KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date24 Jun 2024
Closing DateCancelled
Tender Amount₹ 10,04,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

1695.98

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

47.9

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

1362.59

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

15.82

-

-

... More
od233456/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/rock.

101.98

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

6.93

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

127.68

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

36.74

-

-

... More
od334246/2021_2022 : Providing applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.

50.54

-

-

... More
4.10 : Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).

50.54

-

-

... More
4.17 : Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

81

-

-

... More
od334126/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level

9.25

-

-

... More
od233430/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note:- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).All work upto plinth level.

383.71

-

-

... More
od300780/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 320 kg/ cum. (Note: - Minimum Cement content considered in this item is @ 320 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).All work upto plinth level

50.79

-

-

... More
od231118/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work above plinth level upto floor V level

21.16

-

-

... More
od230405/2020_2021 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting) .All work above plinth level upto floor V leve

606.08

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

329.18

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1299.44

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

2075.28

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2149.93

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1026.25

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

170.99

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1028.84

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

404.6

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

1607.81

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

14.77

-

-

... More
5.13 : Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span up to floor five level, including the cost of required centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

4.77

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

48349.53

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

95224.66

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

931.36

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

69.01

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor Vlevel with RCC band at sill level and lintel level with approved block laying polymermodified adhesive mortar all complete as per direction of Engineer-in-Charge. (Thepayment of RCC band and reinforcement shall be made for seperately).

437.66

-

-

... More
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

8.7

-

-

... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

35.28

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

49.12

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

17.13

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

0.73

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

36.32

-

-

... More
od230396/2020_2021 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

36.14

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

671.7

-

-

... More
od290368/2021_2022 : Extra for solid block/brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

63.25

-

-

... More
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

1.32

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

4479.23

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

1066.8

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

190.32

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

14.34

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

18.9

-

-

... More
od179949/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item) With Toughened glass panes of 6 mm thickness

84

-

-

... More
od337612/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item) With toughened glass panes of 8 mm thickness

96.12

-

-

... More
od230424/2020_2021 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item) With Toughened glass 12 mm thickness

4.8

-

-

... More
21.17 : Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).

230

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

202.2

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

51.12

-

-

... More
9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710

419.62

-

-

... More
9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

443.77

-

-

... More
od230640/2020_2021 : Providing and fixing of Galvanized hollow lead lined metal door conforming to IS 277 (2003) . Door frame shall be double rebate profile of size 143 x 57 mm (approx.) made out of approx. 2.0mm (14 gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height shall be protected with minimum 2 mm thick lead line. All provision shall be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers shall be provided on the strike jamb. Frames shall be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry/RCC wall opening.Installed frame shall be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be approx. 48mm thick fully flush double skin door and Door leaf shall be manufactured from approx 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door shall be rigid with lead line of minimum 2 mm thick all across the inside of the exposed surface. In addition the door shall have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges shall be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. All doors and frames shall be finished to powder coated for minimum 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. <br>Lead lined Steel Door Single leaf of size 1.2 X 2.40 m , the rate shall includes the cost and conveyance of all materials , labour charges,lead,lift, hardware like SS ball bearing hinges 100x75x3.0- 04 Nos.in each panel ,mortise dead lock with cylinder and both side key operation - 1 no , SS D type pull handle 300 X 20 mm - 1 set in each panel , heavy duty door closer- 1 no in each panel,Tower bolt 450 mm-1 no in each panel and anchor fastener etc. complete as directed by the Engineer-in-Charge at all levels.

1

-

-

... More
od233018/2020_2021 : Providing and fixing of Wooden lead lined window with window frame shall be Single rebate profile of size 120 x 70 mm (approx.) made out of Hardwood (Red Mirandi) with 2 mm Lead Sheet sand witched in window frame. Frame shall be finished with primer finish .Window shall be fixed with 10 mm thick<br>Lead Glass . Lead lined wooden fixed window with size – 1.0 X 0.8 m . The inside face of the frame face trim to rebate height shall be protected with minimum 2 mm thick lead line. Frames shall be provided with HRD Fasteners of Fischer Make or equivalent for installation on a finished plastered masonry/RCC wall opening. Installed frame shall be grouted with cement & sand slurry necessary for window on the clear masonry opening. The rate shall includes the cost and conveyance of all materials , labour charges, lead,lift,Lead glass of 10 mm thick and anchor fastener etc. complete as directed by the Engineer-in-Charge at alllevels.

0.8

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded)

133.8

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

43.95

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

1.98

-

-

... More
10.11.1 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)

121.5

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

28.44

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

8

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

1.88

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

59.82

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

6

-

-

... More
od230435/2020_2021 : Providing and fixing a pair of back to back D type pull Handle of 25 mm Dia X 300 mm size , mirror polished SS 304 grade with all fixtures and necessary ss screws etc.including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by the Engineer-in-Charge at all levels.

16

-

-

... More
od230418/2020_2021 : Supplying And Fixing a pair of fire rated Solid SS Lever Handle and Mortise Lock case with Cylinder of approved size and quality for fire rated steel doors etc complete all works including all required fixtures as directed by Engineer in Charge.

17

-

-

... More
od180403/2021_2022 : Providing and fixing Dash hold fastener 12.5 mm dia, 50 mm long with 6 mm dia bolt, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.

700

-

-

... More
od180424/2021_2022 : Providing and fixing satin finish stainless steel corner lock, prepared for Euro profile cylinder, single throw, bolt projection 20 mm including epc both side key operation and lock keeper plate of approved quality with necessary screws including cost and conveyance of all materials,labour charges,lead, lift etc. complete as directed by the Engineer in Charge.

1

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

4

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

162

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

44

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

37

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

88

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

39

-

-

... More
od132428/2021_2022 : Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding window with necessary screws etc. complete.

160

-

-

... More
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop

39

-

-

... More
9.51.2 : Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading

70.98

-

-

... More
od230406/2020_2021 : Providing and fixing corner guard of INPRO make - 160 series or equivalent having vinyl snap-on cover(lead free) of 2mm thickness and aluminium retainer of 2mm thickness that shall be fabricated from 6063-T5 aluminium. Dimensions of corner guard shall be 51mm x 51mm wings and 90 degrees angle. The rigid vinyl profile shall resist an impact of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall not support fungal or bacterial growth in accordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance and shall includes Top and Bottom Caps etc complete all works including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.

67.2

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

540

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

3802.49

-

-

... More
10.19 : Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

180.35

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

643.13

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

6595.81

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

240

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

2056.08

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1028.19

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

296.65

-

-

... More
11.46.3 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800 x 800 mm

60.46

-

-

... More
od230443/2020_2021 : Providing and laying Anti-skid Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

114.8

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.

351.76

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

230.45

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

36.75

-

-

... More
od134945/2021_2022 : Providing and fixing, Highly resistant 2 mm thick pressed homogeneous vinyl floor covering in rolls including skirting (T Group), with non-directional design, colour dyed as a raw mixture to ensure even colour throughout the thickness and a matt finish including self-levelling upto 3mm thick with cementitious material . Its surface is densely compacted for improved wear and ease of maintenance. It is suitable for very heavy traffic. It is treated with Evercare surface treatment, the latest improvement in polyurethane surface treatment obtained by UV laser cross linking process. Evercare avoids stain of chemical products used in healthcare like betadine, eosin or anti-bacterial hand gel which also increases the durability of the flooring that does not require wax for life. Do not require the application of any protective emulsion for life. Abrasion value according to EN 660. 2.0 mm3, group T binder content type I, load resistance class 34/43, residual indentation 0.03mm. Fire classification Bfl-s1. After 28 days the TVOC 10mg/m3 according to ISO 16000-6. REACH compliant. Floorscore certified. Weight 2750 g/m2. ISO717-2 Weighted improvement of impact sound insulation is 8db. Anti-Viral activity (human coronavirus 229E) – ISO 21702….99.7% (after 2h00). It incorporates bacteriostatic and fungistatic actions, tested for Anti-bacterial activity (ISO 22196 99% inhibit the growth of bacteria) The rate is inclusive of cost of all materials, upto 3 mm thick self-levelling, welding all joints, skirting, coving, capping, labour, lead, lift etc. complete as directed by the Engineer-in- Charge at all levels

55.16

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

48.6

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

33.71

-

-

... More
11.45 : Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mmthick sub grade of compacted bed of 20 mm thick nominal size stone aggregateand base course and filling with 150 mm thick jamuna sand, including spreading,well ramming, consolidating and finishing smooth etc. all complete as per directionof Engineer-in-charge.

80

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

24.66

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

465.3

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

21

-

-

... More
8.9.1.2 : Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade

42.48

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

85

-

-

... More
12.51.2 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Flashings / Aprons (Upto 600 mm)

12.5

-

-

... More
12.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)

13

-

-

... More
50.12.2.5 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

73

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.

107.92

-

-

... More
12.52.3 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.

370

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

7155.41

-

-

... More
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

1336.96

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

3421.33

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

2678.76

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

961.08

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

98

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

8832.99

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

527.99

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2730.53

-

-

... More
13.48A.1 : Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and includingpriming coat of exterior primer applied @ 0.90 litre/10 sqm.

7344

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

88

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

414.18

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

47.36

-

-

... More
16.3.3 : Supplying and stacking at site.53 mm to 22.4 mm size stone aggregate

0.72

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

12.6

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

292

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

219

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern.

1460

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

117.7

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

555.5

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

805.88

-

-

... More
od230445/2020_2021 : Supply and application of two coats of White cement based waterproof cement putty with visible water repellancy, very high anti-efflorescence and excellent finish, to make even and smooth finish after pre wetting substrate. Sanding of applied waterproof Putty Surface with emry paper / sand paper above 280 / 320. Application of 1/2 coats of Silicon based Seal-O-Prime or approved equivalent (IGBC/GRIHA certifed best quality primer) with sealer properties having anti-algae and alkali resistance properties damp resistance with 40% dilution with potable water. Application of 3 coats of water based PU with minimum VOC and very less odor having better sheen, finish and film integrity along with anti-algae, antifungal, anti-micro bial and high washable with high stain resiatance should comes under clean room coating requirements.Surface shall be Inspected to check ideal moisture level and pH value of the surface before painting. Surface Prepration with dust removal and sand papering with hand held sanding machine for repainting surface and scrapping new substarte with metal plate called paint scrapper to make smooth and ideal surface for painting .The rate shall include cost and conveyance of all material ,labour charges, lead etc. complete as directed by Engineer - in- charge. (All works covered by this specification shall be carried by an experienced agency having sufficient experience in this type of painting system Only skilled and experienced persons shall be employed for this purpose.)

