Kerala Electrical And Allied Engineering Company Limited Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 15,300Document Cost
₹ 2,950Tender Fee
Refer Documents
Summary
Supply And Installation Of Mini Low Mast Lights
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KEL_758754_2Bid Award Id
ViewTender No
KEL/FL/MMD/K01/EPROC/25-26Tender Authority
Kerala Electrical And Allied Engineering Company Limited ViewPurchaser Address
-Website
http://https://www.kel.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of
sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and
or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and
disposal of surplus excavated soil as directed, within a lead of 50 metres
14
-
-
... More
Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc.
including form work etc. as required
9.5
-
-
... More
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of High
Mast/Mini Mast/DG set etc. including form work etc. as required (including reinforcement)
3.36
-
-
... More
Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels.
2.75
-
-
... More
Supply, conveyance and erection of the following sizes of 'B' class GI
pipe in single section for post top lantern of all types on concrete base (excluding
charges for concrete base and excavation) and painting with 2 coats of synthetic
enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe
28
-
-
... More
Supply and drawing the following sizes of multi-core PVC insulated & FRLS
PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming
to IS 694 part I 1960 in the existing surface / recess conduit as required including
giving necessary connections of the following sizes.4 core 2.50 sq mm
140
-
-
... More
Supply & laying of one number PVC insulated and PVC sheathed armoured
aluminium power cable of 1.1KV grade of the following sizes in ground including
excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but
excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
70
-
-
... More
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level
including excavation50/38 mm or nearest size
14
-
-
... More
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
100
-
-
... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing
cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty
GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages,
colour washing etc. as required ( for horizontal run)20 x 3 mm GI strip
70
-
-
... More
Supplying and making end termination with brass compression gland and aluminium
lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
28
-
-
... More
32/63 A fuse holder for BS type blade fuses
14
-
-
... More
32/63 A, 230 V, DIN type fuse base
14
-
-
... More
32/63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
14
-
-
... More
Supply and providing Single dial timer unit analog type with contactor and relay
14
-
-
... More
Fabrication, supply & installation of dust and vermin proof, wall mounting,
Sintex make Code No 3525 meter box suitable for fixing KSEB meter,fuse units,
hinged door construction for the front side with compartments if necessary, providing
vision panel for the meter compartment, knock out for cable entry and exit
14
-
-
... More
Preparation of all drawing submitting and approvel from KSEB, obtaining power
allocation, submitting of completion certificates and arranging inspection, getting
sanction and energisation certificates from KSEB and obtaining power connection
(single phase connection) etc: for commissioning of the whole installation in the
permises.
14
-
-
... More
Supply and providing pipe earthing as per IS 3043 with 2.6 m long 40 mmdia B
class GI pipe,GI funnel with weld mesh,filling required quantity of
charcoal&:salt including construction of1:4:8 PCC using 40 mm broken
stone(10 cm thick) brick work in mortar1:6,plastering the surface of brick masonary
and the exposed surface of PCC bed with cement mortar1:4:12 mm thick(the finished
inside dimension shall be 300X300X300.
14
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as
required.Single pole
14
-
-
... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
14
-
-
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240
volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as
required.25 amps