Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 6,73,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14206_1Bid Award Id
ViewTender No
e-NIT No. 57 of ED Leh of 2024-25 dated 21-09-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing and Commissioning for Creation of 2x500KVA Sub-Station along with laying of dedicated HT Line from Bombgarh Sub-Station Leh to New Court Complex at Meylong thang on full turnkey basis under Deposit Work 2024-25.
BOQ Items
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
2
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
2
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
2
-
-
630 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for DTs
176
-
-
9 Mtr. Long Pole,ST-410 SP33)
2
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
12
-
-
GI Channel/Angle/Flat of sizes including clamps
600
-
-
Galvinized Nuts and Bolts.
16
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
12
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
HT Meter with HT Cable including Input/Output termination Set (75/5 complete Set (Smart meter)
1
-
-
Wedge Connectors/PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
30
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
2
-
-
Painting of Poles Red Oxide
2
-
-
Painting of Poles Aluminium Paint
2
-
-
Sundry Itemss like aluminium lugs, Jumpers, binding Tape
2
-
-
RCC Tranformer bed for compact 500KVA
2
-
-
VCB Breaker 33KV level, including cables and Gantary complete set
1
-
-
11KV 3 core 185sqmm XLPE cable FRLS (One Spare Cable)
0.2
-
-
Outdoor cable termination Kits
2
-
-
Indoor cable termination Kits
2
-
-
Transformer Fencing
2
-
-
DT (Installation/Testing/Commissioning Part)
-
-
-
Compact Substation with single panel VCB RMU 630A 11KV + 500KVA Oltc Transformer with RTCC panel +1000 Amps ACB outgoing
2
-
-
RMU 3 way (2 Incomer and Outgoing) VCB
1
-
-
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
2
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
2
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
2
-
-
630 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for DTs
176
-
-
9 Mtr. Long Pole,ST-410 SP33)
2
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
12
-
-
GI Channel/Angle/Flat of sizes including clamps
600
-
-
Galvinized Nuts and Bolts.
16
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
12
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
HT Meter with HT Cable including Input/Output termination Set (75/5 complete Set (Smart meter)
1
-
-
Wedge Connectors/PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
30
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
2
-
-
Painting of Poles Red Oxide
2
-
-
Painting of Poles Aluminium Paint
2
-
-
Sundry Itemss like aluminium lugs, Jumpers, binding Tape
2
-
-
RCC Tranformer bed for compact 500KVA
2
-
-
VCB Breaker 33KV level, including cables and Gantary complete set
1
-
-
11KV 3 core 185sqmm XLPE cable FRLS (One Spare Cable)
0.2
-
-
Outdoor cable termination Kits
2
-
-
Indoor cable termination Kits
2
-
-
Transformer Fencing
2
-
-
HTLine (Supply Part)
-
-
-
9 Mtr. Long Pole ( ST-410 SP33)
100
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
1200
-
-
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
475
-
-
GI Canel x-arm including clamp and bress for DP (80kg/DP)
960
-
-
50 mm² ACSR Conductor
3.5
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
300
-
-
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
75
-
-
Galvinized Nuts and Bolts
100
-
-
Danger Plates with Clamps
100
-
-
Anti-Climbing Device with Clamps
100
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
100
-
-
Red Oxide
100
-
-
Aluminium Paint
100
-
-
Silicon Cover
100
-
-
Cement bottoming 1:2:4 mix as per REC standards ..5cum /pole
100
-
-
HT Line (Installation/Testing/Commissioning Part)
-
-
-
9 Mtr. Long Pole ( ST-410 SP33)
100
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
1200
-
-
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
475
-
-
GI Chanel x-arm including clamp and bress for DP (80kg/DP)
960
-
-
50 mm² ACSR Conductor
3.5
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
300
-
-
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
75
-
-
Galvinized Nuts and Bolts
100
-
-
Danger Plates with Clamps
100
-
-
Anti-Climbing Device with Clamps
100
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
100
-
-
Red Oxide
100
-
-