58.2

-

-

... More
19.18.1 : Supplying and fixing C.I with out frame for manholes:455 x 610 mm rectangular C.I cover ( light duty ) the weight of the cover to be no less than 23 kg

1

-

-

... More
19.18.2 : Supplying and fixing C.I with out frame for manholes:500 mm diameter C.I. (medium duty) the weight of the cover to be not less than 58 kg

13

-

-

... More
od230442/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
od231189/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

8

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

353

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

81

-

-

... More
od233695/2020_2021 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

1

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.72

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.72

-

-

... More
od230730/2022_2023 : Supplying and planting healthy plants of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of plants size 25 cm of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.

3

-

-

... More
od230352/2022_2023 : Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in size 30 cm as per direction of the officer-in-charge.

3

-

-

... More
SANITARY INSTALLATIONS AND FIXTURES

-

-

-

... More
od108632/2021_2022 : Providing and fixing white vitreous china extended wall mounting water closet of<br>approved shape and size including providing & fixing white vitreous china cistern with dual flush fitting, of<br>flushing capacity 2 litre/4 litres , including seat cover, and cistern<br>fittings, nuts, bolts, CP brass angle<br>valve and gasket etc complete as directed by the Engineer in charge at all levels.<br>Models Cera<br>S1031111+B1020105+B1520102/ Hindware 20096 (P-15)+Cist.: 21056 or equivalent<br>with griha water<br>conservation mechanism etc complete as directed by the Engineer in charge at<br>all levels.

10

-

-

... More
17.1.2 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:Stainless Steel AISI-304 (18/8) orissa pattern W.C. pan of size 585x 480 with flush pipe and integrated type foot rests

3

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

15

-

-

... More
od230650/2020_2021 : Providing and fixing star white vitreous china under counter wash<br>basin<br>of<br>approved<br>size & make<br>including one CP brass pillar cock 15 mm NB with aerator<br>including<br>connecting pipes with<br>all fittings 32 mm dia rubber<br>plugs 32 mm dia CP brass waste<br>coupling, 32<br>mm<br>dia CP brass bottle trap,<br>15mm angle valve, etc.<br>complete as directed by the<br>Engineer-incharge<br>at all<br>levels.(Models Cera<br>S2030103/ Hindware 10049+ Cera<br>F1015101/Hindware F280001CP or<br>equivalent with<br>griha water conservation<br>arrangement as per<br>the instructions of the engineer in<br>charge)

15

-

-

... More
od108682/2021_2022 : Providing and fixing white vitreous china wall hung wash basin of approved<br>make<br>including one<br>CP<br>brass pillar cock with water conservation mechanism including connecting pipes<br>with all fittings 32 mm dia<br>rubber plugs 32 mm<br>dia CP brass waste coupling ,complete including<br>CI/MS brackets duly painted,<br>nuts, washers, etc. complete,cost and conveyance of<br>all<br>materials<br>labour charges ,lead, lift<br>necessary wall cutting / chasing and making<br>good<br>the<br>walls,floors,slab,testing and commissioning<br>to the satisfaction of Engineer in charge at<br>all levels. Models Cera S2040105/Hindware 10054+Cera F1015101/Hindware F280001CP or equivalent as<br>instructed by the Engineer in charge

3

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

20

-

-

... More
od230285/2020_2021 : Supplying and fixing approved quality white vitreous china urinal division<br>plate<br>including cost and conveyance of all material, labour charge, lead, lift, etc. complete as directed by<br>the<br>Engineer-in-Charge. Models- Cera S4090101/ Hindware 61001 or equivalent

4

-

-

... More
od230286/2020_2021 : Providing and fixing white vitreous china flat back urinal with sensor<br> and<br>C.P.<br>brass spreaders with brass unions and G.I. clamps complete, including painting of fittings<br>and<br>brackets,<br>cutting and making good the walls and floors wherever required: Models Hindware 6002110 /<br>Cera S4010101<br>or equivalent with griha water conservation mechanism etc complete as directed by the<br>Engineer in charge<br>at all levels

6

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

5

-

-

... More
od230315/2020_2021 : Providing and fixing sink cock of approved quality conforming to IS 8931. Models Cera F1015251/Hindware F330034 or equivalent with griha water conservation mechanism as approved by the engineer in charge at all levels

5

-

-

... More
od224724/2020_2021 : Providing and fixing Stainless Steel A ISI 304 (18/8) 2 station Scrub sink with elbow<br>oberated sink cocks as per IS 13983 with C.I. brackets and stainless steel plugs 40 mm, including painting of<br>fittings and brackets, cutting and making good the walls etc complete as per the requirements of the site in<br>charge including cost of conveyance, testing, commissioning, installation etc.

1

-

-

... More
od108794/2021_2022 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. Models Cera F400002CP/ Jaquar FLR-CHR-5047NGE or equivalent<br>15 mm nominal bore

17

-

-

... More
18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore

6

-

-

... More
od230542/2020_2021 : Providing and fixing CP Brass robe hook as per the instructions of the Engineer in<br>charge. Models Cera F5003108/ Hindware F880004CP or equivalent

15

-

-

... More
od230623/2020_2021 : Providing and fixing sanitary fixtures for handicapped toilet including one wash basin<br>, one number pillar cock with aerator & all other related fittings like CP brass bottle trap,CP brass angle valve, CP brass waste coupling, etc, one number EWC & Cistern complete with fittings & seat cover, one no. hinged rail & 4 nos. of grab rails 60cm etc, designed for people with special needs comes with as<br>per<br>manufacturers specification including cutting and making good the walls and floors wherever required<br>as directed by Engineer-in-Charge. Hindware Matrix Set/Cera Cruse Set, Hindware F280001CP/ Cera F1015101 or equivalent.

2

-

-

... More
od230665/2020_2021 : Providing and fixing premium quality C.P. brass wall shower mixer with griha<br>water<br>conservation mechanism along with overhead shower and shower arm with wall flanges of<br>approved make<br>and model including cost of all materials, labour etc., complete as directed by the<br>Engineer-in-Charge at all<br>levels. Models Cera F7040104+F1015401+F7020304/ Jaquar OHS-CHR-<br>1989GD+FLR-CHR-5273UPRGD or<br>equivalent .

2

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

2

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

2

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

18

-

-

... More
od230688/2020_2021 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade<br>floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete<br>as directed by the directed by the Engineer-in-Charge at all levels<br>

4

-

-

... More
od230695/2020_2021 : Providing and fixing floor trap with cockroach trap (multi trap), exposed, SS304 grade floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels

35

-

-

... More
od230992/2020_2021 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries, etc complete as directed by the Engineer in charge at all levels. 75mm dia

8

-

-

... More
od230995/2020_2021 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels. 110mm dia

5

-

-

... More
od231015/2020_2021 : Supply, Installation, Testing and Commissioning of Solar Water Heater 1000 LPD with heater backup with all necessary accessories as per the requirements of the Engineer in charge at all levels. The rate is inclusive of cost and conveyance of all materials, labour charges etc

1

-

-

... More
od233003/2020_2021 : Providing and fixing Stainless Steel A ISI 304 (18/8) bed pan sink of approved shape and size with elbow operated sink cock as per IS 13983 with C.I. brackets and stainless steel plugs 40 mm, including painting of fittings and brackets, cutting and making good the walls etc complete as per the requirements of the site in charge including cost of conveyance, testing, commissioning, installation etc as directed by the Engineer in charge at all levels.<br>

2

-

-

... More
WATER SUPPLY ARRANGEMENTS

-

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

40

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

40

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

20

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

48

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

96

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

165

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

24

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

37

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

67

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

41

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

21

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

78

-

-

... More
od229771/2020_2021 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>62.5 inner dia pipes

51

-

-

... More
od229846/2020_2021 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>75 mm inner dia pipes

9

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

66

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

10

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

14

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

5

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

2

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

7

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

1

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

2

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

8

-

-

... More
od224574/2020_2021 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80<br>mm dia

14

-

-

... More
SANITARY ARRANGEMENT

-

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

6

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

12

-

-

... More
od231081/2020_2021 : Supplying, fixing, testing and commissioning to the satisfaction of Engineer in charge of PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and water tight C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge

6

-

-

... More
od229682/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - Internal work- Exposed on wall

100

-

-

... More
od229683/2020_2021 : Supplying and fixing GI threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.

54

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

240

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

75

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

12

-

-

... More
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

30

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

33

-

-

... More
od229690/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

7

-

-

... More
od229691/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

292

-

-

... More
od229692/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 kgf/cm2

67

-

-

... More
od229693/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110mm pipe 6 kgf/cm2

50

-

-

... More
PUMPS, FILTERS AND ACCESSORIES

-

-

-

... More
od224568/2020_2021 : :Supplying ,fixing, testing and commissioning of portable drainage pump , with stainless steel<br>construction, stainless steel impeller complete with motor which shall be IE3 as per IS 12615 and pump<br>efficiency meeting ECBC standards , with all accessories and working with 415V, 3ph and 50 Hz<br>frequency including cost and conveyance of all labour charges,lead,lift etc as directed by the<br>Engineer in<br>charge at all levels 10m3/hr, Head-15 m

1

-

-

... More
od224569/2020_2021 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller,mechanical<br>seal, complete with<br>motor which shall be IE3 rated as per IS 12615 and pump efficiency meeting ECBC<br>standards, including<br>base plate, foundation bolts, nuts,pressure gauge and all accessories. and working<br>with 415V, 3ph and<br>50 Hz frequency including cost and conveyance of all materials,labour charges etc<br>complete as directed<br>by the Engineer in charge at all levels Capacity 14.7 to 6 m3/hour ,<br>Head - 24 to 36m

6

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

6

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

3

-

-

... More
od231239/2020_2021 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <br>50 mm

6

-

-

... More
od231263/2020_2021 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm<br>Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all<br>materials,labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer

6

-

-

... More
od224570/2020_2021 : Supplying and installing activated carbon filter of size 5 cum/hr with internally<br>and<br>externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at<br>inlet and<br>outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, Vnotch<br>Board<br>etc and all other accessories .The rate shall include cost and conveyance of all materials,<br>labour etc.<br>complete and as directed by Engineer-in-Charge.

1

-

-

... More
od224571/2020_2021 : Supply and erection of dual media filter of size 0.6m dia x 1.2 m HOS, (approx.)<br>vertical<br>type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness,<br>6mm dish<br>thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves<br>and graded<br>pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure,<br>back wash<br>arrangement, etc and all other accessories .Flow rate 5m3/hr

1

-

-

... More
od224572/2020_2021 : SSupplying and fixing of electronic diaphragm type dosing pump suitable for pumping chlorine solution including cost of valve, suction and delivery lines using heavy duty PVC tubes, HDPE chlorine feed tank of 100 litres capacity etc. and complete with all accessories as directed by the Engineering<br>-Charge.<br>Capacity : 6 lph @ 3.5 kg/cm2

1

-

-

... More
od32552/2022_2023 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:<br>300 mm dia R.C.C. pipe

10

-

-

... More
od32553/2022_2023 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:<br>150 mm dia R.C.C. pipe

10

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

20

-

-

... More
od231099/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 150mm

4

-

-

... More
od231100/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 150mm

1

-

-

... More
od231101/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 100mm

8

-

-

... More
od231102/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 100mm

1

-

-

... More
od231103/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 80mm

2

-

-

... More
od231104/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 80mm

5

-

-

... More
od231106/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 65mm

12

-

-

... More
od231107/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 65mm

2

-

-

... More
od233477/2020_2021 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber fittings etc. ( The tail pieces if required will be paid separately):<br>50 mm dia nominal bore

1

-

-

... More
FURNITURE

-

-

-

... More
od306199/2023_2024 : "Revolving chairs<br>Medium back chair :-The cushioned seat assembly shall consists of moulded polyurethane foam upholstered with fabric. The foam is assembled over a 12mm thick hot pressed plywood . The back shall made up of two piece injection moulded frame. The inner frame shall be upholstered with mesh fabric and mounted on the main assembly.Lumber support made up of injection moulded in black P.P and upholstered with PU foam. Lumber support size 16 cm (W) x 9 cm (H) at fixed position Size of back shall be (W)-55cm, (H)-58.0cm & size of seat shall be (W)-50 cm x (D)-44.0cm. Armrest is fixed arm rest. The arm top is made of soft moulded PU .The mechanism of chair shall have following features:360 degree revolving type, Synchro 1 mechanism, Tilt tension adjustment. The chair shall be provided with pneumatic height adjustment which shall have stroke of 95 +/- 5 mm. The pedestal shall be made of nylon. it shall be fitted with 5 nos twin wheel castor. The size of the pedestal shall be 65.0 +/- 1 cm pitch-centre-dia (70.0 +/- 1.0 cm with castors). The twin wheel castors shall be injection moulded in PP . Overall dimensions of Chair shall be, Width of Chair - 70.0cm, Depth of Chair - 70.0 cm as measured from pedestal below. Height from ground - min 102.5 to max 111.5 cm. Seat height - min 44.5 cm to max 53.5 cm.<br>Dimensions tolerance / variations shall be within +/- 1 cm. Chair tested as per ANSI/BIFMA x5.1 standards.The product shall be of approved make and colour. The model shall be Wipro or equivalent."<br>

25

-

-

... More
od334478/2023_2024 : "Airport chair<br>Three seater perforated metal bench -Cross beam and Leg shall be powder coated made of cold rolled steelwith 0.2 ± 0.01 cm thickness. Seat-Back shell shall be 1.2 mm thk powder-coated perforated shell made from cold rolled M.S. sheet 0.12 ± 0.013 cm thickness. The Side Bar shall be made of powder-coated solid steel . The Shell shall be assembled on the Cross Beam with help of bolts . Seat width- 54.5 cm per seat. Thickness of side bars is 4.5cm & gap between seats is 2cm. Overall Dimensions shall be Seat Height - 40.6 cm, Height - 77.5cm, Width & Depth of Chair as measured from ground - Width-176.5 cm and Depth-71 cm.Dimensions tolerance / variations shall be within +/- 1 cm. The model shall be Wipro or equivalent."<br>

27

-

-

... More
od313125/2023_2024 : "Office table<br>Providing and installing Main Table: Material using Top,Leg,Front panel using IS 710 BWP Marine Plywood (Make - Archid/Century/Green Ply). Lamination using 1 MM (Make Archid Lam / Merino / Century / Greenlam). The plywood with lamination shall be hot / cold press machine required.The front panel provided at an offset of 150 MM from the outer edge. Providing Key Board Tray CPU STand & Foot Rest etc. All the visible edges are covered with 2x22MM & .5x22MM PVC Edge band wherever required.The Table fully using knockdown fittings of Mini Fix System Make - Ebco.<br>Providing 7.2 MM Golden Steel Beeding on the front panel of the same (Size considered: 150x75x75cm)"<br>

5

-

-

... More
od313905/2023_2024 : "Visitors chair<br>Visitor chair (single):Providing &amp; installing in Position Medium Back Visitor Chair with the following specifications. Seat &amp; Back shall be Fabric upholstered/Mesh Back with 100% Polyester and weighing 320 GLM. Seat Foam shall be made out of PU foam with a density 50-60 Kg/m. Base shall be Mild Steel 4 Legged base powdercoated mounted on PVC bush. The Back rest shall be of dimension 610mm (H) X 425mm (W). Seat Size shall be of dimension 455mm (W) X 480mm (D). The product shall be BIFMA compliant."<br>

43

-

-

... More
od335253/2023_2024 : "EXAMINATION TABLE SS 304<br>Features, Specification and Accessories : ● Backrest position achived by Ratchet Mechanism. ● Two sectional top made of SS304 sheet with 1mm thick. ● SS tubular frame made up of SS 304 round Pipes Ø32mm Round Pipe 18G Thickness for Legs and<br>horrizontal cross pipe of Ø25mm round Pipe of 18 thickness. ● IV Stand Provinsion Provided. ● Overall size(Approx.): 1860 L mm x 540 W mm x 810 H mm<br>● Mattress 2"" thickness& 32 density standard"<br>

2

-

-

... More
od314740/2023_2024 : "Steel rack<br>Supply and installing steel Slotted Angled Iron Rack with 6 Pannel<br>(Size considered here: 1800x900x380 cm) 20g"<br>

10

-

-

... More
od334485/2023_2024 : "Almirah <br>Material using IS 710 BWP Marine Ply Wood (Make - Archid/Century/Green Ply) Lamination using 1 MM (Make Archid Lam / Merino / Century / Greenlam). The ply wood with lamination shall be hot / cold press machine required.Interior lamination using .8 MM (Make : Archid Lam / Merino / Century / Greenlam).All the visible edges are covered with 2x22MM & .5x22MM PVC Edge band wherever required. Back Panel using 9MM thick BWP Grade marine plywood IS 710 grade marine ply wood with .8 MM thick interior lamination. Hardware using 90 Degree Soft Close Hinges , Multipurpose lock, D Handles etc Make - Ebco. Unit fully installed by knockdown fitting - Minifix system Make - Ebco Size vary from Length 80cm -240cm, Width 45CM, Hight 90cm to 210cm. Size considered here 90x45x210cm x 28 Nos"<br>

3

-

-

... More
od335254/2023_2024 : "PATIENT'S REVOLVING STOOL FULL SS 304<br>Features, Specification and Accessories : ● Round-revolving top, Ø300mm, made of SS304 sheet of 1.2mm thickness. ● Four legged stool, made of Ø25mm SS304 round tubes of 1.2mm thickness, mounted on central<br>base pipe of Ø50mm SS304 round pipe with 1.6mm thickness. ● Height adjustable by screw thread rod mechanism. ● Overall size(Approx.): 350 L mm x 350 W mm x 520- 635 H mm"<br>

5

-

-

... More
od334528/2023_2024 : "BED SIDE LOCKER ECONOMY FULL SS304<br>Features, Specification and Accessories: ● Made of SS304 tubes and sheets. ● Top made of SS 304 sheet with 1mm thick. ● Frame made of 25X25mm SS square pipe with 1.2mm thick also provide verical tubular support. ● Provided with one storage box and a door made of SS304 sheet with 1.2mm thickness. ● Overall size(Approx.) : 400 L mm x 400 W mm x 810 H mm."<br>

25

-

-

... More
od306212/2023_2024 : High back chair(x-ray department)-Chair -Highback :- The seat shall made up of plywood and moulded polyurethane foam upholstered with fabric. Backrest assembly is of injection moulded plastic with black mesh fabric and height adjustable lumbar support pad and adjustable headrest. The moulded polyurethane foam for seat is with density=50-55 kg/m ³.The dimensions of seat shall be- 48 cm(W) x 45 cm(D) and of back shall be 46.5 cm(W) x 51.5 cm(H). Armrest has button operated height adjustment. The arm top is made of soft moulded PU with MS . The mechanism of chair shall have following features:360 degree revolving type, Synchronous 1 Mechanism.The chair shall be provided with Class 4 pneumatic height adjustment which shall have stroke of 112 mm. The pedestal shall be injection moulded in black GF nylon and fitted with 5 nos twin wheel castor. The size of the pedestal shall be 65.0 +/- 1 cm pitch-centre-dia (70.0 +/- 1.0 cm with castors). The twin wheel castors shall be injection moulded in black polypropylene. The cushioned head support is adjustable in height and angle for optimum user comfort. Overall dimensions of Chair shall be, Width of Chair - 70.0cm, Depth of Chair - 70.0 cm as measured from pedestal below. Height from ground - min 92.5 to max 103.0 cm. Seat height - min 41 cm to max 51.5 cm. Dimensions tolerance / variations shall be within +/- 1 cm. Chair tested as per ANSI/BIFMA x5.1 standards.The upholstery shall be fabrics with 100% polyester.The product shall be BIFMA compliant. The product shall be of approved make and colour. The model shall be Wipro or equivalent.<br><br>

2

-

-

... More
od335256/2023_2024 : "HOSPITAL BED ECONOMY (PLANE TOP) <br>Features, Specification and Accessories : ● Plane top MS Hospital bed. ●Platform made of perforated Single section CRCA MS Sheet of 1.2mm thicknesss. ●Head and foot bows made of MS CR round tubes of Ø32mm with 1.2mm thickness with vertical<br>tube support. ●Two provisions of SS IV pole towards corners positioned diagonally. ●All MS parts chemically Pre-treated and Epoxy powder coated. ●Frame size(Approx.): 1900 L mm x 900 W mm x 560 H mm<br>●Mattress(28 density)"<br>

