Public Works Department Tender

... More
The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Providing Maintenance To 250kva Dg Sets With Fuel & Periodical Servicing Of A.m.f Panel Board , Lt Main And Sub Distribution Panel Boards And Connected Switch Gears Like Acbs, Mccbs Auto Change Over Switch, 500kva X 2 Now Of Tranformer Centers, Ht Yard, And Electrical Installations And Providing Labour Charges For Attending The Complaints And Operations Dg Sets Of Lh-1,2.3.4 & 5 Blocks At Legislators Home, Bengaluru. in Bengaluru Urban, Karnataka, with an estimated contract value of Rs. 78,80,603. The bid opening date for this tender is 28-05-2025 and the last date for bid submission is 06-06-2025. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Opening Date28 May 2025
Closing Date6 Jun 2025
Tender Amount₹ 78,80,603.18 
Notes
Download

Costs

Summary

Providing Maintenance To 250kva Dg Sets With Fuel & Periodical Servicing Of A.m.f Panel Board , Lt Main And Sub Distribution Panel Boards And Connected Switch Gears Like Acbs, Mccbs Auto Change Over Switch, 500kva X 2 Now Of Tranformer Centers, Ht Yard, And Electrical Installations And Providing Labour Charges For Attending The Complaints And Operations Dg Sets Of Lh-1,2.3.4 & 5 Blocks At Legislators Home, Bengaluru.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    PWD/2024-25/EL/WORK_INDENT13926
  • Tender No

    PWD/2024-25/EL/WORK_INDENT13926
  • Tender Authority

    Public Works Department View
  • Purchaser Address

    -
Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code84 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.9 32A DP Switch ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

30

358

10758

... More
code188 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.2023-24 - PWD-Electrical - Uni SR- Item code -6.12 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

5

3492

17462.5

... More
code76 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.5.6 10-12 Module ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

378

5676

... More
code170 - Supplying & fixing LED Drivers suitable for 5700K LED fitting Indoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 2023-24 - PWD-Electrical - Uni SR- Item code -12.51.3 9W to 12W 5700K suitable for indoor LED fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

30

462

13860

... More
code44 - Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.2023-24 - PWD-Electrical - Uni SR- Item code -1.1.2 25 mm dia 2 mm thick ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

120

89

10692

... More
code156 - Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. 2023-24 - PWD-Electrical - Uni SR- Item code -12.2.1 Ding Dong Bell ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

270

2706

... More
code63 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 2023-24 - PWD-Electrical - Uni SR- Item code - 2.5.9 4C x 2.5 mm2 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

90

162

14652

... More
code69 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.3.6 10-12 Way ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

287

5742

... More
code7 - Supply and fixing of radiator fan drive belts ISI approved for DG Set (AQR) SE ltr no:2008 dt:10.06.2014 SL No(1) d) 125 KVA to 250 KVA DG Set ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

2825

5650

... More
code26 - Charges fro servicing of Air Circuit breakers of following cleaning of ACB arcing cantacts, main contacotrs/arc cuts tesing of manual spring change motor, assembly testing of triping coils and lubrication of ACB as per requirement of following capacity at main Lt panel. Periodicaly maintenance for every six months. (AQR) SE ltr no:2008 dt:10.06.2014 SL No(13) c) 1250 amps 4 pole electrically operated draw out ACB ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

6

1800

10800

... More
code152 - Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 2023-24 - PWD-Electrical - Uni SR- Item code -11.14.1 1 x 2' Tube light fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

272

4092

... More
code153 - Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 2023-24 - PWD-Electrical - Uni SR- Item code -11.14.2 1 x 4' Tube light fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

50

397

19855

... More
code189 - Labour Charges for Electrical Helper (Un- skilled)with Tools and Electrical safety gadgets as required ( Basic Rate-613.88 +VDA Rs- 69.05 + ASL 10% + Contractor profit, 10%, Complete Per day Rs.819.52) 7 Persons x 312 Man Days = 2184 Man Days As Per Labour Department Notifica 0tion No.KaE/83/LAW/2022 Dt. 13.01.2023 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2184

819

1789831.68

... More
code54 - Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely2023-24 - PWD-Electrical - Uni SR- Item code - 1.9.3 32 mm ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

31

478.5

... More
code137 - Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.4.3 15-18W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

