Indian Institute Of Information Technology And Management Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Indian Institute Of Information Technology And Management - IIITM Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Apr 2025
Closing Soon10 May 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

9

-

-

... More
od208635/2024_2025 : Supply and fixing stainless steel cockroach trap for 110mm dia floor trap complete in all resect.

175

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1596

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1725

-

-

... More
od212619/2024_2025 : Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification - For 20 mm dia Pipe 6 mm thick

301

-

-

... More
od42048/2023_2024 : Supplying, installation, testing & commissioning of addressable fire control module complete as required.

21

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

140

-

-

... More
18.9.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work100 mm nominal inner dia pipes

23

-

-

... More
od221622/2024_2025 : LT CABLES: ALUMINIUM CABLE: Supply of the following size cable, heavy duty armored XLPE insulated and sheathed, as per ISI mark, 1100 volts grade aluminum stranded conductor cable of size as below all as specified - 3.5 Core 70 Sq.mm.

32

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

127

-

-

... More
1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire

980

-

-

... More
12.22 : Making Khurras 45x45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete.Making Khurras 45x45 with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) and a coat of near cement, rounding the edges, making and finishing the outlet complete.

12

-

-

... More
od208633/2024_2025 : Providing and fixing UPVC trap ('P' or 'S') of self cleaning design with or without vent horn complete, as shown in detailed drawing including inlet fitting wherever required including cost of cutting and making good the walls & floors: 110 mm inlet and 110 mm outlet

175

-

-

... More
13.41.1 : Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work ( Two or more coats) over and including priming coat with water thinnable cement primer

1279.08

-

-

... More
od225464/2024_2025 : NETWORKING SYSTEM (ACTIVE): Supplying, installing, testing and commissioning of IP phone Type-1 as per specification including all necessary items to connect with existing system (Including License) (for Medical Officer room).

1

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

525

-

-

... More
od224273/2024_2025 : Supply, installation, testing and commissioning of powder coated extruded Aluminum fresh air louvers with Aluminum bird screen and volume control damper as per specifications.

0.45

-

-

... More
od217918/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes - Self-Contained battery 90 min power backup Recessed Mounted LED Downlight - 10 Watt

12

-

-

... More
od221790/2024_2025 : SITC of Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- SS, Conductor leading- loose, Conductor holder support Rd- 8 mm With accessories Screw and Gitty, Material SS (M5 x 50mm)

275

-

-

... More
12.41.2 : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

37

-

-

... More
Civil Work

-

-

-

... More
od208624/2024_2025 : Fixing &commissioning of 15mm CP brass single lever concealed bath and shower wall mixer with divertor with 3 way shower head, spout, OH shower with adjustable type arm with wall flange with slip fit connection. (Low Flow Green Fixture 6.0 lpm)

137

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

2487.32

-

-

... More
9.40.2.2 : Kiln seasoned and chemically treated hollock wood50x20 mm

1174.88

-

-

... More
od213769/2024_2025 : Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coal tar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required: 150 mm dia

100

-

-

... More
od202071/2024_2025 : NON FIRE RATED METAL(MS) DOOR :-Supplying and fixing 46mm thick (at any level) of Factory made MS non fire rated Door Shutter having 1.2 mm thick sheet both side, C channel supported by sufficient stiffener as per drawing with Frame Pressed Galvanized steel confirming to IS 277 having 1.6mm thick sheet including Transfer grill, vision panel, finishing with paint over primer fittings & fixture and including all necessary Hardware ,as per Drawing & Design with the direction of Engineer in Charge complete in all respect. (Sample of each Door Should be approved before procurement)

5

-

-

... More
od208617/2024_2025 : Providing and fixing wash basin with C.I. brackets, Basin Mixer Low Flow/ Green Fixture 2.5 lpm ,32 mm C.P. brass waste, 32 mm CP. Bottle trap and unions of standard pattern including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm

151

-

-

... More
od222267/2024_2025 : LT PANEL: SMDBGFL, SMDB1FL, -FLOOR/WALL MOUNTED (ELECTRICAL ROOM)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>1 no. 100A 4P MCCB,25KA, Thermomagnetic controlled.<br>1Set of 100/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>Bus Bar<br>4 Strip aluminium bus bar of 100 A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 25 KA fault - 1 set<br>Outgoing<br>5 nos. 40A 4P MCCB,25KA, Thermomagnetic controlled.<br>5 Set of 40/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>5 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

2

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

12

-

-

... More
od225635/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supplying, installing, testing and commissioning of 24-Port Category 6 Patch Panel,1.75”-High - Voice As per Specification.

3

-

-

... More
od214142/2024_2025 : Providing & fixing fire authority approved M.S. hose door (size 900 (L) x 2100 (H)) made out of 16 SWG powder coated M.S. sheet Angle frame capable of accommodating fire hose reel, fire hydrant, hose pipe, fittings & accessories. The box shall have a single or double glazed front glass door (with 4 mm thick glass) with lock & key arrangement & shall be painted with Fire red as per IS:5, shade no. 536. (Location : For Internal Hydrant)

7

-

-

... More
od213773/2024_2025 : Terrace Pump: Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) - (A) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 - (B) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. - (C) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. - (D) Suitable cement concrete foundation duly plastered and with anti vibration pads.<br>900 lpm at 35 m Head

1

-

-

... More
1.55.2 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B

696

-

-

... More
18.77 : Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.

200

-

-

... More
od42067/2023_2024 : Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required

50

-

-

... More
od198536/2024_2025 : Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Liters per sq. m. of the surface before sand bed or sub-grade is laid. Holes up to 50 mm. to 75 mm. deep at 150 mm. center to center both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurement will be per Sqm of plan area of plinth treated.)

691

-

-

... More
1.14.5 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire

40

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

3

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

37

-

-

... More
12.42.6.2 : Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionShoe (Plain)110 mm Shoe

6

-

-

... More
od152553/2024_2025 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof - After height of 19m to 22m

308.44

-

-

... More
od245476/2024_2025 : SITC of GI flat (25x6mm) for interconnection of earth pit & termination to earth pit Weight 1.2 kg/m (approx.) Cross Section 150 mm2 ,Coating thickness Avg. 70 microns. As per IEC 62561-2:2018, Material Hot dipped Galvanized Iron

270

-

-

... More
od199142/2024_2025 : Providing and fixing SS Aldrap of approved design with necessary nuts & screw etc. complete in all respect: 16mm dia bolt x 250 mm long

108

-

-

... More
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

304.8

-

-

... More
od208636/2024_2025 : Providing, fixing, testing & commissioning of 110mm x 63mm uPVC Reducing Elbow for floor drain point and coupler cutting chases, the floor / slab, repairs complete as required and connection to upvc waste pipe.

149

-

-

... More
od225435/2024_2025 : Supplying, installation, testing & commissioning of Addressable 2 Wire monitor module, capable of monitoring NO contacts, Option to choose operation mode as supervision of 20Sec or activation immediate to connect NO/NC contacts such as pressure switch, flow switches, fire pump contacts etc. Addressing shall be with user friendly rotary decimal switches.

14

-

-

... More
13.37.1 : White washing with lime to give an even shade:New work (three or more coats)

1400.2

-

-

... More
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B

614

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

10

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

29

-

-

... More
od221409/2024_2025 : Supply installation testing and commissioning of vertical type metal Double Door 6 way TPN, distribution board with 40A 4P MCB as incomer, and 18 nos 6-20A SP MCB as outgoing Total 26 Slots. Power(PDB) ( Rate for 18 nos, 6-20A SP MCB is not considered in this item.)

21

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

72.98

-

-

... More
od217921/2024_2025 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

250

-

-

... More
od213772/2024_2025 : Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way-150 mm dia M.S. Pipe

1

-

-

... More
od217917/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes- Self-Contained battery 90 min power backup Surface mounted LED Down light- 18 Watt LED with 90 min power backup

34

-

-

... More
HVAC Works

-

-

-

... More
od245217/2024_2025 : VRV SYSTEM: - VRF Outdoor Machines: 20 HP (10 HP+10 HP) - For all rooms except isolation rooms<br>Supply, unpacking, shifting, rigging, installation, testing & commissioning of VRF outdoor machines for air conditioning system, based on variable refrigerant mass flow, comprising of one or more variable output compressors, condenser coil & fins provided with anti-corrosive treatment to withstand outdoor conditions at subject, necessary accessories for oil separation, moisture removal, flow control, interconnecting piping between two or more outdoor units, condenser air fan/s, electrical and microprocessor based panel, interconnecting cabling, all housed inside a weather-proof cabinet suitable for exposed installation on terrace or outdoor corrosive environment. Any top up of refrigerant and oil required, hot dip galvanized stand for outdoor units with SS fasteners and serrated rubber pads, comprehensive guarantee/warrantee for the defect liability period including spares, consumables, refrigerant, labour, taxes, transport and incidental expenses, for following equipment. The panel must be 100% compatible with BMS. The unit/s must also be provided with self-addressable control system for control of indoor & other outdoor machines. The capacity & power consumption curves, deration/correction factor curves/charts for indoor temperature and piping derations must be submitted with offer, along with duly filled up datasheet in the attached format. The units must be CFC/HCFC free refrigerant. The cost of outdoor shall include isolators. Any interconnecting joinery for outdoor units shall form a part of this item. The unit shall be compatible to outdoor temperature of up to 52°C without trip and 40°C without any deration.<br>The quoted rate shall be inclusive of non-corrosive metallic foundation/stand with proper vibration isolation measures in compliance to necessary calculations.

1

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

3459.86

-

-

... More
16.21.1 : Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3, with 25 mm X 25 mm Gl section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 16 br brAcoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3Acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3

9

-

-

... More
od208618/2024_2025 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm , swinging type mixer fitting , 32mm dia bottle trap including painting of fittings and brackets, cutting and making good the walls wherever required (Glossy Finished Low Flow Green Fixture 2.5 lpm): 510x1040 mm bowl depth 250 mm

3

-

-

... More
od208638/2024_2025 : Providing and fixing uPVC threaded end cap joint to uPVC pipe as required complete in all respects for 110mm dia pipe. (Clean out plug / COP)

42

-

-

... More
od208678/2024_2025 : Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 meter).

28

-

-

... More
od54906/2023_2024 : Providing and laying average 50mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate up to 20mm nominal size). Mixing with water proofing compound of approved manufacturer with specified ratio, maintain proper slope & finishing at outlet of pipe and making hallow 75mmX75mm (Paid in separate) at the junction of roof & parapet, curing complete in all respect as per satisfaction of the Engineer in Charge etc.

604.48

-

-

... More
od224185/2024_2025 : Refnet/Y Joints: Supply & fixing of necessary copper pipe joins (Refnet/Y joints) for distribution of refrigerant in all individual branches, valves as per the schematic drawing confirming to manufacturer specifications for entire job.

1

-

-

... More
od221413/2024_2025 : Supply installation testing and commissioning of Double Door 4 way SPN, distribution board with 25A DP MCB as incomer, and 4 nos 6-20ASP MCB as outgoing Total 6 Slots . Corridor Lighting SDB. ( Rate for 4 nos 6-20A SP MCB is not considered in this item.)

7

-

-

... More
od222262/2024_2025 : LT PANEL: UPSMDB -WALL MOUNTED (UTILITY ROOM - FIRST FLOOR)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>1 no. 63A 4P MCCB,25KA, Thermomagnetic controlled.<br>1 Set of 63/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>Bus Bar<br>4 Strip aluminium bus bar of 63A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 25 KA fault - 1 set<br>Outgoing<br>2 nos. 40A DP MCB,10KA, Thermomagnetic controlled.<br>3nos. 25A DP MCB,10KA, Thermomagnetic controlled.

1

-

-

... More
od225779/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supplying, installing, testing and commissioning of 24 U U Rack with standard accessories.

1

-

-

... More
od221621/2024_2025 : LT CABLES: ALUMINIUM CABLE: Supply of the following size cable, heavy duty armored XLPE insulated and sheathed, as per ISI mark, 1100 volts grade aluminum stranded conductor cable of size as below all as specified - 3.5 Core 300 Sq.mm.

65.5

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

120

-

-

... More
od200292/2024_2025 : Filling the expansion gap at parapet wall by providing polysulphide sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Up to 25mm depth and 25 mm width.

28.2

-

-

... More
od52303/2023_2024 : Providing and fixing wooden molded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. Complete. Kiln seasoned and chemically treated Hollock wood.<br>Extra for corner beading

1678.4

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design

50

-

-

... More
od202079/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying Vision panel of 5mm thick borosilicate Fire Rated clear glass of size 320mm (W) x 470mm (H), Self adhesive side roll (Ceramic Tape) as required of approved make. (Labour charge for fixing included in the Door Shutter)

22

-

-

... More
od42065/2023_2024 : Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. (for Fire alarm & Talkback Riser - Red)

2500

-

-

... More
19.7.1.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885

25

-

-

... More
od217916/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes - 35W LED Surface/Wall Mounted Light Fixture

324

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
od221746/2024_2025 : SITC of DEHNterra 20 kg bag back filled compound, - Material Carbon based backfill/earthing compound, Fulgurite formation test at direct lightning (10/350 μm), lightning long duration test at- 100C No fulgurites/Pass, Environmentally Friendly ROHS certified, Resistivity- <0.12 ΩM, Complying Standard- IEC 62561-7 , Testing Approvals Certified from- NABL accredited Laboratories.

8

-

-

... More
od225637/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supplying, installing, testing and commissioning of Cat 6 patch cord-7FB (Rack end) for Data & Voice As per Specification.

38

-

-

... More
50.6.6.2 : Hollow block masonry using pre cast solid blocks (factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for Super structure up to floor two level for 10 cm thick wall in: CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete

62.44

-

-

... More
od214141/2024_2025 : Supply and fixing of Standard Fireman's Axe with heavy insulated handle

7

-

-

... More
od199141/2024_2025 : Providing and fixing bright finished SS hanging type floor door stopper with necessary screws, etc. complete.

330

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

127

-

-

... More
od222273/2024_2025 : LED EXIT SIGNAGES: Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's (Size- 300mm(L) x180mm(H)) Made up of uniformly extruded, aluminum alloy and 8 M. M. clear acrylic sheet including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required. Note: Lettering size of Signage will be provided as per project requirement: TOILET SIGNAGE (Ladies)

4

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1587.2

-

-

... More
9.100.3 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm

517

-

-

... More
od198641/2024_2025 : Carriage of Material By Mechanical Transport including loading, unloading and stacking up to 1km beyond initial lead- Building Rubbish

2.8

-

-

... More
od42052/2023_2024 : Supplying, installation, testing & commissioning of fire fighter <br>telephone handset complete as required

3

-

-

... More
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe

22

-

-

... More
9.26 : Extra for cutting rebate in flush door shutters ( Total area of the shutter to be measured).

6.3

-

-

... More
17.73.1 : Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms

137

-

-

... More
od198137/2024_2025 : Pile Integrity Test: For provision of Integrity test by cross hole Sonic Logging method, providing & fixing 40mm dia PVC pipe including connector/fittings holding with Rebar of Pile in proper position as per Drawing for performing Sonic Logging integrity test of Pile. Junction of Joints should be leakage free by pasting with tape complete . Note :- This pipe should be filled with grouting after performing test with no extra cost.

6370.5

-

-

... More
9.23 : Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

602.7

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

2860

-

-

... More
od213767/2024_2025 : Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyester powder coated complete with brass forged ball valve, gun metal cap and nozzle, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases: Capacity 2kg

7

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

30

-

-

... More
od198690/2024_2025 : Providing & laying light weight concrete as per drawing of approved make, complete in all respect as per Engineer in charge. Density: 10KN/Cum<br>

21.44

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

163

-

-

... More
od221742/2024_2025 : Supply, Installation, testing & commissioning of following hot dip galvanized strips / (thickness of galvanization not less than 75 microns) / cables, for grounding system / lightning protection system, running on wall parapet / column, roof truss, tie beams / on cable trays cable trench, embedded in floor or buried in ground at min 500mm: 50x8mm GI Strip

100

-

-

... More
od202083/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying Door frame fastener of approved make. (Labour charge for fixing included in the Door Shutter)

162

-

-

... More
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

141

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

273

-

-

... More
od37714/2023_2024 : Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:<br>150x100 mm size P type<br>With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

14

-

-

... More
13.59 : Coal tarring two coats on new work using 0.16 litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively.

167.84

-

-

... More
od200161/2024_2025 : Supplying, laying and fixing of std. chicken wire mesh flexible galvanized steel wire with hexagonal gaps. Available in 1 inch (about 2.5 cm) diameter, wire gauges 19 gauge (about 1 mm wire) to 22 gauge (about 0.7 mm wire). in positions at junctions of concrete & masonry works all complete as per specification, drawing and instructions of the Engineer in charge.

500

-

-

... More
od199143/2024_2025 : Providing and fixing SS Aldrap of approved design with necessary nuts & screw etc. complete in all respect: 16mm dia boltx200 mm long

283

-

-

... More
od212618/2024_2025 : Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification - For 15 mm dia Pipe 6 mm thick

773

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

1.2

-

-

... More
od42066/2023_2024 : Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. (for PA - Yellow)

3000

-

-

... More
od214136/2024_2025 : Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange - 100 mm dia

2

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

130

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

2.8

-

-

... More
od224165/2024_2025 : VRF System - Refrigerant Piping - 6.40 mm dia with 13mm thick insulation:<br>Supply, installation, testing and commissioning of refrigerant Liquid and Suction piping using eddy current tested Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods.<br>Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant top up, oil top up and incidental expenses also forms a part of the scope covered under this item. Price shall be inclusive of simulation report for VRF system<br>The refrigerant piping and control cables shall run over the GI cable tray and exposed cable trays shall be covered with another inverted GI race ways.<br>If a major variation in copper pipe quantity is observed, a detailed breakup sheet to be submitted with the quotation by contractor.<br>Insulation material shall be closed cell elastomeric EPDM (Ethylene Propylene Diene Monomer) Rubber with factory laminated 7mil/180micron thick treated glass cloth, moisture diffuser resistance factor or 'µ' value should be minimum 11,000 without any external laminate as per ASTM E 96, thermal conductivity of elastomeric EPDM rubber shall not exceed 0.033 W/mK at mean temperature of 0 Deg C according to ASTM C-518, Density of material shall be 60+20% kg/m3, EPDM insulation shall be rated V0 as per UL 94. The insulation shall have fire performance such that it passes class 'A' as per ATM E84. Insulation material shall be non-corrosive as per DIN 1988. Insulation shall have smoke density and toxicity tested according to IMO FTPC part 2 and 5 and in compliance with IMO 2010 FTP code ch.8. Insulation material shall have inbuilt anti-microbial protection as UL-181 for Anti-fungal and ASTM-2180-1 for anti-bacterial. The material should comply to RoHS Directive 2002/95/EC amended up to 2011/65/EU.

63

-

-

... More
od54843/2023_2024 : Floor Joint-Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self-aligning / self-centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).<br>Floor Joint up to 150 mm gap

25.2

-

-

... More
od54716/2023_2024 : Extra for shuttering in circular work (20% of respective centering and shuttering items)<br>For Lintel, Beam

2510

-

-

... More
od198231/2024_2025 : Pile Integrity Test: Integrity testing of Pile using Cross Hole Sonic Logging method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.

69

-

-

... More
od133599/2024_2025 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note 1: Truck Mounted rotary/TMR/Tube well boring machine shall not be used. Note 2: Cement content considered in this item is @ 400 kg/cum and Rate is inclusive of minimum cement content @400kg/cum. No extra payment will be made if excess cement required more than 400kg/cum to achieve the design mix. 600 mm dia piles

6410.5

-

-

... More
18.14 : Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete ( cost of water meter and stop cock to be paid separately)

2

-

-

... More
od224155/2024_2025 : VRF System - Refrigerant Piping - 28.6 mm dia with 19mm thick insulation<br>Supply, installation, testing and commissioning of refrigerant Liquid and Suction piping using eddy current tested Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods.<br>Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant top up, oil top up and incidental expenses also forms a part of the scope covered under this item. Price shall be inclusive of simulation report for VRF system<br>The refrigerant piping and control cables shall run over the GI cable tray and exposed cable trays shall be covered with another inverted GI race ways.<br>If a major variation in copper pipe quantity is observed, a detailed breakup sheet to be submitted with the quotation by contractor.<br>Insulation material shall be closed cell elastomeric EPDM (Ethylene Propylene Diene Monomer) Rubber with factory laminated 7mil/180micron thick treated glass cloth, moisture diffuser resistance factor or 'µ' value should be minimum 11,000 without any external laminate as per ASTM E 96, thermal conductivity of elastomeric EPDM rubber shall not exceed 0.033 W/mK at mean temperature of 0 Deg C according to ASTM C-518, Density of material shall be 60+20% kg/m3, EPDM insulation shall be rated V0 as per UL 94. The insulation shall have fire performance such that it passes class 'A' as per ATM E84. Insulation material shall be non-corrosive as per DIN 1988. Insulation shall have smoke density and toxicity tested according to IMO FTPC part 2 and 5 and in compliance with IMO 2010 FTP code ch.8. Insulation material shall have inbuilt anti-microbial protection as UL-181 for Anti-fungal and ASTM-2180-1 for anti-bacterial. The material should comply to RoHS Directive 2002/95/EC amended up to 2011/65/EU.

5

-

-

... More
od202074/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying SS 304 Fire rated Ball Bearing But Hinges 100X 75X3MM, complete with SS Screws of approved make (Labour charge for fixing included in the Door Shutter)

88

-

-

... More
od222264/2024_2025 : LT PANEL: SMDB2FL-2, SMDB3FL-2, SMDB4FL-2, SMDB5FL-2 & SMDB6FL-2- FLOOR/WALL MOUNTED (ELECTRICAL ROOM)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>1 no. 63A 4P MCCB,25KA, Thermomagnetic controlled.<br>1Set of 63/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>Bus Bar<br>4 Strip aluminium bus bar of 63 A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 25 KA fault - 1 set<br>Outgoing<br>3 nos.25A 4P MCCB,25KA, Thermomagnetic controlled.<br>3Sets of 25/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>3 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

5

-

-

... More
od202073/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Providing and fixing of factory made Hollow metal 2 hrs. fire rated metal doors as per IS 3614 part-II & BS part-20 & 22 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI or BFRC for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory.<br> Frame-Metal Fire Door frame 2hrs FIRE RATED shall be double rebate profile of size 154 x 77 mm made out of 1.6mm minimum thick galvanized steel sheet of approved color. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening.<br>Fire rated Door Shutter-Metal Fire Door DOUBLE/SINGLE leaf 2hrs FIRE RATED of approved make shall be 49mm thick fully flush double skin door color appropriate ral no.(approved color) with vision fire retardent glass. Door leaf shall be manufactured from 1.2mm minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be ready for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per drawing & design with a beading and screws from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating of the door. <br>For Single Leaf Shutter with frame (including fixing of Hardware but supply paid in separate item)

12.6

-

-

... More
12.21.1 : Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement : 2 coarse sand: 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand) as per standard design:In 75x75 mm deep chase

179

-

-

... More
14.15.3 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)

20

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

2517.19

-

-

... More
od133783/2024_2025 : Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Rate is inclusive of cement content as required in the design mix.<br>All work above plinth level up to floor V level

1695

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

538

-

-

... More
od214132/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia

110

-

-

... More
od222266/2024_2025 : LT PANEL: MDB _FLOOR MOUNTED (ELECTRICAL ROOM GROUND FLOOR)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>2no. 630A 4P MCCB, 35 KA microprocessor controlled with overload, short circuit and earth fault protections.<br>1no. 400A 4P MCCB, 35 KA microprocessor controlled with overload, short circuit and earth fault protections.<br>2 Set of 630/5A CTs of 15VA burden, accuracy Class-0.5 for metering with digital multifunction meter.<br>1 Set of 400/5A CTs of 15VA burden, accuracy Class-0.5 for metering with digital multifunction meter.<br>3 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>3 No. Surge Suppressor Type-2 as per specification<br>BUS COULPER<br>2 no. 630A 4P MCCB, 35 KA microprocessor controlled with overload, short circuit and earth fault protections.<br>Electrical & Mechanical interlocking to be done between the incomer breakers and Bus couplers.<br>Bus Bar<br>4 Strip aluminium bus bar of 630 A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 35 KA fault - 1 set<br>Outgoing<br>2 nos. 250A 4P MCCB,35KA, Thermomagnetic controlled.<br>2 Set of 250/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>2 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>10 nos. 100A 4P MCCB, 35 KA, Thermomagnetic controlled.<br>10 Set of 100/5A CTs of 15VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>10 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>8 nos. 63A 4P MCCB,35KA, Thermomagnetic controlled.<br>8 Set of 63/5A CTs of 15VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>8 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

1

-

-

... More
od199139/2024_2025 : Providing and fixing Rim lock for double Leaf door flush door shutter including necessary necessary screw etc. complete in all respect

2

-

-

... More
18.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.

