National Institute For Interdisciplinary Science And Technology Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
National Institute For Interdisciplinary Science And Technology - NIIST Tender
Civil And Construction
Building Construction
Eprocure
Opening Date9 Jan 2025
Closing Date24 Jan 2025
Tender Amount₹ 7,06,854
Costs
EMD
₹ 14,140Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CSIR_223491_1Bid Award Id
ViewTender No
NIIST/WKS/CE/049/2024-25Tender Authority
National Institute For Interdisciplinary Science And Technology ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
2.5
-
-
... More
Dismantling doors,windows and clerestory windows (steel or wood) shutter including chowhats,architrave,holdfast etc.complete and stacking within 50 metres lead: of area 3 sq.metres and below
1
-
-
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
5
-
-
... More
MASONRY WORK
-
-
-
... More
Brick work with common burnt clay F.P.S (non modular)bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: cement mortar 1:6 (I cement : 6 coarse sand)
0.5
-
-
... More
FINISHING
-
-
-
... More
12 mm cement plater of mix: 1:4 (1 cemet: 4 fine sand)
8
-
-
... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour - Two coats
115
-
-
... More
Melamine polishing on wood work (one or more coat)
14
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
23
-
-
... More
FALSE CEILING
-
-
-
... More
Providing and fixing tiled false ceiling of specified materials of size595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
26
-
-
... More
FLOORING
-
-
-
... More
Providing and fixing homogeneous polyvinyl chloride sheet / tile in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhesives of approved quality and manufacturer like Dunlop 5-758,Fevicol SR 998 or equivalent including rolling with light wooden rooler weighting about 5 kg. All complete as directed by Engineer-in-Charge ,in approved colour and shade 2.0 mm thick
37
-
-
... More
ALUMINIUM WORK
-
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):
-
-
-
... More
For fixed portion - Powder coated aluminium (minimum thickness of powder coating 50 micron)
45
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
29
-
-
... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. - Pre-laminated particle board with decorative lamination on both sides
8
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): - With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
4
-
-
... More
Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
2
-
-
... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : - 125 mm
4
-
-
... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - 300x10 mm
2
-
-
... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete - Twin rubber stopper
1
-
-
... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
1
-
-
... More
REPAIRS TO BUILDING
-
-
-
... More
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames,including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
2
-
-
... More
FURNISHING WORKS
-
-
-
... More
Supplying and fixing vertical blinds,window fashion or equivalent brand as approved by the Engineer-in-charge. Cost inluding necessary materials for fixing the vertical blinds.
6
-
-
... More
PART-B, Electrical Works (DISTRIBUTION BOARD)
-
-
-
... More
Supplying and fixing following ways surface/ recess mounting, vertical type 415 volts on, TPN MCB distribution board of sheet steel, dust protected , duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs ( But without MCBs and incomer) as required. 8 way (4+24),Double door
1
-
-
... More
Supplying and fixing 5A to 32A rating, 240/415V, 10KA, « c » curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required.
-
-
-
... More
Single pole – 16A
12
-
-
... More
Single pole – 20A
3
-
-
... More
Triple Pole-32A
2
-
-
... More
Supplying and fixing 40A rating, 240/415V, 10KA, « c » curve, miniature circuit breaker suitable for inductive load of double pole MCB in the existing MCB DB complete with connections , testing and commissioning etc. as required.
4
-
-
... More
Supplying and fixing of foolowing way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
1
-
-
... More
Supplying and fixing following rating, four pole, ( three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commisioning etc. as required. 63A
1
-
-
... More
WIRING FOR LIGHT/FAN/PLUG SOCKETS, ETC
-
-
-
... More
Wiring for light point /fan/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc . as required. Group C
3
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit along with 1 No. 4 sq. mm FLRS PVC insulated copper conductor, single core cable for loop earthing as required.
20
-
-
... More
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3X2.5 sq.mm
150
-
-
... More
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3X6 sq.mm
60
-
-
... More
Supplying and Fixing of 100X50 mm cable trunking system with all accessories for fixing of PVC modular box/plug sockets as required.
25
-
-
... More
Supplying and fixing the following modular PVC 35mm Deep Mounting Box for cable trunking system etc. as required. 3 Module
20
-
-
... More
Supplying and fixing the following modular base & cover plate on existing modular metal boxes etc. as required. 3 Module
20
-
-
... More
Supplying and fixing the following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
5/6 A switch
4
-
-
... More
15/16 A switch
16
-
-
... More
3 pin 5/6 A socket outlet
4
-
-
... More
3 pin 15/16 A socket outlet
16
-
-
... More
Dismantling the existing Distribution Board, PVC conduits, wires etc. as required and Rewiring of same wires in the existing surface/recess steel/PVC conduit as required
1
-
-
... More
ENCLOSURES
-
-
-
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess suitable for 240V, DP MCB complete with connections, testing and commissioning etc. as required.
4
-
-
... More
LIGHT FIXTURES
-
-
-
... More
Supply of 2'x2' LED Recess Luminaire with CRCA housing and fully diffused prismatic diffuser with the following specifications: 230V, 50Hz supply, minimum lumens ≥3600, efficiency ≥ 100 lumens / Watt, Driver efficiency ≥ 85%, ≥4KV Surge protection, short circuit and overload protection, THD 0.9, CRI 80, CCT of 6500K (cool day light), IP20 protected, Lumen as per LM80 and life of LED @ 50k hrs, EMC compliance and confirming to IS: 10322 and IS:16108 with latest amendments.
2
-
-
... More
Installation, testing, commisioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
6
-
-
... More
CABLE LAYING AND END TERMINATION
-
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE alumium conductor cable of 1.1 KV grade as required. 4 X 35 sq.mm (32mm)
1
-
-
... More
EARTHING
-
-
-
... More
Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length, 17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth 7.06 strip, earth enhancing compound (12.5 kg mineral compound/22.6 kg low resistivity graphite compound) and providing masonry enclosure with heavy duty Cl cover plate of 300X300 mm having locking arrangement.
1
-
-
... More
Supplying and laying 25 mm X 5 mm copper strip at 0.5 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer, etc. as required ( Jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50 mm)
25
-
-
... More
AIR CONDITIONERS
-
-
-
... More
Supply ,Installation , Testing & Commissioning of non-inverter Ductable Split Air conditioners of 2 TR capacity with R-32 or R410a Refrigerants
2
-
-
... More
Copper Piping between IDU & ODU (Size as per manufacturer standard with insulation of Minimum 9 mm thick Closed Cell Nitrile Rubber, covered with white Tape
15
-
-
... More
Supply & lying of Cabling as per Manufacturer standard size and core between IDU & ODU
20
-
-
... More
Supply & fixing of Aluminum Powder coated Linear Bar Supply Air Grille on the mouth of IDUs
1
-
-
... More
Supply & laying of drain line pipping of 1.5 inch PVC Pipes with insulation of Minimum 9 mm Closed cell foam
15
-
-
... More
Supply & fixing of Dual A/C Controller [Automatic Changeover Timer]