Medical Education Department Tender

... More
The Medical Education Department has issued a formal invitation for competitive bids for Annual Rate Contract For Civil Maintenance And Repair Works At Bims Belagavi in Belagavi, Karnataka, with an estimated contract value of Rs. 1,01,58,891. The bid opening date for this tender is 27-05-2025 and the last date for bid submission is 21-06-2025. Interested bidders for Medical Education Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Medical Education Department Tender

Works
Civil And Construction
Civil Works Others
Opening Date27 May 2025
Closing Date21 Jun 2025
Tender Amount₹ 1,01,58,891.75 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vol-2 ,P.No-89, I.No-11.37.1 - Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paid inbasic item):With float glass panes of 4.0 mm thickness (weight not lessthan 10kg/ m²) including cost of materials, labour, usage charges ofmachinery complete as per specifications and as per directions of theEngineer-in-Charge. (PWD SR 2023-24 Vol-2 ,P.No-89, I.No-11.37.1)

200

1037

207480

... More
Vol-2 ,P.No-64, I.No-9.37 - Providing and laying red oxide flooring 40 mm thick, with an under layerof 30mm thick M-15 cement concrete and top layer of 10mm thick plasterwith 1:3 cement mortar mixed with red oxide finished with floating coatof neat cement mixed with red oxide ( mix of same proportion ) , includingcost of materials, labour, curing, complete as per specifications. (PWD SR 2023-24 Vol-2 ,P.No-64, I.No-9.37)

100

825

82530

... More
Vol-2 ,P.No-101, I.No-12.32 - Providing and fixing in position Mathi / Nandi wood fully panelled shuttersfor windows with stiles and rails of 25mm. thick, 75mm wide in twohalves with panels of 20mm thick including cost of materials, labourcharges, usage charges complete as per specifications. (excluding cost offixtures) (PWD SR 2023-24 Vol-2 ,P.No-101, I.No-12.32)

50

6134

306705

... More
Vol-2 ,P.No-207, I.No-20.104 - Repairing and fixing shutters (panelled or glazed) to doors, windows,ventilators and cupboards.(PWD SR 2023-24 Vol-2 ,P.No-207, I.No-20.104)

50

1023

51187.5

... More
Vol-1 P.No-7 I.No- 1.9 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR 2023-24 Vol-1 ,P.No-7, I.No- 1.9)

80

279

22344

... More
Vol-2 ,P.No-133, I.No-14.9.1 - White glazed fire clay kitchen sink of size 600x450x 250 mm (PWD SR 2023-24 Vol-2 ,P.No-133, I.No-14.9.1)

5

3130

15650.25

... More
Vol-1 P.No-10 I.No- 1.17.1 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed,removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. 1.17.1 All kinds of soils. Depth upto 1.50 m (PWD SR 2023-24 Vol-1 ,P.No-10, I.No- 1.17.1)

80

275

22008

... More
Vol-2 ,P.No-189, I.No-19.22.1 - Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. 19.22.1 For thickness of tiles 10 mm to 25 mm (PWD SR 2023-24 Vol-2 ,P.No-189, I.No-19.22.1)

500

50

25200

... More
Vol-2 ,P.No-17, I.No- 6.35 - Providing Solid Concrete Bricks of size 225x100x75mm having strength5Mpa & above for superstructure above plinth level in all shapes and sizeswith Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of allmaterials, labour, scaffolding and usage charges of machineries & otherincidental charges complete as per the direction of engineer incharge ofwork.(PWD SR 2023-24 Vol-2 ,P.No-17, I.No- 6.35)

80

9652

772212

... More
Vol-2 ,P.No-45, I.No-8.28 - Finishing walls with water proofing cement paint of required shade :Newwork (Two coats applied @ 4.84 kg/10 m²) to give an even shade afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. (PWD SR 2023-24 Vol-2 ,P.No-45, I.No-8.28)

300

93

28035

... More
Vol-2 ,P.No-137, I.No-14.40.1 - 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. (PWD SR 2023-24 Vol-2 ,P.No-137, I.No-14.40.1)

20

501

10038

... More
Vol-1 P.No-5, I.No 1.4.1 - 1.4 Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sidesneatly dressed disposing off the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.1.4.1 In all kinds of soils Depth upto 1.5 m (PWD SR 2023-24 Vol-1 ,P.No-5, I.No- 1.4.1)