30

-

-

... More
19.7.2.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With Sewer bricks conforming to IS : 4885

1

-

-

... More
18.9.8 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work75 mm nominal inner dia pipes

296

-

-

... More
od245490/2024_2025 : UPS SYSTEM: Supply, Installation, testing & commissioning of microprocessor based UPS System, at 0.99 power factor True Online Double Conversion (VFI as per IEC 62040-3) UPS using PWM IGBT technology, 3 Phase input 400 V + 20% and input frequency 50 Hertz plus minus 10%, 3 phase output fixed setting at 380, 415 and 430 V, UPS operating in parallel redundancy mode and each comprising of the following. Micro processor / software controlled annunciation, protection (including against input phase reversal correction), and menu run diagnostic module, associated cabling, connections, terminations, erection etc. complete as required and as per specifications and comprising of the following:<br>(A)20KVA (3Ph/3Ph) High Performance IGBT/PWM based True-On-Line Double Conversion Microprocessor Controlled UPS system.<br>Input Voltage: 415 V, 3Ph, N <br>Output Voltage: 415V, 3Ph, N<br>(B)Output Power Factor = 1.0 (KVA= KW)<br>(C)Operating Ambient Temperature: 0 - 40 Deg C<br>(D)100% rated IGBT rectifier cum charger unit + 100% rated IGBT inverter, integrated in UPS module.<br>(E)Anti harmonic filter at rectifier input for achieving THD < 3% and input power factor of greater than 0.99 or IGBT rectifier.<br>(F)100% rated inbuilt galvanic isolation transformer of H-class delta/ Zig - Zag type at the inverter output (before Static Switch). If not available, then external @ output should be provided.<br>(G)100% rated inbuilt static switch at the inverter output.<br>(H)100% rated inbuilt static switch at the static bypass line.<br>(I)100% rated inbuilt Maintenance bypass.<br>(J)RS485/Modbus BMS connectivity with software.<br>(K)Inbuilt Phase Sequence Correction in UPS<br>(L)Built in AIR circulating fan.<br>(M)Fully compliant as per international performance & safety standards IEC 62040-1,2,3<br>(N)Battery: Sealed Maintenance Free Valve Regulated Lead Acid batteries for UPS system, for 30 minutes backup on full load<br>(O)Accessories: MS Rack to house batteries for the UPS system, Interlinks, DC Cable(10mtrs).<br>20KVA/20KW Stand Alone UPS System with 30 Minutes Battery Bank along with output galvanic isolation transformer & MODBUS

1

-

-

... More
od224188/2024_2025 : Condensate Drainpipe- 32mm dia with 9mm thick insulation: Supply, installation, testing and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 6 mm thick Nitrile insulation fire retardant grade as per the drawing and specifications.

10

-

-

... More
od199354/2024_2025 : Glazing for Window :With float glass panes of 6 mm thickness (weight not less than 14.96 kg/sqm)

354.68

-

-

... More
9.127.1 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.5 mm thick

1205.4

-

-

... More
od54845/2023_2024 : Providing anti slippery groove at steps on kota/ Granite

609

-

-

... More
od221791/2024_2025 : SITC of Lightning strike counter used to count the digital impulse currents. Device for installation preferably on down conductors of the lightning protection system or between equipotential bonding bar and earth-termination system. Operating current (8/20 µs)- 1 kA, Max. discharge current (10/350 µs)- 100 kA, Clamping range- Rd/Fl 8-10/30 mm, Number of occurrences up to 999, Operating temperature range (TU) -20 °C ... +60 °C. Lithium battery 3V, CR123A

1

-

-

... More
od202072/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Providing and fixing of factory made Hollow metal 2 hrs. fire rated metal doors as per IS 3614 part-II & BS part-20 & 22 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI or BFRC for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory.<br> Frame-Metal Fire Door frame 2hrs FIRE RATED shall be double rebate profile of size 154 x 77 mm made out of 1.6mm minimum thick galvanized steel sheet of approved color. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening.<br>Fire rated Door Shutter-Metal Fire Door DOUBLE/SINGLE leaf 2hrs FIRE RATED of approved make shall be 49mm thick fully flush double skin door color appropriate ral no.(approved color) with vision fire retardent glass. Door leaf shall be manufactured from 1.2mm minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be ready for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per drawing & design with a beading and screws from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating of the door.<br>For Double Leaf Shutter with frame (including fixing charge of Hardware but supply of Hardware paid in separate item)

25.2

-

-

... More
18.9.10 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work150 mm nominal inner dia pipes

139

-

-

... More
od68939/2023_2024 : Supply of Dash fastener as per required sizes for fixing of Door & Window aluminum Frame.

1514.13

-

-

... More
od208592/2024_2025 : Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, white P.V.C. flushing cistern with dual flush fitting of flushing capacity 6 liter/ 3 liter, including flush pipe, with manually controlled device (handle lever) conforming to IS , with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

-

-

... More
od198126/2024_2025 : Rock quality designation test: Boring 150mm dia holes using rotary drilling method in all kinds of soil/boulder/cobble for collection of disturbed/undisturbed samples and up to desired depth. (The work shall be include Mobilization of necessary equipment and shifting men and material wherever required.)

250

-

-

... More
26.23.1 : Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge.With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles

1095.4

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

2

-

-

... More
9.96.1 : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:300x16 mm

6

-

-

... More
od54768/2023_2024 : 25mm thick flooring with combination of Kota stone (80%) with white marble border & inlay (20%) as shown in drawings laid over 20 mm (average) thick base & jointed with grey/white cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete with base of cement mortar 1:4 (1 Cement: 4 coarse sand).

599

-

-

... More
od245218/2024_2025 : VRV SYSTEM: - VRF Outdoor Machines: 10 HP- For TFA<br>Supply, unpacking, shifting, rigging, installation, testing & commissioning of VRF outdoor machines for air conditioning system, based on variable refrigerant mass flow, comprising of one or more variable output compressors, condenser coil & fins provided with anti-corrosive treatment to withstand outdoor conditions at subject, necessary accessories for oil separation, moisture removal, flow control, interconnecting piping between two or more outdoor units, condenser air fan/s, electrical and microprocessor based panel, interconnecting cabling, all housed inside a weather-proof cabinet suitable for exposed installation on terrace or outdoor corrosive environment. Any top up of refrigerant and oil required, hot dip galvanized stand for outdoor units with SS fasteners and serrated rubber pads, comprehensive guarantee/warrantee for the defect liability period including spares, consumables, refrigerant, labour, taxes, transport and incidental expenses, for following equipment. The panel must be 100% compatible with BMS. The unit/s must also be provided with self-addressable control system for control of indoor & other outdoor machines. The capacity & power consumption curves, deration/correction factor curves/charts for indoor temperature and piping derations must be submitted with offer, along with duly filled up datasheet in the attached format. The units must be CFC/HCFC free refrigerant. The cost of outdoor shall include isolators. Any interconnecting joinery for outdoor units shall form a part of this item. The unit shall be compatible to outdoor temperature of up to 52°C without trip and 40°C without any deration.<br>The quoted rate shall be inclusive of non-corrosive metallic foundation/stand with proper vibration isolation measures in compliance to necessary calculations.

1

-

-

... More
od43546/2023_2024 : Providing and fixing in position mosquito proof coupling of approved municipal design<br>32mm dia

4

-

-

... More
od225897/2024_2025 : PASSANGER LIFT: Supply, Installation, Testing and Commissioning of Passanger Lift with 13 Person / 884kgs / 1.00 mps speed / Machine roomless (PM Gearless) / Travel- 22.8 Mtr. (approx)/Floors G + 6 / 07 Stops/ 07 Openings/ Shaft Size required: 2200mm W X 2000 mm D/ Car Size: 1600 mm W X 1350 mm D X 2200mm high/ Clear Door Opening: 900mm W X 2000mm H / Center Opening doors / VF Regenerativer based AC Variable, Variable Freq. / Stainless steel Finish / Handrail /Center Opening Power Operated sliding Car Door in SS Proof Finish / Centre Opening Power Operated Landing Door in SS Vandeal Proof Finish / Flooring / Automatic Rescue Device / Infra-Red Screen Sensor / Floor Annunciator with music / Over Load Warning Indicator / False Ceiling in Car / Digital Floor Position Indicators In Car & Landings – Orange Colour / Push Button – Orange L E D Illumination / Full Car Operating Panel – Press & Speak / Sill Angle / Sill Support / Fireman’s Switch At Ground Floor / Battery Operated Alarm Bell and Emergency Light / Pit Ladder / Minor Builders Works / Scaffolding / Lift License / Free Service One Year.

1

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

16

-

-

... More
19.2.4 : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all - round S.W. pipes including bed concrete as per standard design:250 mm diameter S.W. pipe.

215

-

-

... More
od224093/2024_2025 : VRF Hi Wall Split Unit- 1.28 TR / 459 CFM (Minimum Required CFM) : Supply, Installation, Testing and commissioning of Hi wall type VRF air conditioning units complete with fan, multirow cooling coil, drive motor, casing, drain pan, filters etc., with microprocessor control, mounting frames, Safety controls, cabling between indoor and outdoor units etc. Units are included with all Refrigeration Controls like thermostatic Expansion valve, Solenoid valve and insulated drain pan with drain piping to the nearest drain point as per specifications<br>Price shall be inclusive of:<br>-- Control cabling<br>-- Necessary support<br>-- Corded remote and its wiring<br> Sound level at 1m distance shall be less than 40 dBA. All other parameters as per the technical specifications given in the tender.

4

-

-

... More
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

8374.32

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

407

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

2

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
od217913/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes - 18W LED Surface Mounted Down Lighter Light Fixture

93

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

556.9

-

-

... More
od238688/2024_2025 : Hollow block masonry using pre cast solid blocks ( Factory made ) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for Super structure above five level for each floors or part thereof for 10cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand ) including cost of scaffolding etc. complete

23.89

-

-

... More
9.113 : Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge.

6

-

-

... More
od245112/2024_2025 : VRF Hi Wall Split Unit- 0.6 TR / 265 CFM (Minimum Required CFM): Supply, Installation, Testing and commissioning of Hi wall type VRF air conditioning units complete with fan, multirow cooling coil, drive motor, casing, drain pan, filters etc., with microprocessor control, mounting frames, Safety controls, cabling between indoor and outdoor units etc. Units are included with all Refrigeration Controls like thermostatic Expansion valve, Solenoid valve and insulated drain pan with drain piping to the nearest drain point as per specifications<br>Price shall be inclusive of:<br>-- Control cabling<br>-- Necessary support<br>-- Corded remote and its wiring<br> Sound level at 1m distance shall be less than 40 dBA. All other parameters as per the technical specifications given in the tender.

5

-

-

... More
Firefighting Works

-

-

-

... More
od214139/2024_2025 : Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle<br>conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)

7

-

-

... More
od224190/2024_2025 : Inline Fans: Supply installing testing and commissioning of Silent type inline fans suitable for installing in any position in vertical or horizontal ducts. Constructed with galvanized steel sheet, acoustic insulation within the outer shell. Suitable capacity of motor with removable fan body, class F insulation. All units shall be complete with duct flexible connector, volume control damper and static as specified.<br>Fan shall be with suitable IP protection in accordance with their installation as per equipment schedule: 3750 CFM,300 Pa

1

-

-

... More
od208620/2024_2025 : Providing and fixing Pillar Cock auto closing system with in control closing system with built in control clock With wall Flanges &Flow Restrictor 2.5 LPM AT 3 bar pressure quality conforming to IS standards and weighing not less than 810 gms.

