The Infopark has issued a formal invitation for competitive bids for Fire Alarm System Work In Athulya Building At Infopark Kochi Phase I in Ernakulam, Kerala, with an estimated contract value of Rs. 46,57,677. The bid opening date for this tender is 20-03-2025 and the last date for bid submission is 04-04-2025. Interested bidders for Infopark tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 50,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_INFOP_752802_1Bid Award Id
ViewTender No
Infopark/ e-Tender / 043 / 2024-25Tender Authority
Infopark ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
62
-
-
... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
255
-
-
... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2km, network communication card, minimum 320 character graphics/LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM),powder supply unit (230 +/- % V,50hz), 48 hrs back -up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility ti connect printer to printout log and facility ti have seamless integration with analog/digital vice evacuation system (which is part of the schedule integration with analog/digital voice evacuation system (which is part of the schedule of work under SH:PA System) and shall be complete with all accessories. The panel shall be complete with all accessories. The panel shall be compatible fir IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications.
one Loop Panel Location : Substation and MLCP
Note : Shop drawing to be prepared and same was approved by Infopark before commencement of work. After completion of work, as fitted drawing to be prepared and submitted to Infopark
2
-
-
... More
Checking the healthiness / continuity of existing cable from the exisiting fire alarm panel / device to device at substation, MLCP, SDB - 1st floor to terrace floor Note ; Maximum existing cable will be use, only change the dedector
1
-
-
... More
Supply,Installation,Testing & commissioning of fault isolator complete with base as required
38
-
-
... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (Outer colour of cable will be in Red)
3350
-
-
... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2km, network communication card, minimum 320 character graphics/LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM),powder supply unit (230 +/- % V,50hz), 48 hrs back -up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility ti connect printer to printout log and facility ti have seamless integration with analog/digital vice evacuation system (which is part of the schedule integration with analog/digital voice evacuation system (which is part of the schedule of work under SH:PA System) and shall be complete with all accessories. The panel shall be complete with all accessories. The panel shall be compatible fir IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications.
Two Loop Panel Location : Cafeteria & SDB
Note : Shop drawing to be prepared and same was approved by Infopark before commencement of work. After completion of work, as fitted drawing to be prepared and submitted to Infopark
2
-
-
... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
461
-
-
... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
62
-
-