Aluminium Paint
100
-
-
Silicon Cover
100
-
-
Cement bottoming 1:2:4 mix as per REC standards ..5cum /pole
100
-
-
LT Line (Supply Part)
-
-
-
HDPE Pipe outer 180sqmm inner dia 152mm for laying of LT Cable
1200
-
-
3.5C x 185sqmm AL conductor XLPE (E) armoured cable
1200
-
-
3.5C x 95sqmm AL conductor XLPE (E) armoured cable
500
-
-
Supply of 415V, 3-phase, 4 wire, 50 Hz, 35 KA/1Sec LT Feeder Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with Microprocessor based 4-pole, MCCB of various ratings as incomer & specified rating outgoings with 4-pole, MCCB/4-P MCB's, as per the internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, CT operated TVM, metering as per technical spec, support channels, rain sheds, omplete in all respect. The OGA & Scheme of the panel shall be supplied in line with the technical specification as per the following types
2
-
-
Supply of 415V/230 V, 3-phase, 4 wire and Neutral, 50 Hz, 25-10 KA/1Sec LT service Distribution Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with specified ratings incoming circuit having 4-pole, MCCB with all outgoing provided with U-clamp & fuse assembly sets of the rating as specified in the SLD as per technical specification. Service pillar to be used with combination of Feeder Pillars shall be complete with internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, support channels, rain sheds, complete in drawing. The LT sevice pillar shall be as per the approved minimum IP55 protection class. The LT service panel shall be supplied in line with the technical specification as per the following types
8
-
-
Supply of Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
12
-
-
Supply of termination of 3.5C x 95sqmm
64
-
-
Supply of termination of 3.5C x 185sqmm
44
-
-
Supply of GI Flat 25x6mm for earthing of service pillar
150
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /foundation of main feeder pillar and sub feeder pillars
10
-
-
1R 4Core X 25sqmm AL Conductor, XLPE, armoured cable
400
-
-
1R 4Core X 16sqmm AL Conductor, XLPE, armoured cable
300
-
-
LT Line (Installation/Testing/Commissioning Part)
-
-
-
HDPE Pipe outer 180sqmm inner dia 152mm for laying of LT Cable
1200
-
-
3.5C x 185sqmm AL conductor XLPE (E) armoured cable
1200
-
-
3.5C x 95sqmm AL conductor XLPE (E) armoured cable
500
-
-
Installation/Testing/Commissioning of 415V, 3-phase, 4 wire, 50 Hz, 35 KA/1Sec LT Feeder Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with Microprocessor based 4-pole, MCCB of various ratings as incomer & specified rating outgoings with 4-pole, MCCB/4-P MCB's, as per the internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, CT operated TVM, metering as per technical spec, support channels, rain sheds, omplete in all respect. The OGA & Scheme of the panel shall be supplied in line with the technical specification as per the following types
2
-
-
Installation/Testing/Commissioning of 415V/230 V, 3-phase, 4 wire and Neutral, 50 Hz, 25-10 KA/1Sec LT service Distribution Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with specified ratings incoming circuit having 4-pole, MCCB with all outgoing provided with U-clamp & fuse assembly sets of the rating as specified in the SLD as per technical specification. Service pillar to be used with combination of Feeder Pillars shall be complete with internal wiring. Bus bars, Link sets, power terminals of adequate size for cable terminations, indications, support channels, rain sheds, complete in drawing. The LT sevice pillar shall be as per the approved minimum IP55 protection class. The LT service panel shall be supplied in line with the technical specification as per the following types
8
-
-
Installation/Testing/Commissioningof Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
12
-
-
Installation/Testing/Commissioningof termination of 3.5C x 95sqmm
64
-
-
Installation/Testing/Commissioning of termination of 3.5C x 185sqmm
44
-
-
Installation/Testing/Commissioningof GI Flat 25x6mm for earthing of service pillar
150
-
-
Installation/Testing/CommissioningCement bottoming 1:2:4 mix as per REC standards 0.5cum /foundation of main feeder pillar and sub feeder pillars
10
-
-
Installation/Testing/Commissioning of 1R 4Core X 25sqmm AL Conductor, XLPE, armoured cable
400
-
-
Installation/Testing/Commissioning of 1R 4Core X 16sqmm AL Conductor, XLPE, armoured cable
300
-
-
Evaluation Notes How It Works ?