151

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

14

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

87

-

-

... More
od212624/2024_2025 : Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification - For 80 mm dia Pipe13 mm thick

138

-

-

... More
od221623/2024_2025 : LT CABLES: ALUMINIUM CABLE: Supply of the following size cable, heavy duty armored XLPE insulated and sheathed, as per ISI mark, 1100 volts grade aluminum stranded conductor cable of size as below all as specified - 4 Core 25 Sq.mm.

461

-

-

... More
od202084/2024_2025 : FHC Door:--Supplying and fixing FHC Door with MS hollow section frame. Double Shutter fabricated from 16 Gauge GI Sheet final finish with Powder Coating with approved shade. Glass: 250 X 450 X 6 mm thick Clear Float Glass. Accessories like Hinges / Lock / Rubber Beading and Handle. Complete in all respect. Size Up to 1mX1.8m

14

-

-

... More
od152551/2024_2025 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.<br>After height of 13m to 16m

308.44

-

-

... More
19.19.1.1 : Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality.L D - 2.5Rectangular shape 600x450 mm internal dimensions

4

-

-

... More
od202078/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying Fire rated Panic Bar for Double Leaf Shutter Door approved make (Labour charge for fixing included in the Door Shutter)

16

-

-

... More
od222269/2024_2025 : LED EXIT SIGNAGES: Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's (Size- 300mm(L) x180mm(H)) Made up of uniformly extruded, aluminum alloy and 8 M. M. clear acrylic sheet including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required. Note: Lettering size of Signage will be provided as per project requirement: EXIT SIGNAGE (Left)

27

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

519

-

-

... More
od212835/2024_2025 : Domestic Hot Water Recirculation Pumps For Building :<br>Providing, installation, testing and commissioning of following insulated pumps suitable for 415 Volts connected with T.E.F.C. induction motor, M.S .channel, base plate complete with vibration isolators. The pump shall have mechanical seal. The pump shall be CI casing, Bronze impeller, Carbon Steel shaft and CI (Epoxy coated) base (suitable for hot water temperature) supply with pressure gauge, pressure switch and with gunmetal isolation  cocks,  vibration  elimination pads etc. complete with base and frame, nuts   and   bolts  and  to be fixed on RCC / PCC foundations as per requirement  as  per instructions  and  pump  shall  have following duty: (Include the cost of Control /Starter Panel Cabling and automation for the pumps) - Capacity/Flow Rate - 3000LPH - Head  -   30 m - 1 Set = 2 Nos. Pumps (1 working+1 standby)

1

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

5

-

-

... More
19.8.1.2 : Extra for depth for manholesSize 90x80 cmWith Sewer bricks conforming to IS : 4885

5

-

-

... More
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm

7

-

-

... More
od54844/2023_2024 : Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning /centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).<br>Wall Joint up to 150 mm gap

187.2

-

-

... More
od42047/2023_2024 : Supplying, installation, testing & commissioning of addressable manual call point complete as required

21

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

0.7

-

-

... More
9.40.2.1 : Kiln seasoned and chemically treated hollock wood50x12 mm

503.52

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

225.64

-

-

... More
od54842/2023_2024 : Providing & laying Cement concrete avg. 50mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) at floor at any Level

541.8

-

-

... More
od217911/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standard. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes - 14W Recessed LED Down Lighter Light Fixture

180

-

-

... More
16.12.2.4 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 1.25 mm thick

3

-

-

... More
od198899/2024_2025 : Providing & laying as per drawing Gungrade Polysulphide Sealent of approved manufacturer. Apply as per manufacturer specification & complete in all respect as per entire satisfaction of Engineer in-charge. 20mm width & 50 mm depth.

143.2

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

2

-

-

... More
od224191/2024_2025 : Propeller Fans: Supply, installation, testing and commissioning, of wall mounted type propeller exhaust fans complete with CRCA casing, polypropylene/ metallic blades impeller, powder coated automatic Aluminum louvered shutter with stove enamel paint, nut bolts, for use on 230/240 volts, single phase, 50 Hz, power supply with all accessories, ancillary work, etc. Fan RPM should not exceed 1500: - 200 DIA

6

-

-

... More
od200221/2024_2025 : Providing and fixing of 25mm thick pre molded Joint filler/ shalitex board or equivalent 350kg/cum for Expansion joint as per drawing and technical specifications

56.4

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

455

-

-

... More
12.38.1 : Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc:100 mm diameter

523

-

-

... More
50.6.1.8 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete

117.57

-

-

... More
21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness

18.9

-

-

... More
od199136/2024_2025 : Providing and fixing Door Handle Pair with Lock Set 1CK Satin finished Stainless Steel for flush door including necessary screw etc. complete in all respect

45

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

21

-

-

... More
od245432/2024_2025 : SITC of Roof Conductor of Diameter Ø- 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard IEC 62561-2:2018

295

-

-

... More
9.4.3 : Extra for additional labour for circular works, such as in frames of fan light:Kiln seasoned and chemically treated hollock wood

12.59

-

-

... More
9.25.1 : Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured)Decorative type door

44.52

-

-

... More
od208619/2024_2025 : Providing and fixing white vitreous wash down water close including wash basin (600 x 350mm) with one pair mounting brackets, C P pillar tap(Low Flow Green Fixture 2.5 lpm ) , EWC with dual flush fitting, of flushing capacity 6 liter/ 3 liter complete with fittings and seat cover, one no. hinged rail 760mm and five nos. of grab rail 600mm complete all respect.

6

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1965.68

-

-

... More
od50265/2023_2024 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No- 6 pin 5/6 & 15/16 A modular socket outlet and 1 No- 15/16 A modular switch, connections etc. as required.

195

-

-

... More
19.2.2 : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all - round S.W. pipes including bed concrete as per standard design:150 mm diameter S.W.pipe

22

-

-

... More
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

12.59

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

15

-

-

... More
12.38.2 : Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc:150 mm diameter

83

-

-

... More
8.8.1.2 : Fastener with threaded dia 10 mm

396.8

-

-

... More
od225777/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supply and Installation of 2U Panel Wiring Duct on Front (Cable Manager).

3

-

-

... More
od217910/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect . The product should conform to LM 79, 80 standard. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes- 18W Recessed LED Down Lighter Light Fixture.

173

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

4238

-

-

... More
od212621/2024_2025 : Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification - For 32 mm dia Pipe 9 mm thick

89

-

-

... More
od217912/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes - 11W LED Wall Mounted Mirror Light Fixture

158

-

-

... More
od213766/2024_2025 : Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge: Capacity 4.5kg. I.S.I. Marked.

7

-

-

... More
od245429/2024_2025 : SITC of Parallel Connectors for (700mm air terminal) connecting two conductors in parallel manner. Material- StSt, with clamping range- Rd / Rd 7-10 mm & Complied as per Standard IEC 62561-1:2023.

9

-

-

... More
9.7.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Float glass panes4 mm thick glass pane

33

-

-

... More
od198631/2024_2025 : Rock quality designation test: Rotary Drilling of NX size borehole (100mm - 150mm) in all type of hard rock up to 5m depth (including in continuation of boring in soil if applicable) using double tube core barrel (fresh rock) and collection of rock core samples from boreholes and preserving in boxes and determination of RQD, photographs where applicable. Rate includes collection of samples, perform Laboratory test on Rock sample and submission of Reports including field data. (The work shall be include Mobilization of necessary equipment and shifting men and material wherever required.)

5

-

-

... More
13.73.2 : Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and directions of the Engineer-in-Charge:20 mm wide and 15 mm deep groove

1200

-

-

... More
od217914/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes- 10W LED Wall Mounted BULKHEAD Light Fixture

21

-

-

... More
od152550/2024_2025 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.<br>After height of 10m to 13m

308.44

-

-

... More
od245431/2024_2025 : SITC of Universal connector of Material- StSt, with clamping range- 8-10mm, with truss head screw M10x35 mm & Complied as per Standard IEC 62561-1:2023.

30

-

-

... More
od221625/2024_2025 : LT CABLES: FIRE SURVIVAL CABLE: Supplying and making end termination with brass compression gland and copper lugs for following size of fire survival armored cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armoring & LSZH outer sheath complete as required. - 3Core16 Sq.mm

40

-

-

... More
od42062/2023_2024 : Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required

21

-

-

-

-

-

... More
od224092/2024_2025 : VRF Hi Wall Split Unit- 1.0 TR /388 CFM (Minimum Required CFM): Supply, Installation, Testing and commissioning of Hi wall type VRF air conditioning units complete with fan, multirow cooling coil, drive motor, casing, drain pan, filters etc., with microprocessor control, mounting frames, Safety controls, cabling between indoor and outdoor units etc. Units are included with all Refrigeration Controls like thermostatic Expansion valve, Solenoid valve and insulated drain pan with drain piping to the nearest drain point as per specifications<br> Price shall be inclusive of:<br>-- Control cabling<br>-- Necessary support<br>-- Corded remote and its wiring<br> Sound level at 1m distance shall be less than 40 dBA. All other parameters as per the technical specifications given in the tender.

2

-

-

... More
od198646/2024_2025 : Providing and applying Pro-shield HDPE- P system with HS Pro-shield -SBS-1.2 mm water proofing compound, the work shall be carried out as per below outline methodology as specified and as directed by engineer-in-charge. (1) Clean the side Vertical surface of the Pile Cap using a Mechanical Grinder. (2) Apply one coat of Solvent based bituminous Primer – over the side surface area of the Pile Cap @100gms/SQM. (3) Fix and stick 1.2mm thick Membrane on to the surface firmly with overlap of 5cms up to the top level of Pile Cap. (Minimum 50cms Height has to be fixed over the Pile Cap) (4) Keep an extension of 150mm of the Membrane so as to wield with the edge of 1.2mm HDPE pressure sensitive membrane. (5) After sand compacting & laying PCC, extend the SBS membrane edge towards the PCC surface. (6) On the surface which was consolidated by compacting sand, and laying PCC, loosely lay 1.2mm thick HDPE pressure sensitive membrane with 50mm overlap on which the reinforcement has to be arrayed and concrete has to be poured. (7) Keep an extension of 150mm of HDPE membrane from the shoe-edge / Termination of raft slab & retaining walls. (8) Fold this extended piece vertically and fix on the retaining wall surface using Concrete nails. (9) Apply one coat of PU Primer @125 gms/SQM on the retaining walls fully after proper surface preparation including Tie -rod hole filling , filling of Pores & cracks, Grinding etc. (10) Apply 2 coats of PU ELASTOSEAL 2K, PU COATING @ 730 GMS/SQ/COATS over the primed surface fully. The top level of PU coating should be 500mm above the ground level.

1989.92

-

-

... More
od221793/2024_2025 : SITC of Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- SS, Conductor leading- loose, Conductor holder support Rd- 8 mm With accessories Screw and Gitty, Material SS (M5 x 50mm)

415

-

-

... More
21.1.2.1 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

2316.95

-

-

... More
18.7.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15 mm nominal outer dia pipes

240

-

-

... More
20.9 : Integrity testing of pile using Low Strain / Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. Note:- The inclusion of the above item in the schedule of work shall be judiciously decided by the technical sanctioning authority, keeping in view the quality control, type of soil strata & importance of the project.

69

-

-

... More
9.99 : Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required clolour or shade, with necessary screws etc. complete.

6

-

-

... More
od42064/2023_2024 : Supplying, installation, testing & commissioning of 6 inches dia, <br>2 watts, 70/100 volts ceiling speaker complete as required. They shall be compatible with supplied Amplifiers and multi-tap should be available.

72

-

-

... More
od198932/2024_2025 : Providing & fixing SS Ties of shape & size as per drawing , properly fixing in position for crack prevention treatment work between RCC & Blockwork surface complete in all respect at any height as per direction of Engineer in charge.