100

254

25410

... More
Vol-2 ,P.No-104, I.No-12.54 - Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturersspecification & direction of Engineer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-104, I.No-12.54)

200

333

66780

... More
Vol-2 ,P.No-9, I.No- 5.4 - Providing Random rubble masonry with hard stone in foundation andplinth including levelling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinthlevel with :5.4 Providing Size Stone masonry with hard stone in foundation & plinth withCement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR 2023-24 Vol-2 ,P.No-9, I.No- 5.4)

50

6708

335422.5

... More
Vol-2 ,P.No-150, I.No-15.5 - Providing and laying water proofing treatment to the Rafts, Below gradeslab, Lift pits, water retaining structures with fully bonded High DensityPolyethlene Membrane (HDPE) of 1.2mm composite thickness andhaving tensile strength of 25 MPa (as per ASTM D 412), elongationof 500% (as per ASTM D 412), puncture resistance of 1000N (as perASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903),hydrostatic head resistance 70m (as per ASTM D 5385). The systemshould be fully bonded to the RCC thereby conforming to IS 16471:2017requirements of UG waterproofing structures. The membrane should beminimum 2.4m wide to reduce the number of joints with minimum 75mmfactory made selvedge’s and comprising of an HDPE layer and a pressuresensitive adhesive layer which is covered by a weather proof protectiveand trafficable granular layer to protect self-adhesive polymer layer, etc,including surface preparation completely as per specification.(PWD SR 2023-24 Vol-2 ,P.No-150, I.No-15.5)

100

635

63525

... More
Vol-2 ,P.No-207, I.No-20.108 - Repairs to existing Aluminium partition, refixing and relocating including cost of material,labour, complete as per specifications. (PWD SR 2023-24 Vol-2 ,P.No-207, I.No-20.108)

80

1762

141036

... More
Vol-2 ,P.No-45, I.No-8.25 - Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :New work (two coats) over and includingwater thinnable priming coat with cement primer after thoroughlybrooming the surface to remove all dirt, dust, mortar drops and foreignmatter including preparing the surface even and sand paper smooth, costof materials, labour complete as per specifications and as per directionsof Engineer-in-charge. (PWD SR 2023-24 Vol-2 ,P.No-45, I.No-8.25)

300

143

43155

... More
Vol-2 ,P.No-95, I.No-11.56 - Fencing with G.I. barbed wire R.C.C. post placed at required distance,embedded in cement concrete blocks, every 15th post, last but one endpost and corner post shall be strutted on both sides and end post one sideonly, provided with horizontal lines and two diagonals of barbed wireweighing 9.38 kg per 100 m (minimum), between the two posts fittedand fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earthwork and concrete to be paid for separately) :- Payment to be made permetre cost of total length of barbed wire used (PWD SR 2023-24 Vol-2 ,P.No-95, I.No-11.56)

2000

12

25200

... More
Vol-2 ,P.No-82, I.No-11.16.1 - Providing and fixing Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes including cost of materials, labour, usagecharges of machinery complete as per specifications and as per directionsof the Engineer-in-Charge.(PWD SR 2023-24 Vol-2 ,P.No-82, I.No-11.16.1)

1500

142

214200

... More
Vol-2 ,P.No-202, I.No-20.45 - Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same with CM 1:4 etc. complete as per direction of Engineer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-202, I.No-20.45)

100

232

23205

... More
Vol-2 ,P.No-133, I.No-14.7.6 - White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap (PWD SR 2023-24 Vol-2 ,P.No-133, I.No-14.7.6)

30

2378

71347.5

... More
Vol-2 ,P.No-26, I.No- 7.38 - Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should have protective guardfilm of 25 microns minimum to avoid scratches during transportation andshould be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required.(PWD SR 2023-24 Vol-2 ,P.No-26, I.No- 7.38)

120

596

71568

... More
Vol-2 ,P.No-188, I.No-19.14.1 - Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking to the appropriate disposal area as per direction of Engineer-in-charge. 19.14.1 Of sectional area 40 cm² and above (PWD SR 2023-24 Vol-2 ,P.No-188, I.No-19.14.1)

20

3054

61089

... More
Vol-2 ,P.No-86, I.No-11.34A - Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to steel windows by welding (PWD SR 2023-24 Vol-2 ,P.No-86, I.No-11.34A)

