180

... More
IPC Connectors

310

1

310

... More
SMDB Box

23

1

23

... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

115

1

115

... More
Red Oxide

115

1

115

... More
Aluminium Paint

115

1

115

... More
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole

115

1

115



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.