1838

18381

... More
code176 - Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.2023-24 - PWD-Electrical - Uni SR- Item code -6.8.3 2 Ton capacity ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

58845

117691.2

... More
code8 - Supplying and installation of electronic timer for start, stop, running time delay and start failure for DG Set. (AQR) SE ltr no:2008 dt:10.06.2014 SL No(16) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

3500

7000

... More
code103 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.15.10 FOUR Pole 125 A 25 kA ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

1

11375

11375.1

... More
code133 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code - 11.3.2 LED light fitting 1 x 4' - 20/22 W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

759

18975

... More
code167 - Supplying and fixing/replacement of pressure relief valve suitable for Geyser. 2023-24 - PWD-Electrical - Uni SR- Item code -12.14 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

50

682

34100

... More
code48 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.2023-24 - PWD-Electrical - Uni SR- Item code - 1.7.2 upto 50 mm conduit CC floor ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

75

1897.5

... More
code32 - Repair and servicing of flush mounting chairmen unit (Model No LBB3331/50 philips make)(AQR) SE ltr no:704 dt:11.05.2020 SL No(10) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

980

1960

... More
code33 - Repair and servicing of Ceiling ring type speaker (LBC Make) (AQR) SE ltr no:704 dt:11.05.2020 SL No(11) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

620

4960

... More
code122 - Supplying and fixing the fan motor for blowers and condenser of 1/5 HP, single shaft/double shaft suitable for split /window air conditioners. 2023-24 - PWD-Electrical - Uni SR- Item code -6.18 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

6727

13455.2

... More
code117 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. 2023-24 - PWD-Electrical - Uni SR- Item code -6.13.2 Cassette ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

1802

27043.5

... More
code149 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code - 11.11.4 9W, 6500K ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

80

169

13552

... More
code92 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 2023-24 - PWD-Electrical - Uni SR- Item code -3.14.6 6A Pendant Holder ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

78

781

... More
code59 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2023-24 - PWD-Electrical - Uni SR- Item code - 2.3.4 4 mm2 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

450

69

31185

... More
code 66 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.3.2 3 Way ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

136

1364

... More
code187 - Labour charges for Laying of XLPE UG Cable Using Conventional Laying with Excavation of Soil (Page:39, Sl.No.:11)b) Laying of cable in trench ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

0.7

49812

34868.68

... More
code16 - Charges for servicing with replacing of carbon brushes to self starter for existing DG Sets d) 125 KVA to 250.KVA DG Set. (AQR) SE ltr no:2008 dt:10.06.2014 SL No(8) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

6100

12200

... More
code14 - Supply and fixing of Diod kit for alternators.It includes the cost of all approved materials , lead lift and transportation etc. The work should be carried out as per the directions of engineer in charge of the work for DG Set (AQR) SE ltr no:2008 dt:10.06.2014 SL No(12) d) 125 KVA to 250.KVA DG Set. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

3700

7400

... More
code111 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 2023-24 - PWD-Electrical - Uni SR- Item code -6.1 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

1641

13129.6

... More
code151 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.11.6 15W, 6500K ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

60

358

21516

... More
code168 - Painting of existing street light pole after scrapping the old paint and painted with suitable colour enamel/Silver paint including coping/footing of the pole. 2023-24 - PWD-Electrical - Uni SR- Item code -12.17.1 upto 5 m street light pole. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

120

671

80520

... More
code11 - Supplying of 15/40 multi grade Engine lubricating oil (AQR) SE ltr no:705 dt:11.05.2020 SL No(8) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

80

145

11600

... More
code110 - Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. 2023-24 - PWD-Electrical - Uni SR- Item code -5.48 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

5327

10654.6

... More
code95 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 2023-24 - PWD-Electrical - Uni SR- Item code -3.14.14 32A Bakelite DP ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

255

5104

... More
code118 - Supplying installation testing and commissioning of heavy duty compressor suitable for window/split type A/C. 2023-24 - PWD-Electrical - Uni SR- Item code - 6.14.3 2 Ton ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

19825

39650.6

... More
code100 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.15.4 THREE Pole 200 A 25kA ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

15988

31977

... More
code163 - Releasing the existing fan and refixing the same in the new place with clamps without 'S' hook complete. 2023-24 - PWD-Electrical - Uni SR- Item code -12.10 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

