The Minor Irrigation Department has issued a formal invitation for competitive bids for Providing Irrigation Facility Through Borewell To The Sy.no. 29/3 Of Shri Umesh S/o Nathuram Pawar Of Shakapur Village In Aland Taluka Kalaburagi District. (under Tsp For The Year 2024-25) (reserved For Sc Category Only) in Kalaburagi, Karnataka, with an estimated contract value of Rs. 3,55,789. The bid opening date for this tender is 29-12-2024 and the last date for bid submission is 08-01-2025. Interested bidders for Minor Irrigation Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Minor Irrigation Department Tender
Civil And Construction
Irrigation Work
Opening Date29 Dec 2024
Closing Date8 Jan 2025
Tender Amount₹ 3,55,789.35
Costs
EMD
₹ 4,500Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
MI/2024-25/OW/WORK_INDENT3292Bid Award Id
ViewTender No
MI/2024-25/OW/WORK_INDENT3292Tender Authority
Minor Irrigation Department ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
10.14.20 - Providing and installing at site of work P.V.C. pipes including cost of pipes
and specials and labour, including lowering into trenches, laying true
to line, level and perfect linking at joints leak proof including jointing
of approved type with all labour charges and all lift charges, handling
charges including encasing the pipe around to a depth not less than
15 cms with gravel or selected earth available from the excavation etc.
complete.160mm(weight of pipe -3.923 kg) etc. complete.with all lead and lift as per the direction of Engineer in Charge.
6
1048
6293.7
... More
13.39 - Earthing: Providing and fixing and wiring earth electrode for grounding
circuits IC cutouts and other equipments on the meter board in the pit.
The pits should be filled up with equal proportion of salt and charcoal
150mm around the pipe to complete depth. The connection from the
pipe to the conduits etc. is to established through GI wire of sizes as per
clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts,
the pipe shall have 16 through holes of 12mm dia. etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
3937
3937.5
... More
13.22.5 - Supply and delivery at site Brand new best make PVC insulated cable of
Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990
with ISI Mark and as per its latest amendments.1x3x10 Sqm etc. complete.with all lead and lift as per the direction of Engineer in Charge.
160
294
47040
... More
13.34 - Labour charges for erection of outdoor type panel board and meter board
units with all necessary materials and labour, tools and equipments
including providing cement concrete foundation bed etc., complete
as per specification, with testing of as per instructions of engineer
incharge of work. etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
1522
1522.5
... More
13.23.1 - Supply and delivery at site of brand new best make pressure gauge
bourdon type as per IS 778/1984 with ISI Mark and as per its latest
amendments.Size 63 mm etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
436
436.8
... More
12.1.3 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
100m to 150m depth) etc. complete.with all lead and lift as per the direction of Engineer in Charge.
50
517
25882.5
... More
13.32 - Labour charges for Erection, Electrification and commissioning of Pump
sets, including aligning and balancing of all items including supply and
erection of two pair of supporting clamps, bore well caps, cable clips and
water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary
tests as per specifications, with testing of as per instructions of engineer
incharge of work. etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
6825
6825
... More
13.35.5 - Labour charges for providing connection using insulated sheathed
steel wire cable as per IS 1554/ 1988 with latest amendments from
KPTCL pole to meter board unit, with all necessary materials ,tools and
equipments,as per specificationswith testing of as per instructions of
engineer incharge of work. 3.5 *16 sqmm etc. complete.with all lead and lift as per the direction of Engineer in Charge.
30
283
8505
... More
11.3.6 - Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing
for water tightness, with all lead and commissioning. (contractor will
make his own arrangements for procuring water for testing) For:Heavy
Duty GI Pipe etc. complete.Heavy Duty GI pipe of 50mm dia etc. complete.with all lead and lift as per the direction of Engineer in Charge.
2
660
1320.9
... More
9.4.1 - Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
rolling and lowering into trenches, laying true to line and jointing of
pipes and specials with electrofusion welding, giving hydraulic test
as per relevant ISS with all lead and lifts including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary
like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete
(Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN12.5,63mm dia etc. complete.with all lead and lift as per the direction of Engineer in Charge.
150
287
43155
... More
13.26 - Supply and delivery at site delivery of best indigenous brand new MCB
(Miniature Circuit Breakers) of required capacity as per IS 88228/1978
and its latest amendments and with ISI Mark of 6/10/16/20/25/40
Amps with scalable box. etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
1207
1207.5
... More
13.25.1 - Supply and delivery at site of brand new best make non-return valve as
per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
1312
1312.5
... More
10.13.4 - Supply and delivery at site special moulded variety PVC reducer as per
IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with
its latest amendments 50 mm dia PVC REDUCER etc. complete.with all lead and lift as per the direction of Engineer in Charge.
2
61
123.9
... More
12.1.1 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rigof capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every
0m to 50m depth) etc. complete.with all lead and lift as per the direction of Engineer in Charge.
50
388
19425
... More
3.15.6 - Providing Submersible Pump Set of 150mm dia suitable for bore well and
confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt
Motor as per specifications, to work site as per necessary ammendments
and instructions of engineer incharge of work. For 3 HP etc. complete7.50 HP - 120 LPM @ 132 m = 14 STG Outlet Dia - 2.00" etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
40864
40864.95
... More
13.25 - Supply and delivery at site best indigenous brand new power capacitor as
per IS 2834/1986 with latest amendments with KPTCL authorities and
erection, electrification and commissioning of the same at the location
of respective pump sets. etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
577
577.5
... More
12.34 - Providing and laying at site of work MS casing caps as per IS 1239 (part-
II) 1982 with all latest amendments if any for any dia. The thickness
of plate used for covering one end shall be 3mm (minimum). The
dimensions of caps and colars shall be strictly as per IS 1239 (Part-II)
1982 with all amendments including cost of material and labour charges
for fixing, if any etc. complete with all lead and lifts and as directed by
the Engineer in charge
1
172
172.2
... More
13.37 - Providing main connection from pole PVC insulated sheathed steel wire
cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI
mark from KPTCL pole to meter board unit. etc. complete.with all lead and lift as per the direction of Engineer in Charge.
30
89
2677.5
... More
12.33 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with
all latest amendments if any for any dia. The thickness of plate used for
covering one end shall be 3mm (minimum). The dimensions of caps and
colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
157
157.5
... More
11.12.6 - Supply and delivery at site wrought middle steel (galvanized) GI union
confirming to IS 1239-II, 1991 with latest amendments if any.For 50 mm dia GI Union etc. complete.with all lead and lift as per the direction of Engineer in Charge.
2
280
560.7
... More
10.14.6 - Providing and installing at site of work P.V.C. pipes including cost of pipes
and specials and labour, including lowering into trenches, laying true
to line, level and perfect linking at joints leak proof including jointing
of approved type with all labour charges and all lift charges, handling
charges including encasing the pipe around to a depth not less than
15 cms with gravel or selected earth available from the excavation etc.
complete.160mm(weight of pipe -2.753 kg) etc. complete.with all lead and lift as per the direction of Engineer in Charge.
144
614
88452
... More
12.4 - Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergerss method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.with all lead and lift as per the direction of Engineer in Charge.
1
5552
5552.4
... More
11.8.6 - Supply and delivery at site wrought middle steel (galvanized) GI bend
confirming to IS 1239-II, 1991 with latest amendments if any.For 50 mm dia GI BEND etc. complete.with all lead and lift as per the direction of Engineer in Charge.
2
375
751.8
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements