National Centre For Earth Science Studies Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

National Centre For Earth Science Studies - NCESS Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date5 Sep 2024
Closing Date12 Oct 2024
Tender Amount₹ 5,85,822 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.1 In stringers, treads, landings etc. of staircases, including use of chequered plate wherever required, all complete

190

19427

102.25

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.3 G.I. pipes

15

2703

180.2

... More
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

2

177

88.5

... More
Providing and fixing bolts including nuts and washers complete.

2

280

140.15

... More
1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)

1.4

10311

7365.15

... More
Centering and shuttering including strutting, propping etc. and removal of form work for: 4.3.1 Foundations, footings, bases for columns and Centering and shuttering including strutting, propping etc. and removal of form for 5.9.15 Small lintels not exceeding 1.5 m clear span, moulding as in cornices, windowsills, string courses, bands, copings, bed plates, anchor blocks and the like

4.6

1416

307.95

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

25

2241

89.65

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2, 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)

0.53

4433

8364.2

... More
12 mm cement plaster of mix: 13.4.1, 1:4 (1 cement: 4 coarse sand)

17.8

5469

307.25

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 13.52.1 On steel work

60

12102

201.7

... More
Finishing walls with Acrylic Smooth exterior paint of required shade: 13.112.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm)

120

8892

74.1

... More
For cutting the existing iron grill work at old panel room and assembling and fixing the cut pieces to make a door opening of suitable size height and shape - 0102 Blacksmith 1st class

1

784

784

... More
0114 Beldar

0.5

322

645

... More
1214 Gas cutting by gas plant

50

100

2

... More
1215 Gas Welding by electric plant

50

100

2

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: 15.12.1 Of area 3 sq. metres and below

2

605

302.7

... More
For fixed portion, Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)

46

21449

466.3

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

5

6627

1325.55

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions (Glazing, paneling and dash fasteners to be paid for separately): For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)

19

10731

564.8

... More
Supplying and fixing I max hinges

24

3096

129

... More
Providing woodwork in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood

0.04

5526

131576.95

... More
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

3.78

11665

3086.1

... More
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 9.24.1 Rectangular or square

0.23

39

173.95

... More
Providing and fixing IS: 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 9.70.1 125x64x1.90 mm

8

764

95.5

... More
Providing and fixing IS: 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.71.1 125x64x2.50 mm

8

833

104.2

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.97.1 300x10 mm

4

470

117.65

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.97.5 100x10 mm

4

234

58.65

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.100.1 125 mm

2

120

60.05

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.100.3 75 mm

8

370

46.3

... More
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction (Only weight of grill to be measured for payment).

6

3365

560.85

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions 21.2.2 Pre-laminated particle board with decorative lamination on both sides

1.5

1426

951.05

... More
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

1

8512

8512.1

... More
CI @147

341307.56

160414

0.47

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

2

1986

993

... More
Group B

2

2320

1160

... More
Group C

9

13005

1445

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

10

2330

233

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

5

2850

570

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

15

5010

334

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

15

8055

537

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 12 way, Double door

1

2573

2573

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1

256

256

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

527

527

... More
Supplying fixing telephone socket outlet suitable for connecting the exisiting EPABX system including wiring, testing, commissioning etc as required.

10

2250

225

... More
Supplying and fixing LED type tube fitting of 2 feet long 20w on the wall ceiling including providing including connections testing commissioning etc as required.

6

1860

310

... More
Supplying and fixing of 300mm sweep wall mounting fan on the wall suitable for operation on 230V, single phase,50Hz AC supply including providing connetion ,testing,commissioning etc as required.(M/s:cromption/usha/orcent)

5

19690

3938

... More
Supplying and fixing 300 mm sweep light duty exhaust fan suitable for operation on 230V,,single phase,50Hz AC supply including providing connetion ,testing,commissioning etc as (M/s:cromption/usha/orcent)

2

4848

2424

... More
CI @34.55% electrical

13444

13444

1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.