88

880

... More
code127 - Supplying & filling refrigerant latest R-410 / R-32 for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. 2023-24 - PWD-Electrical - Uni SR- Item code -6.31 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

636

12738

... More
code72 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.5.2 3 Module ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

177

2656.5

... More
code60 - Supplying and drawing PVC insulated flexible copper wire of approved make as per IS: 694: 2010 2023-24 - PWD-Electrical - Uni SR- Item code - 2.4.1 14/0.0040" ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

350

23

8085

... More
code82 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.7 16A One Way Switch ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

198

4950

... More
code114 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 2023-24 - PWD-Electrical - Uni SR- Item code - 6.4.1 48" Sweep 5 Star (1200 mm) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

6

4733

28399.8

... More
code125 - Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts. 2023-24 - PWD-Electrical - Uni SR- Item code -6.26 (Unit M2) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

1310

32752.5

... More
code75 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.5.5 8 Module ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

312

6248

... More
code81 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.4 Stepped Fan Regulator Two Module ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

30

392

11781

... More
code34 - Servicing of 20 watts plena mixing amplifier.(Model No. LBC 19142) (AQR) SE ltr no:704 dt:11.05.2020 SL No(12) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

6350

12700

... More
code24 - Servicing of MCCB with control contacts operating mechanism and termination etc. main panel periodically maintenance for every six months of following of capacity (AQR) SE ltr no:2008 dt:10.06.2014 SL No(14) b) 400 amps 3 pole MCCB as per manufacturer standard ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

600

9000

... More
code189 - Supplying & fixing LED Drivers suitable for 5700K LED fitting Outdoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 2023-24-PWD-Electrica Uni SR-Item code 12.52.6. 150W 5700K suitable for outdoor LED fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

4635

46354

... More
code56 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2023-24 - PWD-Electrical - Uni SR- Item code - 2.3.1 1 mm2 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

720

20

15048

... More
code140 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 2023-24 - PWD-Electrical - Uni SR- Item code -11.8.4 LED Streetlight 90 W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

3

9746

29238

... More
code161 - Supplying and replacing ceiling fan regulator 900mm to 1500mm. 2023-24 - PWD-Electrical - Uni SR- Item code -12.6 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

420

8404

... More
code162 - Releasing the existing fan checking, testing and installation at the New place. 2023-24 - PWD-Electrical - Uni SR- Item code -12.9 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

79

1188

... More
code115 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 2023-24 - PWD-Electrical - Uni SR- Item code -6.5.1 300 mm Sweep ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

2741

21929.6

... More
code172 - Supplying & fixing LED Drivers suitable for 5700K LED fitting Indoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 2023-24 - PWD-Electrical - Uni SR- Item code - 12.51.5 25W 5700K suitable for indoor LED fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

738

14762

... More
code159 - Supplying and fixing/replacing condenser for ceiling fan/MV/ SV/MH and other luminaries. 2023-24 - PWD-Electrical - Uni SR- Item code -12.3.2 8mfd ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

179

1793

... More
code13 - Supply and fixing of lube oil pressure safety switch. It includes the cost of all approved materials , lead lift and transportation etc. The work should be carried out as per the directions of engineer in charge of the work for DG Set. (AQR) SE ltr no:2008 dt:10.06.2014 SL No(10) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

3500

7000

... More
code126 - Supplying and commisioning of AC Remote 2023-24 - PWD-Electrical - Uni SR- Item code -6.33 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

4

2256

9024.4

... More
code78 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.1 6A One Way Switch ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

180

112

20196

... More
code108 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.18.9 50-63 A TPN ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

5

3396

16984

... More
code29 - Servicing and amplifier of 250 watts capacity with necessary replacement of damaged transistor, capacitor, transformer, tuner switches, LED indicators, diode, toggle switch and IC. (AQR) SE ltr no:704 dt:11.05.2020 SL No(6) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

3500

28000

... More
code164 - Releasing the existing FTL Fitting all capacities, checking, testing and installing at same place. 2023-24 - PWD-Electrical - Uni SR- Item code -12.11 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

50

41

2090

... More
code46 - Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.2023-24 - PWD-Electrical - Uni SR- Item code - 1.3.2 25 mm dia 2 mm thick ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

90

86

7821

... More
code157 - Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. 2023-24 - PWD-Electrical - Uni SR- Item code -12.2.2 Musical ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

477

4774

... More
code132 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.3.1 LED light fitting 1 x 2' - 9/10 W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

606

12122

... More
code70 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.3.7 16 Way ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

323

2587.2

... More
code79 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.2 6A Two Way Switch ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

182

2739

... More
code36 - Servicing of Microphones with necessary magnetic coils, cartrige and control switch (ON/off) etc., and complete connection. (AQR) SE ltr no:704 dt:11.05.2020 SL No(4) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

4

950

3800

... More
code15 - Supply and fixing of Coolant water sensor. It includes the cost of all approved materials, lead lift and transportation etc. The work should be carried out as per the directions of engineer in charge of the work for DG Set. (AQR) SE ltr no:2008 dt:10.06.2014 SL No(11) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

3280

6560

... More
code77 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.5.7 16 Module ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

436

4367

... More
code136 - Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF0.95, power loss should5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.4.2 10-12W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

1395

11167.2

... More
code49 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.2023-24 - PWD-Electrical - Uni SR- Item code - 1.8.1 20 mm ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

35

30

1078

... More
code165 - Supplying and fixing/replacing of fluorescent tube. 2023-24 - PWD-Electrical - Uni SR- Item code -12.12.1 18 to 40W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

110

104

11495

... More
code62 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 2023-24 - PWD-Electrical - Uni SR- Item code - 2.5.2 3C x 1.5 mm2 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

180

79

14256

... More
code147 - Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.10.4 Polycarbonate/OPAL Acrylic Casing 8W-10W (T8) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

518

5181

... More
code55 - Supplying And Fixing "S" Hook made out of 14 mm dia M.S. Rod. 2023-24 - PWD-Electrical - Uni SR- Item code - 1.11 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

57

1430

... More
code160 - Rewinding a ... mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing. 2023-24 - PWD-Electrical - Uni SR- Item code -12.4.1 900mm ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

608

6083

... More
code57 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2023-24 - PWD-Electrical - Uni SR- Item code - 2.3.2 1.5 mm2 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

720

28

20592

... More
code68 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.3.5 8 Way ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

240

3613.5

... More
code64 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 2023-24 - PWD-Electrical - Uni SR- Item code - 2.6.1 3C x 2.5 mm2 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

150

128

19305

... More
code119 - Supply and fixing of condensing coil for Split Air Conditioners. 2023-24 - PWD-Electrical - Uni SR- Item code -6.15.3 2 Ton ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

1

12757

12757.8

... More
code138 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.6.2 LED modular down light 1'x1' 24W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

4061

40612

... More
code158 - Supplying and fixing/replacing condenser for ceiling fan/MV/ SV/MH and other luminaries. 2023-24 - PWD-Electrical - Uni SR- Item code -12.3.1 upto 4mfd ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

145

2178

... More
code83 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.8 6A Bell Push ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

194

2920.5

... More
code45 - Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.2023-24 - PWD-Electrical - Uni SR- Item code - 1.3.1 19/20 mm dia 2 mm thick ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

85

74

6358

... More
code93 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 2023-24 - PWD-Electrical - Uni SR- Item code -3.14.7 6A Batten Holder ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

81

2035

... More
code113 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 2023-24 - PWD-Electrical - Uni SR- Item code - 6.3.1 48" Sweep (1200 mm) Regular model ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

7

3282

22976.8

... More
code190 - Labour Charges for Lift Operator (LH Block 1 Lift No. 3.4 ) with Tools and safety gadgets as required. ( Basic Rate-613.88 +VDA Rs- 69.05 + ASL 10% + Contractor profit, 10%, Complete Per day Rs.819.52) (2Shifts) 4 Persons x 312 Man Days =1248 Man Days As Per Labour Department Notifica 0tion No.KaE/83/LAW/2022 Dt. 13.01.2023 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

1248

819

1022760.96

... More
code120 - Supplying and fixing capacitor's (of approved make) for window /split air conditioners. 2023-24 - PWD-Electrical - Uni SR- Item code - 6.16.1 25 to 45mfd running capacitor. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

3

885

2656.5

... More
code166 - Supplying and fixing/replacement of heating element for Geyser/Boiler. 2023-24 - PWD-Electrical - Uni SR- Item code -12.13.1 2kW Capacity ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

50

1153

57695

... More
code50 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.2023-24 - PWD-Electrical - Uni SR- Item code - 1.8.2 25 mm ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