1800

176

317520

... More
Vol-2 ,P.No-64, I.No-9.36 - Providing flooring with 25mm thick polished Cuddapah slabs using cementmortar 1:6, 25mm thick over existing cement concrete bed or top of rooflaid to line and level and jointed with cement slurry mixed with pigmentto match the shade of the slab , including cost of materials, labour, curing,polishing complete as per specifications. (PWD SR 2023-24 Vol-2 ,P.No-64, I.No-9.36)

50

1732

86625

... More
Vol-2 ,P.No-59, I.No-9.1 - Providing and laying Cement concrete flooring 40 mm thick with 20 mmnominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement,including cement slurry complete. (PWD SR 2023-24 Vol-2 ,P.No-59, I.No-9.1)

150

473

71032.5

... More
Vol-2 ,P.No-207, I.No-20.103 - Repairing door and window frames with available wood to the required size.(PWD SR 2023-24 Vol-2 ,P.No-207, I.No-20.103)

50

1023

51187.5

... More
Vol-2 ,P.No-201, I.No-20.38 - Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 m² and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish,all complete as per the direction of Engineer-In-Charge. (For Roof and Water Tanks)(PWD SR 2023-24 Vol-2 ,P.No-201, I.No-20.38)

150

543

81585

... More
Vol-2 ,P.No-41, I.No- 8.1.1 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding, includingcost of materials, labour, curing complete as per specifications and as perdirections of Engineer-in-charge. (PWD SR 2023-24 Vol-2 ,P.No-41, I.No- 8.1.1)

150

267

40162.5

... More
Vol-2 ,P.No-104, I.No-12.55.1 - Providing & fixing 30mm thick factory made rigid foam Prelam PanelledDoor Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and15x15mm for top & bottom rails, covered with heat moulded PrelaminatedPVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mmthick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottomrail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insertfor top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminatedon either side fitted in the M.S. frame, Sealed to the stiles & rails with PVCDesigner beading on either side & joined together with solvent cementadhesive etc., Complete as per manufacturers specification & direction ofEngineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55.1 -do- with both side prelam(PWD SR 2023-24 Vol-2 ,P.No-104, I.No-12.55.1)

50

2484

124215

... More
Vol-2 ,P.No-63, I.No-9.25 - Providing and laying 60mm thick factory made cement concrete paverblock of approved shape and colour of M -30 grade made of C&D wasteby block making machine with vibratory compaction laid in requiredpattern and including over 50mm thick compacted bed of coarse sand,filling the joints with fine sand etc. all complete as per the direction ofEngineer-in-charge. (PWD SR 2023-24 Vol-2 ,P.No-63, I.No-9.25)

500

840

420000

... More
Vol-1, P.No-A50, I.No-IV - Engaging Mazdoor for cleaning, etc complete as per direction of Engineer (CSR 2023-24, Vol-1, P.No-A50, I.No-IV)

100

618

61824

... More
Vol-1 ,P.No-15, I.No- 2.2.4 - Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.2.2.4 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with 20% partial replacement with Recycled concrete aggregate (RCA) (PWD SR 2023-24 Vol-1 ,P.No-15, I.No- 2.2.4)

50

6609

330487.5

... More
Vol-2 ,P.No-51, I.No-8.57 - Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc.complete as per specifications and as per directions of Engineer in charge.(PWD SR 2023-24 Vol-2 ,P.No-51, I.No-8.57)

600

13

8190

... More
Vol-2 ,P.No-45, I.No-8.29 - Finishing walls with textured exterior paint of required shade :New work(Two coats applied @ 3.28 L/10 m²) over and including priming coat ofexterior primer applied @ 2.20kg/10 m² to give an even shade afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. (PWD SR 2023-24 Vol-2 ,P.No-45, I.No-8.29)

200

297

59430

... More
Vol-2 ,P.No-219, I.No-22.23 - Providing & fixing Vertical Blinds of reputed make of shape 100mm regular fabric with powder coated aluminium channel, telting with PVC Chain system with all necessary fittings and fixtures as per direction of Engineer in charge(PWD SR 2023-24 Vol-2 ,P.No-219, I.No-22.23)

120

892

107100

... More
Vol-2 ,P.No-53, I.No-8.74.1 - Finishing walls with Acrylic Smooth exterior paint of required shade : Oldwork (Two coat applied @ 1.67 l/ 10 m²) on existing cement paint surfaceincluding preparing the surface after thoroughly cleaning the surface toremove all dirt, dust and foreign matter, cost of materials, labour completeas per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-53, I.No-8.74.1)

500

110

55125

... More
Vol-2 ,P.No-50, I.No-8.54.2 - Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 g/L ofapproved brand and manufacture, including applying additional coatswherever required to achieve even shade and colour. Two coats as perspecifications and as per directions of Engineer in charge. (PWD SR 2023-24 Vol-2 ,P.No-50, I.No-8.54.2)

500

115

57750

... More
Vol-2 ,P.No-24, I.No- 7.28.2 - Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceilingup to a height of 5 m above floor level, over first class kail wood strips 25x6mm with 10 mm gap in between and reinforced with rabbit wire meshfixed to wooden frame.7.28.2 Curved surfaces (PWD SR 2023-24 Vol-2 ,P.No-24, I.No- 7.28.2)

120

1572

188748

... More
Vol-2 ,P.No-207, I.No-20.102 - Repairs to roof with available corrugated zinc sheets/ A.C.sheets with new J bolts, screws and washers etc., on existing reeper and rafters.(PWD SR 2023-24 Vol-2 ,P.No-207, I.No-20.102)

150

194

29137.5

... More
Vol-2 ,P.No-65, I.No-9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mmthick on 10mm thick cement plaster 1:3 and jointed with white cementslurry over existing rough plaster surface using glazed tiles of approvedmake and size including cost of materials, labour, complete as perspecifications.(PWD SR 2023-24 Vol-2 ,P.No-65, I.No-9.39)

50

1521

76072.5

... More
Vol-2 ,P.No-5, I.No- 4.1 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (PWD SR 2023-24 Vol-2 ,P.No-5, I.No- 4.1)

100

123

12390

... More
Vol-2 ,P.No-193, I.No-19.55 - Dismantling old plaster or skirting raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-193, I.No-19.55)

500

38

19425

... More
Vol-2 ,P.No-22, I.No- 7.14.1 - Painting top of roofs with bitumen of approved quality @ 17kg per10 m2 impregnated with a coat of coarse sand at 60 cudm per 10 m2,including cleaning the slab surface with brushes and finally with a pieceof cloth lightly soaked in kerosene oil complete :7.14.1 With residual type petroleum bitumen of grade VG -10 (PWD SR 2023-24 Vol-2 ,P.No-22, I.No- 7.14.1)

50

168

8400

... More
Vol-2 ,P.No-14, I.No- 6.12 - Providing Half brick masonry with common burnt clay Non Modular bricksof class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1cement : 3 coarse sand) including cost of all materials, labour, scaffoldingand usage charges of machinery & other incidental charges complete asper the direction of engineer incharge of work. (PWD SR 2023-24 Vol-2 ,P.No-14, I.No- 6.12)

50

1053

52657.5

... More
Vol-2 ,P.No-78, I.No-11.6.1 - Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on speciallydesigned pipe shaft with brackets, side guides and arrangements forinside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wiresprings manufactured from high tensile steel wire of adequate strengthconforming to IS: 4454 - part 1 and M.S. top cover of required thicknessfor rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top coverincluding cost of materials, labour, usage charges of machinery completeas per specifications and as per directions of the Engineer-in-Charge. (PWD SR 2023-24 Vol-2 ,P.No-78, I.No-11.6.1)

40

2764

110586

... More
Vol-2 ,P.No-131, I.No-14.1.1 - White Vitreous china Orissa pattern W.C. pan of size 580x440 mm withintegral type foot rests (PWD SR 2023-24 Vol-2 ,P.No-131, I.No-14.1.1)

20

5128

102564

... More
Vol-2 ,P.No-50, I.No-8.51 - Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plasteredwall surface to prepare the surface even and smooth complete as perspecifications and as per directions of Engineer in charge. (PWD SR 2023-24 Vol-2 ,P.No-50, I.No-8.51)

400

105

42000

... More
Vol-2 ,P.No-51, I.No-8.56.1 - White washing with lime to give an even shade :Old work (two coats) asper specifications and as per directions of Engineer in charge. (PWD SR 2023-24 Vol-2 ,P.No-51, I.No-8.56.1)