1456

-

-

... More
18.16.1 : Providing and fixing brass stop cock of approved quality :15 mm nominal bore

250

-

-

... More
od208630/2024_2025 : Providing at site, lowering & laying in trenches, aligning & jointing of uPVC pipes of class III (6 kg/ cm2) as per IS:4985 and as per specification with rubber ring with socket and spigot joint,(EPDM/SBR) for all depths including well graded granular bedding (Type-E) for pipe length as per drawing and specification including hydraulic field testing and commissioning etc complete as directed by Engineer: 40mm diameter pipe

422

-

-

... More
od221744/2024_2025 : Supply, Installation, testing & commissioning of 50x8mm GI Bus Bars with 8 Termination holes

11

-

-

... More
21.11.5 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.710x19 mm

517

-

-

... More
1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

3

-

-

... More
od222271/2024_2025 : LED EXIT SIGNAGES: Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's (Size- 300mm(L) x180mm(H)) Made up of uniformly extruded, aluminum alloy and 8 M. M. clear acrylic sheet including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required. Note: Lettering size of Signage will be provided as per project requirement: EXIT / STAIRCASE SIGNAGE

14

-

-

... More
ELV Works

-

-

-

... More
od214143/2024_2025 : Providing & fixing of pressure switch in M.S. pipeline including connection etc. as required.

7

-

-

... More
od152552/2024_2025 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.<br>After height of 16m to 19m

308.44

-

-

... More
od311011/2023_2024 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>20 Gauge

3

-

-

... More
od238861/2024_2025 : Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor five level for each floors or part thereof with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

71.58

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

24

-

-

... More
od225458/2024_2025 : Supplying, installing, testing and commissioning of 6 Core Single Mode Optical Fiber cable Armored as per specification.

500

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
od243797/2024_2025 : CCTV SYSTEM: Supply, installation, testing and commissioning of 1/2.9 '' 2.1MP CMOS Starlight Sensor Dome Camera with effective 1945(H) X 1109(V) pixels, 2.8 mm fixed lens, Video Compression H.265, H.264,M-JPEG , Color 0.25Lux BW 0Lux with IR, IR Distance 60ft, 120dB WDR , Auto Iris , Dual Streaming , Frame rate 30 FPS on 1080p resolution ,Smart video stream Compression, Auto / Manual ( 1/15 ~ 1/32000 ), Audio In, Anti- Flicker, Slow Shutter( 2X, 3X, 5X, 6X, 7.5X, 10X ) 3D DNR , Motion detection , ONVIF S, Ethernet port 10/100 Mbps, 12DC, PoE, Metal body, IP66 and IK 10 protection, Certificate UL,BIS, CE , FCC & RoHS. 3 Years Standard Warranty. <br>Integration of camera with existing system along with necessary Sin Windows Server license for the CCTV server along with compatible Computer system as mentioned in specification.

35

-

-

... More
od208625/2024_2025 : Providing and fixing CP brass two way bib tap of approved quality conforming to IS standards

90

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

536

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

91

-

-

... More
od42050/2023_2024 : Supplying, installation, testing & commissioning of fire fighter phone jack complete as required

21

-

-

... More
od224311/2024_2025 : Supply installation testing and balancing of powder coated/anodized extruded Aluminum construction door transfer grille for makeup air.

1.58

-

-

... More
od225460/2024_2025 : NETWORKING SYSTEM (ACTIVE): Supplying, installing, testing and commissioning of SC Style Fiber Pigtails for Fiber backbone connectivity (complete with all accessories) as per manufacturers recommendation.

24

-

-

... More
od54717/2023_2024 : Extra for shuttering in circular work (20% of respective centering and shuttering items)<br>For edges of Slab

969

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

4238

-

-

... More
od202077/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying Fire rated Panic Bar for Single Leaf Shutter Door approved make (Labour charge for fixing included in the Door Shutter)

6

-

-

... More
od208634/2024_2025 : Providing and fixing S.S. round grating with round frame, 127 mm Dia overall size, glossy finish including setting in floor with cement mortar 1:3.

324

-

-

... More
od202081/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying Fire rated concealed flush bolt SS finish 300mm long of approved make (Labour charge for fixing included in the Door Shutter)

8

-

-

... More
13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats

7839.02

-

-

... More
21.4.2 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With brass cover plate minimum 1.25 mm thickness

12

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

258

-

-

... More
od217937/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes - Self-Contained battery 90 min power backup Recessed Mounted LED Downlight - 15 Watt

11

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

969

-

-

... More
od224094/2024_2025 : VRF Hi Wall Split Unit- 1.6 TR / 530 CFM (Minimum Required CFM) : Supply, Installation, Testing and commissioning of Hi wall type VRF air conditioning units complete with fan, multirow cooling coil, drive motor, casing, drain pan, filters etc., with microprocessor control, mounting frames, Safety controls, cabling between indoor and outdoor units etc. Units are included with all Refrigeration Controls like thermostatic Expansion valve, Solenoid valve and insulated drain pan with drain piping to the nearest drain point as per specifications<br>Price shall be inclusive of:<br>-- Control cabling<br>-- Necessary support<br>-- Corded remote and its wiring<br> Sound level at 1m distance shall be less than 40 dBA. All other parameters as per the technical specifications given in the tender.

7

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

220

-

-

... More
od224160/2024_2025 : VRF System - Refrigerant Piping - 22.2 mm dia with 19mm thick insulation:<br>Supply, installation, testing and commissioning of refrigerant Liquid and Suction piping using eddy current tested Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods.<br>Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant top up, oil top up and incidental expenses also forms a part of the scope covered under this item. Price shall be inclusive of simulation report for VRF system<br>The refrigerant piping and control cables shall run over the GI cable tray and exposed cable trays shall be covered with another inverted GI race ways.<br>If a major variation in copper pipe quantity is observed, a detailed breakup sheet to be submitted with the quotation by contractor.<br>Insulation material shall be closed cell elastomeric EPDM (Ethylene Propylene Diene Monomer) Rubber with factory laminated 7mil/180micron thick treated glass cloth, moisture diffuser resistance factor or 'µ' value should be minimum 11,000 without any external laminate as per ASTM E 96, thermal conductivity of elastomeric EPDM rubber shall not exceed 0.033 W/mK at mean temperature of 0 Deg C according to ASTM C-518, Density of material shall be 60+20% kg/m3, EPDM insulation shall be rated V0 as per UL 94. The insulation shall have fire performance such that it passes class 'A' as per ATM E84. Insulation material shall be non-corrosive as per DIN 1988. Insulation shall have smoke density and toxicity tested according to IMO FTPC part 2 and 5 and in compliance with IMO 2010 FTP code ch.8. Insulation material shall have inbuilt anti-microbial protection as UL-181 for Anti-fungal and ASTM-2180-1 for anti-bacterial. The material should comply to RoHS Directive 2002/95/EC amended up to 2011/65/EU.

50

-

-

... More
od212808/2024_2025 : SOLAR HOT WATER SYSTEM: Supply, Installation, Testing & Commissioning FPC Solar water heating system of capacity 3000 LPD (1500 LPD X 2Nos.) (including but not limited to the following items) - 1500LPD solar water heating system - Heat Exchanger Type, Hot Water Storage tank made out of SS 304 with TIG/MIG Welding having 4.0mm Shell Thickness and 4.0mm Dish Thickness with Aluminum Outer Cladding after 100mm Rockwool Insulation having density not less than 48Kg/Meter Cube. With In Built Heat Exchanger of SS304 and glycol as heat exchanger medium, 12Nos. Solar Flat Plate Collector of minimum 2030x1030mm size for minimum 2.0 Sq. Mtr. Absorber material Shall be ETP Grade Copper Fin and Tube. Copper sheet/absorber shall be electroplated with Nalson Black Chrome. The Collector shall be as per IS 12933. With Electrical Heater 8Nos. 6KW, Cold Water inlet, Hot Water outlet, Collector - Inlet and Outlet and Sacrificial Anode and suitable MS Stand black Painted after reoxide treatment. Including Loading the Solar Water Heater system on roof and grouting of the system with PCC as per site in charge & Required Accessories

1

-

-

... More
od224187/2024_2025 : Condensate Drainpipe- 25mm dia with 9mm thick insulation: Supply, installation, testing and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 6 mm thick Nitrile insulation fire retardant grade as per the drawing and specifications.

105

-

-

... More
od106302/2023_2024 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauge as required.<br>24 Gauge

120

-

-

... More
od224312/2024_2025 : Supply & fixing of powder coated extruded aluminum Louver as per specifications.

0.97

-

-

... More
od199145/2024_2025 : Providing and testing with smooth operation 6 lever pad Lock(Godrej NAV- TAL or equivalent), brass body , 3 keys with ring set & denomination of room no. in ring complete in all respect .

108

-

-

... More
od133809/2024_2025 : Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40 liter per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/ 25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified, Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers, prefabricated with center core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the topmost layer shall be finished with Providing & laying Cement concrete avg. 50mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) mixed with 2% integral water proofing compound by weight of cement.

604.48

-

-

... More
11.25 : Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.

294.05

-

-

... More
od208877/2024_2025 : Providing and fixing on wall face unplasticized Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - Single socketed pipes - 160 mm diameter

190

-

-

... More
od222270/2024_2025 : LED EXIT SIGNAGES: Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's (Size- 300mm(L) x180mm(H)) Made up of uniformly extruded, aluminum alloy and 8 M. M. clear acrylic sheet including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required. Note: Lettering size of Signage will be provided as per project requirement: EXIT SIGNAGE (Right)

27

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

2925

-

-

... More
od245475/2024_2025 : SITC of UNI Disconnecting Clamps with intermediate plate for round and flat conductor of Material- StSt, Material thickness- 2.5 mm, with clamping range- Rd / Fl 8-10 / 30 mm, & Complied as per Standard IEC 62561-1:2023.

14

-

-

... More
od214140/2024_2025 : Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

-

-

... More
17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.

2

-

-

... More
od214133/2024_2025 : Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

7

-

-

... More
9.22.1 : Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to I.S. 2202 ( part I)On one side only

12.6

-

-

... More
od222261/2024_2025 : LT PANEL: HVAC PANEL - FLOOR MOUNTED (ELECTRICAL ROOM GROUND FLOOR)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>1 no. 100A 4P MCCB,25KA, Thermomagnetic controlled.<br>1Set of 100/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>1 No. Surge Suppressor Type-2 as per specification<br>Bus Bar<br>4 Strip aluminium bus bar of 100 A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 25 KA fault - 1 set<br>Outgoing<br>2 nos.63A 4P MCCB,25KA, Thermomagnetic controlled.<br>2 Set of 63/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>2 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>6 nos.25A 4P MCCB,25KA, Thermomagnetic controlled.<br>6 Set of 25/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>6 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

1

-

-

... More
od224153/2024_2025 : Master/Central Remote Controller: Supply, Installation, Testing and Commissioning of Main Centralized Controller as per specifications for Controlling and Monitoring up-to 128 Indoor units. Controller shall have LCD Touch Screen of size less than 12 inch and more than 9 inch (diagonal screen size) or equal equivalent, Individual /Group Control, In-built BACnet TCP and Modbus IP Protocol for BMS Integration, capable to monitor, operate via PC/Tablet/Smart Phone, Web Access, Remote Access, Lock Function (Temperature, Mode, Fan), Set Temperature Range Limit, Yearly Schedule, Interlock, Emergency Stop and Operation Trend. In case of BMS system not in operation for any reason, the central controller shall be capable to work on standalone basis and should be able to indicate and control all indoor units as specified.