2

-

-

... More
od334534/2023_2024 : "Office executive table<br>Providing and installing Examination Table: Material using Top,Leg,Front panel using IS 710 BWP Marine Plywood (Make - Archid/Century/Green Ply). Lamination using 1 MM (Make Archid Lam / Merino / Century / Greenlam). The plywood with lamination shall be hot / cold press machine required.The front panel provided at an offset of 150 MM from the outer edge. Providing Key Board Tray CPU STand & Foot Rest etc. All the visible edges are covered with 2x22MM & .5x22MM PVC Edge band wherever required.The Table fully using knockdown fittings of Mini Fix System Make - Ebco.<br>Providing 7.2 MM Golden Steel Beeding on the front panel of the same Size: 150X75X75CM (Including 1 Mobile pedestal unit)"<br>

2

-

-

... More
od334533/2023_2024 : Providing and installing curtain rod frame with curtain cloth. Curtain rod using Aluminium frame with cloth upto a height of 220CM.<br>

100

-

-

... More
HT EQUIPMENTS AND DG SET

-

-

-

... More
od146566/2023_2024 : Supply, Installation testing and commissioning of 11 kV 11 m DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x50mm and supporting structure for 11 kV components with 65x65x6 mm MS angle bracings between consumer and supplier structure,cross arms, 11 kV pin,disc insulators and stay insulators, stay wire, supports, jumpering / interconnecting conductors with '0'SWG Cu, anticlimbig arrangement using barbed wire,earthing etc. on a suitable concrete foundation including the cost of foundation. The DP structure shall consists of the following (Note:All the MS items shall be hot dip galvanised)(Note:The work shall be as per KSEI & KSEB standards) 11 kV, 400A , single brake,TP, gang operated AB switch with operating handle & locking mechanism - 1 No 11 kV Lighting Arrestor -1 set of 3 Nos 11 kV DO fuses-1 set of 3 Nos .The DP structure shall be with all necessary accessories for connecting 11kV cable

1

-

-

... More
od147179/2023_2024 : DG Set - 160kVA<br> 160 KVA DG SET, Supply, Installation, Testing and Commissioning of 160 kVA prime rated D.G Set with acoustic enclosure and Control panel including reverse power relay, protection and digital metering, controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including anti vibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 160 kVA prime rating, brushless, self-excited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. The work should be as per Electrical Inspectorate/ Central Pollution control board<br>standards applicable at the time of delivery. <br><br>

1

-

-

... More
od147618/2023_2024 : UNITIZED SUBSTATION- 200KVA DRY TYPE<br>Design, fabrication,Supply, installation, testing and commissioning of indoor type Unitized Substation for 200 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram & technical specification.<br>HT Chamber <br>630A 26.2kA 11kV LBS with earth switch <br>Transformer Compartment<br>200 kVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 10% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 60/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel as per SLD<br>"The transformer shall also have suitable enclosure including supply and fixing of neutral CT of 60/5A 10VA 5P10 on earthed star point with connector for connection to Earth Fault relay in LT side. <br> LT Chamber: Suitable for terminating 1 RUN x300 sq.mm cable."<br>

1

-

-

... More
od148131/2023_2024 : "HT Metering Panel with Load Break Switch Supply, installation, testing and commissioning of HT metering Panel with 630A Load Break Switch with HT fuse and Earth switch, TOD meter (with RS485 communication facility), CTs(0.2S) and PT(0.2) , HT fuses, test terminal block, control<br>fuses, etc. The Panel shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54 with canopy, weather proof, undergone seven tank process with powder coated finish. The Panel should have seal Off bushings, space Heater with thermostat, 630A Copper busbars and support insulators, provision for earthing, all mounting accessories as required complete as per the requirement of Kerala State Electricity Board. The metering cubicle shall have glass window for meter reading."<br>

1

-

-

... More
LT PANELS AND UPS

-

-

-

... More
od147264/2023_2024 : 15KVA UPS<br>Supply, Installation, Testing and Commissioning of 15 kVA, Three phase input, Three Phase output, true on-line UPS System with 30 minutes back up , output isolation transformer, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories , cabling etc as required complete having following specification. The UPS system consist of one numbers of UPS unit and one set of battery bank .RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation, Remote Management Interphase, Back up time 30 minutes at full load

1

-

-

... More
od150217/2023_2024 : FIRE PANEL <br>Supply, Installation, Testing & Commissioning of 415V, 50Hz, LT switch board conforming to IEC 61439 Part 1&2 ( for panel fabrication) fabricated from ASTA/ASEFA/DECRA/KEMA/LOVAG/UL/CPRI/ERDA certified vendors. The enclosure shall be 2mm thick CRCA sheet , which shall be free standing with floor mounting base with suitable mounting brackets with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3b or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker. The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections<br>for control devices shall be with appropriately rated HRC fuses. The battery charger and all its components should be housed inside the control panel. The panel shall be painted with approved colour.The panel shall be suitable for TOP/BOTTOM Cable entry<br>INCOMER<br>160A, 4 Pole MCCB ISOLATOR with Digital MFM& CTsetc. LED type RYB phase indicating lamps, ON, OFF,trip indicating lamps, relays etc as per SLD <<br>160A TPN Aluminium Bus Bar <br>OUTGOING <br>(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps).<br>Main Fire Pump - 125 A, TP MCCB ISOLATOR, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.<br>Jockey Pump - 40 A TP MCCB Isolator with suitable 4kW DOL starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 32A TP MCB-1 no<br>DIESEL ENGINE CONTROL-Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication.Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays<br>and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

-

-

... More
od150218/2023_2024 : 55 kVAR APFC PANEL<br>Supply, Installation, Testing & Commissioning of fully type tested design verified 415V, 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from ASTA/ ASEFA/ DECRA/ UL/KEMA/LOVAG certified vendors and who shall be authorized panel fabricators of approved makes of OEMs. The type, size and manufacturing of enclosure shall be same as is for the design verified panel. The panel shall be free standing with floor mounting base and required base frame,<br>mounting bracket etc shall be supplied and panel shall be with following switchgears, metering instruments and accessories etc. as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3B. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports ,temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry<br>Incomer<br>125A, 25kA, FP Moulded Case Circuit Breaker with thermal-magnetic release (Ics<br>=100%Icu= 25KA).-1 no<<br>Instruments <br>4 A HRC Fuse with base , Ammeters, Voltmeters, Selector Switches, Multifunction Meters Indication Lamps, CTs , IPFC Relay as per SLD .<br>Busbar <br>125ATPN busbar chamber with Aluminium busbar.<br>Outgoing<br>63A, 25kA, TP MCCB with thermal magnetic release with OL & SC protection - 6nos.<br>32A, 25kA, TP MCCB with thermal magneticrelease with OL & SC protection - 2nos. 20kVAr capacitor duty contactor(AC6B) with illuminated ONOFF pushbuttons (LED type) -1No<br>10kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2 Nos.<br>5kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -3No.<br>20 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor - 1No<br>10 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor -2Nos<br>5 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor - 3No<br>Control wiring required for no load compensation capacitor

1

-

-

... More
od150219/2023_2024 : SB-2<br>Supply, Installation, Testing & Commissioning of fully type tested design verified 415V, 50Hz, LT switchboard conforming to IEC 61439 Part 1&2 fabricated from ASTA/ ASEFA/ DECRA/ UL/ KEMA/ LOVAG certified vendors and who shall be authorized panel fabricators of approved makes of OEMs.The type, size and manufacturing of enclosure shall be same as is for the design verified panel. The<br>panel shall be free standing with floor mounting base and required base frame, mounting bracket etcshall be supplied and panel shall be with following switchgears, metering instruments and accessories etc. as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3B or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports ,temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current<br>circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry.<br>Incomer<br>200A, 25kA, FP, MCCB with thermal magnetic based release and neutral link ( Ics = 100% Icu = 25kA) - 1no.<br>160A, 25kA, FP, MCCB with thermal magnetic based release and neutral link ( Ics = 100% Icu = 25kA) - 1no.<br>200A FP ATS with AMF relay-1 No<br>Busbar<br>200A TPN AL BUSBAR<br>Meters and instruments<br>4A, HRC fuse, Ammeters, Voltmeters, Selector Switches, Multifunction Meters indication Lamps, ON/OFF/TRIP inidication lamps, CTs, Protection Relays as per SLD .<br>SPD Type 1+2- 1No<br>Outgoings<br>100A,25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu = 25kA) -3nos.<br>63A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu =25kA) - 2nos.<br>

1

-

-

... More
od150220/2023_2024 : MSB - Supply, Installation, Testing & Commissioning of fully type tested design verified 415V, 50Hz, LT switchboard conforming to IEC 61439 Part 1&2 fabricated from ASTA/ ASEFA/ DECRA/ UL/KEMA/LOVAG certified vendors and who shall be authorized panel fabricators of approved makes of OEMs. The type, size and manufacturing of enclosure shall be same as is for the design verified panel.<br>The panel shall be free standing with floor mounting base and required base frame, mounting bracket etc shall be supplied and panel shall be with following switchgears, metering instruments and accessories etc. as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3B or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports,spacing between supports ,temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry.<br>Incomer<br>320A, 25kA, FP Moulded Case Circuit Breaker with microprocessor based release (Ics =100%Icu= 25kA).-1no<br>Busbar 320A TPN AL BUSBAR<br>Meters and instruments<br>4A HRC fuse, Ammeters, Voltmeters, Selector Switches, Multifunction Meters, indication Lamps, ON/OFF/TRIP inidication lamps, CTs, Protection Relays as per SLD .SPD Type -1 - 1 No <br>Outgoings<br>200A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu =25kA) - 3nos<br>160A,25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu = 25kA) -1no<br>125A, 25kA, TP+NL, MCCB with thermalmagnetic release and neutral link ( Ics =<br>100% Icu = 25kA) - 2nos<br>63A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral<br>link ( Ics = 100% Icu = 25kA) - 1nos