500

15

7875

... More
Vol-2 ,P.No-50, I.No-8.52.2 - Distempering with 1st quality acrylic distemper, having VOC (VolatileOrganic Compound) content less than 50 g/L, of approved brandand manufacture, including applying additional coats wherever required,to achieve even shade and colour. Two coats as per specifications and asper directions of Engineer in charge. (PWD SR 2023-24 Vol-2 ,P.No-50, I.No-8.52.2)

400

79

31920

... More
Vol-1 ,P.No-16, I.No- 2.4.3 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.2.4.3 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol-1 ,P.No-16, I.No- 2.4.3)

60

6652

399168

... More
Vol-2 ,P.No-50, I.No-8.55.1 - Applying priming coats with primer of approved brand andmanufacture, having low VOC (Volatile Organic Compound) content.With ready mixed pink or grey primer on wood work (hard and softwood) having VOC content less than 50 g/L as per specifications and asper directions of Engineer in charge. (PWD SR 2023-24 Vol-2 ,P.No-50, I.No-8.55.1)

500

58

29400

... More
Vol-2 ,P.No-47, I.No-8.36.1 - Finishing with Epoxy paint (two coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete. On steel work includingpreparing the surface after thorougly cleaning oil, grease, dirt and foreignmatter, cost of materials, labour complete as per specifications and as perdirections of Enginer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-47, I.No-8.36.1)

140

184

25872

... More
Vol-1 ,P.No-15, I.No- 2.1.4 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.2.1.4 Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol-1 ,P.No-15, I.No- 2.1.4)

40

6527

261114

... More
Vol-2 ,P.No-77, I.No-11.5.1 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions andcorners, all necessary fittings complete, including applying a primingcoat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonalbraces including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR 2023-24 Vol-2 ,P.No-77, I.No-11.5.1)

30

4701

141057

... More
Vol-2 ,P.No-13, I.No- 6.3 - Providing Brick work with common burnt clay modular bricks of classdesignation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding andusage charges of machinery & other incidental charges complete as perthe direction of engineer incharge of work. (PWD SR 2023-24 Vol-2 ,P.No-13, I.No- 6.3)

80

9317

745416

... More
Vol-2 ,P.No-187, I.No-19.13.2 - Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.19.13.2 Of area beyond 3 m²(PWD SR 2023-24 Vol-2 ,P.No-187, I.No-19.13.2)

100

129

12915

... More
Vol-2 ,P.No-47, I.No-8.33.3 - Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two coat applied @ 0.90L/10 m² over an under coat of primerapplied @ 0.80 L/10 m² of approved brand and manufacture includingpreparing the surface after thorougly cleaning oil, grease, dirt and foreignmatter, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-47, I.No-8.33.3)

200

145

29190

... More
Vol-2 ,P.No-21, I.No- 7.1.1 - Providing & fixing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel primerand two coats of approved paint on overlapping of sheets complete asper design drawings (up to any pitch in horizontal/ vertical or curvedsurfaces), excluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required as per the direction ofEngineer in charge.7.1.1 0.63 mm thick with zinc coating not less than 275 g/ m² (PWD SR 2023-24 Vol-2 ,P.No-21, I.No- 7.1.1)

180

922

166131

... More
Vol-2 ,P.No-25, I.No- 7.32.1 - 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-(Part I) : 2011 (Board with BIS Certification marks only)(PWD SR 2023-24 Vol-2 ,P.No-25, I.No- 7.32.1)

60

1032

61929

... More
Vol-2 ,P.No-156, I.No-15.28 - Toilets Tile Joints (Repair)Providing and grouting tile joints, Cutting the tile joints with the help ofcutting machine (width 3mm-15mm) and filling with of matching shade,using three component Epoxy based tile joint filler, non-sag waterproofgrout, chemical and UV resistance, Pot life 60 mins, VOC (EPA 24) 8gm/kg and water absorption after 7 days 0.5g Joints shall be clean,dry, free from dirt, etc prior to application. Apply tile grout using arubber trowel/grout floater, press firmly into joints, ensure completefill and remove excess grout from surface using suitable method.The work shall be carried out as per the directions of the Engineer incharge.(PWD SR 2023-24 Vol-2 ,P.No-156, I.No-15.28)

