Local Self Government Department Tender
... More
The LSGD has issued a formal invitation for competitive bids for the Local Self Government Department project, for Annual Plan-kozhikode Corporation Project- Shifting Of Air Conditioner Units From Tagore Hall To Corporation Office -general Electrical Work in Kozhikode, Kerala, with an estimated contract value of Rs. 11,86,352. The bid opening date for this tender is 11-04-2025 and the last date for bid submission is 18-04-2025. Interested bidders for Local Self Government Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 29,659Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_LSGD_748882_1Bid Award Id
ViewTender No
PP/EG7/2024-25/SE/525Tender Authority
Local Self Government Department ViewPurchaser Address
-Website
http://https://lsgkerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
OD344729/2024-2025:SITC of air supply diffusers of powder coated aluminum with alu. volume control dampers as per specification
1
-
-
... More
OD344719/2024-2025:Supply an installation of Five micron filters for pre-filtration of air down to 5 micron at an efficiency of 98.5% suitable for AHU
1
-
-
... More
OD344720/2024-2025:Supply and installation of class 'O' type nitrile rubber 10mm thick open cell elastomeric insulation for thermal insulation of duct make A flex/ K flex/ equivalent
75
-
-
... More
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
125
-
-
... More
OD355638/2024-2025:Installation testing and commissioning of out door unit of 17 TR AC unit in new location using necessary angle iron support/ direct on RC roof slab/ sun shade slab, connecting copper pipes, giving electrical inter connections from AHU etc complete required at site.
2
-
-
... More
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
450
-
-
... More
OD356239/2024-2025:Dismantling the existing outdoor and indoor units of 3 TR packaged AC unit from its existing position after removing the electrical connections, Copper pipe connections etc. without any damages, conveying the same to new location and installation testing and commissioning after attending minor repairs/replacement of spares , overhauling, gas filling cleaning etc as required
1
-
-
... More
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
30
-
-
... More
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
60
-
-
... More
OD345600/2024-2025:Dismantling the existing out door unit of 17 TR AC unit (8.5 TR x 2 Nos) from its existing position after removing the electrical connections, Copper pipe connections etc. without any damages, conveying the same to ground level from Terrace floor using suitable tools and plant etc. as required at site.
2
-
-
... More
OD355965/2024-2025:Supply and providing suitable size canvas coupling for connecting the AHU unit with existing/ proposed Duct
4
-
-
... More
OD344725/2024-2025:Supply and providing following size hard/ soft drawn copper pipe for the extending the pipe between outdoor and indoor unit including providing rubberized form sleeve 10mm thick, brazing, leak testing etc. size 11/8 inch 22 gauge soft drawn copper pipe insulated using 10 mm thick rubber nitrite insulation
40
-
-
... More
OD344721/2024-2025:Supply and installation of 0.3 micron filters for pre filtration of air down to 0.5 micron at an efficiency of 99.7% suitable for AHU
1
-
-
... More
OD344948/2024-2025:Installation testing and commissioning of 17 TR AHU in new location using necessary hanging support in the RC slab ceiling, connecting copper pipes, duct assembly and giving electrical inter connections from out door unit etc complete required at site.
2
-
-
... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
47
-
-
... More
OD355788/2024-2025:Reconditioning/repairing the existing AHU indoor cabinet after removing the damaged portion, cutting and joining and painting including replacing the support etc. as required at site
12.5
-
-
... More
OD542109/2024-2025:Dismantling the existing 11 TR condenser unit of Air Conditioning units complete and clear out all materials from the site
3
-
-
... More
OD344724/2024-2025:Supply ,installation ,testing and commissioning of micro processor control panel for 8.5 / 11 / 17 TR AHU
4
-
-
... More
OD344949/2024-2025:loading, transporting the dismantled AHU unit of 17TR AC unit to the nearest AC service center, complete overhauling, repairing/replacing the defective accessories, consumables etc. if required, leak/pressure testing, and transporting to the new location without any damage including un loading
2
-
-
... More
OD344723/2024-2025:Supply and providing following size hard/soft drawn copper pipe for the extending the pipe between outdoor and indoor unit including providing rubberized form sleeve 10mm thick, brazing, leak testing etc. size 5/8 inch 22 gauge soft drawn copper pipe insulated using 10 mm thick rubber nitrite insulation
40
-
-
... More
OD345620/2024-2025:loading, transporting the dismantled Out door unit of 17TR AC unit (2 Nos 8.5 TR) to the nearest AC service center, complete overhauling, repairing/replacing the defective accessories, consumables etc. if required, leak/pressure testing, and transporting to the new location without any damage including un loading
2
-
-
... More
OD344947/2024-2025:Dismantling the existing AHU of 17 TR AC unit from its existing position after removing the electrical connections, Copper pipe connections etc. without any damages, conveying the same to ground level from AHU Room using suitable tools and plant etc. as required at site.
2
-
-
... More
OD542144/2024-2025:Dismantling the existing damaged condenser unit and Air handling unit of Air Conditioning units complete and clear out all materials from the site
2
-
-
... More
OD344718/2024-2025:Supply fabrication and installation of 40 mm thick AHU out door cabinet for maintaining required temperature made with preprinted galvanized GI sheets of required thickness and density locking type construction film coated surface PUF insulated , supporting with powder coated GI angle and channels, off white color and suitable door opening for inspection and service etc as required at site
35
-
-
... More
OD344726/2024-2025:Supply and filling of R-410 gas
30
-
-
... More
90.6.4.52:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 2 Run
105
-
-
... More
OD542101/2024-2025:Dismantling the existing 33 TR damage chiller unit Unit of Air Conditioning units complete and clear out all materials from the site.
1
-
-
Evaluation Notes How It Works ?
Potential Partner