Guruvayur Devaswom Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 10,550Document Cost
₹ 930Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_GD_727861_1Tender No
E3-6805/24Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rewiring of GD Security barracks at the 2nd floor of Vyjayanti building East Nada Sreekrishna Temple Guruvayur
BOQ Items
... More
90.2.1.4
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
21
-
-
... More
90.2.1.6
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light
points
11
-
-
... More
90.2.1.7
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
plug - Short point
2
-
-
... More
90.3.20.3
Supply & installation of light fittings on TW round blockbrSupply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
12
-
-
... More
90.3.21.3
Supply & installation of light fittings on 'C/U' shaped flat iron bracketbrSupply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
32
-
-
... More
od145908/2024_2025
Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standard accessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep 5 star rated 26/28W at maximum speed BLDC ceiling fan with service value greater than or equal to 6 complete with 260mm down rod , canopies, shackeles and blades working on 230V/240V single phase A/C.
21
-
-
... More
od156823/2024_2025
Supply, installation , testing and commissioning of 300/305 mm heavy duty exhaust fan 900 rpm in metal body working on 230V single phase A/C supply in the existing opening including making the holes to suit the size of the above fan, fixing necessary bolt and nuts making good the damages etc. as required including giving connections
9
-
-
... More
od165508/2024_2025
Supply installation testing and commissioning of LED Flood light fitting 70W with efficacy upto
150lm/w,Surge protection 20KV,IP66 5 years warranty LED Chip make Cree/Lumilled/Nichia Power
factor 0.9 and giving connection.LM 79&80 certificates to be produced.(LT Transformer G20/equivalent)
1
-
-
... More
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required
10
-
-
... More
90.4.8
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including
plastering colour washing etc. as required.
9
-
-
... More
od165562/2024_2025
Supply and Installing wall mounted fan high speed 400mm sweep using suitable size nut bolt etc. as
required
1
-
-
... More
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm.
130
-
-
... More
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
30
-
-
... More
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding
connection etc as required..
1
-
-
... More
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
20
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
10
-
-
... More
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
30
-
-
... More
1.17.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
20
-
-
... More
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
20
-
-
... More
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
30
-
-
... More
1.17.15
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
10
-
-
... More
1.17.17
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.8 x 2.5 sq. mm
10
-
-
... More
1.17.19
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.10 x 2.5 sq. mm
10
-
-
... More
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
8
-
-
... More
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.8 Module (125mmX125mm)
6
-
-
... More
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
6
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
8
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
18
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
8
-
-
... More
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
6
-
-
... More
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
8
-
-
... More
od155973/2024_2025
Supply and providing 7/9W LED bulb on exsisting light fitting.
8
-
-
... More
od155974/2024_2025
Supply and providing 200mm plastic shade in the exsisting batta holder as required.
8
-
-
... More
od156796/2024_2025
Supply and fixing of GI Perforated Cable tray strip galvanised with horizontal & vertical bends, reducers, Tee's, cross over , suitable supports and bracketsbrand other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN ENbr10346 / ISO1461 .The trays should be tested for a max. safe working load of 185 Kgs with a span distance of 1.5 meters and the deflectionbrshould be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. 300 mm width x 60mm Heightbr
10
-
-
... More
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
1
-
-
... More
90.11.1.15
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
8
-
-
... More
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
4
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
15
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.15.3
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
... More
od158251/2024_2025
Supply & Clamping of DWC pipe on wall, column, piller, 50/38 mm or nearest size
2
-
-
... More
90.12.7.40
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with
factory made clamp
20
-
-
... More
90.12.7.41
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with
factory made clamp
40
-
-
... More
9.1.33
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 16 sq. mm (28mm)
2
-
-
... More
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
2
-
-
... More
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
2
-
-
... More
5.15
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
20
-
-
... More
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
75
-
-
... More
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
70
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
80
-
-
... More
90.16.1.4
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required4.00 mm copper conductor ( 8 SWG)
10
-
-
... More
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
20
-
-
... More
90.16.3.2
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using
clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of
clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal
run)25 x 3 mm GI strip
40
-
-