National Institute Of Technology Tender
... More
The NIT has issued a formal invitation for competitive bids for the National Institute Of Technology project, for Replacing The Existing Db And Modification Of Ups Connection At Health Centre in Kozhikode, Kerala, with an estimated contract value of Rs. 2,08,804. The bid opening date for this tender is 19-05-2025 and the last date for bid submission is 09-06-2025. Interested bidders for National Institute Of Technology tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 4,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_NITC_860710_1Tender No
Engg/EMU/AE-101/Health centre/2025Tender Authority
National Institute Of Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for circuit/ submain wiring alongwith earth wire with the 4 x16 sq.mm + 2 x 6 sq.mmof FRLS PVC insulated copper conductor, single core cable in surface/ recesssed medium class PVC conduit as required.
9
-
-
... More
Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
125
-
-
... More
Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
60
-
-
... More
Supplying and fixing of 32 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
8
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular switch socket outlet and 15/16A modular switch , connections etc. as required.
3
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
15
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
Supplying and fixing 4 pole MCB metal enclosure on surface / recess, complete with earth bar, din bar, detached gland plate, interconnection, phosphetized and powder painted including earthing etc. as required.
2
-
-
... More
Supplying and fixing 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
Supplying and fixing 63A rating, Four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
Supplying and fixing single pole blanking plate in the existing MCB SB complete etc.as required.)
22
-
-
... More
Supplying of one number 3.5 C x 70 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required.
20
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 35 sq. mm Upto 95 sq. mm (clamped with 1mm thick saddle) size on wall surface/pipe as required.
20
-
-
... More
Supply and laying of one number of 8 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.
32
-
-
... More
Supply and making end termination with brass compression gland and aluminium legs for 3.5 C x 70sq.mm (32 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required.
2
-
-
... More
Supplying and fixing 3 phase 8 way(4+24) , double door, vertical type three pole and neutral ,sheet steel,MCB distribution board,415 V on suface/recess mounting, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)
1
-
-
... More
Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of four pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1
-
-
... More
Providing and fixing 125 A, 36 KA, FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections ,etc.as required.
1
-
-
... More
Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of three pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
Charges for removing the old wall mounted DB's, making good the damages of the wall/ floor including painting, dismantle the DB and other accessories without any damage and conveyance of the material to the godown etc, as required.
2
-
-
... More
Supplying and making end termination of suitable size for the submain wiring with suitable lugs for 4 x 16 + 2 x 6 sqmm of PVC insulated copper conductor.
2
-
-
... More
Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
4
-
-
... More
Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
4
-
-
... More
Supplying and fixing 1/2 module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
8
-
-
... More
Supplying and fixing 3 phase 6 way , double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)
1
-
-
... More
Charges for cleaning and spray painting the existing Panel board of 180 x 95 x 40 or nearest size with two coats of suitable colour (Grey) paint, over a coat of primer in installed position and marking the identification of switches with white paint etc, as required
1
-
-
... More
Fabrication & fixing of 123 x 93 cm panel board Sheet made from 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, providing rubber beadings and suitable size hinches, Nuts & Bolts for fixing on the existing panel board etc. as required.
1
-
-
... More
Fabrication & fixing of 94 x 42 cm panel board Sheet made from 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, providing rubber beadings and suitable size hinches, Nuts & Bolts for fixing on the existing panel board etc. as required.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%