Guruvayur Devaswom Tender
... More
The GD has issued a formal invitation for competitive bids for the Guruvayur Devaswom project, for Rewiring Of Guruvayur Devaswom Library At Vyjayanthi Building East Nada Of Guruvayur Temple in Thrissur, Kerala. The bid opening date for this tender is 09-05-2025 and the last date for bid submission is 19-05-2025. Interested bidders for Guruvayur Devaswom tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 15,500Document Cost
₹ 1,365Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_GD_763868_1Bid Award Id
ViewTender No
E3-7171/2024Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rewiring of Guruvayur Devaswom Library at Vyjayanthi building east nada of Guruvayur Temple
BOQ Items
... More
90.2.1.7
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
plug - Short point
2
-
-
... More
90.2.1.18
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control
ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - Long point.
21
-
-
... More
90.2.1.15
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control
light point with 6A, plate ceiling rose - Long Point
15
-
-
... More
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
50
-
-
... More
od180724/2024_2025
Supply and Installing wall mounted fan high speed 400mm sweep using suitable size nut bolt etc. as
required
2
-
-
... More
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
5
-
-
... More
1.34
Supplying and fixing brass batten/ angle holder including connection etc. as required.
1
-
-
... More
90.3.20.3
Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
2
-
-
... More
od169727/2024_2025
Supply and providing 200mm plastic shade in the exsisting batta holder as required.
1
-
-
... More
90.3.21.3
Supply & installation of light fittings on 'C/U' shaped flat iron bracket
Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
33
-
-
... More
od169728/2024_2025
Supply and providing 7/9W LED bulb in the exsisting battan/Bulkhead fitting as required.
1
-
-
... More
90.3.7
Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper
conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection
etc. as required.
32
-
-
... More
od170022/2024_2025
Supply installation testing and commissioning of LED Flood light fitting 125W with efficacy upto
150lm/w,Surge protection 20KV,IP66 5 years warranty LED Chip make Cree/Lumilled/Nichia Power
factor 0.9 and giving connection.LM 79&80 certificates to be produced.(LT Transformer G20/equivalent)
1
-
-
... More
od170023/2024_2025
Supply installation testing and commissioning of LED Flood light fitting 70W with efficacy upto
150lm/w,Surge protection 20KV,IP66 5 years warranty LED Chip make Cree/Lumilled/Nichia Power
factor 0.9 and giving connection.LM 79&80 certificates to be produced.(LT Transformer G20/equivalent)
5
-
-
... More
od181428/2024_2025
Supply installation testing and commissioning of LED High bay fitting 60W with efficacy upto
110lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9,surge protection 10 KV and giving connection..( Klite
Polar High Bay1 Id KL 3113/equivalent)
10
-
-
... More
od181421/2024_2025
Additional labour charges for fixing LED light fittings/other accessories above 5 metre height using
suitable scaffolding etc.as required
15
-
-
... More
od170024/2024_2025
Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standard
accessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V
grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm
sweep 5 star rated 26/28W at maximum speed BLDC ceiling fan with service value greater than or equal
to 6 complete with 260mm down rod , canopies, shackeles and blades working on 230V/240V single
phase A/C.
21
-
-
... More
od182445/2024_2025
Supply, installation , testing and commissioning of 200 mm light duty exhaust fan in plastic body with self
opening louvers working on 230V single phase A/C supply in the existing opening including making the
holes to suit the size of the above fan, fixing necessary bolt and nuts making good the damages etc. as
required including giving connections
1
-
-
... More
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
5
-
-
... More
1.47
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting
etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less
shall be ignored)
200
-
-
... More
90.4.8
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including
plastering colour washing etc. as required.
1
-
-
... More
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
250
-
-
... More
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
30
-
-
... More
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
50
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
40
-
-
... More
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
60
-
-
... More
1.17.6
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
50
-
-
... More
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
40
-
-
... More
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
30
-
-
... More
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
7
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
2
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
21
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2
-
-
... More
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required.
7
-
-
... More
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
2
-
-
... More
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.8 Module (125mmX125mm)
7
-
-
... More
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
3
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
12
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
30
-
-
... More
2.14.1
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
1
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
od184481/2024_2025
Installation of Cable tray using required accessories galvanized 8mm threaded support system with 2 nos
of anchor bolts with threaded rods each from ceiling with 2mm thick GI cross channels of maximum width
for 200 mm X 60mm size (OBO/Legrand/Hi Tech)
10
-
-
... More
od184482/2024_2025
Supply of Perforated strip galvanized Cable tray conforming to IEC-61537. The Tray shall be galvanized
for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max.
safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the
limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load. Size 200 mm
width x 60mm Height (OBO/Legrand/Indiana)
10
-
-
... More
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12
way, Double door
1
-
-
... More
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43)
2
-
-
... More
90.11.1.19
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB
with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
... More
90.14.10.3
Supply, conveyance and fixing the following types & current rated control gears & switchgears
conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as
required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting
range of 80 - 100% with thermal magnetic release having adjustable OL
1
-
-
... More
90.12.7.2
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with
factory made clamp
50
-
-
... More
90.12.7.39
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with
factory made clamp
10
-
-
... More
90.12.7.40
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with
factory made clamp
25
-
-
... More
90.12.7.41
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with
factory made clamp
50
-
-
... More
90.12.7.42
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with
factory made clamp
40
-
-
... More
9.1.1
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 6 sq. mm (19mm)
2
-
-
... More
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
4
-
-
... More
9.1.33
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 16 sq. mm (28mm)
2
-
-
... More
9.1.34
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 25 sq. mm (28mm)
2
-
-
... More
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
280
-
-
... More
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
270
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
80
-
-
... More
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
40
-
-
... More
od181417/2024_2025
Dismantling the exsisting light/fan/call bell point etc.with pipe wire,fittings,switches ,boxes and conveying
to section store.
50
-
-