40

38

1540

... More
code150 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.11.5 12W, 6500K ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

120

295

35508

... More
code109 - Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. 2023-24 - PWD-Electrical - Uni SR- Item code -5.47 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

3

2546

7639.5

... More
code97 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.7.2 32 A ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

265

2651

... More
code47 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.2023-24 - PWD-Electrical - Uni SR- Item code - 1.7.1 upto 50 mm conduit in brick wall ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

30

31

957

... More
code129 - 5 Star With Fibre body Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 2023-24 - PWD-Electrical - Uni SR- Item code - 7.2.2 35 L ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

6

17094

102564

... More
code139 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.6.3 LED modular down light 2'x2' 36 W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

5008

75124.5

... More
code107 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.18.4 6-32 A DP ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

812

8129

... More
code124 - Supply and fixing of out door condensing unit complete with condensing coil, blower, fan etc., complete suitable for Split Air Conditioners. 2023-24 - PWD-Electrical - Uni SR- Item code -6.23.3 2 Ton ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

1

34827

34827.1

... More
code175 - Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.2023-24 - PWD-Electrical - Uni SR- Item code -6.8.2 3 star 1.5 Ton capacity ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

3

49812

149437.2

... More
code30 - Repair to the 2.5 to 15 watts Horn with necessary magnetic coil, terminal with tuner switch and 100 Volts line matching tranformer. (AQR) SE ltr no:704 dt:11.05.2020 SL No(7) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

660

5280

... More
code121 - Supplying and fixing capacitor's (of approved make) for window /split air conditioners. 2023-24 - PWD-Electrical - Uni SR- Item code -6.16.2 80 to 200mfd starting capacitor. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

3

1042

3128.4

... More
code185 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM Page: 113)25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (Page - 9-27, SL.No.217) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

0.11

199597

21955.692

... More
code94 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 2023-24 - PWD-Electrical - Uni SR- Item code -3.14.13 16A Three Pin Top ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

121

1815

... More
code91 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 2023-24 - PWD-Electrical - Uni SR- Item code -3.14.5 6A Bakelite Ceiling Rose ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

85

2145

... More
code52 - Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely2023-24 - PWD-Electrical - Uni SR- Item code - 1.9.1 20 mm ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

35

20

731.5

... More
code142 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 2023-24 - PWD-Electrical - Uni SR- Item code -11.8.6 LED Streetlight 150 W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

4

16175

64702

... More
code86 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.11 TV/Telephone Socket ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

171

1716

... More
code145 - Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.10.1 Glass Casing 8W-10W (T8) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

258

5170

... More
code42 - Speaker Cables Supply, installation, testing and commissioning professional grade 2.5 Sq mm TIN coated low loss 2 core multi strand Oxidation Free speaker cable including, lead and lifts, loading and unloading, cost of conveyance for all the materials with the accessoreis. (AQR) SE ltr no:704 dt:11.05.2020 SL No(8) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

200

55

11000

... More
code10 - Supplying and applying of white petroleum jelly for DG Sets battery terminals (AQR) SE ltr no:2008 dt:10.06.2014 SL No(5) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

5

400

2000

... More
code65 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.3.1 1-2 Way ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

3

113

339.9

... More
code154 - Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 2023-24 - PWD-Electrical - Uni SR- Item code -11.14.3 2 x 4' Tube light fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

30

463

13893

... More
code173 - Supplying & fixing LED Drivers suitable for 5700K LED fitting Outdoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 2023-24 - PWD-Electrical - Uni SR- Item code -12.52.4 90W 5700K suitable for outdoor LED fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

9

2885

25967.7

... More
code58 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2023-24 - PWD-Electrical - Uni SR- Item code - 2.3.3 2.5 mm2 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

720

46

33264

... More
code61 - Supplying and drawing PVC insulated flexible copper wire of approved make as per IS: 694: 2010 2023-24 - PWD-Electrical - Uni SR- Item code - 2.4.2 23/0.0040" ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

250

24

6050

... More
code171 - Supplying & fixing LED Drivers suitable for 5700K LED fitting Indoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 2023-24 - PWD-Electrical - Uni SR- Item code -12.51.4 15W to 18W 5700K suitable for indoor LED fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

39

672

26211.9

... More
code80 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.3 6A Three Way Switch ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