1

-

-

... More
od150221/2023_2024 : SB-1<br>Supply, Installation, Testing & Commissioning of fully type tested design verified 415V, 50Hz, LT switchboard conforming to IEC 61439 Part 1&2 fabricated from ASTA/ ASEFA/ DECRA/ UL/ KEMA/ LOVAG certified vendors and who shall be authorized panel fabricators of approved makes of OEMs.The type, size and manufacturing of enclosure shall be same as is for the design verified panel. The<br>panel shall be free standing with floor mounting base and required base frame, mounting bracket etcshall be supplied and panel shall be with following switchgears, metering instruments and accessories etc. as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3B or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports ,temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current<br>circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry.<br>Incomer<br>250A, 25kA, FP, MCCB with thermal magnetic based release and neutral link ( Ics = 100% Icu = 25kA) - 1no.<br>200A, 25kA, FP, MCCB with thermal magnetic based release and neutral link ( Ics = 100% Icu = 25kA) - 1no.<br>250A FP ATS with AMF relay-1 No<br>Busbar <br>250A TPN AL BUSBAR<br>Meters and instruments<br>4A, HRC fuse, Ammeters, Voltmeters, Selector Switches, Multifunction Meters indication Lamps, ON/OFF/TRIP inidication lamps, CTs, Protection Relays as per SLD .<br>SPD Type 1+2- 1No <br>Outgoings<br>160A,25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu = 25kA) -1no.<br>100A, 25kA, TP+NL, MCCB with thermal-magnetic release and neutral link ( Ics = 100% Icu =25kA) - 5nos.<br>160A FP MCCB Isolator- 1No

1

-

-

... More
CABLES AND CABLINGS

-

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

20

-

-

... More
8.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etcAbove 120 sq. mm and upto 400 sq. mm

5

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

5

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

5

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

3

-

-

... More
od146066/2023_2024 : Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required <br>Above 120 sq. mm and upto 400 sq. mm<br>

10

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

10

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

10

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

20

-

-

... More
14.14.4 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.300 mm dia

10

-

-

... More
14.16.1 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)

10

-

-

... More
14.16.4 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)

20

-

-

... More
14.16.5 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal)

30

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
4.6.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness

20

-

-

... More
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness

60

-

-

... More
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

15

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.7.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
4.7.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
4.8.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.8.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.8.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.8.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
4.9.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.9.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.9.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.9.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
4.10.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
4.10.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.10.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.10.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

190

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

180

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

200

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

135

-

-

... More
7.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

45

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

55

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

30

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

15

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

30

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

5

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

5

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

5

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

327

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

25

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

45

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

5

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1135

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

145

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

40

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

15

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

5

-

-

... More
9.1.3 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)

4

-

-

... More
9.1.12 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)

4

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

6

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

6

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

8

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

14

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

6

-

-

... More
od146588/2023_2024 : Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date..<br><br>3C 300 Sq. mm Al<br>

36

-

-

... More
od146639/2023_2024 : Supply of 3.5C 300 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed,<br>armoured aluminium conductor cable conforming to IS 7098 (Part 1)<br>amended upto date

20

-

-

... More
od146640/2023_2024 : Supply of 3.5C 70 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed,<br>armoured aluminium conductor cable conforming to IS 7098 (Part 1)<br>amended upto date

306

-

-

... More
od146671/2023_2024 : Supply of following 3.5C 185 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

312

-

-

... More
od146705/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.<br>2C 4 Cu

162

-

-

... More
od146742/2023_2024 : Supply of 3C 70Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed,<br>armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended<br>upto date

48

-

-

... More
od146706/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.<br>3C 4 Cu<br>

108

-

-

... More
od146707/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.<br>4C 1.5 sqmm Cu<br>

144

-

-

... More
od146708/2023_2024 : Supply of 4C 16 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed,<br>armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended<br>upto date

294

-

-

... More
od146709/2023_2024 : Supply of 4C 35 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed,<br>armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended<br>upto date

90

-

-

... More
od146710/2023_2024 : Supply of 3.5C 120 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed,<br>armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended<br>upto date

60

-

-

... More
od146712/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.<br>4C 4 Cu<br>

872

-

-

... More
od146802/2023_2024 : Supply of following 3.5C 50 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

57

-

-

... More
od146823/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.<br>2C 16Sq.mm Al<br>

132

-

-

... More
od146916/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, unarmoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.<br><br>4C 10 Sq.mm Cu Unarmored

12

-

-

... More
od146926/2023_2024 : Supplying and making end termination with copper lugs for following 4C 10<br>Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper armoured<br>conductor cable of 1.1 KV grade as required.

2

-

-

... More
od146927/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for 3C 4 sqmm Cu of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

14

-

-

... More
od146928/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for 2C 4 sqmm Cu of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

8

-

-

... More
od146929/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for 4C 4 sqmm Cu of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

56

-

-

... More
od146930/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for 4C 1.5 sqmm Cu of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

12

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

250

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

10

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

3020

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1525

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

200

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

100

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

100

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

2

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

5

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

2

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

5

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

1

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

5

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

20

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

32

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

5

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

77

-

-

... More
od143818/2023_2024 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)<br>

11

-

-

... More
od143928/2023_2024 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

82

-

-

... More
MCBs AND DISTRIBUTION BOARDS

-

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

160

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

3

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

35

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

30

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

3

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

7

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

6

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

5

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

7

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

6

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

5

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

4

-

-

... More
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
2.3.8 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+12 way, Double door

3

-

-

... More
90.14.28.2 : S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor

7

-

-

... More
od147316/2023_2024 : Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick<br>sheet steel enclosure duly painted with powder coated finishing on surface<br>including all the mounting accessories, internal wiring etc as required complete

1

-

-

... More
od147318/2023_2024 : Supplying and fixing following rating,63 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

-

... More
od147319/2023_2024 : Supplying and fixing following rating, 25 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

4

-

-

... More
od147320/2023_2024 : <br>Supplying and fixing following rating, 40 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>

2

-

-

... More
od147321/2023_2024 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65)<br>including all the necessary accessories as required complete with suitable<br>mounting arrangement.[ make Hensel : PBS 0201-H6 or equivalent approved make]

7

-

-

... More
od147322/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as<br>required.<br> 40-63A TP MCB,<br>C-CURVE<br>

6

-

-

... More
od147323/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as<br>required.<br> 40-63A FP MCB,<br>C-CURVE<br>

5

-

-

... More
od147324/2023_2024 : Supply, Installation, Testing & Commissioning of 25/32A DP MCB isolator in 1.6mm<br>thick sheet steel enclosure duly painted with powder coated finishing on surface<br>including all the mounting accessories, internal wiring etc as required complete<br>with all accessories

1

-

-

... More
od147325/2023_2024 : Supply, Installation, Testing & Commissioning of 25/32A FP MCB isolator in 1.6mm<br>thick sheet steel enclosure duly painted with powder coated finishing on surface<br>including all the mounting accessories, internal wiring etc as required complete<br>with all accessories

10

-

-

... More
od147326/2023_2024 : Supply, Installation, Testing & Commissioning of 40A FP isolator in 1.6mm thick<br>sheet steel enclosure<br>duly painted with powder coated finishing on surface<br>including all the mounting accessories, internal<br>wiring etc as required<br>complete. <br>

2

-

-

... More
od148864/2023_2024 : Providing and fixing following rating and breaking capacity and pole MCCB<br>in<br>existing cubicle panel board including drilling holes in cubicle panel,<br>making<br>connections, etc. as required.<br>100Amp,25KA,FPMCCB

2

-

-

... More
od149067/2023_2024 : Supply and fixing of 6-32A FP MCB, C-Curve following rating, 10 KA, Miniature Circuit Breakers as required

11

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

179

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

332

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

20

-

-

... More
1.42 : Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

2

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

27

-

-

... More
90.15.3.2 : Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters

10

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

16

-

-

... More
90.15.4.5 : Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

2

-

-

... More
od146898/2023_2024 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star<br>rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation:<br>B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope,<br>copper winding, Power Factor not less than 0.9, Service Value (CMM/W)<br>minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS :<br>374-2019), THD less than 10%, remote or electronic regulator unit for speed<br>control and all remaining accessories including safety pin, nut bolts, washers,<br>temperature rise=75 degree C (max.), insulation resistance more than 2 mega<br>ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic<br>regulator)

43

-

-

... More
od146899/2023_2024 : Supply of 450 mm sweep,1400 rpm heavy duty exhaust fan with self opening<br>louvers working on 230 V AC supply complete with all accessories as required.

2

-

-

... More
od146900/2023_2024 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self<br>opening louvers working on 230 V AC supply complete with all accessories as<br>required.

18

-

-

... More
od146901/2023_2024 : Supply of 400 mm size wall fan having speed control, oscillation control at bottom<br>and suitable for operation on single phase 230 volt, 50Hz AC supply complete<br>with continuous duty motor and all accessories as required complete.<br>Installation, testing and commissioning of Wall fan, including wiring the down rods of standard length with<br>1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing<br>phenolic laminated sheet cover on the fan box etc. as required.

2

-

-

... More
od146902/2023_2024 : Supply of 20W Surface/Suspended Mounted LED Batten of maximum wattage below 20W with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 4 KV internal surge protection. Power factor greater than 0.95 CCT 6500K and total harmonic distortion (THD) of less than 10% should be integral to the luminaire

61

-

-

... More
od146903/2023_2024 : Supply of 40W Surface/Suspended Mounted LED Batten with System efficacy of<br>more than 110 lm/W and lumen output of luminaire greater than 4000 lumen. LED<br>luminaire shall have sleek design with Extruded Aluminum Section. The luminaire<br>shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and<br>wider light distribution. The LED shall be compliant with LM80 standard with<br>Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80<br>and 4 KV internal surge protection. Power factor greater than 0.95 and total<br>harmonic distortion (THD) of less than 10% should be integral to the luminaire<br>

59

-

-

... More
od146904/2023_2024 : Supply of IP 65 & IK 08 LED surface mounted Bulkhead fixture with System<br>efficacy of more than 110 lm/W. Luminaire shall be made up of Die Cast<br>Aluminium for efficient heat dissipation. Luminaire shall have Polycarbonate<br>diffuser for Uniform illumination and wider light distribution. The LEDs used should<br>be with CCT of 5700 K and CRI > 70, Power factor greater than 0.95 and total<br>harmonic distortion (THD) of less than 10% including all accessories necessary as required to complete installation

5

-

-

... More
od146906/2023_2024 : Supply, installation, testing and commissioning of skirting light with all accessories as required complete

26

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

155

-

-

... More
od147059/2023_2024 : Supply of indoor recess mounted 2'X2' LED luminaire with housing made of metallic CRCA powder<br>coated body or pressure die cast Aluminium body with a high efficiency diffuser along with suitable driver<br>and surge protection, maximum system wattage of 30 Watts, luminous efficacy greater than 110<br>lumen/watt, system output >=3000lm, power factor > 0.9,rated life of L70 @ 50,000 hours, CCT-5700-<br>6500K, CRI>80, and including all necessary accessories as required complete.

