Bharat Sanchar Nigam Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Bharat Sanchar Nigam Limited - BSNL Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date28 Jan 2025
Closing Date10 Feb 2025
Tender Amount₹ 5,42,340 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Arresting the Oil leak from the LT terminal bushing side of existing 160 KVA Transformer i/c complete dismantling the T/F terminal connections, opening the top cover to arrest the oil leaking via LT terminal bushings, tightening the terminals, providing new gaskets, refixing , the T/F top cover and all other accessories, pdg HT reconnections , replacing the defective LT side gaskets of transformer terminal box, checking and tightening the LT side cable connections in transformer terminal box etc complete as reqd.

1

-

-

... More
Recharging the breather using fresh silica gel after removing the hydrated gel ,cleaning the assembly, refilling with new gels, refixing etc as reqd.

1

-

-

... More
Spray painting the outside of the 160 kVA transformer i/c complete cleaning, removing dust, dirt, rust etc i/c pdg Two coats of enamel paint on accessible surface area i/c replacing the defective LT side gaskets of transformer terminal box, etc complete as required

1

-

-

... More
Servicing of following Electrical panels including cleaning the inside dust, checking and tightening all the connections such as busbar, cables etc, tightening switch terminals/ busbar taping etc I/c removing dust deposit using vacuum cleaner and pdg minor repairs of switches etc, replacement of fused indication lamps/defective indication lamp holders and control fuse , replacing the damaged gaskets/ rubber beedings ,i/c cleaning & removing the rust on surface of panel , providing one coat of superior quality spray enamel paint on accessible area of panel, sign writing etc complete as required.

-

-

-

... More
Main MV panel ( Approximate size 7.0mtr x2.0mtr x 1.0 mtr ) comprising switches 1000A ACB-3 Nos , 3 Nos SFUS with castel keys ( incomers ) , 16 Nos out going switches etc including dismantling / isolating the unwanted cable terminations from the not in use SFU out goings from MV panel etc ( excluding servicing of 1000Amps capacity ACBs )

1

-

-

... More
100 KVAR APFC panel with APFC Controller & capcitors, contactors, Including 1 No SDF incomer approximate size 0.90 mtr x 1.80 mtr x 0.60 mtr etc

1

-

-

... More
Light and Power Rising mains from ground floor to second floor wall made of sheet steel enclosure with PVC insulated 4 Nos aluminium bus bars suitable for 415 V, 3 phase, 4 wire, with extension joints , insulations and earthing with all accessories, TPN tap off boxes and SFUs etc associated with rising mains i/c opening the sheet steel covers, complete cleaning servicing the busbars and accessories, tightening all terminations , providing new fastners / minor spares if reqd, resetting the rising main / tap off boxes / SFUs, i/c painting the accessible area etc. as required

1

-

-

... More
Checking, correcting and testing of pick up time and closing time of IDMT relay 2 Nos of over current and 1 No of earth fault relay) by injecting 5 amps current using testing kit i/c checking and correcting connected control wiring in the LT/HT panel, Checking shunt trip circuit, auxiliary switch, trip healthy indication , trip push button etc as required. ( inverse type CDG, English electric make )

2

-

-

... More
Servicing of existing ACB in the LT panel i/c cleaning / checking all componets, mechanical parts, all moving and fixed contacts, auxilary contacts, all connections of CTs, control wiring, replacement of the minor components like springs , mechanical parts etc . i/c Lubricating all mechanical parts, cleaning contact tips, applying petroleum jelly on all contacts, refixing testing etc as required ( work should be carried out by a qualified and skilled technician)( English Electric make )

3

-

-

... More
Painting of 4-pole structure with connected MS channels, angle iron, connecting rods of AB switches cable protection pipe and other accessories etc, with two coat of superior quality epoxy paint after thoroughly cleaning the surface for removing dust, rust, cleaning the insulators, checking/ tightening the overhead connections/ lines on pole structure, lightning arrestors from metering end to transformer etc. complete as required.

1

-

-

... More
Complete painting of the angle iron welded mesh fencing around the pole structure i/c MS channel supports, MS weld wire mesh door etc with Two coats of epoxy paint after complete cleaning the surface for removing dust, rust etc as required

80

-

-

... More
Checking, meggering for earth resistance of the existing earth pits, cleaning the joints and reconnecting, replacing corroded nut and bolts, washers etc with new ones etc as required.

6

-

-

... More
Servicing of 11KV air break switch and the lever mechanism in the existing 11 KV pole structure for smooth operation of open close operations i/c cleaning , greasing the moving contacts, checking connections in the pole structure and switch, testing etc as reqd.

1

-

-

... More
Supply and replacing of following faulty items in the 11 kV pole structure i/c dismantling existing faulty accessories after checking, fixing new spares with suitable fastners, testing etc complete as required.

-

-

-

... More
DO Fuse metal parts ( Full set for 1 phase)

3

-

-

... More
11 KV Lightning Arrester

3

-

-

... More
11 KV Pin insulator

3

-

-

... More
11 KV AB switch metal parts ( moving & non moving spares for 1 phase)

3

-

-

... More
S/F new AB switch assembly to replace the the existing faulty 11 KV AB switch full set( moving & non moving items, insulators, base frame etc but with out operating rod ) for 3 phases i/c dismantlng the defective AB switch, fixing new gang operated switch, providing connections, fixing handle, testing commissioning etc as reqd.(metering side )

1

-

-

... More
Supply following accessories for 11KV substation etc as required.

-

-

-

... More
Supply of 6 mm nominal thick rubber mat suitable for MV supply as required.

2

-

-

... More
Rubber gloves of 11KV grade.

1

-

-

... More
Supply and fixing following items in the existing APFC Panel i/c replacing the faulty capacitor/contactor if reqd , making necessary connections /modifcations to fix the new capacitor/ contactor as pemananet capacitor if required, testing commissioning etc as required .

-

-

-

... More
Supply and fixing 3 KVAR capacity capacitor

1

-

-

... More
Supply and fixing 2 KVAR capacity capacitor

1

-

-

... More
Supply and fixing contactor MN 32 L&T or ss make

1

-

-

... More
Replacing the existing defective flourescent tube light fittings on surface of wall / ceilng in substation room with new 20W LED tube light fittings i/c dismantling the defective, Supplying and fixing of new lights with all accessories testing etc as required.

10

-

-

... More
Supply and fixing 450mm sweep 1400 RPM exhaust fans with suitable louvre on existing wall opening in substation room testing etc as required.

2

-

-

... More
Dismantling existing defective 18" dia exhaust fans with accessories from substation room etc as reqd.

2

-

-

... More
Dismantling / taking out of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV/ 11 KV grade of 120/ 150 Sqmm size on wall surface/ from existing trench/ open duct i/c storing suitably in the TE building etc as required.

30

-

-

... More
Dismantling the existing obsolete/ abandoned MS porcelain fuse cut out box with all accessories on wall i/c dismantling the existing incoming and out going terminations and cables with all accessories, safely storing etc as reqd.

1

-

-

... More
Supply and laying 5mm thick chequred MS sheet on existing floor openings of the old transformers in power room including cutting welding, fabricating painting etc for extending the cable connections etc complete as reqd

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.