50

188

9405

... More
code23 - Charges for servicing of auxiliary contactor, relay, timer testing of connections of all contactor relay timers and general checkups of control circuit of main change over panel. Periodically maintence for every six months. (AQR) SE ltr no:2008 dt:10.06.2014 SL No(15) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

2500

5000

... More
code4 - Charges for servicing of Diesel Engine for replacements of following items such as old oil removing from crank case, cleaning of crank case, changing of lube oil filters, changing of lube oil bypass filters, fuel filters, including tuning up engine and general "B" checkups, complete as per manufactures standards (AQR) SE ltr no:2008 dt:10.06.2014 SL No(6) d) 125 KVA to 250 KVA DG Set ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

24800

49600

... More
code1 - Supplying, installation, testing & commissioning of 12Volts .AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. a)1X 250 /500 KVA DG Sets (150 AH capacity) ( 9.4.6 ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

31005

62011.4

... More
code98 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.7.3 63 A ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

441

6616.5

... More
code123 - Supplying & filling refrigerant (F-22/F/12) for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. 2023-24 - PWD-Electrical - Uni SR- Item code -6.19 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

665

16637.5

... More
code104 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.15.15 FOUR Pole 250 A 36 kA ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

1

25899

25899.5

... More
code155 - Supplying and fixing one of 230 V bell or buzzer and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws. 2023-24 - PWD-Electrical - Uni SR- Item code -12.1 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

207

1663.2

... More
code99 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.15.1 THREE Pole 100 A 25 kA ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

6694

13389.2

... More
code5 - Charges for calibration and Fine Tuning of fuel injectors of d) 125 KVA to 250 KVA DG Set (AQR) SE ltr no:2008 dt:10.06.2014 SL No(2)d ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

10950

21900

... More
code28 - Charges fro servicing of Air Circuit breakers of following cleaning of ACB arcing cantacts, main contacotrs/arc cuts tesing of manual spring change motor, assembly testing of triping coils and lubrication of ACB as per requirement of following capacity at main Lt panel. Periodicaly maintenance for every six months (AQR) SE ltr no:2008 dt:10.06.2014 SL No(13) e) 800 amps 4 pole electrically operated draw out ACB ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

1350

10800

... More
code131 - Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 2023-24 - PWD-Electrical - Uni SR- Item code - 9.5.3 26 AH capacity ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

3972

39721

... More
code146 - Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.10.2 Glass Casing 18W-20W (T8) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

110

363

39930

... More
code101 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.15.5 THREE Pole 250 A 25 kA ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

18670

37340.6

... More
code53 - Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely2023-24 - PWD-Electrical - Uni SR- Item code - 1.9.2 25mm ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

24

605

... More
code148 - Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 2023-24 - PWD-Electrical - Uni SR- Item code -11.10.5 Polycarbonate/OPAL Acrylic Casing 18W-20W (T8) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

180

751

135234

... More
code112 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 2023-24 - PWD-Electrical - Uni SR- Item code -6.2.1 12" Sweep (300 mm) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

3265

26127.2

... More
code191 - Labour Charges for Supervisor for supervision of Electrical installations with 5year experience as required.( Basic Rate-679.48+VDA Rs- 69.05 + ASL 10% + Contractor profit, 10%, Complete Per day Rs.898.24) Per day 1Persons x 312 Man Days As Per Labour Department Notifica 0tion No.KaE/83/LAW/2022 Dt. 13.01.2023 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

312

898

280250.88

... More
code51 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.2023-24 - PWD-Electrical - Uni SR- Item code - 1.8.3 30 mm ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

47

1182.5

... More
code18 - Supplying and filling of distilled water for existing DG Set batteries (AQR) SE ltr no:2008 dt:10.06.2014 SL No(4) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

30

750

... More
code102 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.15.9 FOUR Pole 100 A 25 kA ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

1

9335

9335.7

... More
code169 - Painting of existing street light pole after scrapping the old paint and painted with suitable colour enamel/Silver paint including coping/footing of the pole. 2023-24 - PWD-Electrical - Uni SR- Item code -12.17.2 Above 5.5 to 7.5 m street light pole. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

838

20955

... More
code143 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 2023-24 - PWD-Electrical - Uni SR- Item code -11.9.3 LED Floodlight 120W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