150

892

133875

... More
Vol-2 ,P.No-95, I.No-11.59 - Providing and fixing G.I. chain link fabric fencing of required width inmesh size 50x50 mm including strengthening with 2 mm dia wire or nuts,bolts and washers as required complete as per the direction of Engineerin-charge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dianot less than 5 mm in required colour and shade) (PWD SR 2023-24 Vol-2 ,P.No-95, I.No-11.59)

400

883

353220

... More
Vol-2 ,P.No-153, I.No-15.17 - Treating Severe Dampness & Rising dampness in WallsProviding and Applying 15 mm thick dimensionally stable fibrousreinforced cementitious structural grade dual shrinkage Polymer RepairMortar on internal wall damp patches 29kg/m2. The material havingCompressive strength of 38 MPa at 28 days as per EN 12190, AdhesiveBond Test, 1.5 Mpa as per EN 1542, followed by Water curing bysprinkling water for 3 times a day for 5- 7 days. Ensure that removinginternal wall plaster up to the brick level. Extend up to minimum 2 feetin wide in excess to the damp patches. clean the effected surface followedby Item No. 4 should be applied across the entire surface and apply a coatof spatter dash bond coat over cured coating. The dashing shall consist of(1-part SBR : 1 Part cement: 2 part wash sand) mixed to thick slurry andkept well stirred prior to applying the Polymer Repair Mortar. The finishedcost to include surface preparation completely as per specification.(PWD SR 2023-24 Vol-2 ,P.No-153, I.No-15.17)

100

1822

182280

... More
Vol-2 ,P.No-126, I.No-13.53 - Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slabwith 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc.complete as per standard design: Inside dimensions 455x610 mm and45 cm deep for single pipe line : With common burnt clay (non modular)bricks of class designation 3.5 (PWD SR 2023-24 Vol-2 ,P.No-126, I.No-13.53)

10

5924

59241

... More
Vol-2 ,P.No-203, I.No-20.50 - Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications.(PWD SR 2023-24 Vol-2 ,P.No-203, I.No-20.50)

1500

13

20475

... More
Vol-2 ,P.No-63, I.No-9.24 - Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing,curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.(PWD SR 2023-24 Vol-2 ,P.No-63, I.No-9.24)

50

2994

149730

... More
Vol-2 ,P.No-47, I.No-8.34.1 - Applying priming coat: With ready mixed pink or Grey primer ofapproved brand and manufacture on wood work (hard and soft wood)including preparing the surface after thorougly cleaning oil, grease, dirtand foreign matter, cost of materials, labour complete as per specificationsand as per directions of Engineer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-47, I.No-8.34.1)

500

55

27825

... More
Vol-2 ,P.No-60, I.No-9.10 - Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approvedmake in all colours, shades except burgundy, bottle green, black of any sizeas approved by Engineer-in-Charge in skirting, risers of steps and dadosover 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand)and jointing with grey cement slurry @ 3.3kg per m2 including pointingin white cement mixed with pigment of matching shade complete. (PWD SR 2023-24 Vol-2 ,P.No-60, I.No-9.10)

70

1161

81291

... More
Vol-2 ,P.No-94, I.No-11.52 - Providing and fixing 12 mm thick frameless toughened glass doorshutter of approved brand and manufacture, including providing andfixing top & bottom pivot & double acting hydraulic floor spring type fixingarrangement and making necessary holes etc. for fixing required doorfittings, all complete as per direction of Engineer-in-charge (Door handle,lock and stopper etc. to be paid separately) including cost of materials,labour, usage charges of machinery complete as per specifications and asper directions of the Engineer-in-Charge. (PWD SR 2023-24 Vol-2 ,P.No-94, I.No-11.52)

30

4958

148743

... More
Vol-2 ,P.No-49, I.No-8.48 - Floor polishing on masonry or concrete floors with wax polish of approvedbrand and manufacture to give an even surface including preparing thesurface after thoroughly brooming the surface to remove all dirt, dust,mortar drops and foreign matter , cost of materials, labour complete asper specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol-2 ,P.No-49, I.No-8.48)

1000

66

66150

... More
Vol-2 ,P.No-187, I.No-19.1 - Demolishing lime concrete manually/ by mechanical means and disposal of material to the appropriate disposal area as per direction of Engineerin-charge.(PWD SR 2023-24 Vol-2 ,P.No-187, I.No-19.1)

