Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 32,500Document Cost
₹ 2,625Tender Fee
Refer Documents
Summary
Electrification Works At Changampuzhapark,edappally
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_GCDA_615759_1Bid Award Id
ViewTender No
E2/7107/2022/GCDATender Authority
Greater Cochin Development Authority ViewPurchaser Address
-Website
http://http://gcda.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
90.2.1.4 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modular ype front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
14
-
-
... More
90.2.1.6
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWG
bare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and
fixed along the periphery of the box using suitable ties, tie mounts etc as required.(RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug
socket controlled by 6 A, switch in the same switch board as that of light points
6
-
-
... More
90.2.1.7 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.(RoHS compliant modular accessories).Independent plug - Short point
6
-
-
... More
1.55.1 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
8
-
-
... More
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
190
-
-
... More
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
58
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm
80
-
-
... More
1.17.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X1.5 Sq. mm
32
-
-
... More
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm
84
-
-
... More
1.17.20
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x4 sq. mm
18
-
-
... More
1.17.31
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x6 sq. mm
12
-
-
... More
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6 amps switch
12
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.15/16 amp switch
4
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
12
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
4
-
-
... More
1.24.6
Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
2
-
-
... More
1.24.7
Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
2
-
-
... More
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
4
-
-
... More
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
4
-
-
... More
1.28.2
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
4
-
-
... More
1.28.5
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
4
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as
required.Single pol
18
-
-
... More
2.10.5
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as
required.Triple pole and neutral
6
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
... More
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.14.1
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2
-
-
... More
2.3.1
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
4
-
-
... More
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2
-
-
... More
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2
-
-
... More
90.11.1.16
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/TP MCB as outgoing (IP 42/43)
1
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
... More
2.23.1
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB
2
-
-
... More
5.1
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
2
-
-
... More
90.12.7.2
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
20
-
-
... More
90.12.7.3
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the
damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
10
-
-
... More
90.12.7.28
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
12
-
-
... More
90.12.7.40
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
18
-
-
... More
90.12.7.41
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the
damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
12
-
-
... More
90.12.7.43
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the
damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
12
-
-
... More
90.12.1.1
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm
320
-
-
... More
90.12.1.2
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
340
-
-
... More
90.12.1.3
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
20
-
-
... More
90.12.1.42
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but
excluding sand cushioning and protective covering (in ordinary soil).4 core 25 sq mm
98
-
-
... More
9.1.1
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
120
-
-
... More
9.1.2
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
4
-
-
... More
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2
-
-
... More
9.1.33
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2
-
-
... More
9.1.34
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
2
-
-
... More
9.1.35
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
2
-
-
... More
90.12.12.5
Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation90/75 mm or nearest size
34
-
-
... More
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
82
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
48
-
-
... More
90.16.1.10
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
620
-
-
... More
90.16.5.2
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
24
-
-
... More
OD222964/2022-2023
Supply, conveyance, installation, testing and commissioning of Hot dipped Galvanised ( internally and externally) seamless,Octagonal pole of overall height 6 Mts with single arm ..The top dia 70 mm, bottom dia 130mm having sheet thickness 3mm. The pole shall be with base plate of 225x225x16 mm and 4 nos required size of foundation bolt. The pole shall be mounted on suitable size foundation (design to be got approved) with 4A SP 'c' curve MCB,loop in loop out terminals block, required dia GI/ PVC pipe shall be provided in the foundation for taking cable in & out from the pole, 3 Core 1.5 sqmm unarmoured PVC insulated round copper cable from loop in loop out to light fixture etc with all required accessories. The cost of the civil foundation is not considered in this item.
4
-
-
... More
90.15.4.6
Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4
-
-
... More
90.4.5.4
Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
14
-
-
... More
OD218494/2022-2023
Supply, conveyance installation testing and commissioning of 230 V, 50 hz, 1800 Lumen, 0.8 pf, 15% THD, 2.5 KV Lighting surge protection type 18 w 1200 mm LED pre-wired light fittings complete with all accessories . directly on wall or ceiling and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire etc as required.
10
-
-
... More
OD 322399/2022-23 Supply ,conveyance,Installation ,testing and commissioning of 225mm sizeof exaust fansin the existing opening,fixing necessary boltand nuts ,making good the damages etc.as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheethed 3 core round copper conductor flex wire conforming to relevent ISS
2
-
-
... More
OD219297/2022-2023
40A, 230 V, DIN type fuse Link
6
-
-
... More
OD322411/2022-2023
100 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
1
-
-
... More
OD219298/2022-2023
63A, 415 V, DIN type fuse Link
3
-
-
... More
OD219299/2022-2023
Fabrication, supply & installation of dust and vermin proof, wall mounting, Sintex make meter box of 600x600x 214 mm size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
1
-
-
... More
OD219578/2022-2023
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
63 A TPN
1
-
-
... More
OD219300/2022-2023
Supply, Conveyance, installation, testing and commissioning of surface mounting 20 W LED Focus lamp fittings of all types directly on wall including giving connections
10
-
-
... More
OD219575/2022-2023
Supply and fixing of 30 watts ,240 volt LED bulb in existing decorative light fitting
12
-
-
... More
OD219576/2022-2023
Fabrication,supply and Installation of 3 meter height B class GI pole structure suitable for fixing ornamental outdoor fitting with necessary base plate, painting with metal primer and mat black finish enamel paint ,fixing the structure after necessary excavation( pit of 40cmx40 cmx60cm) with cement concrete (excluding the rate of CC)
12
-
-
... More
OD219577/2022-2023
Supply, installation, testing and commissioning of decorative type 30 watts garden light with all connected accessories fixed on the existing pole and giving connection. The LED garden Lighting luminaire shall be of IP65 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage of 30 with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3900 and system efficiency greater than or equal to 90%.The Light fitting shall be with all required
accessories suitable for mounting in on the pole . Weight of luminaire shall not be more than 7 Kg per fitting.The luminaire should meet all the technical specifications as mentioned .
12
-
-
... More
OD219672/2022-2023
Supply, Conveyance, installation, testing and commissioning of surface mounting 70 W LED down light fittings ( IP 65) of all types directly on roof slab/ on wall including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring etc as required ( stage)
10
-
-
... More
OD219770/2022-2023
Supply, installation, testing and commissioning of bollad garden light pole of 0.5 /0.6 meter height suitable for mounting one numbers 18 W LED guardan Light fixtures fixing on existing concrete bed and giving connection
60
-
-
... More
14.1
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres
1.5
-
-
... More
14.7
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required
4.7
-
-
... More
14.12
Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
1.2
-
-