11832

23665.4

... More
code174 - Supplying & fixing LED Drivers suitable for 5700K LED fitting Outdoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 2023-24 - PWD-Electrical - Uni SR- Item code -120W 5700K suitable for outdoor LED fitting. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

9

3751

33759

... More
code186 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 as per BESCOM specification. (BESCOM Page: 113)50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) (Page - 9-27, SL.No.221) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

0.1

266652

26665.21

... More
code43 - Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 2023-24 - PWD-Electrical - Uni SR- Item code - 1.1.1 19/20 mm dia 2 mm thick ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

150

75

11385

... More
code105 - Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 2023-24 - PWD-Electrical - Uni SR- Item code -5.17.1 4 Way ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

3

11361

34085.7

... More
code35 - Servicing of Dual deck cassette player.(Model No. RSTR-272 (AQR) SE ltr no:704 dt:11.05.2020 SL No(13) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

2250

4500

... More
code85 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.6.10 6/16A Universal Socket ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

30

259

7788

... More
code74 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.5.4 6 Module ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

257

2059.2

... More
code3 - Charges for calibration and Fine Tuning of fuel Pumps of d) 125 KVA to 250 KVA DG Set (AQR) SE ltr no:2008 dt:10.06.2014 SL No(3)d ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

9700

19400

... More
code90 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 2023-24 - PWD-Electrical - Uni SR- Item code -3.14.4 6A Three Pin Top ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

95

1435.5

... More
code6 - Charges for servicing and lubrication of alternator for existing DG Sets (AQR) SE ltr no:2008 dt:10.06.2014 SL No(7) d) 125 KVA to 250.KVA DG Set. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

4500

9000

... More
code116 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. 2023-24 - PWD-Electrical - Uni SR- Item code -6.13.1 Split ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

20

1703

34078

... More
code96 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 2023-24 - PWD-Electrical - Uni SR- Item code -3.14.15 16/6A combined plug and socket with control switch ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

239

2398

... More
code130 - Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 2023-24 - PWD-Electrical - Uni SR- Item code - 9.5.2 18 AH capacity ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

5731

57310

... More
code128 - 5 Star With Fibre body Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 2023-24 - PWD-Electrical - Uni SR- Item code - 7.2.1 25 L ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

5

13121

65609.5

... More
code9 - Supplying & Fixing or radiator water coolent solution for DG set (AQR). The work should be carriedout as per the directions of the Engineer in charge of the work. ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

25

195

4875

... More
code144 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 2023-24 - PWD-Electrical - Uni SR- Item code -11.9.4 LED Floodlight 150W ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2

13739

27478

... More
code188 - Labour Charges for Electrician/ Technician/ operator (Skilled) & Licensed Electrical Wireman with Tools and Electrical safety gadgets as required. ( Basic Rate-633.84 +VDA Rs- 69.05 + ASL 10% + Contractor profit, 10%, Complete Per day Rs.843.47) 7 Persons x 312 Man Days = 2184 Man Days As Per Labour Department Notifica 0tion No.KaE/83/LAW/2022 Dt. 13.01.2023 ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

2184

843

1842138.48

... More
code17 - Supplying of bearing grease (AQR) SE ltr no:705 dt:11.05.2020 SL No(9) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

5

105

525

... More
code106 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 2023-24 - PWD-Electrical - Uni SR- Item code - 5.18.1 6-32 A SP ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

10

456

4565

... More
code73 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.5.3 4 Module ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

13

192

2502.5

... More
code25 - Servicing of MCCB with control contacts operating mechanism and termination etc. main panel periodically maintenance for every six months of following of capacity (AQR) SE ltr no:2008 dt:10.06.2014 SL No(14) c) 250 amps 3 pole MCCB as per manufacturer standard ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

15

500

7500

... More
code67 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 2023-24 - PWD-Electrical - Uni SR- Item code - 3.3.3 4-5 Way ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

8

150

1205.6

... More
code27 - Charges fro servicing of Air Circuit breakers of following cleaning of ACB arcing cantacts, main contacotrs/arc cuts tesing of manual spring change motor, assembly testing of triping coils and lubrication of ACB as per requirement of following capacity at main Lt panel. Periodicaly maintenance for every six months (AQR) SE ltr no:2008 dt:10.06.2014 SL No(13) d) 1000 amps 4 pole electrically operated draw out ACB ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.

6

1600

9600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.