1

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

280

-

-

... More
od208631/2024_2025 : Providing at site, lowering & laying in trenches, aligning & jointing of uPVC pipes of class III (6 kg/ cm2) as per IS:4985 and as per specification with rubber ring with socket and spigot joint,(EPDM/SBR) for all depths including well graded granular bedding (Type-E) for pipe length as per drawing and specification including hydraulic field testing and commissioning etc complete as directed by Engineer: 50mm diameter pipe

4

-

-

... More
od224161/2024_2025 : VRF System - Refrigerant Piping - 19.1 mm dia with 13mm thick insulation:<br>Supply, installation, testing and commissioning of refrigerant Liquid and Suction piping using eddy current tested Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods.<br>Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant top up, oil top up and incidental expenses also forms a part of the scope covered under this item. Price shall be inclusive of simulation report for VRF system<br>The refrigerant piping and control cables shall run over the GI cable tray and exposed cable trays shall be covered with another inverted GI race ways.<br>If a major variation in copper pipe quantity is observed, a detailed breakup sheet to be submitted with the quotation by contractor.<br>Insulation material shall be closed cell elastomeric EPDM (Ethylene Propylene Diene Monomer) Rubber with factory laminated 7mil/180micron thick treated glass cloth, moisture diffuser resistance factor or 'µ' value should be minimum 11,000 without any external laminate as per ASTM E 96, thermal conductivity of elastomeric EPDM rubber shall not exceed 0.033 W/mK at mean temperature of 0 Deg C according to ASTM C-518, Density of material shall be 60+20% kg/m3, EPDM insulation shall be rated V0 as per UL 94. The insulation shall have fire performance such that it passes class 'A' as per ATM E84. Insulation material shall be non-corrosive as per DIN 1988. Insulation shall have smoke density and toxicity tested according to IMO FTPC part 2 and 5 and in compliance with IMO 2010 FTP code ch.8. Insulation material shall have inbuilt anti-microbial protection as UL-181 for Anti-fungal and ASTM-2180-1 for anti-bacterial. The material should comply to RoHS Directive 2002/95/EC amended up to 2011/65/EU.

21

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

5007

-

-

... More
od224189/2024_2025 : Condensate Drainpipe- 40mm dia with 9mm thick insulation: Supply, installation, testing and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 6 mm thick Nitrile insulation fire retardant grade as per the drawing and specifications.

2

-

-

... More
od224163/2024_2025 : VRF System - Refrigerant Piping - 12.7 mm dia with 13mm thick insulation:<br>Supply, installation, testing and commissioning of refrigerant Liquid and Suction piping using eddy current tested Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods.<br>Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant top up, oil top up and incidental expenses also forms a part of the scope covered under this item. Price shall be inclusive of simulation report for VRF system<br>The refrigerant piping and control cables shall run over the GI cable tray and exposed cable trays shall be covered with another inverted GI race ways.<br>If a major variation in copper pipe quantity is observed, a detailed breakup sheet to be submitted with the quotation by contractor.<br>Insulation material shall be closed cell elastomeric EPDM (Ethylene Propylene Diene Monomer) Rubber with factory laminated 7mil/180micron thick treated glass cloth, moisture diffuser resistance factor or 'µ' value should be minimum 11,000 without any external laminate as per ASTM E 96, thermal conductivity of elastomeric EPDM rubber shall not exceed 0.033 W/mK at mean temperature of 0 Deg C according to ASTM C-518, Density of material shall be 60+20% kg/m3, EPDM insulation shall be rated V0 as per UL 94. The insulation shall have fire performance such that it passes class 'A' as per ATM E84. Insulation material shall be non-corrosive as per DIN 1988. Insulation shall have smoke density and toxicity tested according to IMO FTPC part 2 and 5 and in compliance with IMO 2010 FTP code ch.8. Insulation material shall have inbuilt anti-microbial protection as UL-181 for Anti-fungal and ASTM-2180-1 for anti-bacterial. The material should comply to RoHS Directive 2002/95/EC amended up to 2011/65/EU.

70

-

-

... More
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work

10

-

-

... More
od208995/2024_2025 : Providing and fixing on wall face unplasticized - PVC molded fittings/accessories for unplasticized Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion- Shoe (Plain) - 160mm Shoe

3

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

30

-

-

... More
od221745/2024_2025 : Supply, Installation, testing & commissioning of 75x8mm GI Bus Bars with 8 Termination holes

1

-

-

... More
od224186/2024_2025 : Condensate Drainpipe- 20mm dia with 9mm thick insulation: Supply, installation, testing and commissioning of condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 6 mm thick Nitrile insulation fire retardant grade as per the drawing and specifications.

18

-

-

... More
od214137/2024_2025 : Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)

14

-

-

... More
od199144/2024_2025 : Providing and fixing 3'' Rubber /PVC buffer of required size and of approved quality with necessary screws etc. complete in all respect .

277

-

-

... More
od225649/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supplying, installing, testing and commissioning of Cat 6 Information outlet for data & Voice As per Specification.

34

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

838.04

-

-

... More
13.85.3 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre

7839.02

-

-

... More
2.27 : Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming consolidating and dressing complete.

293.68

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

-

-

... More
17.69.2 : Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms

3

-

-

... More
od214134/2024_2025 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia

7

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

254

-

-

... More
od222263/2024_2025 : LT PANEL: SMDB2FL-1, SMDB3FL-1, SMDB4FL-1, SMDB5FL-1 & SMDB6FL-1-FLOOR/WALL MOUNTED (ELECTRICAL ROOM)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>1 no. 100A 4P MCCB,25KA, Thermomagnetic controlled.<br>1Set of 100/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>Bus Bar<br>4 Strip aluminium bus bar of 100 A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 25 KA fault - 1 set<br>Outgoing<br>4 nos. 40A 4P MCCB,25KA, Thermomagnetic controlled.<br>4 Set of 40/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>4 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA

5

-

-

... More
od225636/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supplying, installing, testing and commissioning of Cat 6 patch cord-7FB (User end) for Data & Voice As per Specification.

38

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

2968

-

-

... More
19.6.3 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:250 mm dia R.C. C. pipe

215

-

-

... More
od212790/2024_2025 : Providing and fixing 2/2 Way Pilot Operated Diaphragm type Solenoid Valve, screwed or flanged end,suitable for water supply as per site, of SS body (SS-304) to ASTM A 351 GR CF 8 & internals having weather proof coil enclosure & working pressure range (min. 0.7 Kg/cm2 & max 12 Kg/cm2 ) with coil of 230 Volt, AC suitable for horizontal installation, normally closed with all electro mechanical accessories including 2/2 way Y type strainer at inlet of solenoid valve, screwed ends, body & cover SS 304 to ASTM A 351 GR CF 8 with same working pressure as stated above, having diaphragm of nitrile rubber and 40 mm mesh size. along with automatic solenoid valve On-Off Controller Box with one number Float switch sensor for water tank level controller with five meter long control wire connecting to solenoid valve and exluding electrical supply wire connection to controller box and wire from controller box to solenoid valve, with opeating voltage of 230 AC suitable for vertical/horizontal installation in water tank as per site condition suitably connected to solenoid valve through control cable all inclusive with all electro mechanical accessories complete operational - 40mm dia

2

-

-

... More
od199335/2024_2025 : Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process n the sequence as detailed below: (1). The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. (2). Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. (3). On drying of sealer coat, wet rubbing with emery cloth for finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. (4). On this, 1st coat melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-charge. (Final coat to be done in 1 or 2 layer without gap of time)

12.6

-

-

... More
od152555/2024_2025 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof- After height of 22m to 25m

128.7

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

65.5

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

12

-

-

... More
od221624/2024_2025 : LT CABLES: ALUMINIUM CABLE: Supply of the following size cable, heavy duty armored XLPE insulated and sheathed, as per ISI mark, 1100 volts grade aluminum stranded conductor cable of size as below all as specified - 4 Core 16 Sq. mm.

181

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

250

-

-

... More
19.27.1 : Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) including 500x450 mm pre- cast R.C.C. horizontal grating with frame complete as per standard design:With common burnt clay F.P.S(non modular) bricks of class designation 7.5

6

-

-

... More
od202075/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying SS 304 Fire rated Pull handle D Type 19mmx300mm Length of approved make (Labour charge for fixing included in the Door Shutter)

22

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

161

-

-

... More
4.17 : Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

130

-

-

... More
od311012/2023_2024 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>18 Gauge

3

-

-

... More
od311010/2023_2024 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>22 Gauge

3

-

-

... More
od224162/2024_2025 : VRF System - Refrigerant Piping - 15.9 mm dia with 13mm thick insulation:<br>Supply, installation, testing and commissioning of refrigerant Liquid and Suction piping using eddy current tested Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods.<br>Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant top up, oil top up and incidental expenses also forms a part of the scope covered under this item. Price shall be inclusive of simulation report for VRF system<br>The refrigerant piping and control cables shall run over the GI cable tray and exposed cable trays shall be covered with another inverted GI race ways.<br>If a major variation in copper pipe quantity is observed, a detailed breakup sheet to be submitted with the quotation by contractor.<br>Insulation material shall be closed cell elastomeric EPDM (Ethylene Propylene Diene Monomer) Rubber with factory laminated 7mil/180micron thick treated glass cloth, moisture diffuser resistance factor or 'µ' value should be minimum 11,000 without any external laminate as per ASTM E 96, thermal conductivity of elastomeric EPDM rubber shall not exceed 0.033 W/mK at mean temperature of 0 Deg C according to ASTM C-518, Density of material shall be 60+20% kg/m3, EPDM insulation shall be rated V0 as per UL 94. The insulation shall have fire performance such that it passes class 'A' as per ATM E84. Insulation material shall be non-corrosive as per DIN 1988. Insulation shall have smoke density and toxicity tested according to IMO FTPC part 2 and 5 and in compliance with IMO 2010 FTP code ch.8. Insulation material shall have inbuilt anti-microbial protection as UL-181 for Anti-fungal and ASTM-2180-1 for anti-bacterial. The material should comply to RoHS Directive 2002/95/EC amended up to 2011/65/EU.

57

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

28

-

-

... More
50.6.1.9 : Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

134.85

-

-

... More
14.15.1 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)

30

-

-

... More
od213770/2024_2025 : Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150 mm dia

2

-

-

... More
od208629/2024_2025 : Providing, fixing and testing UPVC soil waste and vent pipes UV stabilize and conforming to IS: 13592 - Type-B including all fittings conforming to IS:14735 such as W.C. connector, bends, junctions, inspection doors, offsets, vent cowls, as required/directed at site, jointing with rubber ring and rubber lubricant including cutting holes in walls and making good the same: 110 mm dia

2100

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

830

-

-

... More
od221414/2024_2025 : Supply installation testing and commissioning of 63A 4P MCB,10kA with steel sheet Metal enclosures.

1

-

-

... More
od208621/2024_2025 : Providing and fixing Health Faucet with 6mm dia., 1 m long PVC tube and wall hook all complete(Low Flow Green Fixture 6.0 lpm)

145

-

-

... More
od222265/2024_2025 : LT PANEL: MSRDB (MAIN SOLAR DISTRIBUTION BOARD)-FLOOR/WALL MOUNTED (ELECTRICAL ROOM)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>1 no. 100A 4P MCCB,25KA, Thermomagnetic controlled.<br>1Set of 100/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>Bus Bar<br>4 Strip aluminium bus bar of 100 A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 25 KA fault - 1 set<br>Outgoing<br>5 nos. 25A 4P MCCB,25KA, Thermomagnetic controlled.<br>5 Set of 25/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>5 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>9 nos. 25A DP MCB,10KA

1

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

12

-

-

... More
od245477/2024_2025 : SITC of Cross Units for Above ground and Underground Connections, without intermediate plate, for two flat conductors. Material of clamp- St/tZn, having clamping range Fl / Fl 30-40 / 30-40 mm & Complied as per Standard IEC 62561-1:2023

14

-

-

... More
od208637/2024_2025 : Providing and fixing clean out plug with suitable inset keys for opening in: brass / SS cap, male threaded joint with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects for 110mm dia Pipe.

46

-

-

... More
5.9.4 : Centering and shuttering including strutting, etc. and removal of form for:Shelves (Cast in situ)

280

-

-

... More
od228057/2024_2025 : Supply, fabricate & fixing 2nd class teak wood stair handrail (55mmX75mm) wherever required, shape as per drawing , French spirit polishing complete in all respect.

186.34

-

-

... More
od202080/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying Fire rated seal for grooved frame of approved make (Labour charge for fixing included in the Door Shutter)

76.8

-

-

... More
20.6.2.1 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test

3

-

-

... More
21.17 : Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).

865.15

-

-

... More
od208623/2024_2025 : Supplying, fitting and fixing full body SS Water Cooler with Purifier for drinking purpose of storage capacity not less than 80 liters, cooling capacity 40 liters/hour with 2 taps, ecofriendly refrigerant R134a or superior, with R.O., U.V, sediment and carbon filter, hermetic type compressor equipped with overload protection, thermostat control, condenser fan, power supply 230volts, 50 Hz, single phase power plug and electrical lead wire connection up to 3 meters from the water cooler, water inlet and drain out connections complete in all respects.

7

-

-

... More
od245430/2024_2025 : SITC of Connection Clamps for Steel/metal column. Clamping range of the clamp- 3-18 mm, Material of the clamp- StSt, Clamping range of conductor Rd 6-10 mm, & Complied as per Standard IEC 62561-1:2023.

4

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

2

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

46

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

36

-

-

... More
od221410/2024_2025 : Supply installation testing and commissioning of vertical type metal Double Door 6 way TPN, distribution board with 25A 4P MCB as incomer, and 18 nos 6-20A SP MCB as outgoing Total 26 Slots. Lighting (LDB) ( Rate for 18 nos, 6-20A SP MCB is not considered in this item.)

14

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

74

-

-

... More
od213768/2024_2025 : Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyester powder coated complete with brass forged ball valve, gun metal cap and nozzle, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases : Capacity 4kg

7

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

2600

-

-

... More
od225463/2024_2025 : NETWORKING SYSTEM (ACTIVE): Supplying, installing, testing and commissioning of Wireless Access point (as per specification) with Licenses to connect with existing Controller.

28

-

-

... More
13.50.1 : Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)

484.64

-

-

... More
od199140/2024_2025 : Providing and fixing SS 12'' tower bolts with necessary screws etc. complete :

218

-

-

... More
od54727/2023_2024 : Providing and fixing powder coated (50 micron) aluminium louvers (Sheet thickness minimum 1.8mm) including Powder coated aluminium frame of approved shade, size & specifications including necessary accessories. Complete in all respect as directed by Engineer in charge.

216.45

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

562

-

-

... More
5.3 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

8

-

-

... More
od208632/2024_2025 : Providing at site, lowering & laying in trenches, aligning & jointing of uPVC pipes of class III (6 kg/ cm2) as per IS:4985 and as per specification with rubber ring with socket and spigot joint,(EPDM/SBR) for all depths including well graded granular bedding (Type-E) for pipe length as per drawing and specification including hydraulic field testing and commissioning etc complete as directed by Engineer: 63mm diameter pipe

334

-

-

... More
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

355

-

-

... More
11.27 : Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

131.29

-

-

... More
od245418/2024_2025 : SITC of Parallel Connectors for (500mm air terminal) connecting two conductors in parallel manner. Material- StSt, with clamping range- Rd / Rd 7-10 mm & Complied as per Standard IEC 62561-1:2023.

11

-

-

... More
od52264/2023_2024 : Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:<br> 35 mm thick including ISI marked Stainless Steel ball bearing hinges with necessary screws

602.7

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

440.16

-

-

... More
od221411/2024_2025 : Supply installation testing and commissioning of vertical type metal Double Door 4 way TPN, distribution board with 25A 4P MCB as incomer, and 12 nos 6-20A SP MCB as outgoing Total 20 Slots. HVAC Power SDB. ( Rate for 12 nos, 6-20A SP MCB is not considered in this item.)

14

-

-

... More
od198124/2024_2025 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).<br>Extra over main item for Boring in Rock & removal of same. Complete in all respect as per Engineer in charge<br>Note 1: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.<br>Note 2: Cement content considered in this item is @ 400 kg/cum and rate is inclusive of minimum cement content of @ 400 kg/cum. No extra payment will be made if excess cement required more than 400 kg/cum to achieve the design mix. <br>600 mm dia piles

417

-

-

... More
od221743/2024_2025 : Supply, Installation, testing & commissioning of following hot dip galvanized strips / (thickness of galvanization not less than 75 microns) / cables, for grounding system / lightning protection system, running on wall parapet / column, roof truss, tie beams / on cable trays cable trench, embedded in floor or buried in ground at min 500mm: 75x8mm GI Strip

15

-

-

... More
od221748/2024_2025 : SITC of Poly plastic pit cover of material- Polymer Body & Cover, Product Code- HEP, Dimensions- 308 mm (L) x 308 mm (W) X 214 mm (H), Weight 2.5 kg (5.50 LBS).

8

-

-

... More
od198651/2024_2025 : Providing & fixing high density 125mm thick Thermacol Sheets at expansion joint as shuttering. Complete in all respect as per Engineer in charge.

218.01

-

-

... More
17.78 : Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.

145

-

-

... More
20.6.2.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test

3

-

-

... More
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick

228

-

-

... More
od212623/2024_2025 : Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification- For 50 mm dia Pipe13 mm thick

138

-

-

... More
od213771/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150 mm dia

1

-

-

... More
od52111/2023_2024 : Hard core soling of stone aggregate (60 mm to 45 mm) mixed with grannular material spread, levelled and well compacted in layers of 75 mm to required levels, slopes, camber etc. complete

103.65

-

-

... More
od52116/2023_2024 : Supplying & Filling with Good earth brought from out side in plinth/under floor including sorrounding of plinth in layers not exceeding 20cm in depth, consolidating and watering each deposited layer by compaction of earth work in filling under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). complete in all respect as approved by engineer-in-charge

360

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

481

-

-

... More
21.1.1.1 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

1277.67

-

-

... More
od54903/2023_2024 : Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster including providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. to the top surface of sunshade

99.37

-

-

... More
od221747/2024_2025 : SITC of StSt 316 grade clamp to terminate the load on earth electrode. Dimension- 160x35x3 mm.

8

-

-

... More
od225848/2024_2025 : CCTV SYSTEM: Supply, installation, testing and commissioning of 24 Port L2 Switch PoE Switch.

2

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

151

-

-

... More
od214135/2024_2025 : Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia

2

-

-

... More
od202076/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying SS 304 Fire rated Surface door closer, with standard arm, silver finish of approved make (Labour charge for fixing included in the Door Shutter)

22

-

-

... More
od245464/2024_2025 : SITC of Down Conductor of Diameter Ø- 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard IEC 62561-2:2018

415

-

-

... More
od225461/2024_2025 : Supplying, installing, testing and commissioning of Fiber Patch cord as per specification

6

-

-

... More
od217915/2024_2025 : Supply, installation, testing & commissioning of the following light fixtures complete with lamps, isolated led driver, Potted Driver for outdoor products etc. complete in all respect. The product should conform to LM 79, 80 standards. The product should have a constant current driver, built in heat sink. LED lamp should be certified with IS 10322. Supply including all accessories required for mounting at surface/ recess /wall as required conforming to relevant IS codes - 9W Recessed LED Down Lighter Light Fixture

84

-

-

... More
od217920/2024_2025 : Supply Occupancy movement detector with a built-in switch. It will switch off the lights in a room or area when it is vacated and thus save up to 30% of electrical energy. The occupancy switch can switch any load up to 6 A and control the common toilet area of around 20 sq. m. It is optimized for recessed ceiling mounting and for mounting heights between 2.5 and 3.5 meter. Compliance IEC 60669-2-1:2021.

20

-

-

... More
od55238/2023_2024 : Interior Paint on false ceiling: - Providing and applying 1 coat of Solvent based Cement Primer and 2 coats of Acrylic Emulsion of approved shade, complete as per manufacturers specifications, drawing & as directed by the Engineer-in-charge, complete as per manufacturers specifications, drawing & as directed by the Engineer-in-charge.

381

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

165.62

-

-

... More
1.14.10 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire

840

-

-

... More
16.12.2.3 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 1.00 mm thick

3

-

-

... More
od214138/2024_2025 : Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required: (A) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585. (B) 20 mm nominal internal dia gun metal globe valve & nozzle. (C) Drum and brackets for fixing the equipment's on wall. (D) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.- 30 m

7

-

-

... More
21.8.1 : Upto 5 mm depth and 5 mm width

928.84

-

-

... More
od221412/2024_2025 : Supply installation testing and commissioning of Double Door 4 way SPN, distribution board with 40A DP MCB as incomer, and 4 nos 6-25A SP MCB as outgoing Total 6 Slots . UPS DB. ( Rate for 4 nos 6-25A SP MCB is not considered in this item.

1

-

-

... More
8.2.1.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/Zebra black marbleArea of slab upto 0.50 sqm

67

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

2419

-

-

... More
od222358/2024_2025 : Off Grid Solar power on Roof Top: Supply, installation, testing and commissioning of 15kW Solar power with required accessories and 4hrs Battery backup.<br>Ref- Technical Specification

1

-

-

... More
od222272/2024_2025 : LED EXIT SIGNAGES: Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's (Size- 300mm(L) x180mm(H)) Made up of uniformly extruded, aluminum alloy and 8 M. M. clear acrylic sheet including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required. Note: Lettering size of Signage will be provided as per project requirement: TOILET SIGNAGE (Gents)

4

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

312164.76

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

10

-

-

... More
od199137/2024_2025 : Providing and fixing SS 240 mm D-type Door Handle Pair for flush door including necessary screw etc. complete in all respect

10

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

290.88

-

-

... More
12.63 : Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge.

350

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

208

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

1100

-

-

... More
od73829/2023_2024 : Supplying, installation, testing & commissioning of fault isolator complete with base as required

7

-

-

... More
od225775/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supplying, installing, testing and commissioning of 2-Port Faceplate with Labeling Windows As per Specification.

38

-

-

... More
od42051/2023_2024 : Supplying, installation, testing & commissioning of addressable phone control module complete as required

21

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

29

-

-

... More
od222260/2024_2025 : LT PANEL: PANEL (Water Heater) - FLOOR MOUNTED (AT ROOF NEAR STAIR)<br>Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized as per IEC-61439, design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. zero halogen fire retardant insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. (General arrangement and schematic Drawings to be approved by the Department before start of fabrication):<br>All ACB shall have Microprocessor based O/C, S/C & inbuilt E/F release <br>All ACBs should have Ics =Icu =Icw for 1 sec for the fault level specified in BOQ<br>All 4 Pole ACBs should have 100% neutral rating<br>All ACB & MCCB shall have Ics = 100% Icu<br>All MCCB up to 250A Shall be Thermomagnetic and MCCB Greater than 250 A shall have Microprocessor based release. All CTs and PTs shall be cast resin type.<br>All Breakers (ACBs) shall have LCD Display<br>All ACB'S shall have spare wired contacts for ON, OFF, Trip, rack-in, rack-out spring charge status for SCADA / BMS communication along with LCD display.<br>All MCCB outgoings spare wired contacts for ON/OFF and Trip shall be provided for SCADA / BMS communication.<br>Protection Relays MFM Shall have RS 485 Modbus / Profibus Communication protocol for SCADA / BMS communication.<br>Neutral CT for Neutral Overload protection and Earth Fault sensing should be provided for all 3 pole ACBs for 3 phase 4 wire system.<br>All MCCBs with Microprocessor release should have adjustable O/L, S/C & inbuilt E/F protections<br>MCCBs for motor back protection should be motor duty type and the ratings should be selected as per Type II coordination chart of manufacturer<br>MCCBs above 200A ratings should be provided with Copper Spreader Links & Phase barriers<br>MFM shall have following parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD.<br>Incoming<br>1 no. 250A 4P MCCB,25KA, Thermomagnetic controlled.<br>1 Set of 250/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>1 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>1 No. Surge Suppressor Type-2 as per specification<br>Bus Bar<br>4 Strip aluminium bus bar of 250 A, 415 V capacity with heat shrinkable colored sleeves complete for withstanding 25 KA fault - 1 set<br>Outgoing<br>3 nos. 125A 4P MCCB,25KA, Thermomagnetic controlled.<br>3Set of 125/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>3 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>9nos. 16A 4P MCCB,25KA.<br>9 Sets of 16/5A CTs of 15 VA burden, accuracy Class-1 for metering with digital multifunction meter.<br>9 Sets of R, Y, B phase indicating light (LED type) with 2A, SP MCB, 10KA<br>2 nos. 16A DP MCB,10KA

1

-

-

... More
od224095/2024_2025 : VRF Hi Wall Split Unit- 2.0 TR / 671 CFM (Minimum Required CFM) : Supply, Installation, Testing and commissioning of Hi wall type VRF air conditioning units complete with fan, multirow cooling coil, drive motor, casing, drain pan, filters etc., with microprocessor control, mounting frames, Safety controls, cabling between indoor and outdoor units etc. Units are included with all Refrigeration Controls like thermostatic Expansion valve, Solenoid valve and insulated drain pan with drain piping to the nearest drain point as per specifications<br>Price shall be inclusive of:<br>-- Control cabling<br>-- Necessary support<br>-- Corded remote and its wiring<br> Sound level at 1m distance shall be less than 40 dBA. All other parameters as per the technical specifications given in the tender.