6

-

-

... More
od147060/2023_2024 : Supply of 18W (+/-2), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life THD0.9, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

58

-

-

... More
od147061/2023_2024 : Supply of 10W High efficient LED batten surface/wall mounted, maximum wattage below 10w System efficacy of more than 110 lm/W and lumen output of luminaire greater than 1000 lumen, designed extruded channel in thermally conductive material with plastic with HET diffuser. CRI >80, Power factor>0.95, CCT - 6700K, 50000 burning hours as per L70 Criteria.<br><br>

33

-

-

... More
od147062/2023_2024 : Supply of 30W (+/-2) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing & High Efficiency Translucence (HET) diffuser.CRI>80, IP65 from front, Ambient temp-0 to 45DegC, 50,000 hrs @ L70life.THD<10%, Powerfactor>0.9, Surge protection-2 kV, prewired electronic driver, system efficacy > 3000 lumens, luminaire efficacy > 110 lm/W including all accessories necessary accessoriesas required to complete installation

20

-

-

... More
od147063/2023_2024 : Supplying and fixing extra conduit down rod of G.I. pipe 15 mm dia, heavy gauge including painting etc. for ceiling fans as required

65

-

-

... More
od147064/2023_2024 : Supplying and fixing Metal conduit Pipe of more than 8 mm dia, including powder coating/Spray painting similar to the colour shade of the light fixture and all accessories in complete for suspending the light fixture as required.

90

-

-

... More
od149008/2023_2024 : Installation, testing and commissioning of LED PANEL fittings with chain and copper wiring with all<br>accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement,<br>upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor<br>cable as required.

26

-

-

... More
od149009/2023_2024 : Installation, testing and commissioning of Flood light fittings on wall/Column/truss/false ceiling using<br>suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections<br>with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required

2

-

-

... More
od149010/2023_2024 : Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting<br>accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC<br>insulated stranded copper conductor as required

58

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

400

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

150

-

-

... More
od144182/2023_2024 : Supply and fixing anodised aluminum glass framed shock treatment chart.<br>

2

-

-

... More
od144183/2023_2024 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size <br>including lamination etc. as required complete on wall. <br>

2

-

-

... More
od144271/2023_2024 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm<br>for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of<br>IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of<br>1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

30

-

-

... More
od146891/2023_2024 : <br>Earthing with CI earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe<br>of 2.7 metre long etc. with charcoal/ coke and salt as required.<br>

15

-

-

... More
od147252/2023_2024 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc.as required.<br>25mm X<br>3 mm Cu

60

-

-

... More
od147254/2023_2024 : Supplying and laying 25mm X 3mm Cu strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt & spring washer spaced at 50mm)

156

-

-

... More
od147256/2023_2024 : Supplying and laying 50mm X 6mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)<br>

250

-

-

... More
od147257/2023_2024 : Providing and fixing 50mm X 6mm GI <br> GI strip on surface or in recess for connections etc. as required.<br>

60

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

855

-

-

... More
90.16.1.11 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)

110

-

-

... More
od148653/2023_2024 : Supplying of Rubber hand gloves suitable for 11 KV.<br>

2

-

-

... More
od148654/2023_2024 : Supply and fixing of First aid box <br>

2

-

-

... More
od148655/2023_2024 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size <br>including lamination etc. as required complete on wall.

1

-

-

... More
od148803/2023_2024 : Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for<br>11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of<br>IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of<br>1000mm +/- 20mm and including supply of required quantity of adhensive / compound

4

-

-

... More
LIGHTINING PROTECTION SYSTEM

-

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

120

-

-

... More
od147109/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapetwall/terrace/ roofing sheets with the required mounting clamps ,cross connectors , expansion pieceand other accessories required as per IEC 62305-3

160

-

-

... More
od147110/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the requiredmounting clamps , cross connectors , expansion piece and other accessories required as per IEC62305-3

160

-

-

... More
od147119/2023_2024 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip<br>

6

-

-

... More
SOLAR SYSTEM

-

-

-

... More
od144377/2023_2024 : Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. (Cost for 1kWp as each in unit)

15

-

-

... More
Civil works

-

-

-

... More
od148392/2023_2024 : od100710/2021_2022 :Supplying and filling the proposed yard with 40 mm size blue jelly of 150 mm thick<br>including cost and conveyance of all materials, labour charges etc. complete.<br>

6

-

-

... More
od148473/2023_2024 : Providing and fixing 1.8 meter high chain link fencing over 600 mm high random<br>rubble<br>masonry as per drawing and specification, using 4 mm thick PVC coated chain link with a<br>framework of<br>50x50x6 mm MS angle between vertical posts of ISMC 75 mm at 2400 mm interval, which<br>are fixed to the<br>concrete footing (1:2:4) of size 450x450x200 mm (above GL) with adequate footing depth,<br>between the RR<br>masonry. RR masonry (450 mm thick) and 200 mm from ground level for foundation &<br>plinth in in cement<br>mortar (1:6). The random rubble masonry is to be pointed using cement mortar 1:3 to<br>have a flush finish.<br>Earthing as per KSEI/KSEB standards shall be done around the periphery of the<br>fencing. The MS frame work<br>for chain link fencing is finished using zinc chromate primer & 2 coats of<br>synthetic enamel paint. 1.5 meter<br>wide gate shall be provided with suitable locking arrangements. The<br>rate shall be inclusive of all materials,<br>labour, lead, lift, etc including excavation works and fabrication<br>and assembly works including all nuts, bolts<br>& other miscellaneous items, etc. complete as per drawing

20

-

-

... More
MGPS

-

-

-

... More
od150420/2023_2024 : Supply,installation testing and commissioning of Automatic Oxygen Control Panel with minimum flow rate of 1000 LPM suitable for 2x4 manifold system Fully complying with ISO 10524-2, ISO 7396-1:2007/HTM02-01 as per technical specifications. The cylinders shall not be included in the quoted price.<br>

1

-

-

... More
od151043/2023_2024 : Supply,testing and commissioning of Oxygen Manifold - 2 banks x4 cylinders, as per technical specifications. The cylinders shall not be included in the quoted price.<br>

1

-

-

... More
od151149/2023_2024 : Supply,testing and commissioning of Cylinder Emergency Oxygen Manifold - 1 Bank x2 Cylinders wih high flow regulator, The cylinders shall not be included in the quoted price.<br>

1

-

-

... More
od151045/2023_2024 : NITROUS OXIDE SYSTEM: Supply,testing and commissioning of N2O Manifold with necessary Regulating System-1bank X 2 Cylinders <br>

1

-

-

... More
od151151/2023_2024 : "Supply,testing and commissioning of Cylinder Emergency N2O Out let<br> with Convertion Kit (Convertion Kit -2nos)"<br>

1

-

-

... More
od151152/2023_2024 : MEDICAL AIR SYSTEM: Supply,testing and commissioning of Compressed air plant complete with - 2 compressors, each compressor should have minimum free air delivery of 600LPM @8.5bars, 1 air receiver tank of minimum 500 ltr capacity, filtration and dryer system to ensure medical air quality as per HTM standards (each compressor module should include an inline filter with particle retention of 10 microns), NRV, pressure reducing station,automatic drain valves,pressure guages,ball valves, electrical control panel including circuit breakers, starters, pressure switches, timers, as per technical specifications.<br>

1

-

-

... More
od151153/2023_2024 : VACUUM PLANT: Supply,testing and commissioning of Vacuum plant complete with 1 vacuum pump and one as standby, each vacuum pump should have minimum free air aspirated of 900 LPM betwen 570 mmHg and 720 mm Hg.min, vaccum receiver tank of minimum 1000 ltr capacity,bacteria double filter, valves,pressure guages,NRV, electrical control panel including circuit breakers, pressure switches, timers, ball valves etc as per technical specifications.<br>

1

-

-

... More
od151154/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-12 mm x 1 mm thick Copper pipe<br><br>

120

-

-

... More
od151155/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications- 15 mm x 0.9 mm thick Copper pipe <br><br>

445

-

-

... More
od151156/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-22mm x 0.9 mm thick copper pipe<br><br>

195

-

-

... More
od151222/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-28 mm x 0.9 mm thick copper pipe<br><br>

45

-

-

... More
od150637/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications- O2 Outlets with Probes<br><br>

35

-

-

... More
od150638/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-N2O Outlets with Probes<br> <br>

1

-

-

... More
od150640/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Air (4 bar) Outlets with Probes<br> <br>

25

-

-

... More
od150981/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Air (7 bar) Outlets with Probes<br> <br>

3

-

-

... More
od150641/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications- Vac Outlets with Probes<br><br>

30

-

-

... More
od151245/2023_2024 : "Supply,testing and commissioning of Master Plant Alarm Panel ,Complies with HTM 02-01/ISO<br>7396-1 Standards. Each Master Alarm should be modular in design and be fitted with required number of master alarm modules. The master alarms should be capable to monitor minimum 25 point. Each point represents an alarm condition that the source equipment might have. When an alarm condition exists, a red-light flashes and the audible alarm sounds. If several alarm conditions occur simultaneously, the most recent alarm light should flash, while the other alarm lights should remain lit. When an alarm condition is generated, an audible alarm should be actuated. A dry contact module should be available to interface with a building management system. The box material should be of gauge steel of requisite thickness and equipped with mounting brackets. The emissions from alarms should conform with EMC standards. Master alarm management system should be designed to display alarm conditions from the source supply units indicating the broad status of the source equipment and manifolds as well as the master distribution status from the source supplies. Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. Each panel shall display and/or input of multi point alarms,including all necessary cabling between mater alarm and floor panels. The master alarm must be able to monitor the following source alarm conditions. as per technical specifications."<br>

1

-

-

... More
od151246/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-5 gas - 1 O2,1N2O,1M air1Sair,1Vac<br> <br>