30

1746

52384.5

... More
Vol-2 ,P.No-60, I.No-9.12.2 - Providing and laying vitrified floor tiles with thickness 9-10 mm indifferent sizes with water absorption less than 0.08% and conforming toIS: 15622, of approved make, in all colours and shades, laid on 20mm thickcement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cementslurry @ 3.3 kg/ m2 including grouting the joints with white cement andmatching pigments etc., complete. 9.12.2 Size of Tile 600x600 mm (PWD SR 2023-24 Vol-2 ,P.No-60, I.No-9.12.2)

100

1202

120225

... More
Vol-2 ,P.No-51, I.No-8.63 - Wall painting with plastic emulsion paint of approved brand andmanufacture to give an even shade: One coats on old work as perspecifications and as per directions of Engineer in charge.(PWD SR 2023-24 Vol-2 ,P.No-51, I.No-8.63)

600

86

51660

... More
Vol-2 ,P.No-51, I.No-8.60 - Removing dry or oil bound distemper, water proofing cement paint andthe like by scrapping, sand papering and preparing the surface smoothincluding necessary repairs to scratches etc. complete. as per specificationsand as per directions of Engineer in charge.(PWD SR 2023-24 Vol-2 ,P.No-51, I.No-8.60)

600

17

10710

... More
Vol-2 ,P.No-46, I.No-8.30 - Finishing walls with Acrylic Smooth exterior paint of required shade :Newwork (Two coat applied @ 1.67L/10 m² over and including priming coat ofexterior primer applied @ 2.20 kg/10 m²) with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove alldirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge.(PWD SR 2023-24 Vol-2 ,P.No-46, I.No-8.30)

300

182

54810

... More
Vol-2 ,P.No-60, I.No-9.7.2 - In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarsesand) with Acid and alkali resistant tile (PWD SR 2023-24 Vol-2 ,P.No-60, I.No-9.7.2)

50

1323

66150

... More
Vol-2 ,P.No-125, I.No-13.48 - Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with seal ringconforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes 100 mm diameter (PWD SR 2023-24 Vol-2 ,P.No-125, I.No-13.48)

200

305

61110

... More
Vol-2 ,P.No-155, I.No-15.23 - Retaining Wall (Inside) / OHT / UG Sump TanksProviding & Applying Crystalline waterproofing slurry coat RCC structurelike Retaining wall, Underground tank. The material having chemicalresistance properties, seals shrinkage cracks up to 0.4 mm width,capable of preventing water dampness & seepages, Water permeabilityis Nil confirms to BS EN 12390 Part 8: 2000. Powder to water mixed ata ratio (5:2) 5 parts powder and 2 parts water, applied @ 1.5kg/m2 in2 coats to achieve 1.0mm DFT on a cleaned surface free from all loosematerials etc., complete. The finished cost to include surface preparationcompletely as per specification.(PWD SR 2023-24 Vol-2 ,P.No-155, I.No-15.23)

50

2572

128625

... More
Vol-1, P.No-A50, I.No-IV - Engaging Scanvanger for cleaning the toilets etc, complete as per specification. (CSR 2023-24, Vol-1, P.No-A50, I.No-IV)

100

618

61824

... More
Vol-2 ,P.No-77, I.No-11.3 - Providing and fixing in position collapsible steel shutters with verticalchannels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6 mm, with 40 mm diasteel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primerincluding cost of materials ,labour, usage charges of machinery completeas per specifications and as per directions of the Engineer-in-Charge.(PWD SR 2023-24 Vol-2 ,P.No-77, I.No-11.3)

40

8689

347592

... More
Vol-2 ,P.No-127, I.No-13.55 - Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 600X850 mm internaldimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slabwith 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc.complete as per standard design: Inside dimensions 600x 850 mm and45 cm deep for pipe line with three or more inlets : With common burntclay (non modular) bricks of class designation 3.5 (PWD SR 2023-24 Vol-2 ,P.No-127, I.No-13.55)

10

7771

77710.5

... More
Vol-2 ,P.No-108, I.No-12.84 - Providing fixing of 2 track 2 panel sliding windows made out of multichambered UPVC(Matching to RAL 9016) sections and with minimumTiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 44mm width 40 mm height with reinforcement of 1mm thickness and Sash with overall size of 27mm 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P s shall not be made) (PWD SR 2023-24 Vol-2,P.No-108, I.No-12.84)

50

5274

263707.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.