1

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

77.39

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

6

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

2788.5

-

-

... More
od222268/2024_2025 : LED EXIT SIGNAGES: Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's (Size- 300mm(L) x180mm(H)) Made up of uniformly extruded, aluminum alloy and 8 M. M. clear acrylic sheet including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required. Note: Lettering size of Signage will be provided as per project requirement: EXIT SIGNAGE

17

-

-

... More
od245216/2024_2025 : VRV SYSTEM: - VRF Outdoor Machines: 6 HP - For Isolation Room - <br>(GENERAL NOTES FOR ALL THE HVAC WORKS:)<br>1.All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under “Basis of Design” in the specifications. Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the above-mentioned requirement.<br>2.The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of:<br>a.All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings.<br>b.Wastage on materials and labour<br>c.Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognized principles.<br>d.Liabilities, obligations and risks arising out of Conditions of Contract.<br>e.All requirements of Specifications, whether such requirements are mentioned in the item or not. The Specifications and Drawings where available, are to be read as complimentary to and part of the Schedule of Quantities and any work called for in one shall be taken as required for all.<br>f.In the event of conflict between Schedule of Quantities and other documents including the Specifications, the most stringent shall apply. The interpretation of the Engineer in charge shall be final and binding.<br>3.All Equipments, quantities and technical data indicated in this Schedule are for the Contractor’s guidance only, these are based on the documents prepared by the Services Consultant. This schedule must be read in conjunction with other documents. The Contractor shall be paid for the actual quantity of work executed by him in accordance with the approved Shop Drawings at the contract rates.<br>4.This Schedule shall be fully priced, and the extensions and totals duly checked. The rates for all items shall be filled in INK including NIL items.<br>5.No alteration whatsoever is to be made to the text or quantities of this Schedule unless such alteration is authorized in writing by Client / Consultant. Any such alterations, notes or additions shall, unless authorized in writing, be disregarded when tender documents are considered.<br>6.In the event of an error occurring in the amount of the Schedule, as a result of wrong extension of the unit rate and quantity, the unit rate quoted by the tenderer shall be regarded as firm and the extensions shall be amended on the basis of rates.<br>7.Any error in totaling in the amount column and in carrying forward total shall be corrected. Any error, in description or in quantity, omission of items from this Schedule shall not vitiate this Contract but shall be corrected and deemed to be variation required by the Services Consultant/Project Manager.<br>8.The Contractor shall procure and bring Materials/Equipment to the site only on the basis of drawings approved for construction and shop drawings and not on the basis of Schedule of Quantities which are approximate only. This also applies to the Contractor’s requisition for Owner supplied materials.<br>9.The unit rate for all local equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required.<br>10.Rates shall be inclusive of all sundries whether it is mentioned in BOQ/ specification or not. Rates to be quoted for complete SITC for the purpose stated in the basis of design.<br>11.Rates shall be inclusive of breaking and opening of wall, chasing of wall & floor for drain and making them good including finishing and painting up to client satisfaction. Cost of sealing of all air gaps opening with UL/FM approved fire sealant rate for 250C for 2 hours shall also be considered.<br>12.Responsibilities lies with contractor for maintaining /achieving the inside design conditions as stated in the DBR.<br>13.Contractor shall do three seasons testing for getting required condition in the rooms as per standard industry practices and all required commissioning data, as per client requirement and specification.)<br>VRF Outdoor Machines- 6 HP - For Isolation Room: Supply, unpacking, shifting, rigging, installation, testing & commissioning of VRF outdoor machines for air conditioning system, based on variable refrigerant mass flow, comprising of one or more variable output compressors, condenser coil & fins provided with anti-corrosive treatment to withstand outdoor conditions at subject, necessary accessories for oil separation, moisture removal, flow control, interconnecting piping between two or more outdoor units, condenser air fan/s, electrical and microprocessor based panel, interconnecting cabling, all housed inside a weather-proof cabinet suitable for exposed installation on terrace or outdoor corrosive environment. Any top up of refrigerant and oil required, hot dip galvanized stand for outdoor units with SS fasteners and serrated rubber pads, comprehensive guarantee/warrantee for the defect liability period including spares, consumables, refrigerant, labour, taxes, transport and incidental expenses, for following equipment. The panel must be 100% compatible with BMS. The unit/s must also be provided with self-addressable control system for control of indoor & other outdoor machines. The capacity & power consumption curves, deration/correction factor curves/charts for indoor temperature and piping derations must be submitted with offer, along with duly filled up datasheet in the attached format. The units must be CFC/HCFC free refrigerant. The cost of outdoor shall include isolators. Any interconnecting joinery for outdoor units shall form a part of this item. The unit shall be compatible to outdoor temperature of up to 52°C without trip and 40°C without any deration.<br>The quoted rate shall be inclusive of non-corrosive metallic foundation/stand with proper vibration isolation measures in compliance to necessary calculations.

1

-

-

... More
od225436/2024_2025 : Supplying, installation, testing & commissioning of Digital Audio Amplifier capable of processing One of 8 audio channels and total of 100 W at 70.7 VRMS output along with necessary enclosures. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) not be rail mounted / dependent on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation.

3

-

-

... More
od55268/2023_2024 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more

237555.15

-

-

... More
od133781/2024_2025 : Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Rate is inclusive of cement content as required in the design mix<br>All work up to plinth level

445.63

-

-

... More
11.13.1 : Providing and fixing glass strips in joints of terrazo / cement concrete floors40 mm wide and 4 mm thick

25

-

-

... More
od54793/2023_2024 : Providing and fixing Antiskid ceramic floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

587.2

-

-

... More
od106306/2023_2024 : Supplying and fixing of 19 mm thick duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class "O") insulation on duct after applying suitable low VOC adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self-adhesive nitrile rubber tape insulation ( From the Same OEM of insulation) complete as per specifications and as required.

63

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

621.06

-

-

... More
od212620/2024_2025 : Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification- For 25 mm dia Pipe 9 mm thick

332

-

-

... More
Electrical Works

-

-

-

... More
od225776/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supply and Installation of back box 86mm*86mm for face plate.

38

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

15000

-

-

... More
9.24.1 : Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square

30.15

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

32

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

7

-

-

... More
od225462/2024_2025 : NETWORKING SYSTEM (ACTIVE): Supplying, installing, testing and commissioning of 24port POE Switch, modular uplink as per specification.

3

-

-

... More
13.26 : Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

7946.66

-

-

... More
od224164/2024_2025 : VRF System - Refrigerant Piping - 9.50 mm dia with 13mm thick insulation:<br>Supply, installation, testing and commissioning of refrigerant Liquid and Suction piping using eddy current tested Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods.<br>Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant top up, oil top up and incidental expenses also forms a part of the scope covered under this item. Price shall be inclusive of simulation report for VRF system<br>The refrigerant piping and control cables shall run over the GI cable tray and exposed cable trays shall be covered with another inverted GI race ways.<br>If a major variation in copper pipe quantity is observed, a detailed breakup sheet to be submitted with the quotation by contractor.<br>Insulation material shall be closed cell elastomeric EPDM (Ethylene Propylene Diene Monomer) Rubber with factory laminated 7mil/180micron thick treated glass cloth, moisture diffuser resistance factor or 'µ' value should be minimum 11,000 without any external laminate as per ASTM E 96, thermal conductivity of elastomeric EPDM rubber shall not exceed 0.033 W/mK at mean temperature of 0 Deg C according to ASTM C-518, Density of material shall be 60+20% kg/m3, EPDM insulation shall be rated V0 as per UL 94. The insulation shall have fire performance such that it passes class 'A' as per ATM E84. Insulation material shall be non-corrosive as per DIN 1988. Insulation shall have smoke density and toxicity tested according to IMO FTPC part 2 and 5 and in compliance with IMO 2010 FTP code ch.8. Insulation material shall have inbuilt anti-microbial protection as UL-181 for Anti-fungal and ASTM-2180-1 for anti-bacterial. The material should comply to RoHS Directive 2002/95/EC amended up to 2011/65/EU.

123

-

-

... More
50.6.6.3 : Hollow block masonry using pre cast solid blocks ( Factory made ) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for Super structure above floor two level upto floor five level for 10cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand ) including cost of scaffolding etc complete

71.67

-

-

... More
Plumbing Works

-

-

-

... More
od222274/2024_2025 : LED EXIT SIGNAGES: Supply, installation, testing and commissioning of hanging type 1W LED based EXIT signage's (Size- 300mm(L) x180mm(H)) Made up of uniformly extruded, aluminum alloy and 8 M. M. clear acrylic sheet including with legend on both sides, nickel metal hydride battery having 3 hours duration complete as required. Note: Lettering size of Signage will be provided as per project requirement: TOILET SIGNAGE (Handicap)

6

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

4.95

-

-

... More
od212622/2024_2025 : Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification- For 40 mm dia Pipe 13 mm thick

27

-

-

... More
od198534/2024_2025 : Providing and laying minimum 0.15mm thick poly film sheet including proper Lap jointing, all complete as per instruction of Engineer in charge

691

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore

122

-

-

... More
18.15.1 : Providing and fixing brass bib cock of approved quality :15 mm nominal bore

61

-

-

... More
od225434/2024_2025 : Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable up to 10 Loops. Each loop shall have a capacity of minimum 159 detectors & 159 other devices excluding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. Products not having this feature must provide dedicated CPU for DVC. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programing without any dependency on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for programming the panel with all necessary licenses. Panel shall have Modbus/ BACnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable for remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th Edition. Panel shall have programmable switch plates for controlling horn strobe zones / AHU shut off etc. from panel itself. Panel shall have inbuilt auto dialer with minimum 6-line output. Panel shall have its own master firefighting telephone/audio control/command centre. Each loop of fire alarm panel shall have 15% spare addressable units - 1 Loop Main Fire Panel

1

-

-

... More
5.13 : Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span up to floor five level, including the cost of required centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

41

-

-

... More
od198537/2024_2025 : Carriage of Material By Mechanical Transport including loading, unloading and stacking up to 1km beyond initial lead - Earth

299.13

-

-

... More
od202082/2024_2025 : 2hrs.FIRE RATED METAL DOOR :- Supplying Mortise Dead Lock with both side key cylinder of approved make (Labour charge for fixing included in the Door Shutter)

14

-

-

... More
10.29.2 : Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides

209.48

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

401

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

137

-

-

... More
od225778/2024_2025 : NETWORKING SYSTEM (PASSIVE): Supplying, installing, testing and commissioning of 9 U Rack with standard accessories.

2

-

-

... More
11.31 : Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

609

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

1680

-

-

... More
od224090/2024_2025 : Supply, installation, testing and commissioning of factory built, cabinet type, Ceiling Suspended Treated Fresh Air Unit in double skin construction of the following capacity, complete with factory fabricated independent sections, housing the various components eg. forward curve fan, TEFC blower IE-3 efficiency motor suitable for operation on 415 ± 10% volts, 3 phase, 50 Hz AC, including 6 RD copper tube aluminium finned DX cooling coil, electronic expansion valve, controls and control cables, pre-filter sets, drain connections, support with anti-vibration mountings etc. as required and as per "schedule of equipment" and specifications. The DX cooling coil should be compatible with VRV/F ODU- TFA-GF-01

1

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.