1

-

-

... More
od151247/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-3 gas - 1 O2, 1M air, 1 Vac<br> <br>

3

-

-

... More
od151284/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications -15 mm<br><br>

25

-

-

... More
od151231/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications -22 mm<br><br>

16

-

-

... More
od151232/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-28mm<br><br>

6

-

-

... More
od151233/2023_2024 : Supply,testing and commissioning of class J type Oxygen Gas filled Cylinder etc in complete as per technical specification.<br>

9

-

-

... More
od151249/2023_2024 : Supply,testing and commissioning of J type Nitrous Oxide Gas filled Cylinder as per technical specification.<br>

3

-

-

... More
od151251/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge-Bed head panel as above with 3 Gas outlet<br><br>

15

-

-

... More
od151252/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge-Bed head panel as above with 5 Gas outlet<br><br>

9

-

-

... More
od151253/2023_2024 : Supply Installation of BPC Oxygen Flow meter as per technical specification.<br>

24

-

-

... More
od150824/2023_2024 : Supply Installation of Ward vacuum unit with 600 ml collection jar asper technical specification.<br>

24

-

-

... More
od150825/2023_2024 : Supply Installation of Theatre Vacuum unit with trolly and 2000 ml collection jar as per technical.<br>

3

-

-

... More
od150826/2023_2024 : Supply,Installation,testing and commissioning of High Pressure Antistatic Hose with color coded.<br>

12

-

-

... More
HVAC Equipments

-

-

-

... More
od140223/2023_2024 : Supply, Installation, Testing and Commissioning of minimum 5.5 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. The item shall be complete in all respects complying with technical specifications.

2

-

-

... More
od140224/2023_2024 : Supply, Installation, Testing and Commissioning of minimum 4 TRcapacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. The item shall be complete in all respects complying with technical specifications.

2

-

-

... More
od140225/2023_2024 : Supply, Installation, Testing and Commissioning of minimum 3 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od140226/2023_2024 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 2200 CFM (5.5 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.

2

-

-

... More
od140227/2023_2024 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 1600 CFM (4.0 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.

2

-

-

... More
od140228/2023_2024 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 1200 CFM (3.0 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od140230/2023_2024 : Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 5.5 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ requirements, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications

20

-

-

... More
od140231/2023_2024 : Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 4.0 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications

23

-

-

... More
od140232/2023_2024 : Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 3.0 TR machine between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications

14

-

-

... More
od140233/2023_2024 : Supply, Installation, Testing and Commissioning of minimum 1.0 TR capacity Decorative(Hi wall) Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and indoor units for single phase 230 V supply minimum 5 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) between indoor & outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth with required pipe fittings and accessories like bends, tees, reducers, supports complete, necessary power/control cabling as required, suitably supported on trays/ split clamps etc., PVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, finished with 7 mils factory laminated treated fibre glass cloth, first charge refrigerant gas R410A/R407C, cordless remote etc. The item shall be complete in all respects complying with technical specifications.

3

-

-

... More
od116416/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel, Vibration isolator, other required accessories etc. complete in all respects as per the technical specifications:<br>1000CFM -15 mm WG ESP

1

-

-

... More
od116417/2021_2022 : Supply, installation, testing and commissioning of suitable dia PVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth along with required pipe fittings and accessories like Bends, Tees, reducers, clamps, suitably supported including chasing, drilling, concealing and making good the same on walls and replastering of cut wall with good finish etc.complete in all respects as per the technical specifications.

35

-

-

... More
Air Distribution System

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

186

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

12

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

5

-

-

... More
od140241/2023_2024 : Supply, Installation, testing, and commissioning of Air-Distribution Network made out of suitable thick (gauge) Aluminium sheet for Supply air, Return air, Exhaust Air, Fresh Air rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. associated accessories, supports etc. for critical rooms(X-Ray /MRI/CT room etc.) application and as per relevant SMACNA standards etc. The item shall be complete in all respects complying with technical specifications.

36

-

-

... More
od380442/2023_2024 : DSR 16.23.1 Supplying and fixing of suitable thick closed cell nitrile rubber insulation (Class O) with factory laminated aluminium FSK facing of 12 micron to meet minimum R value of 0.6 m2/KW. complete in all respects as per the technical specifications.

210

-

-

... More
od140239/2023_2024 : Supply, Installation, testing and commissioning of Acoustic Insulation of ducts using open cell nitrile rubber having a density of 140-180 kg/m3 and thickness of 10 mm with anti-microbial protection as per EN ISO 846 Method A etc along with manufacturer recommended adhesive where the VOC level should not exceed more than 850 grams / Litre as per IGBC/ GRIHA. Insulation material shall be GRIHA Approved and CFC, HCFC free. Insulation shall be dust and fibre free, complete in all respects as required by the technical specification

68

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

3

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

3

-

-

... More
od116522/2021_2022 : Supply, Installation , testing and commissioning of Aluminium extruded fresh air louvers with fresh air damper,bird screen etc. complete in all respects as per the technical specifications..

1

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

3

-

-

... More
od116532/2021_2022 : Supply, Installation, testing & commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for Air Distribution Networks complete in all respects as per the technical specifications.

3

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od111369/2023_2024 : Supply, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, end suction, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal having rated flow of 2280 lpm at 56m approximate head, conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor conforming to IS 12615 specifications, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered along with anti vibration pads/mounts.

1

-

-

... More
od111372/2023_2024 : Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification.(a) Horizontal, end suction, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal having rated flow 2280 lpm at 56m head, conforming to IS 1520.(b) Suitable HP, suitable RPM water cooled radiator type diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,12v 180AH Battery and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity for 8 hour operation) with level indicator, Bypass line, piping from diesel tank to engine, exhaust pipe extended upto 1m outside pump house duly insulated with 50 mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads/ mounts. (e) Diesel engine control panel.

1

-

-

... More
od111377/2023_2024 : Supply, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as pertechnical specification. (a) Vertical Inline pump of stainless steel body and stainless steel impeller withstainless steel shaft, mechanical seal having rated flow of 180 lpm at 56m head conforming to IS 1520 having minimum mechanical efficiency of 75%.(b) Suitable HP Squirrel cage IE3 induction motor conforming to IS 12615 specifications, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation.

1

-

-

... More
od111381/2023_2024 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

3

-

-

... More
od111384/2023_2024 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC, with ball valve etc. complete as required as per technical specification.

3

-

-

... More
od111388/2023_2024 : Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
od111614/2023_2024 : Supply, Installation, Testing and Commissioning of 200 mm nominal dia (6.3 mm thickness) MS(Heavy C' Class) pipe IS: 3589 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

24

-

-

... More
od111392/2023_2024 : Supply, Installation, Testing and Commissioning of 150 mm nominal dia<br>MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and<br>accessories such as elbows, flanges, tees, reducers etc. conforming to IS<br>standards complete including painting, welding, jointing and neoprene gaskets,<br>nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

115

-

-

... More
od111393/2023_2024 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia<br>MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and<br>accessories such as elbows, flanges, tees, reducers etc. conforming to IS<br>standards complete including painting, welding, jointing and neoprene gaskets,<br>nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

55

-

-

... More
od111395/2023_2024 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete<br>including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as<br>required. (for fire hydrant and sprinkler system). The pipe shall be painted with<br>one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

12

-

-

... More
od111397/2023_2024 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

48

-

-

... More
od111398/2023_2024 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

25

-

-

... More
od111399/2023_2024 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

109

-

-

... More
od111400/2023_2024 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

9

-

-

... More
od111401/2023_2024 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

336

-

-

... More
od111402/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 150 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

120

-

-

... More
od111403/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings like<br>elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

7

-

-

... More
od111404/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of<br>150 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body<br>complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

2

-

-

... More
od111405/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of<br>100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body<br>complete with all accessories including flanges, rubber gasket, bolts, nuts,<br>washers etc. complete as required.

1

-

-

... More
od111406/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of<br>65 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body<br>complete with all accessories including flanges, rubber gasket, bolts, nuts,<br>washers etc. complete as required.

1

-

-

... More
od111633/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 200 mm<br>diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc complete as required as per the technical specification and conforming to IS 13095.

2

-

-

... More
od111407/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 150 mm<br>diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

8

-

-

... More
od111408/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 100 mm<br>diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

7

-

-

... More
od111409/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 80 mm<br>diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

1

-

-

... More
od111410/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 65 mm<br>diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

1

-

-

... More
od111411/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 40<br>mm<br>diameter, PN 16, with Cast iron/Carbon steel body complete with all<br>Accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

4

-

-

... More
od111412/2023_2024 : Providing, installation, testing and commissioning of 150 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

2

-

-

... More
od111413/2023_2024 : Providing, installation, testing and commissioning of 80 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od111414/2023_2024 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification.

7

-

-

... More
od111415/2023_2024 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS<br>construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical<br>specification.<br>(a) 30 m. long 20 mm (nominal internal dia water hose<br>Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal<br>internal ) dia gun metal globe valve & nozzle.<br>(c) Drum and brackets for fixing the equipments on wall.<br>(d) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. Pipe

4

-

-

... More
od111416/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

14

-

-

... More
od111417/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch<br>pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

7

-

-

... More
od111418/2023_2024 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

7

-

-

... More
od111419/2023_2024 : Supply, installation, testing and commissioning of 4-WAY FIRE BRIGADE inlet connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

2

-

-

... More
od111420/2023_2024 : Supply, installation, testing and commissioning of draw off connection with CI body and gunmetal coupling, complete with GI nuts, bolts, gasket etc as required as per technical specification.

1

-

-

... More
od111421/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response,<br>standard coverage pendant type sprinkler;1/2" NPT, K -5.0, Chrome Finish with<br>rosetter plate; operating temperature at 68 degC complete as required as per the technical specification.

47

-

-

... More
od111422/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response,<br>standard coverage upright type sprinkler ;1/2" NPT, K -5.0, Chrome Finish;<br>operating temperature at 68 degC complete as required as per the technical<br>specification.

93

-

-

... More
od130425/2023_2024 : Supply, installation, testing and commissioning of 700 mm braided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc as required as per technical<br>specification.

47

-

-

... More
od111423/2023_2024 : Supply, installation, testing and commissioning of 1m unbraided flexible<br>connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc and other accessories as required as per the technical specification.

5

-

-

... More
od111424/2023_2024 : Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm<br>valve of Cast iron body and bronze working parts comprising of water motor<br>alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical<br>gong bell to sound continuous alarm when the Wet riser/Sprinkler system<br>activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification.

1

-

-

... More
od111425/2023_2024 : Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 complete with all accessories as required as per the technical<br>specification.

4

-

-

... More
od111426/2023_2024 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia,<br>complete as required as pet the technical specification.

1

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od111368/2023_2024 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs<br>Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS<br>14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

9

-

-

... More
od111375/2023_2024 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg<br>capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

4

-

-

... More
od111379/2023_2024 : Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

3

-

-

... More
od130541/2023_2024 : Supply, installation, testing and commissioning of Modular (Cealing mounted) ABC type extinguisher of 5Kg complete as required with all necessary accessories for successful operation as required as per the technical specification.

4

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
od111371/2023_2024 : Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke & heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

102

-

-

... More
od111374/2023_2024 : Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

8

-

-

... More
od111378/2023_2024 : Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio<br>and visual indication complete with all fixing accessories, base box etc. under<br>false ceiling, roof, wall, etc, as required as per the technical specification. The<br>product shall be EN/UL/FM/LPCB approved/ listed.

8

-

-

... More
od111380/2023_2024 : Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

10

-

-

... More
od130507/2023_2024 : Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring and control, as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

4

-

-

... More
od111387/2023_2024 : Supply, installation, testing and commissioning of addressable relay module to automatically trigger on/off 3rd party devices like fire damper, jet fans, extract air fans etc in case of fire, complete with all accessories as required as per the technical specification. The product shall be UL listed and FM Approved.

4

-

-

... More
od111389/2023_2024 : Supply, installation, testing and commissioning of 24V Power supply unit for hooters with battery backup. The status of the power supply unit must be monitored from the FACP and alarm shall be obtained if the power supply unit fails to operate, complete in all respect with necessary accessories as required as per the technical specification.

1

-

-

... More
od111390/2023_2024 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

8

-

-

... More
od111391/2023_2024 : Supply, installation, testing and commissioning of public address and talk back system consisting of 10 zone public address cum talk back console with mike and selector, multiple channel talk back facility, power supply, battery charger, battery housing, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier, and suitable capacity battery (min 12V), etc. complete as required for meeting the technical specifications.

1

-

-

... More
od111394/2023_2024 : Supply, installation, testing and commissioning of EN/UL/FM/LPCB approved/<br>listed, microprocessor based intelligent addressable main fire alarm panel having suitable number of loops to connect all the devices as per BOQ in single panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to integrate with analog/digital voice evacuation system (PA-talkback system) and shall be complete with all necessary accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities.<br>a) Programming software for the system<br>b) Automatic system test activates<br>c) Detector sensitivity adjustments<br>d) Alarm verification<br>e) Alpha/numerical display<br>f) Provision to connect to PCs and external printers.

1

-

-

... More
od111396/2023_2024 : Supply and laying of 2x1.5 sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground,on wall surface or recess as required as per the technical specifications.

1681

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

80

-

-

... More
SIGNAGES

-

-

-

... More
od111370/2023_2024 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

14

-

-

... More
od111373/2023_2024 : Supply and installation of photoluminescent glow signage for "FIRE ASSEMBLY POINT" of standard size (500*225 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

1

-

-

... More
od111376/2023_2024 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws &double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

8

-

-

... More
od111383/2023_2024 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

8

-

-

... More
od111385/2023_2024 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

4

-

-

... More
ELEVATOR SYSTEM

-

-

-

... More
od111256/2021_2022 : Design, fabrication, supply, installation, testing and commissioning of electric traction type with machine room type , Stainless steel 26 Pax (1768 Kg) Hospital elevator with car size of 1600 mm (width) x 2400 mm (depth) (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc- except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,braille buttons,audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required.The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor(IE 3 or better efficiency) of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specification. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details:-4 stops & 4 openings and entrance & exit at same side and suitable for travel height of 12.3 mtrs. (Shaft Size 2400mm (width) x 3000mm (depth) ) with door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible .All components, fabrication and procedures of elevator system shall confirm to relevant IS standards/ Code and complete in all respects as per technical specifications

1

-

-

... More
STRUCTURED CABLING AND ACTIVE DEVICES

-

-

-

... More
od108239/2021_2022 : Supply, installation, testing and commissioning of U/UTP cable - Category 6A, 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with fluke cable analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification

1435

-

-

... More
od108244/2021_2022 : Supply, installation, testing and commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with fluke cable analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification

1190

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

900

-

-

... More
od108251/2021_2022 : Supply and installation of concealed GI metal backbox with all accessories required at site to complete the work as per technical specification

44

-

-

... More
od108256/2021_2022 : Supply, installation, testing and commissioning of Cat6A information outlet, RJ 45 with all accessories required at site including termination complete as per technical specification

41

-

-

... More
od108258/2021_2022 : Supply, installation, testing and commissioning of Cat6 information outlet, RJ 45 with all accessories required at site including termination to complete the work as per technical specification

25

-

-

... More
od108259/2021_2022 : Supply, installation, testing and commissioning of Cat6A 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification

2

-

-

... More
od108260/2021_2022 : Supply, installation, testing and commissioning of Cat6 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification

2

-

-

... More
od108261/2021_2022 : Supply, installation, testing and commissioning of single or dual shuttered faceplate with all accessories required at site to complete the work as per technical specification

44

-

-

... More
od108262/2021_2022 : Supply, installation, testing and commissioning of Cat6A patch cord - 2m with end termination and all accessories required at site to complete the work as per technical specification

46

-

-

... More
od108263/2021_2022 : Supply, installation, testing and commissioning of Cat6 patch cord - 2m with end termination and all accessories required at site to complete the work as per technical specification

34

-

-

... More
od108264/2021_2022 : Supply, installation, testing and commissioning of Cat6 patch cord - 1m with end termination and all accessories required at site to complete the work as per technical specification

25

-

-

... More
od108265/2021_2022 : Supply and installation of PVC casing capping with all accessories required at site to complete the work as per technical specification.

20

-

-

... More
od108266/2021_2022 : Supply, installation, testing and commissioning covered GI unperforated cable tray with 200 mm width x 50 mm depth x 1.6 mm thickness (ISI Grade) with thread road, anchor fastener, nut, washer, etc. including all necessary accessories as required at site to complete the work as per technical specification

100

-

-

... More
od108267/2021_2022 : Supply, installation, testing and commissioning of 24 port Layer 2 Stackable switch with 24 x 10/100/1000Base-TX ports and 2 x 10G Copper / SFP+ ports including all necessary hardware, accessories, etc. as required at site to complete the work as per technical specification

2

-

-

... More
od108268/2021_2022 : Supply, installation, testing and commissioning of 24 port Layer 3 Core Switch with min 12 x 10/100/1000Base-TX ports and min 4 x 10G Copper / SFP+ ports including all necessary hardware, accessories, etc. as required at site to complete the work as per technical specification

1

-

-

... More
od108269/2021_2022 : Supply, installation, testing and commissioning of next generation Firewall having a capacity of handling 100 concurrent users with logs, monitoring, bandwidth management, security subscriptions, including software, licenses and all accessories required at site to complete the work as per technical specification

1

-

-

... More
od108270/2021_2022 : Supply, installation, testing and commissioning of 42U Network Rack (800mmx1000mm) along with all necessary hardware, accessories, etc. as required at site to complete the work as per technical specification

2

-

-

... More
IP-PBX

-

-

-

... More
od108238/2021_2022 : Supply, installation, testing and commissioning of IP-PBX system with 2PRIs and 10 channel SIP trunk licenses, expandable up to 120 IP extensions, including all hardware, software, 1 no of desktop based operator console, with all accessories required at site to complete the work as per technical specification

1

-

-

... More
od108245/2021_2022 : Supply, installation, testing and commissioning of licence for IP extensions with all accessories required at site to complete the work as per technical specification

24

-

-

... More
od108248/2021_2022 : Supply, installation, testing and commissioning of Standard IP Phones with all accessories as required at site to complete the work as per technical specification

24

-

-

... More
od108253/2021_2022 : Supply, installation, testing and commissioning of 24 port Layer 2 PoE+ Stackable switch with 24 x 10/100/1000Base-TX PoE+ ports and 2 SFP ports including all accessories required at site to complete the work as per technical specification

2

-

-

... More
IP SURVEILLANCE

-

-

-

... More
od108243/2021_2022 : Supply, installation, testing and commissioning of 2MP varifocal IP camera, PoE, IP66 rated with all accessories as required at site to complete the work as per technical specification

9

-

-

... More
od108247/2021_2022 : Supply, installation, testing and commissioning of 24 port Layer 2 PoE+ switch with 24 x 10/100/1000Base-TX PoE+ ports and 2 SFP ports including all accessories as required at site to complete the work as per technical specification

1

-

-

... More
od108249/2021_2022 : Supply, installation, testing and commissioning of 16 channel Network Video Recorder, SAS/Enterprise HDDs, RAID5 with 30 days storage, all required hardware including a desktop, cabling and accessories as required at site to complete the work as per technical specification

1

-

-

... More
od108254/2021_2022 : Supply, installation, testing and commissioning of 55" commercial display, 24/7 with HDMI and USB ports including all accessories as required at site to complete the work as per technical specification

1

-

-

... More
ATTENDANCE SYSTEM

-

-

-

... More
od108242/2021_2022 : Supply, installation, testing and commissioning of biometric, password and proximity card based Attendance Machine with software and all accessories as required at site to complete the work as per technical specification

1

-

-

... More
PUBLIC ADDRESS AND EVACUATION SYSTEM

-

-

-

... More
od108241/2021_2022 : Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm

740

-

-

... More
od108246/2021_2022 : Supplying, installation, testing and commissioning of 1.5/3/6W ceiling speaker complete as required.

20

-

-

... More
od108250/2021_2022 : Supplying, installation, testing and commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

17

-

-

... More
od108255/2021_2022 : Supply, installation, testing and commissioning of PA system Controller capable of managing up to 6 individual zones with BGM, announcement and automatic emergency message facility with integration to Fire alarm system with all accessories as required at site to complete the work as per technical specification

1

-

-

... More
od108257/2021_2022 : Supply, installation, testing and commissioning of Paging Microphone with multi tone chime and multichannel zone selector including all accessories as required at site to complete the work as per technical specification

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.