Guruvayur Devaswom Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 17,650Document Cost
₹ 1,555Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_GD_754762_1Tender No
E7-6856/24Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rewiring of Poonthanam temple and Electrification of extended portion of auditorium at Poonthanam temple
BOQ Items
... More
90.2.1.6
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined
plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light
points
5
-
-
... More
90.2.1.7
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
plug - Short point
2
-
-
... More
90.3.19.3
Supply conveyance, installation, testing and commissioning the light fittings of following types made from
CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with
16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the
original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
10
-
-
... More
90.3.20.3
Supply & installation of light fittings on TW round blockbrSupply, conveyance installation testing and
commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all
accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the
fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire
conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type
fixture
60
-
-
... More
od152762/2024_2025
Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standard
accessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V
grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm
sweep 5 star rated BLDC ceiling fan with service value greater than or equal to 6 complete with 260mm
down rod , canopies, shackeles and blades working on 230V/240V single phase A/C.
37
-
-
... More
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
7
-
-
... More
90.4.2
Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm,
150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat
of red oxide primer as per IS 732 as required.
10
-
-
... More
90.4.8
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including
plastering colour washing etc. as required.
2
-
-
... More
od154904/2024_2025
Supply, installation , testing and commissioning of 300/305 mm light duty exhaust fan in metal body
working on 230V single phase A/C supply in the existing opening including making the holes to suit the
size of the above fan, fixing necessary bolt and nuts making good the damages etc. as required including
giving connections
2
-
-
... More
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
5
-
-
... More
od154942/2024_2025
Supply and providing 200mm plastic shade in the exsisting batta holder as required.
5
-
-
... More
od154943/2024_2025
Supply and providing 7/9W LED bulb in the exsisting battan/Bulkhead fitting as required.
5
-
-
... More
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
25
-
-
... More
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
20
-
-
... More
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
80
-
-
... More
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
20
-
-
... More
1.17.20
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
30
-
-
... More
1.17.29
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
10
-
-
... More
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
120
-
-
... More
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
10
-
-
... More
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
6
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
5
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
3
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
5
-
-
... More
90.10.3.15
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )32A DP switch with indicator
2
-
-
... More
1.27.1
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.1 or 2 Module (75mmX75mm)
4
-
-
... More
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
5
-
-
... More
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.8 Module (125mmX125mm)
1
-
-
... More
1.28.1
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.1 or 2 Module
4
-
-
... More
1.28.2
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.3 Module
5
-
-
... More
1.28.5
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.8 Module
1
-
-
... More
2.3.2
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8
way, Double door
2
-
-
... More
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12
way, Double door
1
-
-
... More
2.3.4
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16
way, Double door
1
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
20
-
-
... More
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
2
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
8
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
4
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
3
-
-
... More
90.12.5.1
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.2 core 4 sq mm
140
-
-
... More
90.12.5.3
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.2 core 10 sq mm
30
-
-
... More
90.12.7.1
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with
factory made clamp
30
-
-
... More
90.12.7.3
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with
factory made clamp
10
-
-
... More
9.1.2
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 10 sq. mm (19mm)
2
-
-
... More
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
40
-
-
... More
90.12.12.2
Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation50/38 mm or
nearest size
80
-
-
... More
od154132/2024_2025
Supply installation testing and commissioning of LED Flood light fitting 70W with efficacy upto
150lm/w,Surge protection 20KV,IP66 5 years warranty LED Chip make Cree/Lumilled/Nichia Power
factor 0.9 and giving connection.LM 79&80 certificates to be produced.(LT Transformer G20/equivalent)
10
-
-
... More
od154948/2024_2025
Supply installation testing commissioning of 6 Metre Octogaonal Pole made of hot dip galvanised GI
sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of
200x200x12mm suitable for wind speed as per IS 875 Part III round arm bracket suitable providing 6 nos
LED luminairs including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions
box etc.complete (Bajaj/Equivalent)br
2
-
-
... More
od155396/2024_2025
Supply and Installation of 80W LED high bay fitting with aluminium PDC,AL1070aluminium alloy
housing,efficasy 120lm/w,IP65,life 50000hours @ L70,THD10%,PF0.95,surge protection 5KV
including giving connection.(Osram Luxpower/equivalent)
4
-
-
... More
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
32
-
-
... More
14.1
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m
including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead
of 50 metres.
1
-
-
... More
14.7
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
1
-
-
... More
14.12
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
1
-
-
... More
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
1
-
-
... More
5.15
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
4.2
-
-
... More
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
220
-
-
... More
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
25
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
20
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
2
-
-
... More
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
20
-
-
... More
90.16.5.2
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.65 mm (12 SWG)
6
-
-
... More
od154147/2024_2025
Supply and installation of thermoplastic polycarbonate Energy Meter enclosures with hinged lid
300x315x214m- environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti
corrosive, degree of Ingress Protection IP 65 in accordance with IEC 60529 with transparent lid , suitable
to accomadate KSEB Meter,Cut outs etc.with mounting rail.(MI9210 of Hensel/equivalent)
1
-
-
... More
od154148/2024_2025
Supply and fixing 32A 415V 2 way neutral link mounted on DMC/SMC
1
-
-
... More
od154149/2024_2025
Supply and providing 20-63A HRC fuse link
1
-
-
... More
od154150/2024_2025
Supply and fixing 32A fuse holder suitable for providing cylindrical/Din fuse links using suitable Nut&bolt
etc. as required.
1
-
-
... More
5.22.3
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelCold twisted bars
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%